Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Similar documents
GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Installation & Operation Manual

Duct Humidity/Temp Sensor

Outside Air Humidity & Temperature Sensor

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Room Humidity/Temp Sensor

Model SRPM Room Pressure Monitor. Installation and Operating Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Deluxe Discharge Alarm

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

OPERATION MANUAL Model 8011 & mA

CO2 Sensor User and Installation Guide

Model 5190-E Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe

Model 4001 Series Single Channel Controller

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Duct Temperature Sensors

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Environmental Monitoring SmartSlot Card

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

MBCE-110/230FR Flame Sensor Module

Installation Guide

OPERATION MANUAL MODEL & ACCELEROMETER

Installation & Operation Manual

Propane Fume Detection System

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Potential Applications

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

NT DUAL CHANNEL DISPLAY. User Guide

CLEANROOM MONITOR CR3A Network - Installation Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Long-Range Barrier Sensors

* These Remote Mics must be SPRM-GP

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

MBCE-110/230UV Flame Sensor Module

MBCE-110/230FR Flame Sensor Module

HIH-4030/31 Series Humidity Sensors

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

RAM3 Remote Alarm Module

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

OPERATION MANUAL MODEL 4610 ACCELEROMETER

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

OPERATION MANUAL MODEL 805 ACCELEROMETER

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

RAM 50 Series Operation Manual

OKB, OKD, & OKH Series

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Propane Fume Detection System With Solenoid Valve Control

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Model # Airflow Monitor Warranty. Installation, Operation, Maintenance Manual. Analog Airfl ow Monitor Model Number #51403

Installation & Operation Manual

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Figure 1. Figure 2. See notes 1 and 2 below.

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

FW-RA-LED Remote Multiplex Annunciator Panels

XT Series Thermostats

Installation, Operation & Service Manual

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

PodView Level Indicator LI40 Series Manual

Radiant Thermostat 519

Controllers. Instruction Manual WARNING

Carbon Dioxide Sample-Draw Detector Operator s Manual

Instruction Manual WARNING

! "! # Please read these installation and operating instructions completely and carefully before starting.

HIH-4010/4020/4021 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Propane Fume Detection System With Solenoid Valve Control

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Mark 25 Ultrapure Water Conductivity Analyzer

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

esense CO2 Transmitter and Alarm

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

HIH-5030/5031 Series Low Voltage Humidity Sensors

Long Range Radio Alarm Transmitter

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Active Infrared Multi Beam Sensors

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

A10. Installation & Operation Manual. Flow Switch. For the latest version of this manual, visit kteksolidslevel.com.

Transcription:

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions 1.0 GENERAL INFORMATION Every SRH humidity sensor product is tested and calibrated before shipment. Setra s Humidity Sensor family consists of a wall mount, duct mount, and outside air unit. This product line expands the solution opportunities for the HVAC/building automation market and other relative humid ity monitoring applications. All models utilize a field-replaceable sensor module, NIST traceability, accuracies of ±2%, ±3%, ±5%, active or passive temperature sensing, and a durable capacitive sensor capable of full-scale 0 to 100% RH measurement. 2.0 MECHANICAL INSTALLATION 2.1 Environment The operating temperature limits of the SRH model are as follows: Operating Temperature Range -40 F to 140 F (-40 to 60 C) Storage Temperature -40 F to 158 F (-40 to 70 C) 2.1 Wall Mount It is important to find a place within a room where the transmitter can be exposed to unrestricted air circulation that will represent the average humidity and temperature within that space. Try to avoid any locations that may be exposed to fumes, extreme temperatures, and high moisture content. Also, make sure the location is on an indoor wall that is about 4 to 6 feet above the floor. For ease of 2.81 71.50 Model SRH Wall Mount Unit Top View Security Screw Security Latch Front View To open wall unit, back out the security set screw (if used), then press the security latch inward and lift-up cover. 1 4.69 119 3.30 84 2.37 60 Wall Mount - Back Plate in. mm 1.41 36

2.2 Duct Mount For proper operation, it is necessary to locate the transmitter in the center of a section of duct that receives adequate air flow. Conversely, it must be free of fans, corners, heating/cooling coils, or any other equipment/ environmentals that could adversely affect relative humidity measurement. 5.1 130 2.69 68 3.72 94 Duct Mount Base 1.11 28 in. mm X2 0.180 5 Model SRH Duct Unit shown w/sensing probe Insert sensing probe through hole (5/8 dia. minimum) and attach full assembly via the two mounting holes on each side. 2.3 Outside Air Mount The outside air configuration is supplied with a mounting bracket and two 10-16 x 1/2 hex head screws. Locate a position on the building that is clear of exhaust ducts, high exposure to the sun, direct rain, or other outdoor factors that could adversely affect the operation of the unit. Ideally, a sheltered area (under an eave) on the north side of the building is best to protect from the above effects. 5.00 127 X2 0.550 14 Model SRH Outside Air Unit shown w/porous Weather Shield 4.05 103 3.31 84 2.81 71 1.75 44 Outside Air Mounting Plate 2 X8 0.325 8.3 X2 0.154 4 in. mm

3.0 ELECTRICAL INSTALLATION 3.1 Wiring Match your transmitter with the corresponding diagrams and set the jumpers and wire accordingly. Ensure that all of the installation and wiring is in compliance with all national and local codes. Use 18-22 AWG shielded, twisted pair, copper conductors. Caution: Do not bundle transmitter wires with AC power wires. Shield must be connected to earth ground for CE compliance. Wall Mount Connector/Jumper Locations - Inside cover Duct and Outside Mount Connector/Jumper Locations - Board Assembly/Duct Probe 3

Wiring 0-5 V/0-10 V Output Units (3-wire / T0, T1 & T2) Shield TH2 TH1 / +V_TMP RTN_TMP/ +V_RH RTN_RH / COM +EXC 6 Earth Ground Connection 5 Thermistor/PRTD 4 3 RH (0 to 5V/0 to 10V) Output 2 Ground 1 Vin Selectable Outputs Note: Unit shipped in 0 to 5V Mode. Move jumper to right for 0 to 10V Operation 5V 10 V H Wiring 4 to 20 ma Output Units (2-wire / T0, T1 & T2) Shield TH2 TH1 / +V_TMP RTN_TMP / +V_RH RTN_RH / COM +EXC 6 Earth Ground Connection 5 Thermistor/PRTD 4 3 NC 2 RH (4 to 20 ma) Output 1 Vin Wiring 0-5 V/0-10 V Output Units (4-wire / T3 & T5) Shield TH2 TH1 / +V_TMP RTN_TMP/ +V_RH RTN_RH / COM +EXC 6 Earth Ground Connection 5 NC 4 Active Tmp (0-5V/0-10V )Output 3 RH (0 to 5V/0 to 10V) Output 2 Ground 1 Vin 5V Selectable Outputs 10 V 5V H 10 V T Selectable Tspan 40 50 60 ( C) Note: Unit shipped in 0 to 5V mode with Tspan set to 60 C. Move Tspan jumper to select optional ranges. 4

Wiring 4 to 20 ma Output Units (3-wire / T3, T5) Shield TH2 TH1 / +V_TMP RTN_TMP / +V_RH RTN_RH / COM +EXC Selectable Tspan 6 Earth Ground Connection 5 N/C 4 N/C 3 Active TMP (4-20 ma) Output 40 50 60 2 RH (4 to 20 ma) Output ( C) 1 Vin Note: Unit shipped with Tspan set to 60 C. Move Tspan jumper to select optional ranges. 5

4.0 CALIBRATION All relative humidity products are fully tested and calibrated prior to shipment in accordance with the National Institute of Standards and Technology (NIST), the highest quality standard available. Once installed in the field, no calibration of the units is required. Instead, this product suite features field-replaceable sensor modules that allow the end user to replace the sensors on-site. This eliminates time consuming and costly factory calibration, while reducing downtime during service intervals. Additionally, the duct mount probe is easily accessed by taking off the front cover, removing the sensor board assembly, and replacing the sensor module on the tip of the sensor board. This further contributes to a more user-friendly, lower cost product line that is focused on customer needs and ease of use. 4.1 Remove/Install the Sensor Tip Note: Power Must be removed from the main PCBA prior to replacing the sensor tip module. Failure to comply could possibly damage the sensor tip module Wall Mount White Retaining Clip Outdoor and Duct Mount 6

Replaceable Sensor with Sintered Filter White Retaining Clip Top View Side View (PCB to PCB) Remove the white retaining clip (shown above and on page 6). Remove the sensor tip module by holdng the sides of the sintered filter along the pcb edges. Then gently pull the sensor tip module out of the mating connector. Gently push the replacement sensor tip module into the mating connector (as shown) and replace the retaining clip to secure the connection. 4.2 Ordering Information - Replacement Sensor Assembly* Example: Order Part No. SRH3-2P-T0 = Sensor Assembly with 2% accuracy, RH only. S R H 3 Model Accuracy Temperature Outputs SRH3 = SRH 2P = 2% T0 = None (RH only) 3P = 3% T1 = 10KΩ NTC (passive) 5P = 5%** T2 = 1000Ω RTD (passive) T3 = -50 C to 60 C (active) T5 = -10 C to 60 C (active) *SRH1 units originally ordered with either a T3 or T5 temperature option MUST be replaced with the same T(x) version. **Not available with T3 or T5 option. 7

5.0 SPECIFICATIONS RH Performance Data Sensing Element Capacitive Polymer Humidity Operating Range 0 to 99% RH (non-condensing) Accuracy at 68 F (20 C) 2%, 3%, 5% Hysteresis <1.5% Repeatability <0.5% Long Term Stability <1%/year @ 68 F (20 C), 50% RH Electrical Data Signal Outputs Current (2-wire ckt.) 4 to 20 ma Field Selectable Voltage (3-wire ckt.) 0 to 5 VDC, 0 to 10 VDC Excitation 0 to 10 VDC 13.5 to 30 VDC 0 to 5 VDC, 4 to 20 ma 12 to 30 VDC Maximum Load (Current only) Ω = (Supply - 10) / 0.02 Electrical Termination Pluggable Terminal Block (5mm Pitch) Wiring Protection Reverse Excitation CE Compliance EMC Directive 2004/108/EC Temperature Sensing Options (Passive) T1 Thermistor Output NTC 10K Ω @ 77 F/25 C (Direct Connect) Type II T2 RTD Output Temperature Sensing Options (Active) Signal Ouput Options (includes humidity output): Current 8 1000 Ω @ 32 F/0 C (Direct Connect) 385 Platinum Curve 4 to 20 ma Field Selectable Voltage 0 to 5 VDC, 0 to 10 VDC Available Ranges: Accuracy: T3 (-50 C to 60 C) ±0.6 C (20 C @ 50%) T5 (-10 C to 60 C) ±0.4 C (20 C @ 50%) Environmental Data Operating Temperature F ( C) -40 to 140 (-40 to 60) Storage Temperature F ( C) -40 to 158 (-40 to 70) Moisture Resistance IP65, NEMA-4 (Duct & Outside Air) Solar UV Resistance (Outside Air) Flammability Rating 94-V0 Compliance RoHS and CE Compliant Physical Description Enclosure Wall Mount ABS 94-V0 Duct & Outside Air Poly Carbonate 94-V0 Probe (Duct & Outside Air) Weather Shield (Outside Air) Aluminum Porous Polyethylene

6.0 DIMENSIONAL DRAWINGS 5.60 5.10 142.2 129.5 2.81 71.50 2.68 68.1 4.69 119 2.38 60.4 8,7 221 0.98 24.7 Duct Probe (5/8 dia.) Security Latch Wall Mount Duct Mount 6.10 154.9 2.38 60.4 4.50 114.4 4.04 102.6 2.68 68 12.52 318 4.05 102.7 Duct mount shown w/optional Duct Flange Outside air 9 in. mm

7.0 DUCT MOUNT INSTALLATION P/N 888415 1.50 38.10 4x ø.180 4.57 2.25 57.15 1.75 44.45 1.125 28.58 2.25 57.15 3.00 76.20 Optional Duct Flange (Top View) in. mm 10

1.62 41.25 Conduit Hole 1.125 dia. 28.5 Optional Duct Flange (Side View) 0.68 17.27 in. mm Mounting the transmitter using the optional duct flange. 1. Drill a 1.125 (28.5 mm) diameter hole into the duct 2. Insert the tapered bushing side into the conduit hole. 3. Press in and all around the outer exposed edge of bushing so the bushing groove captures the inside edge of the conduit. 4. Secure flange using #10-16 x 1/2 self-drilling screws (recommended) 5. Insert duct probe to desired length plus 1/2. Pull back unit approximately 1/2 to create seal. Note: To remove, simply twist duct housing side to side while pulling outward. 11

8.0 RETURNING PRODUCTS FOR REPAIR When returning a product to Setra Systems, the material should be carefully packaged and shipped prepaid to: Setra Systems, Inc. 159 Swanson Road Boxborough, MA 01719-1304 Attn: Repair Department To assure prompt handling, please refer to return instructions on our Web site at http://www.setra.com/tra/repairs/cal_rep.htm. 9.0 WARRANTY AND LIMITATION OF LIABILITY SETRA warrants its products to be free from defects in materials and workmanship, subject to the following terms and conditions: Without charge, SETRA will repair or replace products found to be defective in materials or workmanship within the warranty period; provided that: a) the product has not been subjected to abuse, neglect, accident, incorrect wiring not our own, improper installation or servicing, or use in violation of instructions furnished by SETRA; b) the product has not been repaired or altered by anyone except SETRA or its authorized service agencies; c) the serial number or date code has not been removed, defaced, or otherwise changed; and d) examination discloses, in the judgment of SETRA, the defect in materials or workmanship developed under normal installation, use and service; e) SETRA is notified in advance of and the product is returned to SETRA transportation prepaid. Unless otherwise specified in a manual or warranty card, or agreed to in writing and signed by a SETRA officer, SETRA pressure, humidity, and acceleration products shall be warranted for one year from date of sale. The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not limited to, any implied warranty of merchantability for a particular purpose. SETRA s liability for breach of warranty is limited to repair or replacement, or if the goods cannot be repaired or replaced, to a refund of the purchase price. In no instance shall SETRA be liable for incidental or consequential damages arising from a breach of warranty, or from the use or installation of its products. No representative or person is authorized to give any warranty other than as set out above or to assume for SETRA any other liability in connection with the sale of its products. For all CE technical questions, contact Setra Systems, USA. EU customers may contact our EU representative Hengstler GmbH, Uhlandstr 49, 78554 Aldingen, Germany (Tel: +49-7424-890; Fax: +49-7424-89500). SS-SRH Rev. B 2/25/2010 159 Swanson Road, Boxborough, MA 01719-1304 Tel: 800-257-3872/978-263-1400 Email: sales@setra.com; Web: www.setra.com 12