Industrial Heat Tracing Products and Services

Similar documents
INDUSTRIAL HEAT TRACING SOLUTIONS PRODUCTS & SERVICES

ADVANCED INDUSTRIAL SOLUTIONS HEAT-TRACING PRODUCTS & SERVICES

Before You Buy, Weigh the Facts

INDUSTRIAL HEAT TRACING SOLUTIONS. Products & Services

Longline Heating. Introduction

C910 Series. Single-point heat-tracing control system

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

Power-Limiting Cables

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

Longline Heating. Contents. Introduction

Fuel Leak Detection Find Leaks Before They Find You

Tyco Thermal Controls. Heat Management Solutions for Upstream Sector. Valentin ILIE Tyco Thermal Controls

ACCS-30. Multipoint commercial heat-tracing control system

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

C A Heating Cable Gland Kit

RayClic Connection System

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

Heat-Trace Panels. Introduction

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Tyco Thermal Controls. Oil Field Services. Providing Thermal Technologies to meet your Upstream Flow Assurance Needs Tyco Thermal Controls

Industrial Strength Leak Detection

Skin-Effect Heat-Tracing System (STS)

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

XL-Trace System Application and Design Guide

Mineral Insulated Heating Cables

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

CommerciaL fire-rated

Gardian W51. Approvals

Commercial and Residential Self-Regulating Heating Products

Freezer Frost Heave Prevention

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

THERMAL MANAGEMENT SOLUTIONS

Selection guide for self-regulating heat-tracing systems

Supervisor Standard Edition

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

THERMAL MANAGEMENT SOLUTIONS

910 Series Single-point heat-tracing control system

Technical Databook for Industrial Heating Systems

QuickStat-TC Installation & Operation Manual

NGC-20 LOCAL CONTROL CENTRAL MONITORING

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

Raychem Heating System

Tank Heating. Introduction. Self-Regulating Heating Cables

Dual-point heat-tracing control system

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

C Electrical Connection Kit

DigiTrace NGC-family

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

INDUSTRIAL fire-rated wiring

Industrial Heat Tracing Solutions EN-HeatTracingGlossary-AR-H /16 1 / 8

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

frost heave prevention

TraceTek TT1000 Modular Sensing Cable

NGC-40 Advanced Heat-Tracing Control System

1SC-SSC Splice Connection Kit Installation Instructions

RAYCHEM NGC-30 COMPONENTS

fuel leak detection find leaks before they find you

Roof and Gutter De-Icing

Union County Vocational - Technical Schools Scotch Plains, New Jersey

WILDLIFE AND ASSET PROTECTION PRODUCTS

INDUSTRIAL HEAT TRACE

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

PolySwitch TS600 Overcurrent Protection Devices

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

AmpLight Lighting Management System

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

Polymer solutions Heating mat EM2-CM

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

IQ4 METAL DETECTION SYSTEMS

TraceTek FIND LEAKS BEFORE THEY FIND YOU

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Tether and Umbilical Cables for Remotely Operated Vehicles

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

FTC-HST WARNING: CAUTION:

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

CABLE SERVICES. Data Input Sheet - Fax Back

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

ACS-30-EU-EMDR- 10-MOD

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Drexan Energy Systems Inc.

CO 2 Laser. High Reliability and Performance

COMMERCIAL HEAT TRACING. Products and Services

FreezGard. Self-regulating crankcase heater. Product Overview

Transcription:

Industrial Heat Tracing Products and Services

Before You Buy, Weigh the Facts Tyco Thermal Controls is The Leading Full-Service Integrator Complete Construction, Project Management and Maintenance Provider Global Heat-Tracing System Engineering and Design Capability Greater Product Selection and Quality Innovative Products and Services The Most Advanced Line of Control and Monitoring Systems Billi n

We manage the heat you need For Proven Heat-Tracing Solutions, Look to the Leader For Every Heat-Tracing Need, Depend on the Undisputed Industry Leader Tyco Thermal Controls stands as the world leader in heat-tracing solutions for industrial markets. An innovation company, Tyco Thermal Controls offers world class products and turnkey services under such industry renowned names as Raychem, Tracer, Pyrotenax, DigiTrace, and TRACERLYNX. Our Tracer Services Division is widely regarded as the premiere provider of turnkey heat-tracing solutions in the industrial market today. Offering turnkey engineering, design, construction and maintenance, Tyco Thermal Controls is capable of handling heat-tracing projects of any size and scope. By focusing on safety and utilizing our time-tested methods and solutions, Tyco Thermal Controls heat-tracing designs and installations are timely, thorough, and cost-effective. Tyco Thermal Controls has sold over one billion feet of Raychem brand self-regulating heating cable. As the inventor of self-regulating heat tracing, our Raychem brand is known for technical leadership and expertise in polymer science and radiation cross-linking both critical parts of the process. Tyco Thermal Controls DigiTrace brand offers the most advanced line of heat-trace control and monitoring systems-from single circuit mechanical thermostats to multi-circuit, microprocessor-based networked systems. Easy to use interface technologies put information and programming at your fingertips. Our Pyrotenax brand Mineral Insulated heating cable has been an industry leader for over 75 years. 1

E L E C T R I C H E AT-T R A C I N G S Y S T E M S Heat-Trace Panel (may include circuit breakers, controllers and alarms) A complete electrical heat-tracing system is much more than just the heating cable. Tyco Thermal Controls provides a complete system from electrical transformer and heattrace panel to power connections, heating cable, end terminations, and other accessories. We supply the individual components, provide engineering and design and install and maintain the entire system. Note: The illustrations on these pages do not necessarily depict actual applications and installations. Transformer Lighted End Seal Remote configuration and monitoring with DigiTrace Supervisor software Insulation Systems RTD Temperature Measurement separate wiring run to panel (shown) Power Connection Heating Cable Electric Heat-Traced Pipe A typical cross section of an electrically heat-traced pipe. Fluid Cladding Insulation 2 Heating Cable

STEAM-TRACING SYSTEMS A steam-tracing system may be chosen for a particular site or process consideration. A complete system can consist of a steam supply source, steam tubing, valves, traps, and return lines. Tyco Thermal Controls can supply a complete steam-tracing system from engineering, design, material supply and installation. Steam Supply Steam Supply Manifold Condensate Return Manifold Condensate Return Steam-Tracing Steam-Traced Pipe A typical cross section of a steam-traced pipe. Fluid Insulation Copper or Stainless Steel Tubing Cladding 3

SERVICES A Heat Management System (HMS) is an engineered system designed to maintain or protect process piping, equipment, vessels and instruments at pre determined temperatures and within defined design criteria. Front End Planning Engaging Tyco Thermal Controls early in the planning process allows us to help you make decisions which can reduce overall installed cost of the heat management system. Detailed Engineering Our experienced engineers apply product and optimization strategies to design a heat management system which meets your specific requirements at the lowest possible cost. Committed to safety through proactive safety management techniques. 4 Safety Safety is our number one concern. We are recognized as a leader in the industry in safety performance by consistently challenging the norm through safety innovations including training and motivational programs. WARM PIPE W A R R A N T Y Warm Pipe Warranty By allowing Tyco Thermal Controls to handle all of the engineering, design, and construction of your heat-tracing system, we can provide you with a Warm Pipe Warranty, ensuring that the system operates as specified. Post Installation Services and Maintenance Providing regular Heat Management System audits or implementing a maintenance agreement, Tyco Thermal Controls provides you with the security of having your system regularly evaluated by experts in the heattracing industry, allowing timely resolution of potential system problems.

Procurement Tyco Thermal Controls will manage all materials procurement and fabrication activities making sure the right materials get to the right work location at the right time. Installation and Construction Our construction teams are fully trained and experienced in heat-tracing installation techniques. Leverage our expertise to ensure timely and correct installation of your heat management system components, insulation and cladding. Site Services Using our Site Services allows you to maintain a single point of responsibility and accountability through the entire installation process. This ensures continuity of project knowledge from engineering through start-up. We can manage all the necessary services you need: Engineering, Procurement, Construction and Construction Management, Quality Assurance. Quality Assurance/ Quality Control Our Quality Management System addresses all processes including the design, supply, installation, and commissioning to ensure your Heat Management System is operating as intended. Commissioning Our commissioning services ensure that the heat management system is operating as expected. This includes full system audits, programming and set up of control panels and operational checks. 5

heat management system INNOVATION Tyco Thermal Controls has a history of continuous innovation Magnesium oxide insulation Solid conductors How self-regulation works in the Raychem conductive-polymer heaters: Copper bus wire BTV and QTVR heating cables share a similar construction as illustrated at right. Selfregulating conductivecore heating element Insulating jacket Braided tin-copper shield and outer jacket Seamless metal sheath Pyrotenax MI heating cable has been an industry standard for over 75 years Cold Pipe: In response to cold, the core or fiber contracts microscopically opening up electrical paths. Warm Pipe: In response to warmth, the core or fiber begins to expand microscopically disrupting the electrical paths. Hot Pipe: The core or fiber expands enough to disrupt almost all of the electrical paths. XTV heating cables feature a fiber-wrap construction that can easily be cut back for power connection and termination. Copper bus wire Selfregulating conductive fiber Insulating jacket Braided tin-copper shield and outer jacket Raychem self-regulating cables revolutionized the industry Heat-Tracing Cable Systems Ground Fault and Line Current Monitoring and Alarm made systems safer and reduced cost Power Line Carrier technology eliminated RTD wiring resulting in lower field installation costs Control and Monitoring Systems Safe, reliable and experienced Installers offer an industry leading Warm Pipe Warranty TraceCalc Pro provides heat-tracing design calculations for heat management systems Heat Management System Design, Engineering and 6

in all aspects of heat management systems Variable Power Limiting (VPL) technology allows high temperature cable to be wrapped over itself simplifying installation PyroFLX MI heating cables incorporate tray cable for easy installation Fiberglass yarn PTC alloy Fluoropolymer outer jacket Power-limiting heating element Metal braid Fluoropolymer inner jacket Bus wire connection Clear jacket Nickel-plated bus wires DigiTrace NGC Control and Monitoring Systems have easy to use touch screens that make it simple and easy to use your HMS PC based software allows monitoring, status check and configuration of your HMS from any location Finite Element Analysis evaluates solutions for highly specialized and complex applications 3D HMS Software designed specifically to integrate heat management system design capability with 3D plant modeling systems Installation 7

HEAT-TRACING PRODUCTS Tyco Thermal Controls offers the industry s most complete line of heat-tracing products to meet every need for everything from pipe freeze protection to high temperature process maintenance. Our industrial heating cables are backed by a ten-year extended warranty! Self-Regulating Cables Raychem BTV cable provides freeze protection on metal and plastic pipes, maintaining temperatures up to 150 F (65 C) and withstanding exposure to 185 F (85 C). Raychem QTVR cable provides freeze protection and process temperature maintenance, maintaining and withstanding exposure temperatures up to 225 F (110 C). Raychem XTV fiberwrap cable provides process temperature maintenance up to 250 F (121 C) and withstands intermittent exposures to 420 F (215 C). Mineral Insulated Cables Power-Limiting Cables STS Cables 8 For high temperature applications: Pyrotenax MI cable maintains temperatures up to 1022 F (550 C) and withstands continuous exposure to 1200 F (650 C). For applications exceeding the temperature range of self-regulating cables: Raychem VPL heating cable maintains temperatures greater than 300 F (150 C) and withstands continuous exposure to 500 F (260 C), power off. Note: These photos and illustrations do not necessarily depict actual applications and installations. For longline and high temperature applications: Tracer STS cable maintains temperatures up to 392 F (200 C) and withstands continuous exposure to 482 F (250 C) while providing power outputs up to 45 W/ft (150 W/m).

Longline Heating Choose from the most complete selection of longline heat-tracing systems and technologies. Circuit lengths can vary from 500 feet (152.4 meters) to over 15 miles (24 kilometers): Raychem Self-regulating systems, LBTV, SLBTV and VLKTV cables Raychem Series resistance systems, SC cables Pyrotenax MI mineral insulated cables Tracer STS skin-effect system Fiber optic temperature measurement technologies Tank Heating Choose from tank pad heaters and heating cables for tank and vessel heating solutions. The Raychem RHS tank heating system maintains tank temperatures up to 200 F (93 C). Heaters are available from 150 watts to 1,400 watts. RHS-L heaters can be used on polypropylene, FRP, and metal tanks Tubing Bundles Raychem tubing bundles (RTB) offer a cost-effective alternative to traditional field tracing and insulating. Pre-traced and pre-insulated tubing bundles for such applications as impulse, sample, and process lines Choice of single or dual tubing in stainless steel, monel, copper, PFA Teflon, or other materials Choice of electric or steam-traced bundles Snow and Ice Prevention Raychem self-regulating heating cables are installed in concrete to prevent dangerous icing on loading ramps, walkways, entrances, and driveways Raychem heating cables are installed on roofs and gutters to prevent hazards and property damage caused by ice buildup Pyrotenax mineral insulated cables are installed in concrete and asphalt and provide a constant heat output Safer and More Reliable Connection Kits and Accessories Raychem connection kits and accessories are vital parts of any heat-tracing system. These high quality products are faster, safer and easier to install and deliver reliable service. All install without a torch, heat gun or hazardous sealants. The accessories such as stripping tools are designed to enhance the safety, speed and reliability of installations. Spring clamp terminals provide reliable connection and allow easy reentry The kits typically install in a few minutes with standard tools. The cable stripping tool, specifically designed to work with Raychem self-regulating heaters, further reduces the installation time and enhances the safety of the installers High-intensity LED lights are available with our power connections and end seals to provide visual monitoring of system power and continuity 9

CONTROL AND MONITORING SYSTEMS Single and Multipoint Control and Monitoring Systems DigiTrace control and monitoring systems provide scalable solutions for both hazardous and nonhazardous locations. They also feature continuous programming and monitoring technology to change system settings, detect heat-tracing faults and provide alarm indication. DigiTrace NGC-30 DigiTrace NGC-40 NGC-30 Electronic Multi-Circuit Heat-Tracing Control, Monitoring and Power Distribution System: Easy-to-use touch screen interface provides fast and intuitive access to heattracing status, alarms and programming RMM2 and PLI compatible to help reduce overall installed costs Multiple control modes allow reduced operating costs based on application needs Three independently programmable alarm relay outputs provide Smart Status based on specific alarm conditions. NGC-40 Advanced Single-Point Control in a Multipoint Heat-Tracing System: Single controller per heat tracing circuit architecture provides the highest possible system reliability available in the market today Easy-to-use TOUCH 1500 touch screen provides fast and intuitive access to heat-tracing status, alarms and programming Modular architecture allows maximum flexibility in panel design and features set. I/O Modules allow additional RTD inputs and provide programmable digital outputs and inputs to drive or react to external units. Remote Mount UIT2 TOUCH 1500 10 All DigiTrace NGC controllers come with the following features: 60 Amp current ratings support longer circuit lengths allowing overall system cost reductions Wide range of alarms with programmable thresholds notify you when problems occur Various levels of secure, password protected access provided for different user groups Network ready with Ethernet, RS-485 and RS-232 interfaces built in Available for hazardous Class I, Division 2 and nonhazardous locations Compatible with DigiTrace Supervisor remote access and control software

DigiTrace 910 and 920 These compact, full-featured, microprocessor based heat-tracing control systems are designed for use when just a few lines of heat tracing are required. Both controllers are available for hazardous and nonhazardous locations and are fully compatible with the DigiTrace Supervisor software. 910 Series Single-Point, Self Contained Controller 920 Series Dual-Point Self Contained Controller Supervisor Software The DigiTrace Supervisor software enables users to interface with field installed DigiTrace NGC-30, NGC-40, 910 and 920 control Systems. The Windows -based Supervisor software can be used to program individual units or groups of units, monitor, check, and record alarm status, data log, and generate reports. 11

CONTROL AND MONITORING accessories Additional Heat-Tracing Control Panels and Accessories SES RMM2 E507S-LS JBS-100-ECP-A PLI Power Line Carrier Interface Technology The DigiTrace Power Line carrier Interface (PLI) technology can provide up to a 20% reduction in control and monitoring system installation costs. Consisting of the PLI module, Smart End Seal and Smart Power Connector components, the PLI solution is available on NGC-30 systems. Installation cost savings are realized by eliminating the need for RTD wiring and conduit from the installation. Remote Temperature Monitoring DigiTrace NGC-30 Control and Monitoring Systems are supported by remote temperature monitoring devices (RMM2). These devices are designed to help reduce costs by aggregating the RTD inputs and reducing the number of home runs for RTDs. The devices are available for hazardous and nonhazardous locations. DigiTrace JBS-100-ECP-A and JBS-100-ECW-A These electronic temperature controllers provide accurate control of a single heating circuit using a RTD sensor in non-hazardous locations. The JBS- 100-ECP-A is pipe-mounted and serves as a power connection kit for both Raychem self-regulating and Pyrotenax mineral insulated heating cables. The JBS-100-ECW-A is wall-mounted, and may be used with all types of heating cables. Thermostats and RTDs DigiTrace simple ambient and line sensing mechanical or electronic thermostats are for use in nonhazardous and hazardous locations. RTD s can be selected based on the area of application, nonhazardous or hazardous, and the required operating temperature ranges. 12 HTPG HTPI Power Distribution Heat Trace Panels DigiTrace dedicated power-distribution panels can reduce costly field wiring and reduce controller costs. Choose from a complete line of dedicated heattracing power distribution panels. Each is available with: Group or individual circuit control Standard circuit breakers, ground-fault breakers, or ground-fault breakers with alarm

ENGINEERED PRODUCTS Tyco Thermal Controls offers a wide array of engineered products for the industrial market. Each product is designed to add value to even the simplest of heat-tracing installations. Steam-Tracing Systems Providing complete steam-tracing and recirculating fluid-tracing systems, Tyco Thermal Controls Services include not only installation, but also isometric detail drawings with heat-tracing parameters and calculations, typical and project specific installation details, nameplate and tagging schedules, complete system Bill of Material generation, and post-construction as-built documentation. These, along with established project management techniques, ensure your steam-heating system performs as required. Pipe Shoes The Interlock clamp-on pipe shoe is a patented pipe support design that eliminates field welding requirements for pipe supports, which is a significant benefit in heattracing design and construction. It can be used on all pipe applications, including bare pipe, painted pipe, insulated pipe, and heat-traced pipe. Pre-Traced Pre-Insulated Safety Stations ShowerGuard pre-traced, pre-insulated safety shower/eyewash unit is designed to minimize field installation requirements and eliminate the numerous disadvantages associated with field installations of electric heat-trace cable, insulation, and moisture-barrier jacketing. 13

TANk INSULATION SYSTEMS Trac-Loc Tank Insulation System The Trac-Loc system is an advanced vertical double-locking standing seam insulation panel system that s unique in its design, panel construction and installation techniques. Trac-Loc is ideal for large, flat-bottom tanks used for storage of materials that are sensitive to temperature fluctuations and require a covering of insulation and jacketing to reduce heat loss or gain. The unique panel design eliminates the need for expensive scaffolding and can be installed faster than traditional tank insulation systems. 14

WEB SERVICES AND SOFTWARE Visit www.tycothermal.com All the tools and information you need to design, select, and purchase a complete heat-tracing system. Use our Web-based program, or download design software to use off-line. Download, print, or browse product data sheets and installation instructions. On-Line Technical Support On our interactive frequently asked questions and answers (FAQ) page, you ll find questions broken down by markets and product lines. If your question does not appear, simply submit a new question. A Tyco Thermal Controls technical expert will answer your question and post it to the Web site. Download Design Software Save time with TraceCalc Pro. This software provides complete heat-tracing designs for pipes, tanks and vessels in a fraction of the time needed for manual design. Design On-Line TraceCalc Net is an on-line tool that walks you through heat trace design in three simple steps: Finding the right products for your application Choosing quantities for a complete bill of materials Selecting optional control and monitoring systems 15

A Solutions Company Tyco Thermal Controls is the world leader in heat-tracing products, engineering, design and construction for industrial markets. Employing over 2,500 people globally, Tyco Thermal Controls has the experience, capabilities and product breadth to meet your heat management system requirements. Worldwide Approach With operations in 48 countries, design centers in Canada, India, China and the US, Tyco Thermal Controls supports your project efforts anywhere, anytime. Our global footprint and total solution approach allows us to provide local support and meet your needs on time whether it s for top-notch products or turnkey services. A global heat management solutions provider, Tyco Thermal Controls is there beside you no matter where you are. The Market Demands We Supply Tyco Thermal Controls provides heat management solutions to a wide range of segments within the industrial market. Biotechnology Biodiesel/Ethanol Chemical Processing Fabricators Food and Beverage Manufacturing Mining Offshore Production Oilfield Services Petrochemical Pharmaceutical Pipelines Power Production Pulp & Paper Refining Semiconductor Fabrication Terminals Waste Management Heat Tracing Services Control and Monitoring 16

North and South American Operations Fort McMurray, Alberta Edmonton, Alberta Everett, WA Menlo Park, CA Redwood City, CA Trenton, Ontario Kitchener, Ontario Chicago, IL Philadelphia, PA Houston, TX Worldwide Headquarters Baton Rouge, LA Headquarters Service/Sales Centers Manufacturing Centers Colonia Juarez, Mexico Sales and Technical Support Visit our website at www.tycothermal.com or contact us at 800-545-6258. Rio de Janeiro, Brazil Sao Paulo, Brazil Santiago, Chile Fire-Rated Wiring Products 3D Plant Modeling 17

Worldwide Headquarters Tyco Thermal Controls 7433 Harwin Drive Houston, TX 77036 USA Tel: 800-545-6258 Tel: 650-216-1526 Fax: 800-527-5703 Fax: 650-474-7711 info@tycothermal.com www.tycothermal.com Tracer Industries Service Headquarters 7433 Harwin Drive Houston, TX 77036 USA Tel: 800-545-6258 Fax: 800-527-5703 U.S.A. Tyco Thermal Controls 307 Constitution Drive Menlo Park, CA 94025-1164 USA Tel: 800-545-6258 Fax: 800-527-5703 Canada Tyco Thermal Controls 250 West St. Trenton, Ontario K8V 5S2 Canada Tel: 800-545-6258 Fax: 800-527-5703 Latin America Tyco Thermal Controls 7433 Harwin Drive Houston, TX 77036 USA Tel: 713-868-4800 Tel: 713-735-8645 Fax: 713-868-2333 Europe, Middle East, Africa Tyco Thermal Controls Romeinse Straat 14 3001 Leuven België / Belgique Tel: +32 16 213 511 Fax: +32 16 213 603 Asia Pacific Tyco Thermal Controls 20F, Innovation Building, 1009 Yi Shan Rd, Shanghai 200233, P.R.China Tel: +86 21 2412 1688 Fax: +86 21 5426 2937 / 5426 3167 Tyco, 910, 920, Automatrix, AMC-1A, AMC-1B, AMC-1H, AMC-2B-2, AMC-F5, BTV, CM2000+, DigiTrace, E-100, E-100-L, E-150, ElectroMelt, E104, E304, E307, E507-LS, E507-2LS-2, HAK-C-100, HBTV, HQTV, HTPG, HTPI, HXTV, IceStop, Isopad, JBM-100, JBS-100, KTV, LBTV, MoniTrace, NGC, PLI, Pyrotenax, PyroFLX, QTVR, RAYSTAT-EX-03-A, RHS, RHS-L, RMM2, RTB, RTD 10/20, RTD-200, RTD-300-10, RTD3CS, RTD4AL, RTD7AL, RTD10CS, S-150, SC, SES, ShowerGuard, SLBTV, T-100, T2, Touch 1500, Trac-Loc, TraceCalc, TraceCalc Pro logo, Tracer, TracerLynx, TraceTek, UIT, VLBTV, VLKTV, VPL, We manage the heat you need and XTV, are registered and/or unregistered trademarks of Tyco Thermal Controls or its affiliates. All other trademarks are the property of their respective owners. 2011 Tyco Thermal Controls LLC H56857 02/11 Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification.