Large-scale fire sprinkler tests with the AutoStore compact storage system

Similar documents
International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

Today's Topics & Sustainability Themes

Early Suppression Fast Response Sprinklers and Obstructions

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

The Loss prevention Council. Phase 1 report

Evaluation of Protection for Plastic Containers Using Sprinkler Systems with 1.0% AFFF and Plain Water

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler Heads Revised

High Ceiling Protection

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

Spray sprinkler system

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

FIRE PROTECTION FOR NON-STORAGE OCCUPANCIES WITH HIGH CEILING CLEARANCES

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

WATER MIST CONVENTION AND EXHIBITION

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

VALOR VISITOR SEATING. Australian made Valor, AFRDI 6 & GECA approved visitor seating. Lic: C H S GECA Furniture and Fittings

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

Sprinklers in Combustible Concealed Spaces

REVEER VISITOR SEATING. Australian made Reveer, AFRDI 5 & GECA approved visitor seating. Lic: C H S GECA Furniture and Fittings

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

Contact person Date Reference Page Alen Rakovic P (19) Fire Research

Installation and Maintenance Requirements

An Overview of Extinguishing Systems for Computer Equipment

The Science Behind Water Mist Protection of Typical Building Hazards

High challenge warehouse case study Summary

Sprinkler Solutions for Storage Applications


Developing Sprinkler System Design Criteria for Flammable and Combustible Liquid Storage

The Effect of Large Orifice Sprinklers on High-Challenge Fires

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

First Revision No. 6-NFPA [ Section No. 2.2 ]

Full Scale Battery Tests

David P. Nugent Schirmer Engineering Corporation 707 Lake Cook Road Deerfield, Illinois SUMMARY

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Flammable Liquid Storage

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Protection of Combustible Liquids Stored In Composite Intermediate Bulk Containers (IBCs) Research Project. Phase II Final Report.

Chapter 3 FF II Fire Department Communications

Leader s Guide 2007 CLMI Training

Exterior Fire Protection for High-Rise Buildings

Box-in-Box Cold Storage Fire Protection Options

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

Lecture 4 Power System Protection. Course map

Tire Storage. Michigan Fire Inspectors Society Fall Conference

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

Redlands Fire Department Fire Protection Standard

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

FIRESAFE II. Alternative fixed-fire extinguishing systems for ro-ro spaces on ships Final Report

Incident Summary (II )

SPRINKLER TECHNOLOGY:

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

Standard for tests for flammability of plastic materials for parts in devices and appliances

Fire Prevention Plan

Extended Coverage Sidewall Sprinklers

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

"USING FIRE EXTINGUISHERS"

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Fire Prevention Plan

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

Ultra low temperature freezers. -40 C and -86 C. Green Line

Case Study of Underground Car Park. Team Japan

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Obstructions and ESFR Sprinklers Phase 1

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

The Situation. Modeling Storage Occupancies Under Sloped Ceilings. Concerns (Elevation View) The Concerns 4/29/ NFPA Conference & Expo

Product Data Sheet Trespa HPL Panels

Using Fire Extinguishers. Leaders Guide and Quiz

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Fluid Collections at the Smithsonian. Michael Kilby, P.E. Joshua Stewart, P.E. Office of Safety, Health & Environmental Management (OSHEM)

DELUGE SYSTEMS FALSE OPERATIONS

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Machine Protection. for Forging Presses Bharat Forge Aluminiumtechnik GmbH & Co. KG. Stationary Fire Protection Case Study

Thermo Scientific ULT Freezers: Superior Thermal Performance

Fire Protection for Printing Machines with High Pressure Water Mist

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Warehouse Protection of Exposed Expanded Group-A Plastics with Electronic Sprinkler Technology

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

SOLIT PROJECT: WATER MIST FIRE SUPPRESSION SYSTEMS AS PART OF THE TUNNEL SAFETY SYSTEM

TUNPROTEC. Active Tunnel Fire Protection

Fixed fire protection solutions

Large scale fire tests with fixed fire fighting system in Runehamar tunnel

Transcription:

Large-scale fire sprinkler tests with the AutoStore compact storage system Magnus Arvidson*, Henry Persson and Maria Hjohlman Department of Fire Technology SP Technical Research Institute of Sweden *) magnus.arvidson@sp.se

The AutoStore system

Technical data and measures Size of bins: Internal size 601 mm by 401 mm by 310 mm. Size of bins: External size 649 mm by 449 mm by 330 mm. Maximum load capacity per bin: 30 kg. Two types of plastic raw material: HDPE or PP (contains carbon black to achieve anti-static properties). Storage height: Up to 16 bins = 5.3 m. Storage area: Large! Largest grid so far contains 70 000 bins.

Video

The starting point regarding fire safety People have not normally access to the storage area of the AutoStore system. The probability for unintentional or intentional ignition caused by humans is therefore low. The design of the robots fulfills the requirements of the electrical safety standard IEC 60950-1 and the probability for fire in a robot is expected to be low. Storage of flammable liquids is not allowed. Storage of commodity containing large amount of expanded plastic material is not likely. Fire tests have proven that a fire starting inside a bin will selfextinguish due to oxygen depletion.

Design benefits from a sprinkler protection point of view. The storage is very compact with narrow flue spaces. Air movement through the array is therefore restricted and a slow fire growth rate is anticipated. The flue spaces are always regular and open. No bins or commodity will block the flues. The storage array is very stable. Collapse or leaning of stacks across flue spaces is not likely to occur during initial fire development. The vertical aluminum supports limits the possibilities for horizontal fire spread.

and disadvantages The bins have solid bottoms that are not permeable to water. No lids are used on the bins and water from sprinklers will initially be collected in the topmost bins. The flue spaces are narrow which will limit the amount of water from sprinklers reaching the seat of a fire. The grid track over the flue spaces will limit the ability for the water from water from sprinklers going directly down the flue spaces.

Previous work Small-scale fire test comparing the fire characteristics of the bins. Large-scale free-burn fire tests. The development of a high-expansion foam protection concept.

Total heat release rate (kw) Large-scale free-burn fire tests 12 000 Total heat release rate 10 000 8000 Ultra fast 6000 Fast HDPE PP Medium 4000 2000 Slow 0 0 5 10 15 20 Time (min)

Test 2 07:00 13:00 16:00 17:00

The objective of the large-scale fire sprinkler tests The development of an efficient sprinkler protection concept able to suppress a fire at an early stage, thereby: - protecting the building, - limit fire spread, and, - limit the overall fire damage. To determine the most effective manual fire-fighting and mop-up strategy.

Large-scale fire tests at Underwriters Laboratories

Footprint: 7 by 10 cells = 4.9 m x 4.8 m Height: 5.3 m

Point of fire ignition at the bottom of this flue space

649 mm 449 mm

Fire ignition source positioned at the bottom of the flue space

The ceiling sprinkler system Wet pipe system. 3.05 m by 3.05 m sprinkler spacing. Upright, K=160, quick-response sprinklers. Ceiling-to-sprinkler deflector distance: 165 mm.

Acceptance criteria The number of operating sprinklers should not exceed 10. The temperatures of a steel beam positioned at the ceiling above the point of fire ignition should not exceed 540 C (1000 F) for more than one minute. Ignition on the inner faces of the stacks of bins surrounding the center 5 by 6 cells not allowed.

Fire test program Test Fill rate of grid Ignition location with respect to ceiling sprinklers Discharge density [mm/min] Ceiling height [m] Clearance [m] 1 Completely full Between four 24.5 mm/min 10.7 m 5.4 m 2 Completely full Under one 24.5 mm/min 10.7 m 5.4 m 3 Two cells partly empty Under one 30 mm/min 8.3 m 3.0 m 4 Completely full Under one 30 mm/min 8.3 m 3.0 m

Test 1: 15:23 [min:sec] first sprinkler activates

Test 1: 15:25 [min:sec] second sprinkler activates

Test 1: 15:27 [min:sec] third sprinkler activates

Test 1: 16:00 [min:sec] visibility is obscured

Test 1: Fire damages (robot removed)

Test 1: Fire damages (robot removed)

Summary of fire test results Test No. of activated sprinklers Activation times [min:sec] Maximum steel beam temperature [ C] One minute average steel beam temperature [ C] Primary extent of damage 1 3 15:23, 15:25, 15:27 44 43 3 by 4 cells 2 1 16:03 39 39 5 by 8 cells 3 4 07:04, 07:23, 08:51, 09:01 91 90 3 by 4 cells 4 1 09:05 28 28 2 by 4 cells

Fire damages after Test 2 ( pipe shadow effect).

Test 2 ( pipe shadow effect).

Average steel beam temperature ( C) Average steel beam temperatures 100 80 Test 1 Test 2 Test 3 Test 4 60 40 20 0 0 10 20 30 40 50 Time (min)

Conclusions Overall, test results were considered very successful. The slow fire growth rated noticed in previous free-burn fire tests was confirmed. The number of activated sprinklers and the average steel beam temperature at the ceiling were well below what was determined as the maximum allowed. Maximum extent of fire damages were, except for Test 2, well below the maximum allowed. However, the fire was controlled in this particular test. No formation of pool fire of melted plastics was observed. No stability problems with the grid. Manual fire-fighting with low-expansion foam nozzles was effective.

BrandPosten: The news magazine from SP Fire Technology published twice a year For a free subscription, contact: brandposten@sp.se

Thank you!