3102
SDU A Standard Distribution Unit assembled with: A Blank Port (capped) SDU A - 3-5 Loops (available in 3, 4, 5 loops) Made of 1 stainless steel Suitable for 16/2mm Pro-Pipe 4 x 8mm holes for mounting SDU-A on the wall Mounted on a Plated Metal Sheet (1.5mm thick) The Kit Includes: SDU A Manifold Adapter Pro-Pipe 16/2mm made of Pro with an oxygen barrier layer Length per loop 90m (Example: 2 loops = 2 rolls of 90m or alternatively 1 roll of 200m (20m bonus) Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per loop 90 0 Black Angle x 2 per loop Pro-Pipe 16/2mm 4 Screws and Plastic Plugs - attached to the kit An Adapter enabling coupling of systems Thermostat optional Measurements (mm) : SDU A - 3 loops 450 X 250 X 10 SDU A - 4 loops 450 X 300 X 10 SDU A - 5 loops 450 X 350 X 10 Measurements (mm): SDU A-KIT with 90m Pro-Pipe (on pallet) 3 loops 800 X 800 X 81 4 loops 800 X 800 X 99 SDU A-3 Loops coupled with SDU A-4 Loops 5 loops 800 X 800 X 117
SDU B-KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve - 3/4 Clamping Ring Made of 1 stainless steel Suitable for 16/2mm Pro-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing 4 x 8mm holes for mounting the SDU B on the wall The Kit Includes: SDU B Pro-Pipe 16/2mm made of Pro with an oxygen barrier layer Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and Plastic Plugs are attached to the kit Thermostat optional Measurements (mm) SDU B - 2 loops 600X650X160 SDU B - 3 loops 600X650X160 SDU B - 4 loops 600X650X160 SDU B - 5 loops 750X650X160 SDU B - 6 loops 750X650X160 SDU B - 7 loops 750X650X160 SDU B - 8 loops 900X650X160 SDU B - 9 loops 900X650X160 SDU B - 10 loops 900X650X160 12kg 12.5kg 13kg 14kg 14.5kg 15kg 15.5kg 16kg 16.5kg Measurements SDU B-KITS (mm) 2 loops 800X800X760 40kg 3 loops 800X800X940 51kg 4 loops 800X800X1120 62kg 5 loops 800X800X1300 74kg 6 loops 1300X800X790 88kg 7 loops 1300X1000X790 99kg 8 loops 1300X800X970 110kg 9 loops 1300X1000X970 121kg 10 loops 1300X800X1300 132kg
SDU B-V KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve - 3/4 Clamping Ring An Electrical Terminal Box to wire the Electrostatical Valve to the Room Thermostat Air Release Valve Controlled By-Pass Made of 1 stainless steel Actuator to open and close water flow in each loop (Actuator is controlled by thermostat placed in each room) Suitable for 16/2mm Pro-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing 4 x 8mm holes for mounting the SDU B-V on the wall The Kit Includes: SDU B-V Manifold Pro-Pipe 16/2mm made of Pro with an oxygen barrier layer Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and plastic plugs are attached to the kit. Thermostat optional Measurements SDU B-V - 2 loops 600x650x160-12.50kg SDU B-V - 3 loops 600x650x160-13.00kg SDU B-V - 4 loops 600x650x160-13.50kg SDU B-V - 5 loops 750x650x160-14.50kg SDU B-V - 6 loops 750x650x160-15.00kg SDU B-V - 7 loops 750x650x160-15.50kg SDU B-V - 8 loops 900x650x160-16.00kg SDU B-V - 9 loops 900x650x160-16.50kg SDU B-V- 10 loops 900x650x160-17.00kg Measurements SDU B-V KITS 2 loops 800x800x760-40.50kg 3 loops 800x800x940-51.50kg 4 loops 800x800x1120-62.50kg 5 loops 800x800x1300-74.50kg 6 loops 1300x800x790-88.50kg 7 loops 1300x1000x790-99.50kg 8 loops 1300x800x970-110.50kg 9 loops 1300x1000x970-121.50kg 10 loops 1300x800x1300-132.50kg
SDU Z-P-V 4 loop KIT As a Zone Heating System Standard Distribution Unit assembled with: Circulation pump 25W 230V Control box includes terminals Air release valve Made of 1 stainless steel An adjustable flow meter for each loop Each loop includes mechanical valve activated by 230V Actuator to open and close water flow in each loop (The actuator is controlled by a thermostat placed in each room) Suitable for 16/2mm Pro-Pipe Mounted in a metal cabinet The Kit includes: SDU-Z-P-CU Manifold Pro-Pipe 16/2mm made of Pro with an oxygen barrier layer Length per loop 90m 2 Each loop covers approx. 12m when spaced at 15cm Clamping rings of 3/4 for 20/2 connection pipe 0 90 Black Angle X 2 per loop Hooks: 180 units per loop Thermostat optional Measurements SDU Z-P-V KIT 800X800X990-65kg Measurements 530X500X110-13kg The mater ials in this page, m ay not be repr oduced, photocopied, displayed, m odified or
SDU AS P V ET 5-8 WL Standard Distribution Unit assembled with: 6-10 loops For each loop: Adjustable Flow Meter and Actuator NC (normally closed) 230V 50-60Hz Circulating Pump RS 15/6 S 45-67-93W Pressure Gauge Wireless (RC) system for individual room temperature control. Use frequency 868MHz Expansion Tank 2 liters Air Release Valve Manifold made of 1 stainless steel Suitable for 16/2mm Dowlex-Pipe or Oval DowlexPipe 25/17/2.5mm Mounted in the header cabinet 750x610x140mm Completed with wireless thermostats and subcontrols thermostats SDU AS P V ET 5-8 WL can be connected to all hot water source suitable for underfloor heating : Climateck booster Heat pump air/water Any other hot water source Measurements SDU AS P V ET 5-8 WL 8 loops - 750x610x140 (mm) - 23kg Wi-fi sub-control Thermostat + 16/2 Pro pipe Elbow with round connection pipe to manifold + Wi-fi sub-control thermostats All The mater ials in this page, m ay not be repr oduced, photocopied, displayed, m odified or pictures & graphics are for
ADU 1-2 3X4/8 KIT A Stand alone system with electrical heating element or can be connected to an existing heating source Up to 12m 2 for one large area or a few small rooms Active Distribution Unit assembled with: Circulating Pump 25W 230V Pressure Gauge Mini-Tank made of stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 13 Amp 3X1000W Control Box includes terminals Flow Valve to allow hot water to themanifold and the Pro-Pipe mat Coupling System especially for the 8mm Pro-Pipe Mounted on a 1.5mm metal sheet Covered by ABS casing Measurments: 490x520x120 11.5kg Pro Pipe Mat: 8mm Pro loops integrated onto mats Mat size 0.50x6.0 Each mat covers 3m 2 90 0 Black Angle x 2 per loop Thermostat: CU 518MF To control the water temp. in the manifold On/Off Switch The Kit includes: ADU 1-2 4X3/8 4 Pro-Pipe mats CU 518-MF Packaging measurments: 520x540x650-33kg Advantages: Energy saving Low temperature floor heating (max.45 C) Easy to install Built up of only 10mm floor height pictures & graphics are for All
ADU 1-2 4X4/8 KIT A Stand alone system with electrical heating element or can be connected to an existing heating source Up to 16m 2 for one large area or a few small rooms Active Distribution Unit assembled with: Circulating Pump 25W 230V Pressure Gauge Mini-Tank made of stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 13 Amp 3X1000W Control Box includes terminals Flow Valve to allow hot water to the manifold and the Pro-Pipe mat Coupling System especially for the 8mm Pro-Pipe Mounted on a 1.5mm metal sheet Covered by ABS casing Measurments: 490x520x120 11.5kg Pro Pipe Mat: 8mm Pro loops integrated onto mats Mat size 0.50x8.0 Each mat covers 4m 2 90 0 Black Angle X 2 per loop Thermostat: CU 518MF To control the water temp. in the manifold On/Off Switch Advantages: Energy saving Low temperature floor heating (max.45 C) Easy to install Built up of only 10mm floor height The Kit includes: ADU 1-2 4X4/8 4 Pro-Pipe mats CU 518-MF Packaging measurments: 525x540x650-33kg
ADU 3-4 4X90/16 Loop KIT Active Distribution Unit assembled with: Circulation Pump 25W-230V Pressure Gauge Mini-Tank made of 1 stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 15.6 Amp 3X1200W Control Box includes Terminals Flow Valve to allow hot water to the manifold and Pro-Pipe Coupling System especially for 16/2mm Pro-Pipe Mounted on a 1.5mm Metal Sheet The Kit includes: ADU 3-4 Manifold 4 x 16/2mm Pro-Pipe loops Length per loop 90m Each loop covers approx. 12m 2 CU 518-MW to control the water temp. in the manifold 90 0 Black Angle X 2 per loop Hooks: 180 units per loop Thermostat optional Measurements ADU 3-4 4X90/16 KIT 800X800X1005-65kg Measurements 490X520X120-13kg
ADU 5-8 ADU 5-8 loop can be connected to ACU s or to pro-pipes in the floor. Designed to warm areas up to 100m 2 (1000sqf) Active Distribution Unit assembled with: Mini Tank 4kW or 6kW Electrical Heating Element* Expansion tank Manifold with flow meter Pressure Gauge Thermostat to control the water temperature. Metal mounting plate Plastic Cover *Can be assembled with different heating elements depending on the number of loops required. Your electrician can change the output of the heating element (see instruction of installation) Operation voltage Whirl pump power Whirl pump ingress protection Operation pressure Max. water temp. Capacity of Mini-Tank 3X 230V AC 50Hz EV+20-6/130 6-50W IP44 3.5 bars 40 C(CU 510); 55 C(XR 20CX) 1.5L ADU 5 LOOPS ADU 6 LOOPS ADU 7 LOOPS ADU 8 LOOPS Coverage area (m²) 65-75 72-84 84-98 96-002 Dimensions (mm) 655X755X035 655X755X035 655X955X035 655X955X035 Power of electrical unit (kw) 3X0555 3X2555 3X2555 3X2335 Wight (kg) 25 2015 22 22
ADU 2M 2L 2x6kW Active Distribution Unit assembled with: Circulating Pump 25W 230V Pressure Gauge 2Mini-Tanks made of stainless steel with each heating element Manifold 3/4' made of brass Expansion Tank Electrical Unit 13 Amp 3X1000W Control Box includes terminals Flow Valve to allow hot water to the manifold and the Pro-Pipe mat Mounted on a 1.5mm metal sheet Covered by ABS casing 2 Loops Connected to interface
ADU 2M 10L Active Distribution Unit assembled with: Circulating Pump 25W 230V Pressure Gauge 2Mini-Tanks made of stainless steel with each heating element Manifold 3/4' made of brass Expansion Tank Electrical Unit 13 Amp 3X1000W Control Box includes terminals Flow Valve to allow hot water to the manifold and the Pro-Pipe mat Mounted on a 1.5mm metal sheet Covered by ABS casing Up to 10 Loops Connected to interface Adapted to Pro-pipes 16/2, but can be used with pro-pipes 20/2
Heat Pump VOP HX 24,000 Btu Description & Features: Heat exchanger Connects to ADU with Pro Pipe SP. Increases the efficiency of the system. Refrigerant R410A. Variable output (17,000-35,000) Quiet and maintenance free TECHNICAL DATA: Characteristics Operation voltage 17,000-35,000 Btu 230V1Ph/50Hz Input Power (W) Cooling Heating C.O.P (W/W) Refrigerant Noise Level (dba) Weight (kg) Indoor/Outdoor Dimensions (mm) 1850W 1650W 3.7 R410a/1.330kg 56 52kg 550x280x900 Indoor Unit Air Flow Rate (m³/h) Piping Connection 1040m3/h BSSP 3/4 Nominal Capacity BTU/h Cooling 50000W-17060Btu Heating 60000W-20750Btu
Heat Pump B 18 HX Description & Features: Air to Water Heat pump for floor heating and acclimatization systems Connects to ADU with Pro Pipe SP. Increases the efficiency of the system High efficiency plated heat exchanger Ozone friendly refrigerant R410A Quiet and maintenance free Control the temperature of the water is done through Climateck control box with CU 535 Heat pump B Hx + ADU Heat pump B Hx + SDU Z B 5-8 TECHNICAL DATA: Type HP-18 Hx Function Cooling Power supply Capacity Heating 220-240V/50Hz 1Ph Cooling (heating )capacity KW/h 5.0 6.0 BTU/h 17060 20470 Heat pump B Hx + SDU AS P HP 02 Maximum current allowable A Operation current A 8 7.2 Input power W 1850 1650 COP W/W EER Efficiency of power supply W/W % Current of fan motor A Electric Data Dimensions Outdoor unit Weight Outdoor unit Others 3.7 2.7 1. Rated condition of test: 99 Width mm Outdoor: 0.33 955 Height mm 555 Depth mm 295 Kg 52 Noise Outdoor unit db (A) 56 Fan speed Outdoor unit Rpm 855 Refrigerant g 1.330/R410A Water Pipe connector tread BSPP 1/2 internal Rated Water Flow L/h 864 Outdoor discharge temp. sensor KΏ 100K (25 C) Cooling: Water in/out temperature: 12 C/ 7 C Outdoor dry bulb 35 C wet bulb 24 C Heating: Water in/ out temperature:30 C/ 35 C Outdoor dry bulb 7 C wet bulb 6 C 2. The specification are subject to change without prior notice For actual specifications of the unit please refer to the specification stickers on the unit. The mater ials in this page, m ay not be repr oduced, photocopied, displayed, m odified or
Heat Pump-B Description & Features: Connects to the Standard Energy Unit with copper pipes. Increases the efficiency of the system. Controlled by CU 535 (supplied with EU). Quiet and maintenance free Heat pump B + Standard Energy Unit TECHNICAL DATA: Characteristics 18000 Btu 24000 Btu 36000 Btu Operation voltage Power of electrical unit 230V AC 50Hz 230V/ 50HZ/ 230V AC 50Hz 230V/ 50HZ/ 230V AC 50Hz 230V/ 50HZ/ Heat pump B + Interface 1PH/ 1930W 1PH/ /2600W 1PH/4000W C.O.P 2.7 2.7 2.7 Refrigerant R410A R410A R410A Noise Level (dba) 40 64 67 Weight (kg) 44 45 77 Dimensions (mm) 870x320x540 900x350x600 960x430x790 Air Flow Rate (m³/h) 750 1050 1050 Gas Valve (inch) 1/2;1/4 5/8;3/8 3/4;3/8 Adapted to areas (m²) 50-80 80-90 100
Interface C System Control Box Description & Features: Connects to Climateck s Heat Pump-B (Btu 24000-36000) Increases the efficiency of the system Refrigerant R410A Quiet and maintenance free TECHNICAL DATA: Characteristics Power Supply Nominal Cooling Capacity Nominal Heating Capacity Type Heat Exchanger 36000 Btu 220-240V / 50-60Hz 32000 Btu-9.37kW 36000 Btu 10.54kW High Efficiency Tub in Shell Water Piping Connection Water Pressure Drop Max. Water Flow Dimensions (LxDxH) Net Weight Refrigerant piping Connection Water Pump Type IP44 TF 110 C, Class H G3/4 8 kpa 2.5m 2 /h 500x520x210 24.5kg R410A 3/8 ; 1/2 GPD 25-8S 135;190;225W
Manifold for Interface
Standard Energy Unit Designed for Floor Heating & Cooling up to 100m 2 The Standard Energy Unit connected to the Heat Pump-B is a basic part of the acclimatization system and is ideal for water based floor heating and air cooling. Description & Features: The Standard Energy Unit is connected to Heat Pump-B Ideal for water based under floor heating and also for air cooling & heating. Operated by CU HA-535-S, which controls the water temperature (30 C-45 C) in the Mini Tank and the Heat Standard Energy Unit+ Heat pump-b Pump-B condenser temperature. TECHNICAL DATA: Characteristics Operation voltage Power of electrical unit Whirl pump power Whirl pump ingress protection Operation pressure (Bar) Max. water temp. Dimensions (mm) Weight (kg) Capacity of Mini-Tank (L) Refrigerant PDU ingress protection Standard Energy Unit 230V AC 50Hz 230V - 6kW - 14A 65W IP44 3.5 45 0 C (Max) 750x650x110 20 1.5 R410A IPX3 Double Protection against OVER HEATING 1. GFCI (RCD) Thermal Switch NO (75 C) 2. Thermal Switch NC (60 C)
ACU - Floor OS Description & Features: The Climateck ACU - Floor OS integrates the air circulating system with a heating system in a single terminal In winter it is silent as a radiator, but offers a much higher performance In the summer it is an exceptional air conditioner, that cools and dehumidifies Extra thin dimensions that makes it suitable for any context (less than 13cm depth). Can be operated on 3 different speeds of air flow Very low noise level 9000 Btu Includes a remote control TECHNICAL DATA: Characteristics Operation voltage Electric Power Operation pressure (Bar) Water Flow / Hour (L) Noise Level (dba) Weight (kg) Dimensions (mm) Air Flow Rate (Min. - Max. in m³/h) (9000 Btu) 230V AC 50Hz 55W 3.5 300 <38 20 719x 897 x 129 155-320 (12000 Btu)
ACU Wall Description & Features: Controlled water temperature, heated or cooled by the Energy Unit & Heat Pump-B is constantly circulated in the copper pipes of the ACU (Air Circulation Unit) Includes a filter which will maintain a clean and dust free environment Can be installed on walls at heights that will still give architects the advantages as in floor heating systems. Gently and quietly circulates the air at a speed set by the home owner Includes a remote control The ACU has 3 speed air flow with temperature control 9555 or 12000 are available Very low noise level TECHNICAL DATA: Characteristics Operation voltage Electric Power Operation pressure (Bar) Water Flow / Hour (L/h) Noise Level (dba) Weight (kg) Dimensions (mm) Nominal Air Flow Rate (m³/h) 9000 Btu 230V AC 50Hz 35W 3.5 468 <40 11.5 840 x 320 x 260 493 12000 Btu 230V AC 50Hz 35W 3.5 576 <40 13 900 x 320 x 260 697
ACU Wall Tadiran Description & Features: TECHNICAL DATA: Characteristics Operation voltage 16000 Btu Electric Power Operation pressure (Bar) Water Flow / Hour (L/h) Noise Level (dba) Weight (kg) Dimensions (mm) Nominal Air Flow Rate (m³/h)
ACU Concealed 12000 Btu-15000 Btu
WBS Accessories Pipes Description Oval Pipe DOWLEX Orange Made of Dowlex with oxygen barrier layer 17 x 24 x 2.5mm in rolls of 200m Welding Nipple To connect the Oval Pipe Manifold Connection 21 x 2.5mm round pipe with 90 Bow Oval Elbow 90 Round/Oval Connection between 21 x 2.5mm Round Pipe and Oval Pipe Manifold Connection Pipe OV-AR 21 x 2.5mm - Length 1.0m Red Elbow 90 Oval/Oval To connect the Oval Pipe to cross vertical level differences Copyright 2006-2010 All rights reserved. www.decoragroup.com wwwdomoteck.com & all related companies The materials in this page, may not be reproduced, photocopied, displayed, modified or A l l p i c t u r e s & g r a p h i c s
WBS Accessories Systems Description SDU 3 Loops SDU 4 Loops SDU 5 Loops Plated Metal Sheet: 3 Loops - 250mmx450mm 4 Loops - 300mmx450mm 5 Loops - 350mmx450mm Header Cabinet For built-in installation made from Galvanized Sheet Metal Front powdered white RAL 9010 Available in 3 sizes - Dimensions on request Pro-Pipe Description Pro-Pipe 8/1.2 mat 0.5 x 2.0 = 1.0 Pro-Pipe 8/1.2 mat 0.5 x 4.0 = 2.0 Pro-Pipe 8/1.2 mat 0.5 x 6.0 = 3.0 Pro-Pipe 8/1.2 mat 0.5 x 8.0 = 4.0 Pro-Pipe 8/1.2 Made of Pro with an oxygen barrier layer In rolls of 200m Pro-Pipe 16/2 - Made of Pro with an oxygen barrier layer In rolls of 90m & 200m Copyright 2006-2010 All rights reserved. www.decoragroup.com wwwdomoteck.com & all related companies The materials in this page, may not be reproduced, photocopied, displayed, modified or A l l p i c t u r e s & g r a p h i c s a r e f o r i l l u s t r a t i o n o n l y
Basic hydronic accessories Components Description Filling &Draining Valve To be installed at the end of the water inlet & water outlet bar Blind Cap 3/4 - To close a not needed outgoing & in going circuit. Connector Nipple 3/4 Eurocone Nickel Plated to be installed at the Blank Port to add additional loops Regulating Valve To be installed in the water outlet bar Thermostatic Valve To be installed in the water inlet bar Ball Valves - R1, Brass Nickel Plated Flow Meter - Balancing Valve Direct regulation, reading & shut-off of flows in systems Pipe Fitter - Consisting of cap nut 3/4 Clamping Ring & Pipe Spout. To fix the Round Pipe to the manifold by 3/4 Euro cone. 16mm (16 x 2.5mm round pipe) (17mm (17 x 2.5mm round pipe) 20mm (20 x 2.5mm round pipe) WBS-FRC Unit - Electrostatical Valve. Thermostat to open & close valve Sensor + Sensor Tube Black Angle 90 x 1 per loop Domo RTL AC WB 723 Installation Box RTL AC WB 727 Copyright 2006-2010 All rights reserved. www.decoragroup.com wwwdomoteck.com & all related companies The materials in this page, may not be reproduced, photocopied, displayed, modified or A l l p i c t u r e s & g r a p h i c s
Basic hydronic accessories Components Description CU HA 535-S Thermostat for Home Acclimatization Systems CU 520-SR Thermostat Actuator 230V type Alpha To open and close the water flow each loop Cable length 1m Terminal Strip 230V - To connect the Thermostat to the Actuators Ventilation 1/2 To be installed at the Blank Port as needed Header Cabinet H500xW530 For built-in installation made from Galvanized Sheet Metal Front powdered white RAL 9010 Available in 3 sizes Dimensions on request Copyright 2006-2010 All rights reserved. www.decoragroup.com wwwdomoteck.com & all related companies The materials in this page, may not be reproduced, photocopied, displayed, modified or A l l p i c t u r e s & g r a p h i c s
WBS Accessories Installation Description Black Angles - To help prevent the Pro-Pipe from breaking when connecting to the SDU-A. Hooks - To Fix the 16mm - 20mm Pro-Pipe to the Domo-ISO RJ system panel. Fixing Strips- For anchoring the 8mm/200m Pro-Pipe Domo-ISO RJ System Panel Insulation Panel with foil backing & printed grid - 50mm distances. Domo-ISO HP 1000x500mm AC WB 718 Domo-ISO HP 1000x500mm AC WB 711 Security Border Strip- 160 x 8mm with PE Strap to connect to the system panel. Polyethylene Foil- To lay over the insulation for separation from the concrete. Thickness -0.2 Width - 2.0 m Folded to 1m rolls of 35m. Tools Description Pipe Cutter - For cutting the Pro-Pipe to the required length of the loops. Stapling Machine - To insert the hooks with the Pro- Pipe to the Domo-ISO RJ System Panel. Copyright 2006-2010 All rights reserved. www.decoragroup.com wwwdomoteck.com & all related companies The materials in this page, may not be reproduced, photocopied, displayed, modified or A l l p i c t u r e s & g r a p h i c s
Contact Information: info@domoteck.com www.domoteck.com