MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Similar documents
Multistage Centrifugal Blowers

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

MARLOW PUMPS RECIRCULATION

Fuji Electronic VFC 084P-5T

Rotodynamic Pumps INTRODUCTION:

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers

A. Codes and Standards that are Standard at the University:

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Wilo IL Vertical Split-Coupled Inline Pumps

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

SECTION STEAM CONDENSATE PUMPS

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Blowers - HIGH PRESSURE BLOWER - HIGH VACUUM BLOWER

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Centrifugal Fans, Non-Overloading, Backward Inclined

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Direct Fired Heater Model AD Specification

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Introduction to Fans. The Basics of Fan Principles and Terminology

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Specially Designed Waste Water & Sewage Pumps

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Blowers. Side channel compressors and vacuum pumps. Your Choice, Our Commitment

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Industrial. Solutions brands you trust. Product Overview

FEATURES. Vacuum Motor. Moving Ahead With Technology

AZN ATEX INSTALLATION AND MAINTENANCE

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

Selecting the Correct Fan

MCV - MCH - MCHZ Multistage pumps

Horizontal Split Case Pumps Type U

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Axial flow fan AXICO ANTI-STALL

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Fans: Features and Analysis

CR A-F-A-E-HQQE 3x400/ HZ

TECHNICAL. Series 18. Pump Packages

Belt Driven Mixed Flow Fans

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

The G.P.I. Max-Air is a non-positive displacement, high volume, low pressure vacuum motor that can operate as a vacuum, compressor or blower.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Roots TM Blowers, Compressors & Controls

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

CombiBloc Close-coupled centrifugal pumps

PERTH SYDNEY MELBOURNE BRISBANE ADELAIDE NEWCASTLE DARWIN MACKAY KALGOORLIE

Full-line Product Overview

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Blowers Vacuum Pumps Compressors INNOVATION DESIGN SOLUTIONS

TP /4-A-F-A-BQQE 400D 50HZ

Roots TM Blowers, Compressors & Controls

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

dualarm Vertical In-Line Pumps

Dean Pump High Temperature Chemical Process Inline Pumps

1 of 68. Thong Fatt Jaya Machinery Hardware Sdn. Bhd. DOUBLE-STAGE LIQUID RING VACUUM PUMP. Air- Operated Double Diaphragm Pump TW Series

Ducted Propeller. Airflow Volume

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

BVG series Biogas and landfill gas applications

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Centeral Station Air Handling Unit

ENERVEX RSV CHIMNEY FAN

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

Explosion Proof Ventilation Fan Redirects Stale Air From Hazardous Location Areas

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

INSTALLATION, OPERATION & MAINTENANCE MANUAL

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

Transcription:

MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the 2014/34/EU European Directive (ATEX), for Zones 1 and 2, or, especially for US and Canada, in conformity to the requirements of Class I hazardous locations Operating principle The MCF00 centrifugal fan is made of: - an intake duct conveying the aspirated gas to the impeller inlet, which is coaxial to the shaft; - a closed impeller with axial flow inlet and radial flow exit; - a toroidal discharge volute with tangential exit. While the impeller is rotating, the vanes give a centrifugal thrust to the aspirated gas which is forced outwards into the toroidal discharge volute. The volute collects the gas delivering it to a tangential nosepiece. The compression occurs through the increment of kinetic energy given to the gas by the vanes of the impeller and the subsequent conversion of the kinetic energy into static pressure in the discharge volute. Advantages The rotating parts are not in contact with the casing during rotation. There is therefore no friction during operation and thus no internal lubrication is necessary. The gas moving through the machine therefore remains uncontaminated and completely oil-free. The other main advantages of using the MCF00 centrifugal fan are: easy installation; low noise level; no vibration; pulsation free gas flow and no surge; minimal maintenance. Features of construction To extract or compress combustible gases, such as biological gas or natural gas, the MCF 00 centrifugal fan has been designed, with a specific manufacturing technology, identified by the trademark: This technology, whose main construction features are listed below, is applied also to the fans fitted with NEMA motors in conformity to the requirements of Class I hazardous locations in the US and Canada. Only the so-called CLOSE COUPLED version (see below) is not available with NEMA motors. 2 The MCF00 centrifugal fan has been designed in order to fall within the Equipment-Group II as defined by the 2014/34/EU Directive, Category 2 both for the surrounding area conditions and for the internals of the machine. Its main construction features are the following: aluminium casted casing, impeller made of spark proof aluminium alloy with caulked vanes, bearings housing made in cast iron and aluminium casted caps, shaft in carbon steel; casing impregnated with Loctite; casing halves sealed; shaft sealing by a pair of special double-lip seals lubricated for life for speed of rotation up to 4200 rpm and by an automatic lubricator for higher rpm. The centrifugal fan is generally coupled to the electric motor via belt drive and the safety drive guard is made from spark-free material. We can also offer machines coupled to the electric motor via flexible shaft coupling and centrifugal fans manufactured in the so-called CLOSE COUPLED version (not available with NEMA motors) - i.e. a flange mounted electric motor is bolted to the fan casing and the impeller, which is dynamically balanced, is fitted directly onto the motor shaft extension. For particular duties and/or in function of the gas composition, fans with special construction features could be proposed; for example with the aluminium casted parts treated with anodic oxidation and the blades of the impeller in stainless steel; and it is also possible to fit the double-lip seals in pair on the shaft so that they are suitable for a barrier fluid in between.

MCF00 for biogas Range of duty Outlet pressure [in H2O] 70 6 60 0 9 kw - 81 db(a) at 40 800 rpm (*) for CLOSE COUPLED version 4 40 30 rpm 3 4800 rpm 30 2 20 1 10 2.4 kw(*) - 73 db(a) at 40 290 rpm 3600 rpm 4200 rpm 18 kw - 83 db(a) at 40 3.6 kw(*) - 73 db(a) at 40 0 100 200 300 400 00 600 700 800 900 1000 1100 1200 1300 1400 100 1600 1700 1800 Flow rate [cfm] The range of duty shown in the literature refers to a biogas with specific weight 0.071 lb/ft³ at 29.92 in Hg (abs) and 32 F; the suction pressure is assumed at 29.92 in Hg (abs) and the inlet temperature at 9 F. The performance curves flow rate - outlet pressure, shown in the range of duty, are given, as an indication only, at fixed rpm. On the performance curves at 3600 rpm and for the highest speed of rotation are shown, by way of information, some values of motor power and machine noise level. The motor powers shown on the curve at 3600 rpm are intended for centrifugal fans in the so-called CLOSE COUPLED version; those shown on the curve at 800 rpm are intended for fans coupled to the electric motors via belt drives. The noise level is intended as sound pressure level (SPL), measured in free field, in accordance with the Standard EN ISO 211. The most common fields of application Extraction of biogas from gasometer, natural gas from pipeline or gasometer, and burner or gas engine feeding; tank or plant gas recovery to feed torch or burner. The typical flow rate - pressure curve, rather flat at fixed rpm, and the absence of surging when decreasing the gas flow, make the centrifugal fan the ideal machine for all the applications in which the gas flow rate could vary, even considerably, in time. In short, the operating point moves, in time, by simply following the internal characteristic curve of the fan. Accessories A complete range of accessories is available, including the following: gas-tight filters; stainless steel flanged flexible connection bellows; non return valves; pressure gauges and thermometers; explosion-proof pressure switches and temperature switches; intrinsically-safe pressure and temperature transducers; manual and automatic cut-off valves; acoustic enclosures. Sales Department, in synergy with the Engineering Department, could design and quote, according to customer requirements, the machines complete with the accessories that better meet the specific needs and peculiarities of the plant. 3

Dimensions Belt drive version Dimensions in inches AUTOMATIC LUBRICATOR ONLY FOR SPEED > 4200rpm 4.0 30. 10.16 7.16 1.18 3.64 4 HOLES Ø 0.79 0.40 2.76 6.40 1.18 2.7 20.0 2.7 2.0 26.40 11.22 18.19 Inlet and outlet connections: flange, matches 10 # ANSI CLOSE COUPLED version Dimensions in inches 28.26 27.7 10.16 4.40 0.1 4 HOLES Ø 0.71 1.97 1.74 1.97 1.7 8.23 1.7 8.34 19.68 11.37 1.4 28.02 26.40 9.84 18.18 9.84 Inlet and outlet connections: flange, matches 10 # ANSI 4

MCF00 CENTRIFUGAL FAN FOR AIR The MCF00 centrifugal fan can be supplied also for the compression or extraction of ambient air in hazardous locations. In such a case its construction is simplified and the casing is not gas-tight. Outlet pressure [in H2O] MCF00 blower for air Range of duty 7 70 6 60 0 4 40 3 30 2 20 1 10 2.4 kw(*) - 73 db(a) at 40 9 kw - 81 db(a) at 40 290 rpm 4200 rpm 3600 rpm 4800 rpm 30 rpm 800 rpm 3.6 kw(*) - 73 db(a) at 40 (*) for CLOSE COUPLED version 18 kw - 83 db(a) at 40 0 100 200 300 400 00 600 700 800 900 1000 1100 1200 1300 1400 100 1600 1700 1800 The performance curves refer to air at the suction conditions of 68 F and 29.92 inhg (abs). Flow rate [cfm] MCF00 exhauster for air Range of duty Inlet vacuum [in H2O] 6 60 0 9 kw - 81 db(a) at 40 800 rpm (*) for CLOSE COUPLED version 4 30 rpm 40 3 4800 rpm 30 4200 rpm 2 20 1 2.4 kw(*) - 73 db(a) at 40 3600 rpm 18 kw - 83 db(a) at 40 10 290 rpm 3.6 kw(*) - 73 db(a) at 40 0 100 200 300 400 00 600 700 800 900 1000 1100 1200 1300 1400 100 1600 1700 1800 The performance curves refer to air at 68 F and at the suction pressure. The atmospheric backpressure is considered at 29.92 inhg (abs). Flow rate [cfm]

"Vesuvio" Factory: Regenerative blowers and exhausters Cinisello Warehouse: Goods dispatch "Fermi" Factory: Centrifugal fans and Rotary compressors Other products Sliding vane rotary compressors and vacuum pumps for air and gases Regenerative blowers and exhausters for air and gases In the logic of continuous improvement, this catalogue is subject to revision. Please contact our Sales Department for information on the version in force. INTERNATIONAL SpA Macchine Pneumatiche Rotative Via Vesuvio, 2 20834 NOVA MILANESE (MB) - Italy Tel. +39 0362 36636 Fax +39 0362 40342 www.maproint.com E-mail: mapro@maproint.com COD. 0114 - MCF 10-16 US