READ AND SAVE THESE INSTRUCTIONS

Similar documents
READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

STEAM DISTRIBUTORS ASD / BSD / CSD. Installation Manual C

Steam Distribution. Installation Manual. Includes installation instructions for steam distributions ASD/BSD/CSD/RSD/SSD.

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

OPERATION AND MAINTENANCE MANUAL. Electrode Steam Humidifier Nortec EL Series

EN 1508 OPERATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling

NHRS Series RESISTIVE ELEMENT STEAM HUMIDIFIER. Engineering Manual. Manual No. H

Installation, Operation, Maintenance, Spare Parts, and Exploded Views Guide

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

MH Series EVAPORATIVE HUMIDIFIER/COOLER. Installation Manual A

READ AND SAVE THESE INSTRUCTIONS

Help. Help Software Tutorial. Building a Load Sizing Project with an SETC Humidifier and a mini SAM-e Distributor

I EN 1811 INSTALLATION MANUAL. Steam humidifier Condair EL. Humidification and Evaporative Cooling

Condair CS 2.0/4.0. Resistive Humidifiers INSTALLATION AND OPERATING INSTRUCTIONS. HLK Version HLK EN 1408

C EN 1707 INSTALLATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling

_C_EN_1612 INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Blower Pack Condair BP. Humidification and Evaporative Cooling

SETC Outdoor. Supplemental Installation and Spare Parts Manual

INSTALLATION MANUAL. Gas-fired Steam Humidifier Nortec GS. IMPORTANT! Read and save these instructions. This manual to be left with the equipment.

Quick Start Installation Guide

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

IMPORTANT! Read and save these instructions. This manual to be left with the equipment.

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

(HSTAT Series) Instruction Manual

Introduction... 1 System Overview... 1 System Diagram... 2

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

ion Genesis Pump Controller

Installation, Operation & Service Manual

52 BAYTOWNE CEILING FAN

INSTRUCTIONS AND WARRANTY

Technical Manual. LeakFilm Sensor. Film Type Liquid Leak Detection Sensor

52 SAN LUCAS CEILING FAN

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTRUCTION MANUAL P Heating and 1 Cooling

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

MN908 No. 282C Replaces 282B LB7013

52 BARSTOW CEILING FAN

Installation, Operation, Maintenance, Spare Parts, and Exploded Views Guide

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

52 STRATHMERE CEILING FAN

OPERATION & INSTALLATION MANUAL

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

FW-RA-LED Remote Multiplex Annunciator Panels

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Installation Instructions

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

CD6102 / CD6102 OC / CD6102-2

OPERATING INSTRUCTIONS

Installation and Operations Manual

Four Post Boot & Glove Dryer

aquamanta the experts in aquatic technology

READ AND SAVE THESE INSTRUCTIONS

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

CVS Model Inline Multi-Port Ventilators

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Installation Instructions

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

SEALING FIBER SEALING COMPOUND

Environmental Monitoring SmartSlot Card

Protégé Eclipse LED Keypad User Manual PRT-KLES

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Preamplifier Power Supply PPS-02 user's guide

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

HotPoly Tote Tank / IBC Heaters (TTH Series)

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Duct Mount. Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

Ceramic heater FAN. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Outdoor Steam Humidifier Nortec EL / RS

IntelliDoX Operator Manual

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

RAM3 Remote Alarm Module

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

Installation and Operation Instructions 1000 Series Siren & Controller

Radiant Thermostat 519

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Automatic Phone-Out Home Monitoring Systems

Document No

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

PM100/PM100E PLANTER MONITOR. Operator s Manual

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

Industrial Vacuums, Inc

RTO. User guide 05/

3-way switching valve

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

Transcription:

2591830 EN 1710 READ AND SAVE THESE INSTRUCTIONS This manual must be read in conjunction with Nortec ME Control installation manual and operation manual! ADDENDUM MANUAL Adiabatic air humidification/air cooling system RO Leak Detection Option for Nortec ME Control Humidification and Evaporative Cooling

Thank you for choosing Nortec Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY): Location ref.: Model: Serial number: Proprietary Notice This document and the information disclosed herein are proprietary data of Nortec Plc. Neither this document, nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Nortec Plc, except to the extent required for installation or maintenance of recipient's equipment. Liability Notice Nortec Plc does not accept any liability due to incorrect installation or operation of the equipment or due to the use of parts/components/equipment that are not authorized by Nortec Plc. Copyright Notice Nortec Plc, All rights reserved Technical modifications reserved

Contents 1 Introduction 4 1.1 Notes on the addendum manual 4 2 For your safety 5 3 System overview / Principle of operation 7 3.1 Overview RO leak detection system 7 3.2 Scope of delivery 8 3.3 Principle of operation 9 4 Installation work 10 4.1 Installing leak detector into control unit (retrofit parts only) 10 4.2 Connecting the sensors 16 4.2.1 Preparing the sensor cables 16 4.2.2 Connecting the sensor cables to the sensors 16 4.2.2.1 Wiring layout for systems with 2 sensors 17 4.2.2.2 Wiring layout for systems with 3 sensors 18 4.2.3 Fixing the sensors to the AHU floor or building floor 20 5 Configuration 21 5.1 Configuration process 21 6 Operation 22 6.1 Functional tests 22 6.2 Display and operating elements of the leak detector 23 7 Spare parts 24 8 Appendix 25 8.1 Wiring diagram for RO leak detection systems with 2 sensors 25 8.2 Wiring diagram for RO leak detection systems with 3 sensors 26 Contents 3

1 Introduction 1.1 Notes on the addendum manual This manual is an addendum for the installation of the optional RO leak detection system for the Nortec ME Control and must be read in conjunction with the installation manual and operation manual for Nortec ME Control. This addendum manual has been written to ensure the safe use, performance and longevity of the equipment and is intended for use by engineers and properly trained technical personnel. Please read this manual thoroughly before installing the optional RO leak detection sensor. If you have questions after reading this documentation, please contact your Nortec representative. They will be glad to assist you. Symbols used in this manual CAUTION! The catchword "CAUTION" used in conjunction with the caution symbol in the circle designates notes in this manual that, if neglected, may cause damage and/or malfunction of the unit or other material assets. WARNING! The catchword "WARNING" used in conjunction with the general caution symbol designates safety and danger notes in this manual that, if neglected, may cause injury to persons. DANGER! The catchword "DANGER" used in conjunction with the general caution symbol designates safety and danger notes in this manual that, if neglected, may lead to severe injury or even death of persons. Safekeeping Please safeguard this addendum manual in a safe place, where it can be immediately accessed. If the equipment changes hands, the documentation must be passed on to the new operator. If the documentation gets misplaced, please contact your Nortec representative. Language versions This addendum manual is available in various languages. Please contact your Nortec representative for information. 4 Introduction

2 For your safety General Every person working with the RO leak detection system and the Nortec ME Control must have read and understood this addendum manual, and the Nortec ME Control installation manual and operation manual, before carrying out any work. Knowing and understanding the contents of the manuals is a basic requirement for protecting the personnel against any kind of danger, to prevent faulty operation, and to operate the unit safely and correctly. All ideograms, signs and markings applied to the unit must be observed and kept in readable state. Qualification of personnel All work described in this addendum manual may only be carried out by specialists who are well trained and adequately qualified and are authorized by the customer. For safety and warranty reasons any action beyond the scope of this manual must only be carried out by personnel with appropriate industry recognised qualifications or training. It is assumed that all persons working with the RO leak detection system and the Nortec ME Control are familiar and comply with the appropriate local regulations on work safety and the prevention of accidents. Intended use The RO leak detection system is intended exclusively for the detection of standing water in AHU's or air ducts, or at the location of hydraulic installation of the Nortec ME Control, and within the specified operating conditions. Any other type of application, without the written consent of the manufacturer, is considered as not conforming with the intended purpose and may lead to the Nortec ME Control becoming dangerous. Operation of the equipment in the intended manner requires that all the information contained in this addendum manual as well as in the Nortec ME Control installation manual and operation manual are observed (in particular the safety instructions). Danger that may arise from the Nortec ME Control DANGER! Risk of electric shock! The control unit of the Nortec ME Control contains live mains voltage. Live parts may be exposed when the control unit is open. Touching live parts may cause severe injury or danger to life. Prevention: Before commencing any work on the RO leak detection system and the control unit disconnect the mains supply voltage to the control unit via the electrical isolator in the mains supply line, and secure the electrical isolator in "Off" position against inadvertent switching on. For your safety 5

Safety Reporting All persons working with the RO leak detection system are obliged to report any alterations to the system that may affect safety to the owner without delay and to secure such systems against accidental power-up. Prohibited modifications to the unit No modifications must be undertaken on the RO leak detection system without the express written consent of the manufacturer. For the replacement of defective components use exclusively original accessories and spare parts available from your Nortec representative. 6 For your safety

3 System overview / Principle of operation 3.1 Overview RO leak detection system The leak detector will be installed at the factory, if the RO leak detection is selected when the ME system is ordered. The sensors have to be installed, connected and checked on site. The system is available with 2 or 3 sensors. The sensors are labelled with consecutive numbers on the top side. The zone is therefore visible. Leak detector Sensor 1 Zone 1: Close to ME evaporative module, on the duct floor Sensor 2 & Sensor 3 Zone 2/3: Close to ME hydraulic module, on the floor Fig. 1: Overview RO leak detection system - Showing system with 3 sensors System overview / Principle of operation 7

3.2 Scope of delivery The RO leak detection system consists of the following components: Leak detector Leak detector mounting bracket Connecting cable leak detector Connecting cable sensors RO leak sensor Self tapping screw No.8 x 1.5" Sensor enclosure Insulating disc Fig. 2: Scope of delivery 8 System overview / Principle of operation

3.3 Principle of operation The RO leak detection system is designed to detect standing water inside the AHU where the Nortec ME evaporative module is installed and outside the AHU below the hydraulic modules, and prevent further flooding from occurring. When water enters the sensor enclosure it bridges the two electrodes on the bottom side of the sensor and signals the Nortec ME Control system to enter fault mode, error message (E54) will be shown on the display. Depending on the operating mode selected the system can either be left to continue running, or be disabled with the water inlet valve and drain held closed in order to minimise the potential for further flooding. Fig. 3: Fault indication on display When the fault occurs, a trained engineer must inspect the AHU and installed equipment to ascertain the source of the fault and correct it. If the leakage problem has been solved the alarm can be switched off by switching the Condair ME control unit off and then on again (or by pressing the reset switch on the leak detector). System overview / Principle of operation 9

4 Installation work 4.1 Installing leak detector into control unit (retrofit parts only) Nortec ME Control systems purchased with the RO leak detection system will be provided with the leak detector already fitted in the control unit. DANGER! Risk of electric shock! Electrical work must only be carried out by an appropriately trained engineer. Please ensure a risk assessment has been completed before starting any electrical work. Isolate all power before carrying out any electrical work. 1. Isolate power to the Nortec ME control unit by switching off the electrical isolator. Secure the electrical isolator in the "Off" position to prevent inadvertent switching on. 2. Remove the front cover of the control unit. CAUTION! Electronic components are very sensitive to electrostatic discharge. Before proceeding with the next step, appropriate measures (ESD-protection) must be taken to prevent damage to electronic components. 3. Open the control unit inner door. 4. Remove the lid of the central cable trunking, then remove both screws/washers that secure the cable trunking (see Fig. 4). 5. Place the bracket underneath the cable trunking and rest the bracket tab on the slot as shown in the image below (see Fig. 4). 10 Installation work

6. Fasten the bracket and cable trunking using the screws and washers (see Fig. 4). Central cable trunk Bracket Fig. 4: Bracket Installation 7. Pull off the red operating part from the base of the leak detector supplied. Connect the provided three-core cable to the terminals on the leak detector base as shown in Fig. 5. 21 24 + 22 32 12 34 + A2 31 11 A1 14 green +24V Fig. 5: Leak detector base connections Installation work 11

8. Attach the leak detector base to the longer of the two DIN rails on the bracket. Secure leak detector base on either side using DIN rail end stops, as shown in Fig. 6. DIN rail end stops Leak detector base Fig. 6: Installing leak detector base 12 Installation work

9. Remove the lids of the cable trunkings that surround the driver board and remove from the trunkings. 10. Feed the leak detection cable (grey) upwards through the cable trunking and connect it to terminal "X12" on driver board (refer to Fig. 7 for details on connections). Control unit Nortec ME Control 24V P ERR FQ N FQ1 N FQ2 FQ+ LVL DP CS1 LEAK X11 X12 F2 (630 mat) X13 21 24 + 22 32 12 34 + A2 31 11 A1 14 green +24V green Driver board Fig. 7: Connecting the leak detector base to the driver board Installation work 13

11. Feed the sensor cable through the rectangular cable lead-through into the control unit lead it inside the cable trunkings to the connecting point of the leak detector base (see Fig. 8). 24V P ERR FQ N FQ1 N FQ2 FQ+ LVL DP CS1 LEAK X11 Fig. 8: Sensor cable feed through X12 F2 (630 mat) X13 12. Connect the sensor cable to the corresponding terminals on the leak detector base as shown in Fig. 9. 21 24 + 22 32 12 34 + A2 31 11 A1 14 green +24V Shield to sensor 1 Fig. 9: Connecting the sensor cable to the leak detector 14 Installation work

13. Put the lids back on to the cable trunking. 14. Align contact pins of the red operating part of the leak detector to the corresponding connector holes in leak detector base. Then, push the red operating part into leak detector base until it comes to a stop. 15. The installation of the leak detector in the Nortec ME control unit is now finished. Close inner door, reattach and secure the front panel. 16. Proceed with chapter 4.2 to connect the cable to the sensors. Installation work 15

4.2 Connecting the sensors 4.2.1 Preparing the sensor cables 1. Evaluate cable length between Nortec ME control unit and sensor 1 and between sensor 1 and sensor 2 and if applicable between sensor 2 and sensor 3 and cut sensor cables to length. 2. Remove cable sheath from the last 0.8" (20 mm) of the sensor cables (see Fig. 10). Do not remove the cable shielding. 3. Pull the cable shielding back over the cable sheath (see Fig. 10). 4. Strip the last 0.2" (5 mm) of the insulation from the sensor wires (see Fig. 10). 0.8" 0.2" Fig. 10: Preparing the sensor cables 4.2.2 Connecting the sensor cables to the sensors 1. Remove the clamp(s) on the underside of the sensors. 2. Place sensor cable in the groove. Ensure the shielding of the sensor cable is touching the pin in the groove. 3. Reattach clamp and fasten the screws. 4. Connect and wires of the sensor cables to the appropriate terminals of the sensors according to chapter 4.2.2.1 (systems with 2 sensor) or chapter 4.2.2.2 (systems with 3 sensor). Cable clamp Pin Shielding must touch pin Fig. 11: Connecting the sensor cables to the sensors 16 Installation work

4.2.2.1 Wiring layout for systems with 2 sensors Sensor 1 To sensor 2 "von Folgesensor" Typ SKL 401 Art. A91144010 1 Cut both wire bridges "Signalausgang" Fig. 12: Sensor 1 top view From leak detector Fig. 13: Sensor 1 bottom view Connect cable from leak detector to the terminals on the side labeled "Signalausgang". Connect cable to sensor 2 to the terminals on the side labeled "von Folgesensor". Cut both wire bridges of sensor 1. Sensor 2 (end sesor) Typ SKL 401 Art. A91144010 2 Cut only one of the two wire bridges "Signalausgang" Fig. 14: Sensor 2 top view From sensor 1 Fig. 15: Sensor 2 bottom view Connect cable from sensor 1 to the terminals on the side labeled "Signalausgang". Cut one of the two wire bridges of sensor 2. Be aware of the correct connection of the shield and cable colours /! Do not run the sensor cables parallel to power cables! Installation work 17

4.2.2.2 Wiring layout for systems with 3 sensors Sensor 1 To sensor 2 "von Folgesensor" Typ SKL 401 Art. A91144010 1 Cut both wire bridges "Signalausgang" Fig. 16: Sensor 1 top view From leak detector Fig. 17: Sensor 1 bottom view Connect cable from leak detector to the terminals on the side labeled "Signalausgang". Connect cable to sensor 2 to the terminals on the side labeled "von Folgesensor". Cut both wire bridges of sensor 1. Sensor 2 To sensor 3 "von Folgesensor" 2 Typ SKL 401 Art. A91144010 Cut both wire bridges "Signalausgang" From sensor 1 Fig. 18: Sensor 2 top view Fig. 19: Sensor 2 bottom view Connect cable from sensor 1 to the terminals on the side labeled "Signalausgang". Connect cable to sensor 3 to the terminals on the side labeled "von Folgesensor". Cut both wire bridges of sensor 2. 18 Installation work

Sensor 3 (end sensor) Typ SKL 401 Art. A91144010 3 Cut only one of the two wire bridges "Signalausgang" From sensor 2 Fig. 20: Sensor 3 top view Fig. 21: Sensor 3 bottom view Connect cable from sensor 2 to the terminal on the side labeled "Signalausgang". Cut one of the two wire bridges of sensor 3. Be aware of the correct connection of the shield and cable colours /! Do not run the sensor cables parallel to power cables! Installation work 19

4.2.3 Fixing the sensors to the AHU floor or building floor Important: Do not fix the sensors to the AHU/building floor unless the tests in chapter 6.1 have been successfully finished. 1. Fix the sensor enclosure to the AHU/building floor: Recommended fixing for AHU's Recommended fixing for building floor Self tapping screw Self tapping screw Sensor enclosure Sensor enclosure Insulating disc (must be used on metallic surfaces) Insulating disc (must be used on metallic surfaces) Dowel Drill a ø.12" (ø3.2) mm pilot hole into the floor of the AHU at the central point of location. Insert a No.8 x 1.5" self-tapping screw through the centre of the sensor enclosure and screw the enclosure together with the insulating disc (required for metallic surfaces) tight to the floor of the AHU. Drill at the desired position a hole for a dowel with the appropriate diameter and depth into the floor. Insert the appropriate dowel into hole, then insert a No.8 x 1.5" self-tapping screw through the centre of the sensor enclosure and screw the enclosure with the insulating disc (required for metallic surfaces) tight to the building floor. 2. Secure the sensor cables with cable ties at suitable intervals along the cable run between the Nortec ME control unit and the sensors. Note: Ensure sensor cable is placed in such a way that the insulation is not damaged by sharp edges and so that it does not create a trip hazard or hinder correct maintenance of the components. 20 Installation work

5 Configuration 5.1 Configuration process Nortec ME Control systems purchased with the RO leak detection system will be provided with the leak detection function already activated. If the RO leak detection system is retrofitted into an existing Nortec ME Control system, the function must be activated in the Engineering level of the control software as follows. Note: This process is only to be carried out by a Nortec engineer or distributor. Press <Menu> button Enter Engineering menu password and confirm Select <Engineering> Select <More...> Select <Safety Parameter> Select <Standing Water> Switch function from "Off" to "Active" or "Passive" and confirm. Fig. 22: Configuration process Description of the "Active" and "Passive" mode Passive: If standing water is detected, the system activates a fault but continues to operate as normal. Active: If standing water is detected, the system stops operating and shuts the inlet and drain valve. After 24 hours the system will automatically drain the water tank. Configuration 21

6 Operation 6.1 Functional tests Leak detection test Test all sensors which will be used in the RO leakage detection system for correct functioning as follows: 1. Place the sensor in liquid, so that a conductivity connection between the two electrodes on the bottom side of the sensor is triggered (see arrow in figure below). Electrodes Fig. 23: Electrodes to be place in liquid When the sensor is placed in the liquid check the following: Is alert audible (only if "Summer" is set to "1" on the leak detector)? Does the error message appear on the display? Did the water inlet valve close? Note: If the ME control leak monitoring is configured to "Passive", the inlet valve will neither open nor close. 2. Remove sensor from the liquid and dry it. Reset the Error by switching off and on the Nortec ME control unit. Important: the error must not reset automatically if sensor is removed from the liquid. 3. Repeat step 1 to 2 with the remaining sensors. Cable break test 1. Disconnect the end sensor (sensor 2 or 3) in order to examine the cable break detection. If end sensor is disconnected check the following: Is alert audible (only if "Summer" is set to "1" on the leak detector? Does the error message appear on the display? Did the water inlet valve close? 2. Reconnect end sensor. After both tests have been carried out successfully fix sensors to the AHU/building floor, respectively as described in chapter 4.2.3. Important: It is recommended to repeat both tests periodically. 22 Operation

6.2 Display and operating elements of the leak detector Fig. 24: Leak detector LED "Alarm" Button "Test" Button "Reset" F1 F2 Summer Empfindl. LED "P" LED "Störung" Factory Settings F1 = 0 F2 = 0 Summer = 1 Empfindl. = H Notifies detection of a liquid Simulation of a leakage Alarm acknowledgement 1 = Auto Reset (automatic alarm acknowledgement after fixed leakage) NOT RECOM- MENDED! 0 = Alarm memory (manual alarm acknowledgement by "Reset"-key or through external reset needed) no function 1 = internal buzzer activated during leakage alarm 0 = buzzer deactivated H = high sensitivity T = low sensitivity Operation indicator mains voltage Fault indicator in case of sensor cable break or defective units Operation 23

7 Spare parts Leak detector Leak detector mounting bracket Connecting cable leak detector Connecting cable sensors RO leak sensor Self tapping screw No.8 x 1.5" Sensor enclosure Insulating disc Fig. 25: Spare parts Please contact your Nortec representative for spare parts! Safe disposal of electrical and electronic components Please dispose of defective parts in accordance with your local recycling laws and regulations. Waste electrical and electronic equipment may contain hazardous substances, which, if nottreated properly, can be harmful to the environment and human health. Specific treatment of waste electrical and electronic equipment is therefore essential. 24 Spare parts

8 Appendix 8.1 Wiring diagram for RO leak detection systems with 2 sensors Control unit Nortec ME Control 24V P ERR FQ N FQ1 N FQ2 FQ+ LVL DP CS1 LEAK 21 24 + 22 32 12 X11 X12 F2 (630 mat) X13 34 + A2 31 11 A1 14 green +24V green Driver board Leak detector Sensor 1 Sensor 2 "Signalausgang" "von Folgesensor" "Signalausgang" cut both wire bridges cut one of the two wire bridges Appendix 25

8.2 Wiring diagram for RO leak detection systems with 3 sensors Control unit Nortec ME Control 24V P ERR FQ N FQ1 N FQ2 FQ+ LVL DP CS1 LEAK 21 24 + 22 32 12 X11 X12 F2 (630 mat) X13 34 + A2 31 11 A1 14 green +24V green Driver board Leak detector "Signalausgang" Sensor 1 Sensor 2 Sensor 3 "von Folgesensor" "Signalausgang" "von Folgesensor" "Signalausgang" cut both wire bridges cut both wire bridges cut one of the two wire bridges 26 Appendix

Warranty Nortec Humidity Inc. and/or Nortec Humidity Ltd. (hereinafter collectively referred to as THE COMPANY), warrant for a period of two years after installation or 30 months from manufacturer s ship date, whichever date is earlier, that THE COMPANY s manufactured and assembled products, not otherwise expressly warranted, are free from defects in material and workmanship. No warranty is made against corrosion, deterioration, or suitability of substituted materials used as a result of compliance with government regulations. THE COMPANY s obligations and liabilities under this warranty are limited to furnishing replacement parts to the customer, F.O.B. THE COMPANY s factory, providing the defective part(s) is returned freight prepaid by the customer. Parts used for repairs are warranted for the balance of the term of the warranty on the original humidifier or 90 days, whichever is longer. The warranties set forth herein are in lieu of all other warranties expressed or implied by law. No liability whatsoever shall be attached to THE COMPANY until said products have been paid for in full and then said liability shall be limited to the original purchase price for the product. Any further warranty must be in writing, signed by an officer of THE COMPANY. THE COMPANY s limited warranty on accessories, not of the companies manufacture, such as controls, humidistats, pumps, etc. is limited to the warranty of the original equipment manufacturer from date of original shipment of humidifier. THE COMPANY makes no warranty and assumes no liability unless the equipment is installed in strict accordance with a copy of the catalog and installation manual in effect at the date of purchase and by a contractor approved by THE COMPANY to install such equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for consequential damage or damage resulting directly from misapplication, incorrect sizing or lack of proper maintenance of the equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for damage resulting from freezing of the humidifier, supply lines, drain lines, or steam distribution systems. THE COMPANY retains the right to change the design, specification and performance criteria of its products without notice or obligation.

CONSULTING, SALES AND SERVICE: U.S.A. 826 Proctor Avenue Ogdensburg, NY 13669 CANADA 2740 Fenton Road Ottawa, Ontario K1T 3T7 TEL: 1.866.NORTEC1 FAX: 613.822.7964 EMAIL: nortec@humidity.com WEBSITE: www.humidity.com