The PURO Condensate Cleaner Installation instructions. Maintenance instructions:

Similar documents
The PURO GRAND Condensate Cleaner Installation instructions: Maintenance instructions:

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES.

ENGLISH. Installation & Maintenance Instructions

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

Installation & Maintenance Instructions SEPREMIUM 350. Oil /water separator 05/09

Operating Instruction. Condensate separator CC 35

the condensate management specialist PURO-CT Sustainable Condensate Management CONDENSATE SEPARATORS

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

EV-PRO CONDENSATE SEPARATORS

IMI Cornelius Automated Beverage System (ABS)

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

DESIGNER HOOD MODEL: EH-E9122ST(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

Packing Instructions Heraeus Primo R

UV Lamp and Quartz Sleeve Replacement/Maintenance

Instruction Sheet DANGER

Instruction Sheet DANGER

Operating Manual Oil Water Separator CSD3 - CSD160 Version: 12/2013/DE

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Floormate Deluxe Let s get started

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

Series 57 WATER/OIL SEPARATORS

RCM-C Vinyl Cleaner. Part List: Operation conditions:

OWNER S MANUAL. Power Injection gun (PIG) "Universal" (with water connection)

PRO 2000i LOW LEVEL DEPOSITOR

Manual Parts Washer. Operating Instructions & Warranty Information

LYOTRAP FREEZE-DRYING MACHINE OPERATING INSTRUCTIONS

OPERATOR'S MANUAL HD-400

AllClear G2 Series Pressurized Filters Product Manual

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

CHH30 Dishwasher. Wiring Diagram. Spare Parts List. Installation / Operation

Operation and Maintenance Manual

DEHUMIDIFIER INSTRUCTION MANUAL

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

FEI Nova 200 Dual Beam system maintenance

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Hot Chocolate Dispenser

OWNER S MANUAL. ProDeluxe WARMERS 2028 Series-Single Water Vessel Warmers. Pump Unit 2028B (120V) 2228B (230V)

Hisense Refrigerator

INSTALLATION INSTRUCTIONS

COOKWORKS TWIN PROFESSIONAL FRYER INSTRUCTION MANUAL

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

Clean grill Daily GR 1 D1

1-866-PENNERS

DAILY REFERENCE GUIDE

K-Star International Group Inc. K-Star Electronic Appliance Inc. Toll Free:(800)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

PIPE LINE DEHYDRATOR FOR NATURAL GAS PLD thru PLD WARNING

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Pocket Hardmount. Preventative Maintenance.

FD Heavy Duty Feeder for FD 280 Tabbing System

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

64 Beverage dispensing

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE BOOKLET PROGRAMME CHART

Air treatment solutions. Aftercoolers & condensate treatment

Operating Instructions

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

USERS, INSTALLATION AND SERVICING INSTRUCTIONS

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Thank you for choosing AMI FRY. We hope you enjoy the convenience, quality and affordability of your new unit.

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Rota- Spray Instructions (Mega Part & )

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

Air Conditioner. user installation & manual manual. imagine the possibilities

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

CNG. PSB Industries. NG Series -- Natural Gas Dryers

Owner s Manual STOVES. MODELS 620 Kitchenaire. 621 Kitchenaire 711S

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

Cooker Hood Instruction Manual

Installation guide PRO7-VAQ E. Before installing read this guide first

Contents SYSTEMS CHEMICAL SELECTION CHART HOW IT WORKS ACCESSORIES RECOMMENDED INJECTORS

MOULD WITH ENTERING PUNCHES

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

PrimePour TM Operation Manual

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Couverture B80 oneway seb.qxd:couverture B80 oneway seb.qxd. USA: CANADA :

HOT & COLD WATER PURIFIER CLIMA MESA / PISO

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Cooker Hood Instruction Manual

Installation and Care Guide Dual Flush Two-Piece Toilet

WELCOME IMPORTANT SAFEGUARDS

G-36G and G-53G Glutaraldehyde Enclosure Assembly and Installation Instructions

Regulations - guidance

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING


OPERATOR'S MANUAL CD 400 / CD 500

Operating Manual for Profident / Profident PLUS

A. Set-Up with gravel

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

Transcription:

The PURO Condensate Cleaner Installation instructions The PURO condensate cleaner has been specially developed to separate oil from condensate extracted from compressed air systems and is effective with all types and makes of compressors, oils and drain valves. To obtain the best performance from the machines, we suggest the following: Installation instructions: 1) The unit is designed to easily fit against a wall. Position the machine with the TEST to the front. Connect the TEST valve and outlet nipple on the marked location (see labels). 2) After ensuring that no harmful pressure exists, connect the condensate inlet pipe(s) using one or both 1/2" " inlet connections as required. If only one connection is used, the other can be sealed with a screwed plug. Do not over-tighten connections. 3) Connect the 1/2" outlet connection to a suitable sewage drain. Do not over-tighten connections. 4) Lift the poly-element from vessel (1) and place it to one side for the time being. 5) Remove the plastic packing material from the activated carbon element and slide it back in to the vessel (2) and let it rest on the bottom of the vessel. Place lid 2 on vessel 2. 6) Remove the depressuriser foam pad, pour clean water into the depressuriser box until it flows from the outlet pipe and then replace the foam pad into the depressurising box. 7) With the cable-tied end upwards, replace the white poly-element into vessel (1) by slowly pushing the element down into vessel 1 (the poly-element should rest on the bottom of vessel 1. 8) Place lid 1 on vessel 1. 9) Your condensate cleaner is now ready for use. Note: During initial filling, dust may rise from the carbon elements; this is only displaced air and is entirely harmless. We recommend the active carbon element to be pre-soaked for 24 hrs. Any carbon dust in the outlet water is harmless. We recommend that initially a daily check is made on the quality of the output from your condensate cleaner. After a day or so, the output should be clear when viewed in a clear glass container. We recommend that you use our protection clothing kit when installing and or servicing the condensate cleaner. Maintenance instructions: Used elements can be heavy and we strongly advise that normal precautions for the lifting of heavy weights are taken. To replace the poly-element, remove the lid from the top of the vessel (1) and lift the used poly-element out of the vessel. Simply lower the new poly-element slowly into the vessel (1) and let it rest on the bottom of vessel 1. To replace the carbon elements, remove a carbon element from its vessel (2) after removing the lid, lift the used carbon element from the vessel and place where the draining water will cause no harm. Slide the new carbon element into the vessel (2) until it rests on the bottom of the vessel. The top of the carbon element should be below the outlet hole. If required, clean water can be poured onto the top of the carbon element to prevent dust. All used elements must be properly disposed of in accordance with current regulations for the disposal of hazardous waste in your area.

Tower 2 Active Coal 2 x Condensate inlets Tower 1 Poly-element Water level inside the PURO when in operation = Condensate Outlet on the rear PURO frontview TEST valve for sample taking Outlet 2 x Condensate inlets PURO topview Tower 2 Active Coal Testvalve Depressurising chamber Tower 1 Poly-element

Quick Installation Instructions Unpack the unit Screw the TEST valve and outlet nipple into the marked locations (see test label and outlet label) Remove the carbon element Unwrap the carbon element Replace the carbon element Remove the poly element Connect the inlets Connect the outlet

Connect the outlet to a suitable sewage point close to the PURO Replace the lid on the carbon tower Make sure the TEST valve is closed (turn to the right to close) Remove the foam padding Fill the unit with clean water Fill the unit until the outlet point And replace the foam padding Replace the lid (1) back onto vessel 1. Replace the poly element and slowly push it down untill it rests on the bottom of vessel 1 Your machine is ready for operation now!

DATE DESCRIPTION Service Chart: NAME/SIGNATURE REMARK