PCB Relays Single Relays

Similar documents
IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

CII FCAC-150 Series Relay

Rules for Intruder Alarm Systems

Dated 15-Dec-2000; J. Schilz, subject to change

M7100 Pressure Transducer

UV Flame Supervision System

Auto Technology Company Cyclic Corrosion Test Chamber

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Audible warning devices for external alarm

T7984 A,B,C Electronic Modulating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats

Specification Status: Released

Universal fault annunciator for panel mounting

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

APPLICATION NOTES for LED DISPLAYs

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

Pyroelectric Infrared Sensors

Card SN Relay V23030

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

INTERNATIONAL STANDARD

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Pyroelectric Infrared Sensors

INTERNATIONAL STANDARD

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

SMD 2121 Black Frame MC-S2121BHA

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

Speed and Frequency Seite 1 von 7

USB 3.0 Plug & Receptacle

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

INTERNATIONAL STANDARD

M2500 Engine Controller Installation Manual

Schneider Electric Erie T155 Series

Thermopile Sensor TPS 230 / 3365

Application Notes For LED Displays

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

I/A Series 716C 1/16 DIN Temperature Controller

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Specification Status: Released

Multi Layer Varistor Overvoltage Protection Device

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Temperature Controllers

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

C Note! LGI16... Burner Controls. Building Technologies

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

A5348 Ionization Smoke Detector with Interconnect and Timer

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

User Manual 120/240/300 Outdoor Motion Detector

A5364. Ionization Smoke Detector with Interconnect

INTERNATIONAL STANDARD

Datasheet - MZM 100 ST2-1P2PWREM-A

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

COMITÉ EUROPÉEN DES ASSURANCES

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

LC1350 Level Controller

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

SENSOR SWITCH BRAVOTRONICS CORPORATION 松瓚科技股份有限公司. Item No. VBS080100T Description VIBRATION SWITCH Version 8 Page 1 of 10 Date Nov.

Advanced Ultraviolet Burner Controller

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

Datasheet - MZM 100 ST-SD2PREM-A

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Product Tests Report

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

T P A 120 S 4 S N 1 Y

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Installation Instructions for the

03.03.mmm REV.2 09/01

D5100 Industrial Differential Pressure Transducer

Technical Data Sheet 1.5mm Side Face Infrared LED

BC3250. Blowdown Controller

INSTRUCTION MANUAL (ATEX / IECEx)

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Panel Mounted Fault Annunciator Series

Datasheet - MZM 100 B ST2-SD2PREM-A

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

SECTION AUTOMATIC TRANSFER SWITCHES

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

Draft ES V1.1.1 ( )

General Specifications

SensaGuard TM Integrated Latch Installation Instructions

TEMPERATURE CONTROLLER

Electronic steam boiler controls

T6984F,G Electronic Floating Control Thermostats

U5700 Submersible Liquid Level Pressure Transducer

DB5 Intrinsically Safe Sounder Type DB-5

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Transcription:

Features Small power relay Limiting continuous current 30 A Minimal weight Low noise operation Wave (THT) and reflow (THR/pin-in-paste) solderable versions For twin version refer to Double Micro Relay K For latching (bistable) version refer to Micro Relay K Latching For surface mounted technology refer to SMD versions Typical Applications Car alarm Door control Door lock Hazard warning signal Heated front/rear screen Immobilizer Lamps front, rear, fog light Interior lights Seat control Sun roof Turn signal Window lifter Wiper control 86CR1_3Dco1 Please contact Tyco Electronics for relay application support. Design ELV/RoHS/WEEE compliant THT: sealed type washable THR: sealed type open vent hole Weight Approx. g (0.1 oz.) Nominal Voltage 10 V or 12 V; other nominal voltages available on request Terminals PCB terminals for assembly on printed circuit boards Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS-07-A at standard test conditions unless otherwise noted: 23 C ambient temperature, 20-50% RH, 998.9 ±33.9 hpa. For general storage and processing recommendations please refer to our Application Notes and especially to Storage in the Glossary page 23 or at http://relays.tycoelectronics.com/ appnotes/ Disclaimer All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification. All rights of Tyco Electronics are reserved. All specifications subject to change. Consult Tyco Electronics for latest specifications. 111

Micro Relay K (THT) Dimensional Drawing Micro Relay K THT 12.0 ± 0.2 5.8 ± 0.1 2.5 ± 0.2 0.6 ± 0.2 0. ± 0.1 7.65 ± 0.1 9.9 ± 0.2 A ± 0.2 *) 12.9 ± 0.3 2.8 0.95 ± 0.2 Tyco86etw_se *) Additional tin tops max. 1 mm View of the Terminals (bottom view) 8.5 B C 1.38 0.5 1.72 7.5 +0.05 1.2 3x 0 +0.05 0.5 2 x 0 3 5 1 3.0 3.6 10.2 2 5 x 5 x 0. 0.3 A A B 0. A C 0.3 A TE86etw_an1 Remark: Positional tolerances according to DIN EN ISO 558 112 All specifications subject to change. Consult Tyco Electronics for latest specifications.

Micro Relay K (THR) Dimensional Drawing Micro Relay K THR 86R1_DD2_2 Additional tin tops max. 1mm 86R1_DD1_2 View of the Terminals (bottom view) View of the Terminals (stand off dimension) 86R1_VT3 86R1_VT1 All specifications subject to change. Consult Tyco Electronics for latest specifications. 113

Contact Data THT/ THR THT THT/ THR Typical areas of application Contact configuration Circuit symbol (see also Pin assignment) Resistive/ Wiper load 5) Flasher load Lamp load inductive load V23086-*1*02-A803 V23086-C100*-A602 V23086-***21-A502 Changeover contact/ Make contact/ Make contact/ 1 Form C 1 Form A 1 Form A 3 5 (+) Rated voltage Rated current Limiting continuous current 23 C 85 C 12 V NC/NO 15 A/20 A 20 A 20 A NC/NO 25 A/30 A 30 A 30 A 15 A/20 A 20 A 20 A (-) Contact material Max. switching voltage/power Max. switching current 1) On Off Min. recommended load ) Voltage drop at 10 A (initial) for NC/NO contacts Mechanical endurance (without load) Electrical endurance at cyclic temperature 0/+23/+85 C and 13.5 V Silver based See load limit curve 0 A 2) 0 A 2) /70 A 3) 0 A 2) /100 A 3) 30 A 30 A 30 A 1 A at 5 V Typ. 30 mv, 300 mv max. > 5 x 10 6 operations Resistive load: Motor reverse: Wiper 5) Flasher load: Lamp load: > 3 x 10 5 operations blocked: > 1 x 10 6 operations > 2 x 10 6 operations > 1 x 10 5 operations 20 A on NO-contact > 1 x 10 5 operations 20 A make/5 A make, up to 3 x 21 W, 100 A inrush/ 25 A generator peak - 20 A turn and hazard signal 10 A steady state L = 0.77 mh L = 0.7 mh in sequence 1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V load voltages. 2) For a load current duration of maximum 3 s for a make/break ratio of 1:10. 3) Corresponds to the peak inrush current on initial actuation (cold filament). ) See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/ 5) Avoid using capacitive protection circuits. It will reduce lifetime. Wiper loads always to be tested with original loads. Load Limit Curve 086LLC07 Load limit curve 1 ^= arc extinguishes during transit time Load limit curve 2 ^= safe shutdown, no stationary arc 11 All specifications subject to change. Consult Tyco Electronics for latest specifications.

Circuit Diagram 1 Make contact/1 Form A 1 Changeover contact/1 Form C 5 1 3 5 1 2 2 86ets_ab 86etw_ab Coil Data Available for nominal voltages Nominal power consumption of the unsuppressed coil at nominal voltage Test voltage winding/contact Maximum ambient temperature range 1) Operate time at nominal voltage 2) Release time at nominal voltage 2) 10 V / 12 V (other coils on request) 0.55 W 500 VACrms 0 to +105 C Typ. 3 ms Typ. 1.5 ms 1) See also operating voltage range diagram. 2) Measured at nominal voltage without coil suppression unit. Note: A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. Operating Voltage Range 300 086_OVR03 250 Umax 200 150 100 Does not take into account the temperature rise due to the contact current E = pre-energization 50 Uop (E=0V) 0-0 -20 0 20 0 60 80 100 120 Ambient temperature in C All specifications subject to change. Consult Tyco Electronics for latest specifications. 115

Environmental Conditions Temperature range, storage Refer to Storage in the Glossary catalog page 23 or http://relays.tycoelectronics.com/appnotes/ Test Relevant standard Testing as per Dimension Comments Cold storage IEC 68-2-1 1000 h 0 C Dry heat IEC 68-2-2 Ba 1000 h 125 C Climatic cycling with condensation THT EN ISO 6988 20 cycles Storage 8/16 h Thermal change IEC 68-2-1 Nb 35 cycles 0/+125 C Thermal shock IEC 68-2-1 Na 100 cycles 0/+125 C Dwell time 1 h Damp heat cyclic THT IEC 68-2-30 Db, Variant 2 6 cycles 0 C/55 C/93% constant THT IEC 68-2-3 Method Ca 56 days 0 C/93% Corrosive gas THT IEC 68-2-2 10 days THT IEC 68-2-3 10 days Vibration resistance IEC 68-2-6 (sine pulse form) 10-500 Hz No change in the 6 g switching state > 10 μs Shock resistance IEC 68-2-27 (half sine form single pulses) 6 ms No change in the up to 30 g switching state > 10 μs Solderability Hot dip 5 s Aging 3 ( h/155 C) THT IEC 68-2-20 Ta, Method 1 215 C for leaded process (Tm = 183 C) THR IEC 68-2-58 25 C for Pb-free process (Tm = 217 C) Resistance to soldering heat Hot dip 10 s with thermal screen THT IEC 68-2-20 Tb, Method 1A 260 C THR IEC 68-2-58 260 C Preheating min 130 C Sealing THT IEC 68-2-17 Qc, Method 2 1 min/70 C THR Open vent hole Ordering Information Part Numbers (see table below for coil data) Contact Contact Enclosure Soldering Relay Description Part Number Arrangement Material Technology V23086-C1021-A502 8-116000-7 1 Form A: lamp load Silver based Sealed THT V23086-C1001-A602 9-116000-6 1 Form A: flasher load Silver based Sealed THT V23086-C1001-A03 0-1393280-6 1 Form C Silver based Sealed THT V23086-C1002-A03 1-1393280-1 1 Form C Silver based Sealed THT V23086-C1002-A803 On request 1 Form C Silver based Sealed THT V23086-R1801-A03 6-11920-0 1 Form C Silver based Open vent hole THR V23086-R1802-A03 5-11920-9 1 Form C Silver based Open vent hole THR V23086-R1802-A803 7-11967-8 1 Form C Silver based Open vent hole THR V23086-R1821-A502 6-11918-8 1 Form A Silver based Open vent hole THR 116 All specifications subject to change. Consult Tyco Electronics for latest specifications.

Coil Versions Coil Data Rated Coil Coil Resistance Must Must Allowable Overdrive 1) for Voltage ±10% Operate Voltage Release Voltage Voltage (V) Micro K THT/THR (V) (Ω) (V) (V) at 23 C at 105 C V23086-**001-**** 12 25 6.9 1.5 27 18 V23086-**002-**** 2) 10 2) 181 5.7 1.25 22 15 V23086-**021-**** 12 181 6.9 1.5 22 15 V23086-**801-**** 12 25 6.9 1.5 27 18 V23086-**802-**** 10 181 5.7 1.25 22 15 V23086-**821-**** 10 181 6.9 1.5 22 15 1) Allowable overdrive is stated with no load applied and minimum coil resistance. 2) See operating voltage range. Standard Delivery Packs (orders in multiples of delivery pack) Micro K THT/THR: 2000 pieces All specifications subject to change. Consult Tyco Electronics for latest specifications. 117