AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Similar documents
Installation, Operation and Maintenance Manual

aquilar - leak detection solutions

aquilar - leak detection solutions

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

AquiTron. AT-WM Water Monitor DATA SHEET

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

AT-G-DETECT Gas Sensing System

TraceTek TT1000 Modular Sensing Cable

AT-G-SENSE Gas Sensing System

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Water Detection Controllers

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Industrial Strength Leak Detection

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Sensor Interface Module Installation/Operation Instructions

TTSIM-1 Sensor Interface Module

Macurco HD-11 Hydrogen Gas Detector

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Warranty Registration

KM300 Carbon Monoxide Detection System Installation Manual

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

TraceTek Leak Detection

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

TE Connectivity's AMP NETCONNECT Cable Management

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

PT9420 (Extended Range)

LOW PRESSURE Intrinsically Safe Transducer AST44LP

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

Cable Actuated Sensor Industrial Incremental Encoder Output

Model 4001 Series Single Channel Controller

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Installation, Operating and Maintenance Manual

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

1022 R/T Remote Monitor

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Protocol Station Remote Alarm

C Electrical Connection Kit

4100U City and Relay Cards Installation Instructions

RAM3 Remote Alarm Module

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

PT9150 (Extended Range)

LMA LINE MONITOR ALERT USER S MANUAL

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

INSTALLATION INSTRUCTIONS

Infrared Thermometer

Cable Actuated Sensor Industrial User Scalable VDC Output

Active Infrared Multi Beam Sensors

QuickStat-TC Installation & Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Beacon 800 Gas Monitor Operator s Manual

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Single Station Remote Alarm

HM1520LF Relative Humidity Module

Active Infrared Multi Beam Sensors. R Series

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Power Supply Display Module PSDM. Installation and Operation Manual

OPERATION MANUAL MODEL 805 ACCELEROMETER

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

PT9600. Cable Actuated Encoder Reel. General. Environmental

OPERATION MANUAL MODEL & ACCELEROMETER

ACCS-30. Multipoint commercial heat-tracing control system

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

M5200 Industrial Pressure Transducer

ACL TC 200 TEMPERATURE CONTROLLER

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

! "! # Please read these installation and operating instructions completely and carefully before starting.

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Cable Actuated Sensor Industrial User Scalable 4 20mA

M7100 Pressure Transducer

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Beacon 410A Gas Monitor Operator s Manual

RE-PR3-E-27 3-Phase Panel Mount 27kW

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

P125 High Pressure Sensor

Raychem Heating System

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

DP86 Constant Voltage with Fitting

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Transcription:

AquiTron Liquid Detection Module INSTALLATION INSTRUCTIONS

Please read these instructions carefully and keep them in a safe place (preferably close to the module) for future reference. These instructions must be followed carefully to ensure proper operation. A. GENERAL INFORMATION The single zone alarm has been designed for use with TraceTek sensing cables (TT1000, TT3000, TT5000, TT5001 and TT7000 sensing cables) although a special AquiTron leader & end termination will be required. The can monitor up to 45 m (150 ft) of sensing cable, or 10 water detection probes - optical probes, float switches and level indicators can also be incorporated into the system. STORAGE Keep the module in a dry place prior to installation to avoid possible damage to internal components. B. PRODUCT INFORMATION 24 24v ac/dc 24-S 24v ac/dc with sounder 230vac -S 230vac with sounder POWER CONSUMPTION 24v option 50mA 230v option - 11mA RELAYS Number: 1 x Leak Type: SPDT Rating: 5 A at 230 Vac/24 Vdc TEMPERATURE Operating: 0 C to 50 C (32 F to 122 F) HUMIDITY 0-90% (non-condensing) ORDINARY AREAS TheLDMisapprovedforuseonlyinordinary areas. APPROVALS Electromagnetic compatibility (EMC) Installation Category IEC 664 Category II Pollution Degree IEC 664 Degree 1 24v Connection Diagram 230V Connection Diagram 1

C. SELECT A MOUNTING POSITION Choose a location indoors where the module will be protected from the elements and temperature extremes WARNING: Ignition hazard. Do not mount the unit in a hazardous location. Sensing cable connected to the may (subject to approvals restrictions) be located in hazardous locations, but the module itself must PREPARE THE MODULE FOR MOUNTING Important: The LDM is an electronic unit. During installation, take the following precautions to avoid damage to its electronic components: Handle with care, avoid mechanical damage. Keep the electronics dry. If handling circuit boards, hold them by their edges to avoid physical contact with electronic components. Avoid exposure to static electricity. Avoid contamination with metal filings, liquids, or other foreign matter. D. PREPARE SENSING CABLE/SENSING PROBE/DEVICE Ensure that the sensing cable (sensing device) has been installed in accordance with the instructions provided. Note; the specific wiring of the sensing device into the LDM. MAKE CONNECTIONS Feed the end of the leader cable (or jumper cable) through the adapter/bushing. Using TraceTek sensing cables, connect only the Black and Green to the SENSOR terminals 1 + 2. 1 Black 2 Green Note: The sensing circuit is power limited, so the leader or jumper cable and the power supply cable must not run in the same conduit. Fit conduit bushings / adapters as required. CONNECT THE ALARM RELAY The has one alarm relay, which is type Form C relay contacts, normally open, normally closed and common. The relay is energised to indicate an alarm condition. Note: The terminals can accept wires 1.5mm2 cable conductors, care must be taken not to over tighten the terminals. Cable should have a temperature rating of 65 C. Note: Maximum load for relays is 5 amps. SENSITIVITY ADJUSTMENTS Adjust the sensitivity to suit the conductivity of the water and the sensing cable system length. Testing with the testing brush (mapping Tool) will only prove the alarm functions. N/C N/O C END OF LINE (END TERMINATION) When using TraceTek sensing cables, the end termination should be left off, alternatively a special LDM-MET end termination is available. 2

VOLT FREE RELAY OPERATION All leak detection alarm panels supplied by Aquilar are provided with, at least one, volt free relay.these are also known as volt free contacts or dry contacts. They are used to operate auxiliary equipment such as valves, sounders, pumps, beacons etc., sending closed or open contact signals to Building Management Systems (BMS) or other logic level controls. As the name suggests, there is no voltage present at the terminals. So, to operate a valve, for example, you need to have a dedicated power supply which is then fed through the relay (typically the live feed) to switch it on or off accordingly.typical wiring is as follows: Please ensure that the load does not exceed the ratings of the volt free relay. This is stated in the relevant product s data sheet / installation instructions. Wiring of volt free relays should be undertaken by a suitably qualified technician and in accordance with the regulations and standards in their industry/country. These notes are only intended as a guide and Aquilar Ltd bears no responsibility for the installation or operation of the unit. E. CONNECTING THE POWER CABLE AND RELAYS CONNECTING THE POWER WIRING Pass the power cable through the adapter/ bushing as fitted. Connect the power supply wires to the two-pin terminal block observing the polarity. The electrical supply should be fused at no more than 3 amps via an un-switched fused spur adjacent to the unit. (230v version only) Note: The terminals can accept wires 1.5mm2 cable conductors, care must be taken not to over tighten the terminals. Note: Do not exceed maximum voltage. 3

F. TESTING THE MODULE TEST AFTER SUPPLYING POWER When power is supplied, the green LED illuminates. Place water or on the probe or sensing cable and the LDM should report an alarm condition. Adjust the sensitivity to suit the conductivity of the water and the sensing cable system length. Testing with the testing brush (mapping Tool) will only prove the alarm functions. Verify that the red Alarm LED is illuminated. The Buzzer (if fitted) will sound and will only be silenced when the probe or sensing cables are dried. If unit still does not appear to operate properly contact your supplier for assistance. Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Aquilar Limited makes no warranty as to the accuracy or completeness of the information, and disclaims any liability regarding its use. The only obligations of Aquilar Limited are those in the Aquilar Standard Terms and Conditions of Sale for this product, and in no case will Aquilar Limited be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product. Specifications are subject to change without notice. In addition, Aquilar Limited reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. AquiTron is a trademark of AquiTron Limited Aquilar is a trademark of Aquilar Limited 4 V1 1.2018