Handrail Lighting System

Similar documents
ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

LED RETROFIT CONVERSION KITS

Innovative Lighting R-Series Overhead LED Conversion Kits

Honeywell Durafit LED Retrofit Kit

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

SERVICE BY QUALIFIED PERSONNEL ONLY

Innovative Lighting R-Series Vertical Refrigeration

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

SYSTEM FIELD CUTTABLE SERIES

EFFICIENT LONG LIFE & ENERGY SERIES

Control Panel 2.0 Installation Guide

BAS SFP22 Edge-lit LED Panel

SYSTEM. field cuttable. lipleds 8200 Series

Oxygen (O2) Single-Point Gas Detection System

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Lamp: K K K K K K

LED RETROFIT SOLUTIONS

Lamp: K K K K K K

SOLID STATE ILLUMINATED RAIL

Safety Evaluation of Luminaires and Self Ballasted Lamps. 1

Modular & linear architectural lighting for residential and commercial environments.

PRELIMINARY PRODUCT CODE TYPE LOCATION DRIVER OPTICS LENGTH WATTAGE COLOR TEMP CABLE 3 + MOUNTING. Wall Grazer. Flood 32ºx85º K E End

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Lamp: Average Lamp Life: 50,000 hours. 24VDC Power Supply (sold separately): PSB-4X96W VDC VAC input, 4x96 watt output

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Bdl60u Fluorescent Emergency Ballast

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

SECTION INTERIOR LIGHTING

Video Surveillance Remote Devices and Sensors

LED RETROFIT CONVERSION KITS

S R 8 Circular LED Engine Product Specification

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

SYSTEM. field cuttable LLED8000

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Product Specifications MaxLumen MRI LED Diffused Lighting

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Cold Door 2 LED Retrofit Kit Lighting System

Architectural Specification Sheet

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

New Linear Series DISCONTINUED

Emergency Lighting. Product Guide LED. The right source for the. right light

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

MONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.

RELEASE DEVICE CONTROLS

High Lux Performance White LED MR16 Lamp

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

CONTENTS AUTOMATIC TRANSFER SWITCHES

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FET22 (2x2) 25W & 40W Series

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

PART 1 GENERAL 1.01 SUMMARY

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Grüv Flare Regressed. Recessed Linear LED

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Q7800H Integrated Burner Control Subpanel

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Product Specifications MaxLumen MRI LED Diffused Lighting

MANUAL RESET ALARM RELEASE BOX

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

M100 LED Direct/Indirect

OPTICAL TURNSTILE SYSTEM

Grüv Flare Regressed. Recessed Linear LED

AL100 AL150 AL300 AL400 AL500 AL550 AL700 AL750 AL800 AL850 TIKI PL100 PL200 PL250 BL50 BL110 BL200 BL300 HL100 HL200 DL50 DL100 DL200 SL65-LED

LHBXD LED Linear High Bay

FPLHB - Fidelux Premier Linear Highbay

M60 LED Recessed Wet Location

Product Specifications MaxLumen MRI LED Diffused Lighting

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

LED Reliability and Current Standards for Measurement

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

LED Linear Design Highlights

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

Recessed LED Wall/Slot SAE 202

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

LED IMPORTANT SAFETY INSTRUCTIONS

irail PRODUCT: IRAIL INFILL: CABLE GRANDSCAPE BOARDWALK THE COLONY, TX

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Transcription:

PRODUCT SUMMARY PRODUCT FEATURES Three beam spread options Four Kelvin temperatures Energy efficient 50,000 hour LED life Stable & consistent color temperature Low voltage Easy to assemble & install Cool to the touch Compatible with C.R Laurence Cap Rail models: GR16 (diameter: 1.66, 42.2mm), GR20 (2, 50.8mm), GR25 (2.5, 63.5mm), GR30 (3, 76.2mm), GR35 (3.5, 88.9mm), and GR40 (4, 101.6mm) C.R Laurence can provide custom hardware solutions Meets A.D.A requirements for handrail diameters Suitable for wet locations Color Temperatures & Light Output 3000K (211 lumens*/foot) 3500K (211 lumens*/foot) 4000K (211 lumens*/foot) 6500K (211 lumens*/foot) Other colors and lower lumen outputs are available (*Lumen data based on actual light output of luminaire, not the higher output of the raw LEDs. Measured with 60 asymmetrical lens.) Beam Spread Options 60 Asymmetrical 65 Symmetrical 110 Symmetrical CRI Output 3000K (CRI 80+) 3500K (CRI 80+) 4000K (CRI 80+) 6500K (CRI 80+) LED Light Engine Standard Length: 12 (304.8mm) Field cuttable in 4 (101.6mm) increments Run lengths of 10 (3.05m) possible Straight lengths only Power Supply Primary voltage: 120 or 120-277 universal input Secondary voltage: 24VDC 4.1 A Max Maximum illumination length of a single 100W power supply 20 (6.10m) - two 10 (3.05m) runs Power Supply Tips 20% maximum overage for breaker for primary current draw Do not plug multiple power supplies into one run All ilight power supplies should be on an independent circuit Recommend surge protection upstream from power supply Verify correct voltage prior to wiring to non-switching power supplies Low Voltage Cable Maximum distance of low voltage cable in any given run: 14 AWG: 40 feet (12.19m) 12 AWG: 60 feet (18.29m) 10 AWG: 100 feet (30.48m) Housing & Lens Standard Length: 6 (1.829m) Field cuttable to desired length ORDERING INFORMATION (includes light engine, lens, housing, power supplies & kit accessories) Class Light Color Lens Type Version HS 01 HS = Handrail Lighting System W30 = White 3000K W35 = White 3500K W40 = White 4000K W65 = White 4500K C060A = Clear, 60 Asymmetrical C065S = Clear, 65 Symmetrical C110S = Clear, 110 Symmetrical 01 = Version I Specification sheets are subject to change without notice. For the most recent version, please refer to www.ilighttech.com 1 ilight Technologies 118 South Clinton Street, Suite 370 Chicago, IL 60661 T 312.876.8630 F 312.876.8631

Specification, Bidding, Field Measurements, & Installation For a smooth, predictable process and a high quality outcome, you need: A) a high quality light source (ilight) B) A high quality hardware system (C.R. Laurence) C) An experienced electrical contractor, and D) An experienced handrail installer (e.g. ornamental ironworker, metal shop, glazing company) A bundled illuminated handrail system (lighting and hardware together) conflicts with how the trades like to do business. If an EC does not provide the lighting, they won t warrant it. And if a handrail installer does not provide the hardware, they won t warrant that. And neither trade wants to purchase material for the other trade. That s why many general contractors demand that the handrail installer provides the hardware and the electrical contractor provides the lighting. This makes ilight the ideal solution: electrical contractors and handrail installers have been working together for over 10 years to successfully install the ilight on compatible C.R Laurence handrails. Specification C.R Laurence ( CRL ) handrail hardware model compatible with ilight, including CRL Cap Rail models: GR16 (diameter:1.66, 42.2mm) GR20 (diameter: 2.0, 50.8mm) GR25 (diameter: 2.5, 63.5mm) GR30 (diameter: 3.0, 76.2mm) GR35 (diameter: 3.5, 88.9mm) GR40 (diameter: 4.0, 101.6mm) Or custom CRL hardware designed to meet the specifications of the ilight. Specification in the Metals division. Please cross reference the ilight Handrail Lighting System specification. ILight Specification in the lighting section of the Electrical division. 3000K (211 lumens*/foot) 3500K (211 lumens*/foot) 4000K (211 lumens*/foot) 6500K (211 lumens*/foot) (*Lumen data based on actual light output of luminaire, not the higher output of the raw LEDs. Measured with 60 asymmetrical lens.) Beam Spread Options 60 asymmetrical 65 symmetrical 110 symmetrical Please cross reference the handrail hardware specification. Bidding Handrail Installer bids the hardware Electrical Contractor bids the light source Field Measurements Handrail Installer Not Required Small variations from plan to actual would not significantly change costs for the ilight. ilight light engine comes in 1-foot sections, cuttable every 4 inches Housing & lens come in 6-foot sections and are field cuttable Up to 20 feet per power supply; (two 10-foot runs) Installation Handrail Installer Electrical Contractor 2 ilight Technologies 118 South Clinton Street, Suite 370 Chicago, IL 60661 T 312.876.8630 F 312.876.8631

MECHANICAL Housing Mounting 6 (1.83m) standard length field cuttable to allow for exact size of light engine boards 0.75 (19.05mm)w x 1.10 (27.94mm)h when used within handrail applications with frosted lens 0.75 (19.05mm)w x 0.90 (22.86mm)h when edge lighting glass panels Light engine jumper pins to connect one light engine board to the next Shims help hold handrail housing in position during installation Mounting clips mount into hand rail and screw into handrail housing Power Supply Dimensions Electronic (Advance) = 9.50 x 1.18 x 1.70 65 Symmetric Lens 110 Symmetric Lens 60 Asymmetric Lens 3 ilight Technologies 118 South Clinton Street, Suite 370 Chicago, IL 60661 T 312.876.8630 F 312.876.8631

LIGHTING SYSTEM PROFILE ENVIRONMENTAL ELECTRICAL Load Voltage 24 VDC Load Current 142.5 ma/foot at 24VDC (476.5mA/meter) 3.4 watts/foot (11.15 watts/meter) Maximum Run Length 20 (6.10m) - two 10 (3.05m) runs with ilight approved power supply DC Cable 14 AWG, PVC/Nylon Tape TC 600 Volt power and control able or equivalent FT-4 fire rating Class 2 wiring system Silicone based wire nuts Electrical Tips Only use ilight approved power supply Operating Temperature Range -25 C to 50 C (-13 F to 122 F) Storage Temperature Range -25 C to 75 C (-13 F to 167 F) Certification Suitable for Wet Locations Complies with UL 1598 and CSA c22.2 No. 250-00 Luminaires MetLabs listed. MetLabs is a Nationally Recognized Testing Laboratory (NRTL) Power Supplies are RU listed (Recognized Components by Underwriters Laboratory) 4 ilight Technologies 118 South Clinton Street, Suite 370 Chicago, IL 60661 T 312.876.8630 F 312.876.8631

ELECTRONIC (ADVANCE) POWER SUPPLY ACCESSORIES HARDWARE & LIGHTING SYSTEM CROSS SECTION CAP RAIL HOUSING MOUNTING CLIP T01-KIT02-01-00 JUMPER PINS T01-JMP02-01-00 LED HOUSING SHIMS T01-SPC01-01-00 POWER SUPPLIES 65-ADV100W24V Input: 120-277VAC 50/60Hz Output: 24VDC 4A max RU listed for U.S. and Canada Additional Enclosure Required 2lbs. (0.9kg) DRY DAMP 5 ilight Technologies 118 South Clinton Street, Suite 370 Chicago, IL 60661 T 312.876.8630 F 312.876.8631