Dräger VentStar Helix heated (N) plus Consumables and Accessories The Dräger VentStar Helix heated (N) plus breathing circuits have been specially designed to suit the high requirements in neonatal ventilation They provide high performance of ventilating neonates in every working mode
02 Dräger VentStar Helix heated (N) plus Benefits Attuned components with high system performance To meet this requirement the VentStar Helix heated (N) plus breathing circuits are tested for compatibility with the Babylog family and ventilators with Neo-option, as well as with BabyFlow plus and other Dräger accessories for neonates With the high quality typical of Dräger, these disposable products support to reduce the risk of cross contamination and offer excellent durability for daily use Additionally, all gas-carrying components in the circuits are free of PVC, DEHP and Bisphenol A Constant heating performance The integrated new heating technology with embedded double helix wire supports homogeneous heat distribution to provide optimum air quality for the patient and was also designed to reduce condensation to a minimum Additionally, the smoothbore material and the clear lumen of the circuits help minimise the flow resistance, support a constant flow and therefore optimise the ventilation performance Differentiation to serve individual user needs Dräger provides two different variants of the new heated circuits for neonates The VentStar Helix dual heated (N) plus with heating in both limbs improves the routine work flow because there is no need for a water trap For customers who are used to and prefer water trap circuit systems, the VentStar Helix heated (N) plus is the right choice With a water trap in the expiratory limb in the customary Dräger design, the user can retain the usual handling attitude and processes The design also makes it easy to remove the condensate Specialised for High-Frequency ventilation As an alternative treatment for premature babies and neonatal patients with critical lung diseases, High Frequency ventilation is being applied more and more frequently Both heated breathing circuits have been specially designed with this application in mind The products both offer an optimised High Frequency performance, in part due to the low compliance Through the combined performance together with the Babylog VN500, Dräger provides a system solution for a powerful and consistent High Frequency Oscillation delivery The VentStar Helix heated (N) plus breathing circuits can be used for common ventilation modes and make an additional circuit change unneccesary as well as saving time through improved workflow Solution for every patient With the two new circuits, Dräger has extended its heated portfolio and can now provide specialised products for the whole range of patient categories For neonates with a tidal volume up to 100 ml the VentStar Helix dual/heated (N) can be used Additionally, the VentStar Helix heated is the best choice for pediatric and adult patients with a tidal volume of at least 100 ml
Dräger VentStar Helix heated (N) plus 03 System Components Soft Connector N For connecting the VentStar Helix heated (N) breathing circuits to the Dräger Neo-Nebulizer 8411030 D-7481-2016 D-42601-2015 Double connector 11ID/15OD For connecting the MP02650 and MP02608 to all Dräger ventilators used with this medical accessory, with the exception of Babylog devices Neonatal Flow Sensors Neonatal flow sensors are based on proven hot-wire anemometry techniques Due to extremely fast and accurate measurement results, as well as extremely low inspiratory and expiratory resistances, it is clearly superior to other methods D-9121-2009
04 Dräger VentStar Helix heated (N) plus Related Products VentStar Helix Heated Breathing Circuits Breathing gas humidification with heated hose systems in mechanically ventilated patients is an essential component in today s intensive care Choosing the right hose system can support the therapy success D-101205-2013 D-35855-2011 BlueSet heated (N) Reusable Breathing Sets The BlueSets heated were developed for the connection to the Fisher & Paykel MR 850 humidifier Thanks to the inspiratory heated breathing circuit and the expiratory water trap, humidified breathing gas is conveyed to the patient On top of that all parts included within the BlueSets can be autoclaved and reused Dräger BabyFlow plus The superior non-invasive respiratory support system, designed to maximize performance and patient comfort D-48842-2015
Dräger VentStar Helix heated (N) plus 05 Technical Data Dimensions Connectors Length Material Breathing hoses Connectors Y-piece Humidifier chamber Water trap (MP02608) All gas-conducting components are PVC-free Device side, Inner 11 mm Patient side, Inner 15 mm 170 m including 40 cm incubator extension EVA, PE, TPE EVA, PE PP PP, SBC, silicone, aluminum PP, PE, TPE, POM, SAN, steel Performance characteristics MP02650 Resistance at 25/5/15/30 L/min inspiratory <0,1/0,1/0,6/2,0 mbar (or hpa or cmh 2 O) Resistance at 25/5/15/30 L/min expiratory <0,1/0,2/0,6/2,0 mbar (or hpa or cmh 2 O) Compliance at 60 mbar (breathing circuit: inspiration and expiration) Leakage at 60 mbar/40 mbar Leakage at 20 mbar Performance characteristics MP02608 <0,8 ml/hpa (or ml/mbar) <30 ml/min <15 ml/min Resistance at 25/5/15/30 L/min inspiratory <0,1/0,1/0,6/2,0 mbar (or hpa or cmh 2 O) Resistance at 25/5/15/30 L/min expiratory <0,1/0,2/1,0/3,3 mbar (or hpa or cmh 2 O) Compliance at 60 mbar (breathing circuit: inspiration and expiration) Leakage at 60 mbar/40 mbar Leakage at 20 mbar <10 ml/hpa (or ml/mbar) <30 ml/min <15 ml/min Warm-up time Humidifier output Invasive ventilation at 4 to 60 L/min Non-invasive ventilation at 4 to 60 L/min 30 min >33 mg/l >10 mg/l Ordering Information VentStar Helix dual heated (N) plus VentStar Helix heated (N) plus Order number MP02650 MP02608 Optional system components Soft Connector N MP03826 Double connector 11ID/15OD MP02655 Neonatal flow sensors 8410185 / 8411130 Related Products VentStar Helix heated MP02606 / MP02607 BabyFlow Plus MP03700 BlueSet heated (N) 8414987 / 8411041 / 8411153
06 Dräger VentStar Helix heated (N) plus Ordering Information Further system components and related products can be found in the accessory catalogue Not all articles are available worldwide
Notes Dräger VentStar Helix heated (N) plus 07
08 Dräger VentStar Helix heated (N) plus Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 91 024 33 1707-1 HQ PP Änderungen vorbehalten 2016 CORPORATE HEADQUARTERS Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Manufacturer: Moislinger Allee 53-55 23542 Lübeck, Germany REGION DACH Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact