SECTION HEATING TERMINAL UNITS

Similar documents
DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

SECTION CONVECTION HEATING AND COOLING UNITS

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION CONVECTION HEATING AND COOLING UNITS

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

SECTION (15767) - UNIT HEATERS

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION AIR DUCT ACCESSORIES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION AIR COILS

SECTION AIR HANDLING UNIT

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

TCV-1. Convector Steam and Hot Water Unit Heaters

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Hydronic Heating Solutions

SeasonMaker ThinLine Fan-coil Units

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

Construction Standards Page

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Product Specifications. Vertical Floor Consoles By First Co.

C. Samples for Initial Selection: For units with factory-applied color finishes.

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econo-Line Enclosures

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

SECTION HEATING BOILERS

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

DOCUMENT TABLE OF CONTENTS

SECTION AIR OUTLETS AND INLETS

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

.2 Section Waste Management and Disposal.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

A. Codes and Standards that are Standard at the University:

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

BASE-RAY CAST IRON BASEBOARD RADIATION

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

SeasonMaker ThinLine Fan-coil Units

SECTION FIRE EXTINGUISHER CABINETS

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

UFGS (August 2008) UFGS (January 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

SECTION HEATING BOILER FEEDWATER EQUIPMENT

UFGS (May 2014) UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SECTION FAN COIL UNITS

. ECTION METERS AND GAGES

DIVISION 23 - HVAC HVAC

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. This Section includes the following emergency plumbing fixtures:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Rittling Element. Catalog

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

HEATING THE HOME UNIVERSITY 0 F ILLINOIS BULLETIN REVISED BY DONALD E. BROTHERSON, A. I. A.

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

SECTION AIR COILS

Hydronic Expansion Tanks THE ONE THAT STARTED IT ALL

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Convectors Steam / Hot Water November, 2009

SECTION WATER HEATERS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Choosing Heating and Cooling Systems

Peerless Boilers. Series MI. Residential Gas Boilers

Commercial Packaged Rooftop Systems

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

Cabinet Unit Heaters Type CHF & CHB

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Cabinet Unit Heaters Steam / Hot Water

A. This Section includes air-handling units with coils for indoor installations.

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

America s favorite hot water baseboard radiation

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Transcription:

SECTION 15830 HEATING TERMINAL UNITS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Baseboard or Fin-Tube Radiation. 2. Convectors. 3. Cabinet Unit Heaters. 4. Unit Heaters - Hot Water. 5. Hydronic Radiant Ceiling Panels. 6. Unit Ventilators B. Related Sections: 1. Section 15010 - Basic Mechanical Requirements. 2. Section 15050 - Basic Mechanical Materials and Methods. 3. Section 15511 - Hydronic Piping and Specialties. 4. Section 15521 - Steam and Condensate Piping and Specialties. 5. Section 15835 - Electric Heat. 6. Section 15950 - Controls. 1.02 REFERENCES A. Institute of Boiler and Radiator Manufacturers (IBR), superseded by Hydronics Institute. B. Hydronics Institute (HYDI). 1.03 SYSTEM DESCRIPTION A. Design Requirements: 1. General: a. Expand Part 2 Product specification minimums to include specific project requirements. JULY 2012 UCB STANDARDS 15830-1

b. Baseboard radiation is preferred for heating the exterior wall of all perimeter rooms. Use radiant ceiling panels only as a last choice. c. Use convectors where architectural features cause greater capacity requirements than baseboard radiation can provide in the available space. d. Use cabinet unit heaters at building entrances where greater capacity and quick response is necessary to adequately handle rapid changes in space temperature. e. Select cabinet unit heaters and unit heaters on low speed capacity of three speeds to provide quiet operation under normal conditions and have extra capacity at higher speeds for extreme conditions. Specify a fan-speed switch. f. For all the product types listed in this standard, specify the appropriate pressure and temperature ratings. g. When providing any of the product types listed in this standard, allow for thermal expansion and contraction as required. 1.04 QUALITY ASSURANCE A. Radiation capacities shall be in accordance with HYDI Standard for "Testing and Rating Code for Finned-Tube Commercial Radiation". PART 2 - PRODUCTS 2.01 FIN-TUBE RADIATION A. Manufacturer: Dunham-Busch C. Enclosures: 1. Fabricated from 16 gage steel. 2. Manual control dampers with knob actuators. 3. Enclosure to be readily removable between each mullion bracket and support enclosure for access to manual valves, balance cocks and air vents. JULY 2012 UCB STANDARDS 15830-2

4. Enclosures shall be furnished less access panels. Provide hinged access panels separately, to be installed after piping and radiation covers are in place, to all manual valves, balance cocks, and air vents. 5. Enclosures shall have sloped top with manual damper or flat top with front outlet and manual damper. 2.02 CONVECTORS Dunham-Bush C. Enclosure: 1. Minimum 16 gage steel fronts and tops, 18 gage on backs. 2. Manual control damper with knob actuator. 3. Non-recessed types shall have sloping tops. 4. End caps where butted to wall, and on exposed ends. 2.03 CABINET UNIT HEATERS McQuay Modine JULY 2012 UCB STANDARDS 15830-3

C. Cabinet: 1. Minimum 16 gage furniture grade steel. 2. Non-recessed types shall have sloping tops. D. Fans: 1. Statically and dynamically balanced to eliminate vibrations. E. Motors: 1. Three speed. F. Filters: 1. One inch thick, disposable, located in a frame in the return air stream, easily removable for service by removing front access panel. G. Control: 1. Internal unit mounted, pre-wired 3-speed switch and "off" in addition to automatic temperature controls as specified in Section 15950 - Controls. 2.04 UNIT HEATERS - HOT WATER McQuay Modine C. Cabinet: 1. Heavy gage steel. D. Fans: 1. Horizontal or vertical propeller type. E. Control: JULY 2012 UCB STANDARDS 15830-4

1. As specified in Section 15950 - Controls. F. Louvers: 1. Movable for lateral and horizontal diffusion. 2.05 HYDRONIC PANEL RADIATORS A. Manufacturer: Runtal B. Performance: 1. Panel performance and water pressure drops shall be certified by an independent certified testing laboratory. C. Finishes: 1. Baked enamel PART 3 - EXECUTION 3.01 INSTALLATION A. In general, for project specifications, remove "Design Requirements" sub-paragraph A in Part 1, paragraph 1.03, "System Description" of this Design Guide and use list to expand on specific requirements of installation. END OF SECTION 15830 JULY 2012 UCB STANDARDS 15830-5