Electronic Temperature Controller 70304,

Similar documents
Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

VC-1, VC-1-SL, VC-2-L, VC-2-SL

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Universal controller for panel mounting Models CS6S, CS6H, CS6L

R1000 / R1040 / R1080

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Ultra Low Gas Cooler Series EC EC30 and EC-30/FD

SCHMIDT LED Measured Value Display MD Instructions for Use

I/A Series 716C 1/16 DIN Temperature Controller

Copyright LIQUIDYN GmbH 08/2013 Version

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

Temperature-Relay TR210

English. Operating manual. Safety temperature limiter STL50 Approved in accordance with: DIN EN (replacing DIN 3440) SIL 2

02/11/2015

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

02/11/2015

WIO200 Water In Oil measuring instrument

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Software Version 2.01 LEVEL MONITOR MODEL 220

Operating Manual TR600

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

PCR-300 PCR-300 RC. Installation and Operating Instructions

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

EC2-5x2 Series Condensing Unit Controllers

UDC100 Universal Digital Controller Specifications

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

ST Wiring diagram. Product description. Four-stage controller. Order number

Universal Input Digital Panel Meter With Bargraph, NA3

DOCUMENTATION IPS640

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

GMH 285 / GMH 285-BNC

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

ST Wiring diagram. Product description. Standard temperature controller. Order number

Process Alarm Module RTA 421

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Process & TeMPerATUre UniversAl input DigiTAl MeTers

EC3-X33 Stand-alone Superheat Controller Technical Data

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

TEMPERATURE CONTROLLER (STANDARD MODEL)

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Temperature Controllers

99 Washington Street Melrose, MA Phone Toll Free Visit us at

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

DOCUMENTATION IPS640

Waste water ejection unit

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Original operating instructions Safety switch with guard locking AC901S AC902S

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Instructions for the fan motor control system, SILVER C

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

EC Ultra Low Gas Cooler EC-30C Instruction Manual Version Software Version 1.00

UDC 700 Universal Digital Controllers and Indicator Specifications

Technical Description Relay Module Flame Detector

Nov 08 PRODUCT SPECIFICATION SHEET

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Oxygen (O2) Single-Point Gas Detection System

Vacuum Controller with Control Unit VC 900

FCR 05, FCR 07. Power factor correction controller. User and service manual

CM 8. Temperature controllers with compact dimensions. Manual 42/61-71 EN Rev. 01

Model 96VTR ¼ DIN Process Controller

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Table of Contents SECTION PAGE

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

CM 16. Temperature controllers with compact dimensions. Manual 42/61-72 EN Rev. 01

TDF 15 MICROPROCESSOR-BASED DIGITAL ELECTRONIC THERMOCONTROLLER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

Series: MBC1-TC Mini Benchtop Temperature Controller

ACS-30-EU-EMDR- 10-MOD

eed quality electronic design USER s MANUAL

TC515 and TC600 Installation Manual. a Winters company

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Series Temperature Controller Instruction Sheet

Electrically Heated Sample Lines Type 3/4/5-N/M/H (Ex), PSP 4M(-W), Type 3/4/5-5/30/50/80/100/120 (Ex)

Transcription:

Electronic Temperature Controller 70304, 70304.2 Instruction Manual Version 1.00.01

List of content 1 General information... 4 2 Declaration of conformity... 4 3 Safety instructions... 5 4 Warranty... 5 5 Used terms and signal indications... 6 6 Introduction... 7 7 Receipt of goods and storage... 7 8 Description... 8 9 Dimensions and installation... 9 10 Technical Data... 11 11 Electrical connection... 11 11.1 Replacing controller 703 by controller 70304... 12 12 Operating principle... 13 12.1 Parameter of the user level with factory setting... 13 13 Change of parameters... 14 13.1 Removing and activating the level inhibit... 14 13.2 Menue structure... 15 13.3 Time Out... 16 14 Change of the setpoint... 16 15 Comissioning... 16 15.1 Entry and check of controller parameters... 16 15.2 Self-optimising (PID action) of control circuit... 17 15.3 Commissioning with heated foreign components... 18 16 Low temperature alarm and excess temperature limitation... 18 16.1 Restarting after excess or low temperature alarm... 18 17 70304 or 70304.2 with ma-output... 19 17.1 Adjusting Signal type and temperature range... 19 18 Decommissioning... 19 19 Maintenance... 20 20 Spare part list... 20 21 Appendix... 20 List of Illustrations Figure 1 Display/control elements... 8 Figure 2 Mounting cutout for controller 70304 for front panel mounting... 9 Figure 3 Housing and mounting dimensions for controller 70304 for front panel mounting... 9 Figure 4 Housing and mounting dimensions for controller 70304.2 for rail mounting... 10 Figure 6 Menue structure... 15 2 Temperature controller 70304 1.00.01 www.mc-techgroup.com

Dear customer, we have made up this operating manual in such a way that all necessary information about the product can be found and understood quickly and easily. Should you still have any question, please do not hesitate to contact M&C directly or go through your appointed dealer. Respective contact addresses are to be found in the annexe to this operating manual. Please also contact our homepage www.mc-techgroup.com for further information about our products. There, you can read or download the data sheets and operating manuals of all M&C products as well as further information in German, English and French. This Operating Manual does not claim completeness and may be subject to technical modifications. 04/2016 M&C TechGroup Germany GmbH. Reproduction of this document or its content is not allowed without permission from M&C. Version: 1.00.01 www.mc-techgroup.com Temperature controller 70304 1.00.01 3

Head Office M&C TechGroup Germany GmbH Rehhecke 79 40885 Ratingen Germany Telephone: 02102 / 935-0 Fax: 02102 / 935-111 E - mail: info@mc-techgroup.com www.mc-techgroup.com 1 GENERAL INFORMATION The product described in this operating manual has been examined before delivery and left our works in perfect condition related to safety regulations. In order to keep this condition and to guarantee a safe operation, it is important to heed the notes and prescriptions made in this operating manual. Furthermore, attention must be paid to appropriate transportation, correct storage, as well as professional installation and maintenance work. All necessary information a skilled staff will need for appropriate use of this product are given in this operating manual. 2 DECLARATION OF CONFORMITY CE - Certification The product described in this operating manual complies with the following EU directives: EMV-Instruction The requirements of the EU directive 2014/30/EU Electromagnetic compatibility are met. Low Voltage Directive The requirement of the EU directive 2014/35/EU Low Voltage Directive are met. The compliance with this EU directive has been examined according to DIN EN 61010. Declaration of conformity The EU Declaration of conformity can be downloaded from the M&C homepage or directly requested from M&C. 4 Temperature controller 70304 1.00.01 www.mc-techgroup.com

3 SAFETY INSTRUCTIONS Please take care of the following basic safety procedures when mounting, starting up or operating this equipment: Read this operating manual before starting up and use of the equipment. The information and warnings given in this operating manual must be heeded. Any work on electrical equipment is only to be carried out by trained specialists as per the regulations currently in force. Attention must be paid to the requirements of VDE 0100 (IEC 364) when setting high-power electrical units with nominal voltages of up to 1000 V, together with the associated standards and stipulations. Check the details on the type plate to ensure that the equipment is connected to the correct mains voltage. Protection against touching dangerously high electrical voltages: Before opening the equipment, it must be switched off and hold no voltages. This also applies to any external control circuits that are connected. The device is only to be used within the permitted range of temperatures and pressures. Check that the location is weather-protected. It should not be subject to either direct rain or moisture. The temperature controllers 70304 and 70304.2 must not be used in hazardous areas. Installation, maintenance, monitoring and any repairs may only be done by authorized personnel with respect to the relevant stipulations. 4 WARRANTY If the equipment fails, please contact M&C directly or else go through your M&C authorised dealer. We offer a one year warranty as of the day of delivery as per our normal terms and conditions of sale, and assuming technically correct operation of the unit. Consumables are hereby excluded. The terms of the warranty cover repair at the factory at no cost or the replacement at no cost of the equipment free ex user location. Reshipments must be send in a sufficient and proper protective packaging. www.mc-techgroup.com Temperature controller 70304 1.00.01 5

5 USED TERMS AND SIGNAL INDICATIONS D ANGER! W A R N I N G! C ARE! This means that death, severe physical injuries and/or important material damages will occur in case the respective safety measures are not fulfilled. This means that death, severe physical injuries and/or important material damages may occur in case the respective safety measures are not fulfilled. This means that minor physical injuries may occur in case the respective safety measures are not fulfilled. C A R E! A T T E N T I O N! Without the warning triangle means that a material damage may occur in case the respective safety measures are not met. This means that an unintentional situation or an unintentional status may occur in case the respective note is not respected. NOTE! These are important information about the product or parts of the operating manual which require user s attention. SKILLED STAFF These are persons with necessary qualification who are familiar with installation, use and maintenance of the product. 6 Temperature controller 70304 1.00.01 www.mc-techgroup.com

6 INTRODUCTION The compact microprocessor contolled temperature controllers type 70304 and 70304.2 are mainly used for M&C components that have no temperature controller in their standard specification. If the temperature controller is ordered together with an M&C component, he already is parameterized and preprogrammed. Additionally to the controllers in dependance on the M&C device a relais with sufficient switching capacity is necessary. The controllers have an adjustable sensor input for all common temperature sensors and they can be used as an programmable two or three step or continious and self-optimizing controller with PID structure. 7 RECEIPT OF GOODS AND STORAGE The temperature controllers 70304 and 70304.2 are complete pre-installed units. Please take the temperature controller and possible special accessories carefully out of the packaging material immediately after arrival, and compare the goods with the items listed on the delivery note! Check the goods for any damage caused during delivery and, if necessary, notify your transport insurance company without delay of any damage discovered! NO TE! The equipment should be stored in a protected, frost-free room! www.mc-techgroup.com Temperature controller 70304 1.00.01 7

8 DESCRIPTION The controller type 70304 is provided for front panel mounting and the controller type 70304.2 is provided for rail mounting. (1) Actual value display red, 10mm high, 4 digits (2) Active Setpoint Factory setting SP1 (3) Setpoint Four digit, green; decimal place is configurable; Also used for operator prompting (display of parameter and level symbols) (4) -key in order to select parameters in order to change values in order to change values Exit-key in order to leave the levels (5) Indication yellow for - Switch status of binaryoutputs 1 6 (display lights up = on) - ramp/programm function is active - manual operation is active (6) 16-segment display for the unit C / F factory setting C Figure 1 Display/control elements 8 Temperature controller 70304 1.00.01 www.mc-techgroup.com

9 DIMENSIONS AND INSTALLATION 45 +0,6 0 45 +0,6 0 Figure 2 Mounting cutout for controller 70304 for front panel mounting 48 51 48 44,5 EXIT 90 105 Figure 3 Housing and mounting dimensions for controller 70304 for front panel mounting www.mc-techgroup.com Temperature controller 70304 1.00.01 9

110 2/2 2/3 2/4 2/6 2/8 3/7 3/8 55 37,5 122 75 61,25 EXIT 5,75 3/5 3/4 4,5 1/7 1/6 N 3/2 L 3/1 Figure 4 Housing and mounting dimensions for controller 70304.2 for rail mounting 10 Temperature controller 70304 1.00.01 www.mc-techgroup.com

10 TECHNICAL DATA Temperatue controller type 70304 70304.2 Part No. 01B8401 01B8456 Temperature sensor Logic output Switching capacity solid state relais Control mode Resistance thermometer, thermocouple 0 / 12V DC, max. 30mA to an external solid state relay external PID Status alarm High temperature limiter with continious cutoff, low temperature alarm: 1 contact NO each, potential free, contact rating 250V AC, 3A Indicators Temperatures Climatic conditions Measuring temperature: 4 digits 7 Seg LED red 10 mm; setting value: as listed before but 7.0 mm; ON operation, ramp function on, 2 alarms Ambient 0-55 C; storage -30 to +70 C < 90% r.h., dew not allowed Electrical connections Terminals 1,5 mm 2 Power supply Housing material 110-240V +10/-15% 48-63 Hz, 8VA Synthetic material Housing version Front panel mounting Rail mounting Weight / Protection Optional: Controller with maoutlet for actual value 200 g / terminals IP20, housing IP 20, front plate IP 65 EN60529 01B8411 Ambient 0-50 C; storage -30 to +70 C 320g / IP20 EN60529 01B8457 11 ELECTRICAL CONNECTION W A R N I N G! An incorrect system voltage can damage the unit. When establishing electrical connection, ensure that the system voltage corresponds to the voltage specified on the rating plate! NO TE! For the erection of power installations with rated voltages up to 1000V, the requirements of VDE 0100 and relevant standards and specifications must be observed! The supply circuit of the unit must be provided with a fuse of 16AT (overcurrent protection); the electrical values are shown in the technical data. www.mc-techgroup.com Temperature controller 70304 1.00.01 11

The electrical connection of the controller 70304 takes place at the terminals on the rear side of the housing and for the controller 70304.2 at the terminals of the sidewalls. Wiring plan controller 70304 and 70304.2 Connector block / terminal Function 3/1 Mains L AC 110-240V 3/2 Mains N 50/60Hz 8VA Indication in the display at normal operation 3/7 Alarm 2 3/8 High temperature limiter with continious cutoff 3A 250VAC resistive load Opens exceeding the actual value by + 10 C 2 (closed) 3/4 Alarm 1 3/5 Low temperature 3A 250VAC resistive load Closes reaching the set value 10 C 1 (closed) 2/6 Triggering + 12V 30mA 2/8 Solid State Relais 0V 3 (triggered) 2/2 + Thermo couple PT100 two wire 2/3 Connection sensor - Thermo couple 2/4 PT100 two wire For controller with ma-output (optional): Connector block / Function terminal 1/6 ma output + 1/7 ma output - 11.1 REPLACING CONTROLLER 703 BY CONTROLLER 70304 Terminals old controller 703 Terminals new controller 70304 L1 3/1 N 3/2 242 3/7 243 3/8 142 3/4 143 3/5 81 2/6 80 2/8 111 2/2 112 2/3 113 2/4 12 Temperature controller 70304 1.00.01 www.mc-techgroup.com

12 OPERATING PRINCIPLE Operating and programming of the controller takes place on two levels. On the first level for normal operation, alarms can be resetted or in case of startup a control circuit, self-optimising is activated. Underneath there is the user level. All important adjustments of the controller are combined on the user level and can be changed after removing the level inhibit. 12.1 PARAMETER OF THE USER LEVEL WITH FACTORY SETTING Setpoint SP, factory setting = 180 C Max. excess temperature difference to the setpoint ALSE, factory setting = 10 C. In case of exceeding, a cutoff of the controller with lock and an alarm signal takes place. Max. low temperature difference to the setpoint Lo-t, factory setting = 10 C. In case of falling below, an alarm signal takes place Limit comparator Lfun, factory setting = 2 : for controller with ramp function, 6 : for controller without ramp function, other values are not adequate for the operation of M&C products Function of the controller Fnct, factory setting = 1: ramp function, 0 : fixed-setpoint controller. Other values are not adequate for the operation of M&C products. Ramp slope resp. increase of temperature in C/min ( F/min) rasl, factory setting = 30 Sensor type SenS, factory setting = 2: Resistance thermometer in 2-wire circuit 0: no function 1: Resistance thermometer in 3-wire circuit 2: Resistance thermometer in 2-wire circuit 3: Resistance thermometer in 4-wire circuit 4: Thermocouple 5: resistance transmitter 6: Heater current 0 50mA AC (analog input 2 only) 7: 0 20mA 8: 4... 20mA 9: 0 10V 10: 2 10V 11: 0... 1V www.mc-techgroup.com Temperature controller 70304 1.00.01 13

Linearization Lin, factory setting = 1, Pt100 0: Linear 1: Pt100 2: Pt500 3: Pt1000 4: KTY11-6 5: W5Re_W26Re C 6: W3Re_W25Re D 7: NiCr-CuNi E 8: Cu-CuNi T 9: Fe-CuNi J 10: Cu-CuNi U 11: Fe-CuNi L 12: NiCr-Ni K 13: Pt10Rh-Pt S 14: Pt13Rh-Pt R 15: Pt30Rh-Pt6Rh B 16: NiCrSi-NiSi N 17: W3Re_W26Re 18: customized linearization 13 CHANGE OF PARAMETERS To change parameters the level inhibit on the user level has to be removed. 13.1 REMOVING AND ACTIVATING THE LEVEL INHIBIT To remove the level inhibit, act as follows: Standard display (below setpoint, up actual value ) has to be visible Press key and simultaneously for 5sec., display = Code 3 (all levels are locked) Press Change value from 3 to 2 with key The value is blinking after 2sec. and the change is taken over The user level is unlocked now Press EXIT To activate the level inhibit, act as follows: Standard display (below setpoint, up actual value ) has to be visible Press key and simultaneously for 5sec., display = Code 2 (all levels are locked) Press Change value from 2 to 3 with key The value is blinking after 2sec. and the change is taken over The user level is locked now Press EXIT 14 Temperature controller 70304 1.00.01 www.mc-techgroup.com

Changing parameters with or Takeover of changed values after 2 sec. 13.2 MENUE STRUCTURE Generally: Changing to the user level with -key (display = User) To choose the first parameter press -key again (display = SP) Changing to the next parameter with -key Back to the standard display press EXIT-key (2x) SP = Setpoint ALSE = Excess temperature with lock Lo-t = Low temperature alarm LFun = Limit comparator function Fnct = Function of controller rasl = Ramp slope SenS = Sensor type Lin = Linearization Standard display 290 300.0 Time out >2 min Exit Exit User SP ALSE Lo-t Exit LFun Fnct rasl SenS Lin Figure 5 Menue structure www.mc-techgroup.com Temperature controller 70304 1.00.01 15

13.3 TIME OUT If no operation takes place, the controller automatically returns to the standard display after about 2 minutes using any changed parameters. 14 CHANGE OF THE SETPOINT W A R N I N G! Observe the maximum temperature of the device to be controlled to avoid damaging the same. The setpoint value should not be reduced in one step by more than the entered alarm value, as the setpoint value will be outside the set alarm window. This will result in the generation of an overtemperature alarm, which will permanently deactivate the heating circuit. For restart: Let cool down the device below the new setpoint; Press EXIT and -key or Reset of the low temperature alarm by switching of and on of the mains voltage. 15 COMISSIONING 15.1 ENTRY AND CHECK OF CONTROLLER PARAMETERS For the entry and check of controller parameters, the heating of the respective M&C component must not yet be connected. NO TE! W A R N I N G! In any event prior to commissioning, the parameters SP (setpoint), SenS (sensor type) and Lin (linearization depending on the particular M&C unit must be entered. The remaining parameters should correspond with the factory setting. If the heating should already by connected, isolate the unit from the supply before disconnecting the heating! 16 Temperature controller 70304 1.00.01 www.mc-techgroup.com

15.2 SELF-OPTIMISING (PID ACTION) OF CONTROL CIRCUIT The controllers type 70304 and 70304.2 include the option of self-optimising. For the initial operation of all M&C components, this is necessary. NO TE! For self-optimising of the control circuit, the heating of the respective M&C component must be reconnected to the appropriate controller terminals. W A R N I N G! Before connecting the heating, isolate the unit from the supply! Before self-optimizing firstly the ramp function has to be deactivated (Fnct = 0) and the parameter for the limit comparator has to be changed (Lfun = 6). See also chapter 13. The self-optimising function can be activated as follows: After cable connection, switch on the supply. When the actual value (top display, red indicator) reaches the setpoint value (bottom display, green indicator), press + keys simultaneously for longer than 2 seconds. The word tune now flashes in the setpoint value display and the selfoptimising function is activated. Self-optimization has finished when the display changes to the standard display. The time of selfoptimizing depends on the control circuit. To cancel the self-optimization press the keys + simultaneously. After self-optimization reactivate the ramp function (Fnct = 1) and reset the parameter for the limit comparator (Lfun = 2). www.mc-techgroup.com Temperature controller 70304 1.00.01 17

15.3 COMMISSIONING WITH HEATED FOREIGN COMPONENTS Commissioning takes place as described in chapters 16.1 and 16.2. The parameters for SP, ALSE, Lo-t, Lfun, Fnct, rasl, SenS and Lin must be entered for the respective component (see chapter 12 and 13). The parameter rasl must be determined. For this purpose the time for heating the unit until the setpoint temperature is reached must be measured. This is then followed by (empirical value): rasl = 0.8 (setpoint temperature/rate of temperature rise) The calculated rasl value must be entered rounded. After entering the parameters a self optimization, described in chapter 15.2, has to be operated. 16 LOW TEMPERATURE ALARM AND EXCESS TEMPERATURE LIMITATION The controllers type 70304 and 70304.2 are adjusted and wired so that it uses relay 2 as an low temperature alarm output and relay 1 as an excess temperature limitation with permanent deactivation. Both alarms are indicated on the controller front panel by the respective number (1 or 2) extinguishing. This takes place if the setpoint temperature is higher or lower than 10 C. Operating state 1 2 3 Heating up off on on/off Normal heating on on on on heating off on on off Alarm X off X 16.1 RESTARTING AFTER EXCESS OR LOW TEMPERATURE ALARM In order to restart the unit after a temperature alarm with permanent deactivation, the cause of the alarm must initially be remedied. With not programmed ramp functions, an alarm reset must take place as follows: Press EXIT and keys simultaneously or Switch off and on the mains voltage. With programmed ramp functions, an alarm reset must take place as follows: If the actual value is <±10 C to the setpoint press EXIT and keys simultaneously or Switch off and on the mains voltage. In case of an alarm reset by switching off and on the mains voltage the ramp start value is equivalent to the actual value. 18 Temperature controller 70304 1.00.01 www.mc-techgroup.com

17 70304 OR 70304.2 WITH ma-output The controllers 70304 and 70304.2 are also available with a ma-output. This output is also configurable. The output signal and the temperature range are adjustable. 17.1 ADJUSTING SIGNAL TYPE AND TEMPERATURE RANGE To adjust the signal type and temperature range: -key, USEr, up to Conf, -key, up to OutP, -key, up to OutA, -key, Out6, -key, Fnct, SiGn, -key, SiGn blinking, with or choose signal type: 0 = 0-10V 1 = 2-10V 2 = 0-20mA 3 = 4-20mA (factory setting) Takeover of the adjusted value takes place after 2sec. up to 0Pnt (zero point of the temperature range): -key, 0Pnt blinking, with or adjust zero point (0,0 = factory setting). up to End (end point of the temperature range): -key, End blinking, with or adjust end point (200,0 = factory setting). 18 DECOMMISSIONING NO TE! The place of installation of the temperature controller must be protected from frost also in the time in which the unit is deactivated. No particular measures are necessary for brief decommissioning of the temperature controller. www.mc-techgroup.com Temperature controller 70304 1.00.01 19

19 MAINTENANCE Before carrying out maintenance work, the system and process-specific safety measures must be observed! W A R N I N G! High voltage. Before opening the housing, isolate the temperature controller from the supply! The temperature controller does not require any special maintenance. The temperature controller should be cleaned with compressed air from time to time depending on the degree of pollution of the ambient air. 20 SPARE PART LIST Temperature controller 70304 and 70304.2 (C) Consumable parts, (R) Recommended spare parts, (S) Spare parts 01B8401 Electronic PID temperature controller type 70304 with self-optimising function, front-mounting enclosure, sensor input: resistance thermometer or thermocouple, output: 0 / 12V for Solid-State relay control Status signal output: 1 contact NO for excess and low temperature alarm, Alarm relay switching capacity: 250VAC, 3A Dimensions: 48x48x100 Power supply: 230/115V, 50/60Hz EZR0013 Relais for controller 70304, 230VAC T EZR0010 Relais for controller 70304, 110VAC T Recommended quantity being in operation [years] V/E/T 1 2 3 T 21 APPENDIX For further product documentation, please see our internet catalogue: www.mc-techgroup.com 20 Temperature controller 70304 1.00.01 www.mc-techgroup.com