DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Similar documents
DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

CHEAT SHEET: SPECTRA V2.1

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Property of Monitronics Inc

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

System Introduction. 1.1 Specifications S E C T I O N 1

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

System Introduction. 1.1 Specifications

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

4-PGM Expansion Module

8-zone Expansion Module

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

System Programming Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

ELT-KLED EliteSuite LED Keypad Installation Manual

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Series. NX-4-EUR Control Panel. Installation manual

Property of Monitronics Inc

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

DSC PowerSeries NEO Quick Start Guide

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Contents. Glossary

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Control/Communicator Installation Manual

User s Information Guide R2A

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Quick Programmer s Manual

GLOBAL. InstallatIon & operation manual

Programming Worksheets

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

Technical Manuals Online! - Keypad Programming. Basic Programming

All-In-One Wireless Security System V1.0. Model #: MG-6060

NetworX Series NX-4V2 Control Panel Installation and Startup

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS TABLE OF CONTENTS 1

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

SPECTRA 1728, 1738 CHEAT SHEET:

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

2000 Series. Program Entry Guide. Control Panels

10-Zone Spectra LED Keypads

PC4020 v3.2 Installation Manual DLS-3 v1.3

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Cerber C Zone and 2-Partition Burglary Control Panel for your home and office. Hook-Up & Programming Book[draft] / version 1.

MG5000 MG5050 SP65 SP4000 SP5500 SP6000 SP7000. User Guide. Always Armed, Never Disarmed. Downloaded from manuals search engine

INSTALLATION MANUAL PC56O. Version 1.OA

CC408. Quick Reference Guide Solution 880

P Zone Expandable Hybrid Security System

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

LCD and 16-Zone LED Keypads. User s Manual

Digiplex LED Keypads User s Manual

IDS816 User Manual H Issued January 2009

Solution 862 Installation Manual ISSUE 1.30

Version 1.03 January-2002 USER S MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

CC488. Quick Reference Guide Solution Ultima 880

PC4020 v3.2 Installation Manual DLS-3 v1.3

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

NESS 5000 SERIES DIALLER

HARDWIRED CONTROL PANELS

Always Armed, Never Disarmed User Guide

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INSTALLATION MANUAL & PROGRAM RECORD SHEET

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

SCORPION Z16040C, Z8040C and Z5120C

VAP304 PRO INSTALLATION & OPERATION MANUAL

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

EVO192 v3.0 Fire and Burglary What s New

ITI Caretaker Basic Commands

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

First Alert 1200C Installer Notes M. Leuck

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

Uplink Remote Installation Guide 5500EZ

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

1. Introduction. 2. Product overview

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Table of Contents. Appendix A Special Characters 31

Long Range Radio Alarm Transmitter

Installation Manual Premier 412/816/832. Issue 10

Transcription:

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel CAUTION: It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality. Do not route any wiring over circuit board. Full panel testing, and signal confirmation, must be completed by the installer. Wiring the MN01-4G to the Alarm Panel NEW FEATURE: For MiNi01-4G-V2, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialer. Therefore, wiring the white wire and programming of the status PGM of the panel is optional. Wiring the white wire is necessary only if the Open/Close reporting is disabled. IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure. 1 of 6

Programming the Power832/PC5010 Alarm Panel via the Keypad Enable Contact ID reporting: LED indication on Keypad Keypad Entry *85010 To enter in Programming mode. 301 123456# Action Description To enter Change phone number menu for 1 st number (302 or 303 for 2 nd or 3 rd ) Enter actual or non-existing number (any number will do, 123456 is an example). 310 To enter Change account number menu 1111 Enter 4-digit account number to receive the events from (1111 is an example). If you want to enter partition 2 account number type 311 followed by 1112# (whatever number you want to see) otherwise leave empty. 360 To enter Communicator format 03# Press 03 for Contact ID and # to save (if there are two partitions enter 0303#) 320 To enter Alarm reporting code for zones 1 through 8 3131313131313131 Enter a Contact ID code for each zone. If you have less than 8 zones, just press # after the last one. them (321 is for 9-16, 322 for 17-24, 323 for 25-32). 324 To enter Restore report codes for zones 1 through 8. 3131313131313131 Enter a Contact ID code for each zone, the same as the one entered in the previous step Alarm reporting. them (325 is for 9-16, 326 for 17-24, 327 for 25-32). 339 To enable Arm report codes for zones 1 through 8. *1*2*1*2*1*2*1*2* 1*2*1*2*1*2*1*2 Enter a Contact ID code for each zone (A2 is the Contact ID code for ARM ). if you have less than 8 zones, just press # after the last one. them (340 is for 9-16, 341 for 17-24, 342 for 25-32). 344 To enter Disarm report codes for zones 1 through 8. *1*2*1*2*1*2*1*2* 1*2*1*2*1*2*1*2 Enter a Contact ID code for each zone, the same as the one entered in the previous step Arm. them (345 is for 9-16, 346 for 17-24, 347 for 25-32). 380 To enter First communicator option code. 361 To activate Communications enabled until LED on Zone 1 is lit. Make sure that all other LED s are off -> press the respective number until only Zone 1 is lit Red and the others are dim. To enter Partition 1 or 2 Alarms and Restores (361 partition 1, 362 partition 2). 2 of 6

To activate 1 st Telephone Number until LED on Zone 1 is lit. 363 To enter Partition 1 or 2 Tampers and Restores (363 partition 1, 364 partition 2). To activate 1 st Telephone Number until LED on Zone 1 is lit. 365 To enter Partition 1 or 2 Tampers and Restores (365 partition 1, 366 partition 2). NOTE some stations require this to be disabled. Additional reporting options: LED indication on Keypad Keypad Entry Action Description 329 Priority Alarm & Restores Keypad panic key zone programming. 1*1*, *11*, 2*1 # Fire = 1A, Medical = AA, Panic = 2A (*1 is equivalent to A) 343 Closing Duress and master code section *1 AA 348 Duress and master code section *1 AA 349 Maintenance codes alarm. See guide pg. 5 350 Maintenance codes restore. See guide pg. 5 352 Test Transmission reporting code *1*2# 367 Maintenance & restore alarms on 368 Test Transmissions on 378 Test transmission time - 24hr time 3 of 6

Program Key-switch zone and output: LED indication on Keypad Keypad Entry Action Description Armed: steady Red *85010 To enter in Programming mode. Ready: steady Green 202 To enter Partition zone assignments. Ready: steady Green Turn ON (the corresponding LED will be lit) only the zones that you intend to use the rest must be OFF (LEDs are dim) in our case LEDs 2-7 will be OFF. Armed: steady Red 001 Zone 1 Keyswitch. Ready: steady Green 22# Enter 22 to program zone Type Keyswitch. Armed: steady Red 013 To program EOL zones. Ready: steady Green 1 must be OFF to set the zones to end-of-line wiring configuration. Armed: steady Red 009 To program Output 1. Ready: steady Green 05# 05 is Armed Status. Ready: steady Green # Exit Programming mode. References: Binary Programming To program A thru F into programming slots, press the * key. The READY light will flash. While flashing, the button 1 = A, 2 = B, 3 = C, 4 = D, 5 = E, 6 = F Press * again and the keys revert back to normal. See full contact ID reporting codes on page 6 of this manual. 4 of 6

Wiring the MN01-4G and the MN01-RNGR to the Alarm Panel for remote Upload/Download Programming the DSC PC5010 Alarm Panel via the Keypad for remote Upload/Download Program the Panel for Upload/Download: Display Keypad Entry Action Description Date / Time *8 + Inst. Code Enter programming menu. Default installer code is "5555" Enter section 401 First downloading options toggle menu Toggle option 1,3,6# 1 and 3 should be disabled. 6 should be enabled. Enter section 403 DLS downloading access code. Default for PC5010 is "501000". Enter Hex Data 501000# Set this field's value to its default. Enter section 404 Panel ID code. Default for PC5010 is "501000". Enter Hex Data 501000# Set this field's value to its default. Enter section 405 Double call timer address Enter Data 000# Disable double call Enter section 406 Number of rings address Enter Data 001 Set the panel to answer on the first ring. # Exit Programming mode. 5 of 6

6 of 6