TOWER COUNTER TOP STG RF STG RF6 STG RF9 STG RF12 STG RF15 Deck forced refrigeration Sliding doors front and rear Double glazed Two adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Integral condensor Self evaporating Solid glass front - optional HT STG HT6 STG HT9 STG HT12 Sliding doors front and rear Single glazed Three adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Solid glass front - optional Page 1
TOWER COUNTER TOP STG AB STG AB6 STG AB9 STG AB12 Sliding doors front and rear Single glazed Three adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Solid glass front - optional Ambient converted from heated Air removal fan installed in ceiling BM STG BM6 STG BM9 STG BM12 Sliding doors front and rear Overhead halogen lights Wet / dry element in base Single glazed glass Solid glass front - optional Page 2
TOWER STG Cabinet Dimensions & Specifications Model CAbinet SHELVING Shelving sizes refrigerant TOTAL FOOD operating current connection voltage Packed for shipping Length [mm] Depth [mm] Height [mm] CUT OUTS top 2nd 3RD BASE 100mm UNITS Length [mm] Depth [mm] Height [mm] Weight [kg] Cube STGRF6 600 650 925 615x620 2+BASE 490x460 490x460 545x415 134a 55 4.3AMP 10AMP 3 PIN PLUG 220~240V 700 730 1400 143 0.72 STGRF9 900 650 925 915x620 2+BASE 790x460 790x460 845x415 134a 84 4.5AMP 10AMP 3 PIN PLUG 220~240V 1000 730 1450 178 1.06 STGRF12 1200 650 925 1215x620 2+BASE 1090x460 1090x460 1145x415 134a 121 5.0AMP 10AMP 3 PIN PLUG 220~240V 1300 730 1450 212 1.38 STGRF15 1500 650 925 1515x620 2+BASE 1390x460 1390x460 1445x415 134a 154 5.2AMP 10AMP 3 PIN PLUG 220~240V 1600 730 1450 243 1.69 STGHT6 600 650 925 615x620 3+BASE 490x460 490x460 490x460 545x415 55 4.6AMP 10AMP 3 PIN PLUG 220~240V 700 730 1100 88 0.56 STGHT9 900 650 925 915x620 3+BASE 790x460 790x460 790x460 845x415 84 6.2AMP 10AMP 3 PIN PLUG 220~240V 1000 730 1100 110 0.80 STGHT12 1200 650 925 1215x620 3+BASE 1090x460 1090x460 1090x460 1145x415 121 8.3AMP 10AMP 3 PIN PLUG 220~240V 1300 730 1100 126 1.04 STGAB6 600 650 925 615x620 3+BASE 490x460 490x460 490x460 545x415 55 0.2AMP 10AMP 3 PIN PLUG 220~240V 700 730 1100 77 0.56 STGAB9 900 650 925 915x620 3+BASE 790x460 790x460 790x460 845x415 84 0.3AMP 10AMP 3 PIN PLUG 220~240V 1000 730 1100 97 0.80 STGAB12 1200 650 925 1215x620 3+BASE 1090x460 1090x460 1090x460 1145x415 121 0.4AMP 10AMP 3 PIN PLUG 220~240V 1300 730 1100 110 1.04 STGBM9 900 650 925 915x620 9.9AMP STGBM12 1200 650 925 1215x620 11.0AMP STGBM15 1500 650 925 1515x620 15.0AMP 15AMP SUPPLY LEAD ONLY 15AMP SUPPLY LEAD ONLY 20AMP SUPPLY LEAD ONLY 220~240V 1000 730 1100 99 0.80 220~240V 1300 730 1100 119 1.04 220~240V 1600 730 1100 140 1.28 Page 3
TOWER STG RF STG RF6 STG RF6 STG RF9 STG RF9 STG RF12 STG RF15 Page 4 STG RF12 STG RF15
TOWER STG HT STG AB STG HT6 STG AB6 STG HT9 STG AB9 STG HT12 STG AB12 Page 5
TOWER STG BM Page 6
REMOTE INSTALLATION AND SERVICES 3/8 pipe max run 1500 mm condensate drain to four litre container Plumbed Receptacle Vertical pipe runs are not recommended Units are self evaporating to a receptacle in the condensor unit n areas of high humidity units should be plumbed directly to a waste. Pipe runs over 150mm : Expansion valve will need to be fitted Correctly sized condensing unit fitted Correct pipe size determined Maximum 150 mm above finished floor level Drainage to building waste Building waste by client Receptacle placed under unit Page 7
JOINERY AIR FLOW CONSIDERATIONS Hole Cut to meet condenser face 350 mm varies varies 260 mm Joinery divider panel providing sealed air intake plenum with cutout to meet condenser face Intake and extract vents. Min 400mm x 400mm open area. Closed rear. Front vented Front Vented Rear Vented Page 8
EXTRACTION FAN EXTRACTION FAN Extract hot air from box joinery Fan and power cable supplied, screw fixed to joinery Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case Page 9
DROP IN COUNTER TOP CUT OUT DETAILS Remove feet for all drop-in installations Supplied 5mm PVC wedge strip to sides for drop-in unit min 20 mm 150 mm ALLOW 400 mm Cut out see table Condensor unit 545w x 485d x 390h (RF6 485w x 485d x 335h) min 75 mm ALLOW 400 mm Condensor unit 545w x 485d x 390h (RF6 485w x 485d x 335h) Cut out 620 mm Cut out 525 mm RF6 Cut out 525 mm Cut out 585 mm RF6 Cut out 525 mm min 20 mm min 75 mm Open at rear. Open at rear. Page 10 Supplied 5mm PVC wedge strip to sides for drop-in unit. No glue or sealant required
JOINERY TO REAR WALL WITH VENT Horizontal vent in cabinet top for hot air extract Electric biscuit fans can also be fitted to provide mechanical extract Ambient air ducted in to compressor face through air plenum space Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit Vent must be at least 100mm deep and as wide as unit Allow access for cleaning, servicing and waste evaporator water removal Page 11
AIRFLOW AND PLACEMENT GUIDE LINES NO AIR FLOW CLEAR FLOW AIR FLOW BLOCKED too much chilled air around coil can create excessive ice build up CORRECT AIR FLOW INCORRECT AIR FLOW Blocked air flow will retard operation on both HOT and COLD units Ensure trays or plates are not blocking air flow at rear Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors Locations to avoid are : Close to shop front exterior In an outside location In direct sunlight In a high cross wind area Near any source producing excessive heat Page 12
180 mm STG ACCESSORIES Top Mounted Controller Panel Base Tray - Heated Units For against wall installations Sold individually Stainless Steel For heated units Sold in pairs Price Tabs Stainless Steel Write on with marker or adhesive tape Measure 60mm x 30mm Sold in packs of 20 Tong Holder Stainless Steel Drop into counter tray race Sold individually 100 mm 190 mm 80 mm Bag Holder Stainless Steel Drop into counter tray race Solid individually 220 mm 105 mm Ventilation Grill Stainless Steel Sold individually 450 mm Humidity Dish 75 mm 190 mm 450 mm Stainless Steel Perforated lid is removable Page 13
MIRROR FILM Blocks work areas behind units Mirror film adhered to inside of rear door glass Mirror film adhered to inside of rear door glass Add depth to your displays FREE STANDING UNITS Applied to the inside glass rear doors Suitable for heated and chilled units BENCHTOP UNITS Page 14
THERMAL BARRIERS Thermal spacer barriers Provides thermal separation between hot and cold units with minimum spacing Provides a continuous look 20mm Clear polycarbonate with polished edges BENCHTOP DROP IN STG -TBDI BENCHTOP STG -TBC BENCHTOP DROP IN CC5 -TBDI BENCHTOP CC5 -TBC Page 15
STG HEATED UNIT ACCESSORIES Gastro Norm System Pie Trays Stainless Steel Construction Angled display view Stainless Steel Construction Placed on shelves for heated food items GASTRO NORM PIE TRAYS PIE TRAYS Model CODE quantity DIMENSIONS pan depth Model CODE quantity 1ST SHELF DEPTH 2nd SHELF DEPTH 3rd SHELF DEPTH TOTAL tray WIDTH stght6 F92-315 2 Per Unit 265MM X 325MM PANS AND Frame 65MM STGHT9 F92-316 3 Per Unit 265MM X 325MM PANS AND FRAME 65MM STGHT12 F92-317 4 Per Unit 265mm X 325mm pans and frame 65MM STGHT6 AA16015 4 Per Shelf 400mm 365MM 400MM 12 Trays 120MM STGHT9 AA16016 6 Per Shelf 400MM 400MM 400MM 18 Trays 130MM STGHT12 AA16017 9 Per Shelf 400MM 400MM 400MM 27 Trays 120MM Page 16