Installation Manual Premier Elite Orbit QD/DT INS483-2

Similar documents
Movement Detector GJD 300

D-TECT Dual Tech. GJD360 Triple Technology External Detector

D-Tect 2 GJD300 Quad PIR Movement Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Premier External TD. Installation Manual INS352-3

Installation Manual Premier Elite IXP-W

DI601AM Outdoor PIR/AM Detector Installation Sheet

D-TECT 3 IP. GJD260 IP Motion Detector

Installation Manual. Premier IXP-W INS538

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

D-TECT 2 IP. GJD230 IP Motion Detector

Intrusion Outdoor Protection Perimeter

Installation Manual. Odyssey X Series INS627-2

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

International Customer Edition Date: June 2014

LUX Hardwired - Installation Notes

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Description. Optex Incorporated

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Installation and Operation Manual

English. Italiano. Português. Françias. Español

Advanced DIGITAL Wired PIR Motion Detector

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Intrusion. Outdoor protection perimeter

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Commercial Series TriTech Motion Detector. Reference Guide

English. Series. Installation and Use Manual

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

EWP2WIRELESS MOTION DETECTOR

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

LPCMPIRM65 & LPCMPIRDSI65

HX-80NRAM. High Mount Outdoor Detector

Active Infrared Multi Beam Sensors

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Active Infrared Multi Beam Sensors. R Series

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Installation Instructions

Extended Range DUAL TEC Motion Sensor

LS800S Intruder Alarm System. Engineering Manual

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

PQS performance specification

Ceiling PIR HS presence detector. Product Guide. Overview. Features

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

BFD Light Curtains The new choice for cutting edge safety for industrial doors

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

FEC403EN Installation Manual

Sensors. Supplied by: User Interfaces. Networked Controls Product Catalogue

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Commercial Series TriTech+ Motion Detector with Anti-mask

Flash 3 times per 3 seconds: Under voltage indication, please

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

LeakSafe. solutions. WaterSwitch2. Installation Instructions

External Wireless Sounder

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

Premium 8 Zone Wireless Alarm Kit

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

This document is a preview generated by EVS

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Polycarbonate External Sounder & Strobe Unit

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

English version. Alarm systems Terms and definitions

Ceiling Microwave presence/absence detector 12-24V AC/DC

Door Release Power Supply

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

PRODUCT GUIDE Electronic Perimeter Detection & High Performance LED Illumination

Masthead Repeater Installation Handbook

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Radiance Electric Range

2G & 3G GSM Portable PIR Alarm

KFP-CF Series Operation Manual

, ,

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Installation Instructions

Hardwired Alarm Accessories

EnvironmentalMonitoring

EU directives WEEE and RoHS. Information and notes

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Bosch Smart Home. Motion Detector Instruction Manual

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Long-Range Barrier Sensors

This document is a preview generated by EVS

2-ZONE EASYFIT INTRUDER ALARM

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

Transcription:

Installation Manual Premier Elite Orbit QD/DT INS483-2

Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package and a microwave sensor. Both sensors have to trigger before the detector signals an alarm. This high precision, very reliable presence detector has been designed for use within CCTV installations. Programmable parameters include a pulse count feature and a choice of detection ranges from 10 to 30 metres. The integral dual axis tilt sensor allows 180 of pan and 90 tilt. This increases the speed of the outdoor installation and provides incredibly accurate aiming of the detection pattern. The electronics module is acrylic coated for additional component stability. It is encased in an ABS housing with a UV stabilised translucent front cover ensuring the sensor is impervious to and unaffected by weather conditions. Additionally the combination of precision electronics, digital white light filter and double shielding eliminates false alarms from the sun and other visible light sources. The Premier Elite Orbit design gives a neat and professional appearance with no visible indication of the orientation of the detector head, and totally hides the wiring. Quick Installation Guide Apply supply voltage to the unit, the blue LED flashes 3 times. The detector takes approximately 2-3 minutes to settle. The walk test LED is factory set to OFF. Pressing the program button once will enable the walk test LED for 5 minutes. THE FRONT COVER MUST BE FITTED WHEN WALK TESTING. FACTORY SETTINGS ARE:- 1 RANGE 30 METRES 2 PULSE COUNT 1 3 LED OFF When enabled the Premier Elite Orbit DT has three LED indicators. Green - Microwave detection Red - Both PIRs detection Blue - Alarm output, both PIRs and microwave detection 1 INS483-2

1. Mounting the Unit During installation the electronics must be protected against water, as trapped moisture can affect or damage the unit. Optional for Tamper Cup 1) Using the template provided drill the wall to 1 Cable Holes accept the two fixing screws, the cable entry and the tamper cup (if used). See fig. 1 and 2. Note: We recommend using the tamper cup on uneven wall surfaces. Fixing Holes Template 2) Remove the cover assembly by loosening the locking screw using the allen key provided. The cover hinges from the top and lifts out of the location slot. See fig. 3. Tamper Tamper 2 Foot Cup 3 4 Tamper Cup 3) Feed standard 8 core alarm cable into the cable entry; bare the wires and connect to the removable terminal block as shown in fig. 7. Screw the unit to the wall ensuring that the tamper pin is correctly located and that the tamper microswitch is closed. See fig. 4 and 5. To aid installation, two spare tamper feet are provided. One is 1mm longer and the other is 2mm longer than the tamper foot originally fitted. The tamper foot is a push fit and can be removed by carefully pulling it from the pin. See fig. 2. INS483-2 2

4) Always ensure when replacing the electronics module that the LED is facing forward so as to ensure correct alignment of the beam pattern. (Refer to section titled Multibeam Alignment & Masking ) 5) When the detector has been aligned to suit the installation, replace the front cover and lock as shown. See fig. 6. 5 6 2. Connecting the Unit 7 Tamper Connection Route 1 Alternative Route 2 Route 3 Not Recommended Normally Closed Tamper Circuit Front & Rear Alarm Connection 0V Supply 12VDC Supply Alarm Output 2 Multiplexer, PTZ Dome, DVR, etc. N/Open N/Closed Alarm Output 1 Multiplexer, PTZ Dome, DVR, etc. 3 INS483-2

3. Multibeam Alignment & Masking The multifunction lens fitted to the Premier Elite Orbit detector produces 7 long range beams and 7 medium to short range curtain beams. Movement across the beams produces the best response and range, whilst movement towards the detector will be less responsive. The unit detects the changes in heat and movement in the beam pattern, therefore items such as trees, shrubs, ponds, boiler flues and animals should be considered when positioning the detector. The detector module is fitted with two sliding shutters to reduce the detection angle. An additional set of curtains is provided should the beam pattern need to be narrowed even further, e.g. if the minimum detection angle of 10 degrees is required. The curtains are fitted to the pan and tilt module as indicated in fig. 8 below. Each section of the detector s lens gives a coverage pattern of approximately 10 degrees. See fig. 8. 8 9 INS483-2 4

3. Multibeam Alignment & Masking When mounting higher than boundary fences rotate the module and mask off any beams, either vertically or horizontally, that fall outside the area being covered. Use portions of the self-adhesive silver mask supplied to the rear, smooth side, of the lens as shown in the diagrams below. Always replace the lens the correct way up to ensure exact beam pattern coverage (the top of the Fresnel lens is marked - TOP). See fig. 9. (Page 4) *Premier Elite Orbit DT only * 5 INS483-2

4. Programming The user can individually program a number of configurable settings as illustrated in the programming chart. Factory settings are shown as shaded boxes. 10 Changes to the existing settings can easily be made. To reset the factory settings simply remove power form the detector, press and hold the program button (fig. 10) whilst temporarily applying power to the detector: either before installation, with a PP3 battery, or by applying 12 Volts to the unit on site. LED Program Button PROGRAMMING CHART SETTING 1 2 3 OPTIONS 1 RANGE METERS 10 20 30 2 PULSE COUNT 1 2 3 LED OFF ON To change any of the Premier Elite Orbit settings: - 1) Press the program button as shown in fig. 10 for the number of the Option to be changed i.e. once for range, twice for pulse count, three times for LED. 2) Wait four seconds until the blue LED indicator goes off. 3) The indicator will then flash out the existing setting. 4) To change the setting for that option, immediately (within 2 seconds) press the button the number of times required for the new setting. 5) The indicator blinks twice and the changes are stored. Any alterations made to the Premier Elite Orbit settings are stored in the detector s non volatile memory. EXAMPLE To change the LED Setting from OFF to ON. 1) Press the program button three times and release the button. 2) Wait until the indicator goes off. 3) The indicator will now flash once. 4) Press the program button twice and release the button. 5) The indicator flashes twice showing that the option has been stored and the detector returns to normal operation. INS483-2 6

5. Walk Test The range of the detector increases without the front protective cover. Therefore the front cover must be fitted to establish the correct beam pattern alignment and when testing the outputs. Use the program table on page 5 to adjust the range as necessary and pan and tilt the lens module over the field of view to obtain the correct coverage area. When the program button is pressed momentarily the blue indicator lights and pulse count 1 is automatically selected. The unit can then be aligned. The blue indicator will light on the Premier Elite Orbit every time a detection takes place. This test mode will automatically cancel five minutes after last detection. Alternatively, remove the power and then re-apply. 6. Walk Tester The Premier Elite Orbit Walk Tester is an installation tool that will help the installer set up the detector on site. Considerable time will be saved in the setup procedure when using the Walk Tester, and it s use is highly recommended. If you have difficulty in aligning the detector, and you have issues with either short or long ranging, a Walk Tester will assist greatly in correct alignment and performance. Each Premier Elite Orbit has been fitted with and infra-red LED emitter. When activation occurs the transmitter sends a signal. This signal is then received by the Walk Tester and a very bright white LED on the Walk Tester flashes, also a piezo speaker sounds. Under normal situations both the LED and the sounder can be seen and heard up to 50 meters. 11 LED Sounder Blue LED Premier Elite Orbit PCB WalkTester Holder WalkTester The Walk Tester comes with a mounting bracket / holder. First fit a PP3 battery into the Walk Tester battery compartment. This is done by removing the battery compartment cover. Please ensure that the on/off switch on the Walk Tester is set to the off position while connecting the battery. When fitted close the battery compartment and the Walk Tester is ready for use. Removing the Battery Cover 7 INS483-2

7. Using the Walk Tester Remove the cover from the Premier Elite Orbit housing by loosening the locking screw at the bottom of the detector. This will allow access to the programming button shown in Fig.11 (and to also to show the location of the blue IR emitting LED). Place the Premier Elite Orbit into walk test mode by pressing the programme button once (Fig.11). The Premier Elite Orbit s clear LED will then flash out its current settings. Wait for the flashing sequence to finish. The Premier Elite Orbit is now in walk test mode and will remain in that state for five minutes after the last detection, whereafter it will revert to normal mode. The walk test can be cancelled at anytime by pressing the programme button twice. Replace the Premier Elite Orbit cover and place the Walk Tester in the metal holder. Slightly loosen the stainless steel screw on the bottom of the Premier Elite Orbit, just enough so that the drilled tab on the Walk Tester bracket can slide around the screw thread. Then gently tighten the screw to hold the Walk Tester and holder in place. Turn the Walk Tester on. The Walk Tester will illuminate and sound every time the Premier Elite Orbit is activated. When finished testing, turn off the Walk Tester and remove it and the holder from the Premier Elite Orbit. Tighten the screw on the base of the Premier Elite Orbit. The external detector is now ready. 8. Option Definitions PULSE COUNT This is the number of times the unit has to detect on both of its sensors before signalling an output. LED MONITOR LED Off - LED disabled. LED On - LED signals a detection. N/OPEN & N/CLOSED These are magnetically immune volt free relay contacts used to trigger alarm inputs on connected equipment. The contacts are rated at a maximum of 24VAC/DC @ 50 ma. ACCESSORIES Texecom is able to supply the following accessories to aid installations: Pole mount bracket available on request. (JAH-0001) Premier Elite Orbit Walk Tester. INS483-2 8

9. Approved External Microwave Frequencies - Premier Elite Orbit DT Albania Argentina Australia Austria Belgium Brazil Croatia Czech Republic Denmark France Germany Greece Holland Hungary Iceland Indonesia Italy Latvia Lithuania Malta Norway Portugal Poland Russia Slovakia South Africa Spain Taiwan Thailand U.A.E UK Ukraine USA 9.35GHz 9.90GHz 10.525GHz 10.587GHz 9 INS483-2

10. Technical Specifications - Premier Elite Orbit DT Detection Area Coverage Adjustment Fresnel Lens Customised Optics Programmable between 10 & 30 metres. 10-70 degrees detection angle, 30 m x 30 m coverage max. 180 degree pan + 90 degree tilt. 28 zones for each pyro pair, which can be masked with the curtain sliders. Double silicon shielded quad element eliminates 50,000 lux of white light. Microwave Module Frequencies: 9.35GHz, 9.90GHz, 10.525GHz, 10.587GHz (see page 10) Outputs No.1 - N/OPEN No.2 - N/CLOSED Power Input Current Pulse Count 1-2. Temp. Compensation Control Walk Test Operating Temp. Housing Silent solid state magnetically immune. Volt free relay signal contact 24VAC/DC @ 50mA with an integral 25R series resistor. Alarm time 5 seconds. Volt free relay signal contact 24VAC/DC @ 50mA with an integral 25R series resistor. Alarm time 5 seconds. 9 to 15 VDC. 15mA (12V nominal). Digital sensitivity adjustment. Digital microprocessor - non volatile memory. Output test mode with LED indication. -20 to + 55 C. Conformally coated electronics for increased stability. ABS. Protection Rating lp 55. Dimensions Weight Mounting Height Cable < 200m Cable < 500m 141 x 165.5 x 109 mm. 300 grams. Variable up to 6 metres - optimum height 3 metres. Utilising all three outputs (incl. tamper) 8 core 7/0.2mm. Utilising all three outputs (incl. tamper) 8 core 16/0.2mm. Regulatory Information Supplier: Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK. Weee Directive: 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom declares that this device does not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers (PBDE) in more than the percentage specified by EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EC annex. CE Directive: 2004/108/EC (CE directive): Hereby, Texecom declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. Maintenance: Test yearly by the installer Warranty: 2 year replacement warranty The Premier Elite Orbit detector is not a complete alarm system, but only its part. Therefore Texecom does not accept any responsibility or liability for any damage that is claimed to be a result of an incorrect functioning of the Premier Elite Orbit detector. Texecom reserves the right to change the specification without a prior notice. Certificate Number: FM 35285 MADE IN ENGLAND The Premier Elite Orbit detector is protected by UK & International Designs. Premier is a Trademark of Texecom Ltd. INS483-2 10

11. Technical Specifications - Premier Elite Orbit QD Detection Area Coverage Adjustment Fresnel Lens Customised Optics Outputs No.1 - N/OPEN No.2 - N/CLOSED Power Input Current Pulse Count 1-2. Temp. Compensation Control Walk Test Operating Temp. Housing Programmable between 10 & 30 metres. 10-70 degrees detection angle, 30 m x 30 m coverage max. 180 degree pan + 90 degree tilt. 28 zones for each pyro pair, which can be masked with the curtain sliders. Double silicon shielded quad element eliminates 50,000 lux of white light. Silent solid state magnetically immune. Volt free relay signal contact 24VAC/DC @ 50mA with an integral 25R series resistor. Alarm time 5 seconds. Volt free relay signal contact 24VAC/DC @ 50mA with an integral 25R series resistor. Alarm time 5 seconds. 9 to 15 VDC. 8mA (12V nominal). Digital sensitivity adjustment. Digital microprocessor - non volatile memory. Output test mode with LED indication. -20 to + 55 C. Conformally coated electronics for increased stability. ABS. Protection Rating lp 55. Dimensions Weight Mounting Height Cable < 200m Cable < 500m 141 x 165.5 x 109 mm. 275 grams. Variable up to 6 metres - optimum height 3 metres. Utilising all three outputs (incl. tamper) 8 core 7/0.2mm. Utilising all three outputs (incl. tamper) 8 core 16/0.2mm. Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at 3.36 pence per minute from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1278 686197 Email: techsupport@texe.com Texecom Limited 2011. INS483-2