Meditec M700 Series Patient Monitors

Similar documents
PM-9000 Express Portable Patient Monitor

www. szcomen. com COMEN - SHARE WITH THE WORLD

OMNI TOUCH SCREEN PATIENT MONITOR

Omni (K) PATIENT MONITOR

PATIENT MONITORING SYSTEMS

Multi-Parameter Patient Monitor

PATIENT MONITORING SYSTEMS

PATIENT MONITORING SYSTEMS

DPM Summary of Features and Benefits

1 Appendix - Product Specifications

Vitalmax 4000 CL Product Specifications

MRI Patient Monitoring System (Model )

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

Product Specifications

Menntor X7 Specification

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

SPECIFICATION FOR MULTIPARAMETER MONITOR

GE Healthcare. Dash Variable-Acuity Monitoring

User s Guide. Cardell Touch Veterinary Vital Signs Monitor. For Models:

Alarm and Measurement Default Settings

OMNI Express VS VERSATILITY IN VITAL SIGNS

SECTION L MONITORING EQUIPMENT

DPM4 Bedside Monitor Default Settings

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

CLEO VERSATILITY IN VITAL SIGNS

T1 Monitor/Module Default Settings

M8000VET /M9000VET Veterinary Monitor User s Manual

Infinity M300 Patient Worn Monitoring

L505. Patient monitor user manual. Technology that doesn t miss a beat. Tel:

Patient Monitor CM400PC Monitoring Module

Ultraview SL2400 With Wireless-LAN-Option

HeartStart XL+ Configuration Worksheet

T1 BEDSIDE MONITOR GUIDELINE

SAINT JAMES HOSPITAL GROUP PURCHASING DEPARTMENT

Measurements to guide your patient care

Instructions for Use Vista 120

Cost-effective way to tailor anesthesia

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

Central Monitor CNS Shown with options

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

Revision History WARNING

SERVICE MANUAL YM6000 Patient Monitor

BeneView T5/ BeneView T8. Patient Monitor. Operator s Manual

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

SECTION L MONITORING EQUIPMENT

Infinity M300+ Telemetry

M9500 Patient Monitor User s Manual

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

Atlas Monitor Outline Train the Trainer

Propaq LT Outline Train the Trainer

The information in this document is subject to change without notice.

General Skills. yes. Device controls, buttons, indicators, and connectors

SERVICE MANUAL. Patient Monitor M30. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Multiparameter. er Monitor DM

HBP Patient Monitor. Operator s Manual. EU representative OBELIS S.A Bd. Général Wahis, Brussels, Belgium.

QAM.L L550 series. Patient Monitor Manual QAM.L

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

PAT I E N T M O N I TO R I N G N E T W O R K

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

PM-9000Vet Veterinary Portable Multi-Parameter Patient Monitor. Operator s Manual

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

Menntor X7 SERVICE MANUAL. Modular Patient Monitors FDM

Addendum to the Instructions for Use

BeneVision Central Monitoring System. Quick Reference Guide

B40/B20 Patient Monitor User's Guide. English E (Paper) 21 November General Electric Company. All rights reserved.

INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP5 Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Central Monitor. Central Monitoring System. Intuitive, Reliable, Flexible CNS-9601K. Shown with options

CREATIVE MEDICAL. PC-3000 Multi-Parameter Monitor

BEDSIDE MONITORING Dash 3000/4000 V5

qube mini Overview

CNAP MONITOR 500 HD QUICK GUIDE. This Quick Guide DOES NOT REPLACE the user manual!

Multi-parameter Veterinary Monitor. User Manual

Multi-parameter Patient Monitor STAR8000H. User Manual

T1 Patient Monitor. Operator s Manual

Patient Alarm Messages

THE CLINICAL CONNECTION

VS2000V Veterinary Vital Signs Monitor Operation Manual

HOLTER RECORDER Product parameters

Infinity M540 Patient Monitor

User s Reference Manual Volume 1 System Information

TOUBRO LIMITED ELECTRICAL & ELECTRONICS DIVISION - ELECTRONIC PRODUCTS 510(K) SUMMARY. (Per section )

Patient Monitoring System YM5500. Service Manual

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

Clinical Information Center Pro v5 (CIC Pro)

ncompass 8100H Series Vital Signs Monitor Operator s Manual

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

Vital Signs Monitor PC-900. User Manual

PM Portable Multi-parameter Patient Monitor. Operation Manual

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

User s Manual. Multiparametric Vital Sign Monitor

OKM 801INFANT INCUBATOR

DPM 4 Patient Monitor. Operator s Manual

cpm 12/cPM 8 Patient Monitor Operator s Manual

CARDELL Veterinary Vital Signs Monitor

VITALOGIK= 4000 / 6000 Series Configured Patient Monitors SERVICE MANUAL FDM REV.A

Transcription:

Meditec M700 Series Patient Monitors

Advanced Monitoring Parameters ECGCardioTecTM 1lead ECG Analysis 1lead ECG to analyze I, II,III,aVR, avl, avf, V1V6 and display these waveforms on the same screen Two separate ECG cable to get accurate1lead ECG analysis 1lead ECG waveform display SpO The first signal processing and sensor technology capable of accurately monitoring physiology during motion artifact and low perfusion Gold Standard of SpO Identifies the venous blood and other noise, isolates them, and using proprietary techniques, etracts the arterial signal Mainstream CO & Sidestream CO CAPNOSTAT 5 Mainstream CO & LoFlo Sidestream CO Nomoline Sampling line Adult/Pediatric and Infant airway adapters Single use & Reusable Adapters for all kinds of patient

Advanced PlugIn Modules MultiGAS Masimo Sidestream & Mainstream Paramagnetic O sensors Long life cycle Saving ongoing hospital cost Support 4Channel IBP measurement Electroencephalography EEG measurement Provides realtime waveform from 4 channels / 8 channels / 16 channels EEG module is designed for continuous, realtime monitoring of adult, paediatric and neonatal patients in anaesthesia and intermediate/critical care environments. Abbott / Edwards/ BD / Utah IBP accessories can be selected to monitoring ABP, PAP, CVP, ICP etc ICG US BIoz Noninvasive Hemodynamic Impedance cardiograph for noninvasive continuous hemodynamic monitoring Microsignal transmission through disposable electrode Measurement and display of ICG Blood volume and Blood Flow Velocity varies with heartbeat. DISQ technology processes impedance signal variation Variation of impedance applies to noninvasive Z MARC algorithm for acquiring SV, CO, SVR, Contractility and TFC etc. M797 & M757 modular monitors with option of transport monitor and separate modules for all vital signs Calculation Screens for Clinical use Module Epansion Rack (M797, M757) Drug Oygenation Ventilation Kidney Hemodynamic

Feature M797 M777 M771 17 15 19 Modular Upgradable Modular Anaesthetic Gas Module (CO, N O, HAL, ISO, ENF, DES, SEV, MAC) Paramagnetic Oygen Monitoring Cardiac Output Depth of Anaesthesia / BIS Respiratory Mechanics (RM) SVO ICG Impedance Cardiography Neuromuscular Transmission (NMT) EEG Up to 1 Up to 1 Up to 1 Waveform Recall Function Drug Calculator 10 hrs 10 hrs 10 hrs Defibrillation Interface & Cautery Protection Pacemaker Detection hrs 4 hrs hrs 4 USB & SD Card USB & SD Card 4 USB & SD Card TFT Screen Size Touch Screen Operation Type ECG Leads 1 Lead ECG Monitoring & Analysis ECG Review Arrhythmia & ST Segment Analysis SpO Temp Channels IBP EtCO Oy CRG Waveforms Graphics & Tabular Trends Builtin Liion Battery Backup Data Storage and Review HL7 Compliant Nurse Call Compatible 11 Kg 4.8 Kg 6 Kg Module Epansion Rack Wall Mount Standard Mobile Trolley Bed Rail Mount Connectivity with Central Monitoring System Inbuilt Thermal Printer Alarm System (Audible & Visual) Net Weight Option for Transport Monitor W

M757 M75 M751 M747 M707 1.1 1.1 1.1 1.1 4.3 Modular Modular Upgradable Upgradable PreConfigured Up to (optional) Up to (optional) Any One Up to 1 Up to 8 Up to 1 Up to 1 Up to 10 hrs 10 hrs 10 hrs 10 hrs 48 hrs 4 hrs 4 hrs 4 hrs 5 hrs 8 hrs 4 USB & SD Card USB USB & SD Card 1 USB 5.9 Kg 3.4 Kg 4.8 Kg 3 Kg Light Weight 1. Kg

Technical Specifications Standard Parameters Display NIBP General Parameters Method Oscillometric Mode Manual, Auto, Continuous Measuring Interval in AUTO mode 1//3/4/5/10/15/30/60/90/ 10/40/480 Min Continuous 5min, interval 5s Measuring Type Systolic Pressure, Diastolic Pressure, Mean Pressure Cuff Pressure measuring Range 0 300 mmhg Pressure 1 mmhg Mean error 3 mmhg Maimum Standard deviation 3 mmhg Over pressure protection Dual Over pressure protection Suitable Bedside monitors for Adult/Paediatric & neonatal patients User selectable priority alarms Red, Yellow, Orange color coded 6.5mm/s, 1.5mm/s, 5mm/s, 50mm/s Sweep Speed Various working Standard Monitoring Display, Large Font Intensive interface selectable Care Display, Trend Graph/ Monitoring CoDisplay, Bed to Bed view Display (optional), OyCRG Dynamic View Display, Drug Dose Calculation Interface Tabular & Graphical trends Trends Events ECG, SpO, NIBP with waveform & review ECG Measured unit mmhg/kpa selectable Lead Mode Measurement types Systolic, Diastolic, Mean Systolic : 40300 mmhg Diastolic : 1015 mmhg Mean : 035 mmhg Pressure range for Paediatrics Systolic : 035 mmhg Diastolic : 10150 mmhg Mean : 0165 mmhg Pressure range for Neonates Systolic : 1035 mmhg Diastolic : 10100 mmhg Mean : 0110 mmhg 3 Leads (I, II, III), 5 Leads (I, II, III, avr, avl, avf, V) 1 Leads ((I, II, III, avr, avl, avf, V1 V6) Waveform Up to1 waveforms display on screen 4 selectable plus 0.5, 0.5, 1, cm/mv PACE Detection Automatic Defibrillation energy distributary Input voltage range ±8mV, polarized voltage: ±500mV CMRR Diagnosis >100 db (no 50Hz/60Hz software wave trap) Monitor >110 db (has 50Hz/60Hz software wave trap) Surgery >100dB (50Hz/60Hz software wave trap) System noise <30µV pp (RTI) HR Measuring and Alarm Range Adult/Paed Neo Accuracy Sensitivity Differential Input Impedance Electrode offset potential Patient leakage current ECG Signal Range ST Segment Monitoring Range Measure and Alarm 15 bpm 300bpm 15 bpm 350bpm ±1% or ±1bpm, which great 1 bpm > 00 μv PP 5 MΩ 300mVd.c. 600mVd.c. < 10 ua 6 mv (Vpp)..0 +.0 mv Respiration SpO Method Measuring Range Alarm Range Accuracy with Adult / Paediatric with Lowperfusion Self / Nellcor / Masimo 1 100% 1 100% 1% Neonate 1 digit (70% 100% SpO) Undefined (0 70% SpO) 1 digit (70% 100% SpO) Undefined (0 70% SpO) Pulse Rate Measuring and Alarm Range 0 300bpm Temp Channel Sensor type Accuracy Measuring Range 0 50 C YSI (B Series) and CFFI 0.1 C 0.1 C (5 C 45 C), 0. C (0 5 C, 45 50 C) Method Impedance between RF (RALL), RL (RALA) Respiration Rate Measuring and Alarm Range: Adult 0 rpm 10 rpm Neo/Ped 0 rpm 180 rpm 1 rpm Accuracy rpm Gain Selection 0.5,0.5, 1,, 3, 4, 5 Technical Specifications Optional Parameters IBP CO Channel Up to 4 channel Label ART, PA, CVP, RAP, LAP, ICP, P1, P Static Pressure Measuring Range ()50 +300 mmhg (up to 350 mmhg) Static Pressure Accuracy ±% or ±1mmHg whichever is higher Dynamic Pressure Measuring Range ()50 +300 mmhg Dynamic Pressure Accuracy % or 1mmHg which bigger Measuring and Alarm Range ART 0 300 (mmhg) PA 6 10 (mmhg) CVP/RAP/LAP/ICP ()10 40 (mmhg) P1/P ()50 300 (mmhg) 1 (mmhg) Zero range 00 mmhg Channel Measuring Mode Measuring Range CO 0 150 mmhg Unit mmhg, %, Kpa CO 1mmHg Accuracy AwRR ±1 rpm Infrared Absorption Technique Sidestream or Mainstream AwRR InCO 150 rpm 1 mmhg, 0.1%, 0.1Kpa 1mmHg Accuracy CO mmhg, 0 40 mmhg Reading 5%, 41 70 mmhg Alarm Delayed AwRR Response time 10 40 seconds <3 seconds, includes transport time, risetime 1%

Technical Specifications Optional Parameters Depth of Anaesthesia/ BIS Cardiac Output (CO) Method Measuring range CO TB CO Accuracy CO TI Output parameters Alarm range Thermodilution Technique 0.1 0 L/min 3 43 C TI 0.1 L/min TB, TI 5% or 0. L/min TB 0.1 C CO, Hemodynamic Calculation 3 43 C ()1 7 C 0.1 C 0.1 C Neuromuscular Transmission (NMT) Microprocessorcontrolled Stimulator Mode Surface Electrodes Needle Electrodes TOF, TOFS, PTC, 1Hz Twitch, 0.1Hz Twitch, DBS 3.3 and 3. (double burst), Tetanic Stimulation (burst), 5s50Hz or 100Hz Builtin, direct thermal piel array recorder up to 3 channel printing Output (accuracy±5% of full scale value) 1,, 3 channel selectable Constant current, 060mA(01/18µC) up to 5Kohm, Monophasic, 00µs or 300µs pulse width Print speed 5mm/s, 50mm/s Paper width 50mm Constant current, 06mA (00.4µC) up to 5KOhm. Monophasic, 40µs pulse width Power Supply Acceleration Transducer Accuracy±5% of full scale value Temp. Sensor Range 0.041.5 C (accuracy ±5 C) Gas Measuring range CO NO Halothane Enflurane Desflurane Other Recorder Input Voltage Input Frequency AC 100V 40V 50/60Hz Environmental Conditions Multigas (AG) Technology Bispectral Inde (BIS) 0 100 Electromyographic Strength (EMG) 30 80 db (where 1µV = 40dB) Signal Quality Inde (SQI) 0 100% Suppression Ratio (SR) 0 100% Spectral Edge Frequency (SEF) 0.5 30.0Hz Total Power 40 100dB (where 1µV = 40dB) Burst Count 0 30 (with an Etend Sensor only) EEG (Continuous, two channel, realtime EEG waveform) Noise (EEG Waveform) < 0.3 µv RMS (.0 µv peaktopeak) : 0.5 Hz 50 Hz EEG Bandwidth 0.5 Hz 100 Hz (3 db) ± 10% Side Stream or Main Stream Storage CO, NO, Des, Iso, Hal, Sevo, Enf, O Operational 0 10% O 0 100% 0 100% AwRR 100 rpm 0 5% Isoflurane 0 5% 0 5% Sevoflurane 0 8% 0 18% Up to 3 waveforms display, Agent miture detection MAC value display Temp () 10 C 40 C Humidity 15% 80% Temp 0 C 40 C Humidity 15% 80% Atmospheric Pressure 700kPa 1060kPa Technical Specifications Central Monitoring System Standard Configuration Processor Display Print Data Dual Core 17"/19"/1" TFT screen HP printer 70hour full disclosure waveform review 140hour trend graphic review 10,000 alarm record review 50,000 historical patient records 180 104 English ECG, RESP, SpO, NIBP, EtCO, etc. HR, RR, ST, SpO, PR, NIBP, TEMP, etc. Recorder Features Language Waveform Parameter Alarm Alarms Eternal thermal array Realtime recording, review recording and historical Reports recording Connection Mode High and low limits alarm Arrhythmia alarm Audible and visual alarm Bedside Monitors Support maimum 18 bedside monitors Display maimum 3 patient's information Key monitoring interface, display 6 waveforms Intellectualized Bidirectional Communication Complete solution for LAN, wireless LAN, and miture networking Power Supply Input Voltage Input Frequency AC 100V 40V 50Hz ± 1Hz

Central Monitoring System Bidirectional communication with Meditec Central Monitoring Station by wired or wireless connection 64 Beds display Large font display Wave review and print preview Standard Network Interface: TCP/IP central monitoring system, be able to observe full vital signs information of the patient Full Disclosure Waveform Observation: Large screen display, be able to observe 16 bedside monitors waveforms simultaneously. Selectable Dualscreen display. Bidirectional Communication: Unique Bidirectional communication function realize the mutual control of central monitor and bedside monitors Large Storage Capacity: 70hour full disclosure waveform review, 140hour trend graph review, 1000 alarm records review. 50,000 patient historical data. All the information can be stored in disk. Data File Review: Large storage capacity of full monitoring information for easy review, analysis and statistics Dual Screen: Support various data display methods and various windows layout. It can display the waveform and numeric information of ECG, SpO, RESP, NIBP, IBP, CO, etc. The key bedside monitoring function provides more detail information to the doctor. Operating System: Userfriendly central monitoring software built on Windows platform. Advanced information integration technology to realize the concentration management of all parameters. Full digital transmission to ensure the communication accurate and reliable. Stable Internet Connection: Standard configuration for 8 bedside monitors, support maimum 18 units 8, Pinner View, Harrow, Midd, HA1 4QA, United Kingdom Tel: +44 03 643808 Email : sales@meditecengland.co.uk Website : www.meditecengland.co.uk *In view of continued product improvement Meditec International England Limited reserves the right to make changes in the equipment which may affect the information contained in this leaflet without giving any prior notice. Pictures are representative, accessories are optional and may vary at the time of supply. #55000375R Dt. 01.01.018 Meditec International England Limited