Axis luminaires allow the use of integrated controls such as daylight sensors (DS), occupancy sensors (OS) combination daylight/ occupancy sensors (DOS) and wireless control (WC). These options can be seamlessly integrated into our luminaires. The control system could be used to optimize the lighting of the space by reducing energy consumption through daylight harvesting and occupancy, thereby improving the overall interior environment and allowing for LEED credits. for other options. The integrated control systems offered are: DAYLIGHT HARVESTING (DS): With Daylight sensors, maximum illumination output is reduced according to the available amount of natural light. By reducing maximum illumination output, energy consumption is reduced by up to 20 percent in a process known as Daylight Harvesting. DAYLIGHT HARVESTING AND OCCUPANCY (DOS): A combination of Daylight & Occupancy sensor. In one form factor. ENLIGHTED INTEGRAL (EN) / ENLIGHTED REMOTE (ENR): Shown with Luxsense EC-DIR-WH, FD-301 Luxsense, Micro Luxsense Shown Philips EasySense OCCUPANCY (OS): When a room is vacated, occupancy sensors ensure the light will be turned off after a programmed delay as well as ensuring that light remains on while the room is occupied. WIRELESS CONTROL (WC): Wireless Control Dimming, enabling you to control and manage LED luminaires. Wireless control can be combined with DOS sensor. With wireless smart lighting control, luminaires themselves can become addressable nodes in a network. CONTROL SENSORS Shown with FS-205 FS-205, FS-355, FS-155 - Line Voltage FS-505, FS-505C A combination of Daylight, Occupancy & Temperature autonomously control illumination levels, monitor occupancy and environmental conditions. Data is transmitted wirelessly to the Enlighted networked management system. Shown DFCSJ-OEM-OCC DFCSJ-OEM-OCC, DFCSJ-OEM-RF, DFC-OEM-DBI INSTALLATION EXAMPLE Sensor location option controls option * Incorporating IC controls may affect the length of the luminaire. Please contact factory for more details. 1 / 5
DAYLIGHT SENSOR (DS) BRAND LUTRON PHILIPS WATTSTOPPER 202 LRF2-DCRB-WH EC-DIR-WH Luxsense LRL1220/00 Micro Luxsense LS-102 LS-301 FD-301 Tek Wet Beam 2 / 5
BRAND BRAND AXIS CODE LUTRON TRIPAK WIRELESS LRF2-OCR2B-P-WH 3 / 5 FS-205v2 OCCUPANCY SENSOR (OS) FS-355 FS-155 & Ambient Light WATTSTOPPER FS-305 / FS-305 C FS-505 (Staircase) / FS-505C (Open Area) Ultrasonic Occupancy FM-105 High Frequency Occupancy (Wet) 202 Beam2, 3, 4, 6 except Beam 2 ACUITY MSD PDT 7 Dual Tech PIR+Ultrasonic Remote sensor only CovePerfect Tek Wet Beam
DAYLIGHT AND OCCUPANCY SENSOR (DOS) BRAND LUTRON PHILIPS ENLIGHTED LRF2-DCRB-WH (Daylight Sensor) LRF2-OCR2B-P-WH (Occupancy Sensor) EasySense SNS200 (Group) EasySense SNS102 (Stand alone) SU-5E-00 SU-4E-00 Daylight, Occupancy & Temperature CS-D2 Ruggedized Sensor RS-2O-S1 202 Tek Wet Beam FS-D22 4 / 5
WIRELESS CONTROL DIMMING (WC) WITH SENSOR WITHOUT SENSOR BRAND ACUITY MAGNUM LUTRON LUTRON OSRAM M9-OPUS-MLD Acuity Controls RES7N with EldoLED M9-OPUS- ML10V M9-OPUS-HB- KO10V-L5 VIVE INTEGRAL FIXTURE CONTROL WITH SENSOR (DFCSJ-OEM-OCC) VIVE INTEGRAL FIXTURE CONTROL WITHOUT SENSOR (DFCSJ-OEM-RF) OSRAM CLM (0-10V) OSRAM CLM (DEXAL) 202 Tek Wet Beam 5 / 5