CITY M AIR PURIFIER TECHNICAL MANUAL

Similar documents
USE & CARE INSTRUCTIONS

Tower Fan MODEL# EE-5607

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

Instruction Leaflet. 99% HEPA air cleaners MODEL BAP

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

14 Upright Vacuum with HEPA Filter & Dual Power

Corning LSE 6L Digital Water Bath

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

Operating Instructions

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

CA3500, BA3500, CH3500 New Comfort

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Watt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

15-Year Limited Warranty

2 000W CYCLONIC BAGLESS VACUUM

Owners Manual Model: XXL

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Clean Air Optima HEPA UV ionizer air purifier CA-508

Series: MBC1-TC Mini Benchtop Temperature Controller

Electronic Air Purification System

Mini Tower Fan NSMTF-18

USER MANUAL TPS-M5/M55/M555

Instruction Manual and Warranty

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

CHAETOMAX. 2 in 1 Refugium LED. Owner s Manual 1

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

Model CAC 500M Media Air Cleaner

TRADITIONAL CONCEPT INSTRUCTION MANUAL WARRANTY CERTIFICATE

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

64&3 (6*%& Distributed by! ALDI, INC.! Batavia, IL 60510!

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT-900. HCT-900 User Guide _C

IMPORTANT: RETAIN FOR FUTURE REFERENCE

3 963/963E Benchtop Air Ionizer Instructions

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

CRV Clean Room Vacuum

Revolutionary Science RS-IF-202

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

Your Blast Vac Pro. Your Blast Vac Pro

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Important Notes: Please read carefully before installing your refrigerator.

THE QUALITY BRAND IN FANS

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

Installation and Operation Manual

1 HP Air Mover. Owner s Manual

TACH-IT MODEL #3568 SEMI-AUTOMATIC TWIST TIE MACHINE OPERATION MANUAL AND PARTS LIST

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

14 Bottle Wine Chiller with Digital Display CZ51186

INSTRUCTIONS AND WARRANTY

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

Owner s Manual PCS PRO

Bona Portable DCS Manual and safety instructions

Reacti-Therm I and III Heating Modules

IMPORTANT: RETAIN FOR FUTURE REFERENCE

User s Guide for the SunDanzer BFRV55

40KMC KMQ

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Operating Instructions

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

User Instruction Manual

Power 4. User Guide. HC85-P4-ZA hoover.za.com

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Instructional & Operating Manual

Owner & Operator s Manual. Table of Contents

2.4 Cu. Ft. Compact Refrigerator

Panel Mounted Heat Exchangers by Dantherm, Inc.

Sip Vacuum Cleaner 1400/35 Wet & Dry

Reacti-Therm I and III Heating/Stirring Modules

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

OptiClean. U S E R S G U I D E 6 0 A 4 S E R I E S v. Product View. Assembly. Operations. Maintenance and Care.

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

THE QUALITY BRAND IN FANS

Easy-Lam School Budget Roll Laminator

MC MC MC MC MC833130

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

NP317W

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

PS-3401 Heater / Stirrer

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Bona DCS70/Portable DCS Manual and safety instruction

AIR PURIFIERS. Small problems quickly become BIG. Clean air solutions

Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

CANISTER VACUUM MODEL SC-19

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

USER MANUAL AND TECHNICAL MANUAL

MANUAL INTELLIVENT CELSIUS

Transcription:

CITY M AIR PURIFIER TECHNICAL MANUAL WWW.CAMFIL.US

This manual includes product details, usage instructions, technical specifications, and illustrations to assist the user in application of the Camfil City M in the most efficient manner. It also includes maintenance and safety procedures associated with the use of the City M. Information in this manual is subject to change without notice. Updated versions may be found at www.camfil.us. CONTENTS Warranty & Return Policy 2 Physical Data & Technical Specifications.. 3 Electrical Data. 3 Fan Performance... 3 Use... 4 Safety Instructions... 4 Standard Components.. 4 Transport and Unpacking. 5 Airflow Details... 5 Operating the Unit... 6 Maintenance... 7 Changing the Filters.. 7 WARRANTY AND RETURN POLICY Camfil warrants the City M to be free of defects in material and workmanship for a period of one year from date of purchase. Contact your authorized Camfil distributor or Camfil for service. Camfil will accept return of the unit provided the following conditions are met: The buyer can pay return shipping on an unopened/new unit for a full refund within 30 days of original purchase. If a unit does not function properly upon receipt, Camfil will replace the defective unit and pay shipping costs for the return of the damaged unit. The buyer can return a used unit within 30 days of delivery and pay shipping plus $200 return fee (replacement filter and repackaging costs). For service, returns or technical assistance contact your local Camfil distributor or: Camfil USA, Inc. 200 Creekside Drive Washington, NC 27889 Tel: (252) 975-1141 Email: Sales-WA@camfil.com Web: www.camfil.com IMPORTANT! Before using your Camfil City M air purifier, it is important that you: 1) Read this User Manual. 2) Read the operating instructions on page 6. 3) Follow the safety instructions. All Camfil City M air purifiers have an identification plate located adjacent to the power supply. Please have the information from this plate available if discussing the unit with the Camfil servicing facility or include in any correspondence relating to the product. 2 Camfil Clean Air Solutions

PHYSICAL DATA & TECHNICAL SPECIFICATIONS Dimensions, Weight & Operating Temperature Range Height (inches) 27.6 Wide (inches) 12.9 Depth (inches) 13.3 Weight (pounds) including installed filters 35.27 Individual filter module weight (pounds) 8.75 (2 required for operation) Minimum Ambient Temperature -13 F Maximum Ambient Temperature 140 F ELECTRICAL DATA Operating Voltage Frequency Motor Speed Power 110-120 Volts 50-60 Hz 3200 RPM (max) 55 Watts (max) FAN PERFORMANCE Speed Camfil City M with Filters Installed Airflow (cfm) Energy (watts) Noise (dba) 1 22 4 16 2 39 5 16 3 56 6 16 4 75 7 22 5 148 19 38 6 256 55 53 Camfil Clean Air Solutions 3

USE The City M Air Purifier is designed as a standalone or to act as a supplement to existing ventilation systems to remove particulates and gases from the conditioned space. Common applications include office and professional environments, educational facilities, medical examination areas, waiting rooms and patient care areas, lodging and hospitality, locker rooms, workout areas and gymnasiums. Camfil does not warrant the City M products suitability for any specific application, consult your local air quality professional for guidance. SAFETY INSTRUCTIONS Read the technical manual and follow the instructions. The machine s power supply must be disconnected during installation, servicing, maintenance, and filter replacement. CAUTION: Disconnect power by pulling the plug or use the safety switch when servicing the unit. The machine is not de-energized until 5 minutes after disconnection from the power supply. 1. Rotating parts do not stop immediately. Disconnect the power supply and/or make sure the power switch is in the off position. Allow 5 minutes to elapse before servicing parts internal to the unit. 2. The City M should only be used for air purification related to dry, non-explosive particulate and non-explosive gaseous contaminants. If the City M Air Purifier is used for applications other than those listed in this manual or not under the guidance of a professional, Camfil assumes no liability for the consequences of its use in unauthorized applications. 3. The City M is designed to be a portable air purifier, fixed installations should be performed by an installation professional who assumes complete liability for the fixed installation. 4. All accessories, filters, spare parts, or add-ons used, must be approved by Camfil. All warranties become immediately void if non-camfil components are used. Please contact Camfil for the correct filter replacements, replacement parts and accessories. 5. Do not cover inlets or outlets, or insert objects through the air outlets or inlets. 6. The unit must not be used in environments where burning or smoldering objects can get into the unit. 7. The unit is for indoor use only. 8. The approved operational temperature range is: -13 F to 140 F (-25 C to 60 C). 9. The unit must not be exposed directly to water. High humidity (>85%) can affect the adsorber filter performance, optimum operating humidity range is 20% to 70%. 10. Adhere to filter handling and replacement instructions carefully. Incorrect handling can damage the filter medium and filter performance may be negatively affected. 11. Use caution when handling used filters. Incorrect handling may result in ill health or sickness. Follow the instructions for filter replacement. DESIGN The unit is a self-standing one-section housing with two filters, fan section, fan control and electrical connections. The machine is constructed of aluminium and plastic parts and is environmentally friendly and recyclable. STANDARD COMPONENTS In its standard version, the air purifier is supplied with the following components: One Camfil City M unit Technical Manual One set of standard HEPA/adsorber combination filters Electrical connector Fan instructions If anything is missing, or if you require further information about accessories, please contact Camfil. 4 Camfil Clean Air Solutions

TRANSPORT AND UNPACKING Remove all packaging carefully. If sharp objects are used to unpack the unit, be careful not to damage the machine s cables and design finish. Take special care when handling the filters. See the filter replacement section. Check that the product has not been damaged during transport. Report any transport damage to the carrier. Confirm the delivery is complete. AIR FLOW DETAILS Filters Dirty air Dirty air Fan Clean air Clean air Camfil Clean Air Solutions 5

OPERATING THE UNIT Connect the air purifier to a 110-120 VAC electrical outlet. Ensure that there is nothing obstructing the air outlets or inlets. Controller card description Press + (plus) to increase the airflow. The blue LED indicators will guide you to the airflow you have chosen (see page 3 for airflow rates. Press (minus) to lower the airflow. A red warning light will be lit at the filter change symbol, when it s time for filter replacement. When the red warning light has been lit and filters are replaced, you need to calibrate the unit by pressing + and- at the same time and hold for 5 seconds. Calibration ensures the warning light will function when it s time for the next filter replacement. On the back side of the unit is the electrical connector with fuse holder and identification plate. POSITIONING OR UNIT PLACMENT The unit must always be positioned and used indoors only. Air outlets and intakes must not be obstructed during use. Before operating the air purifier, ensure there is sufficient space (6 ) around the outlet and inlet. ELECTRICAL CONNECTION Electrical connection must be carried out by a qualified electrician. All routing of cables, etc., must be carried out in accordance with relevant regulations. The unit comes from the factory ready for plugging in. Any alterations to the machine s internal electrical systems must only be carried out by appropriately qualified persons using equipment supplied by Camfil. The unit must only be connected to the network voltage stated on the machine identification plate. PRODUCT AND THE ENVIRONMENT The air purifier is made from lead-free components. It can be recycled. Used models must always be sent to a recycling station for correct recycling and/or disposal of parts and components. FILTERS AND THE ENVIRONMENT Note that filters must not be disposed of with ordinary household waste. Scrapped filters must be handled safely. Recycling or disposal must always be carried out at an approved waste facility. If you have any questions about this, please contact your local authority or distributor for advice on correct disposal procedures. 6 Camfil Clean Air Solutions

MAINTENANCE If necessary, the unit can be cleaned using a mild cleaning agent. Before cleaning, always switch off the machine and pull out the electrical connector! INSTRUCTIONS FOR REPLACING FILTERS 1. Power off the unit by turning the safety switch or remove the electrical connector. Make sure that the blue operating LED is off. Wait 5 minutes. 2. Lift the top cover off the unit. 5. Grip the handle on top of the filter and pull it towards you. Put the filter in a plastic bag. Repeat procedure on the other filter and place in a plastic bag. 3. Push the two buttons and lift up the hatch. 6. Take a new HEPA filter out of its box. Do not touch the filter s surface. Hold the handle only. Put the filter in position and press down against the pattern of holes. The black gasket must be towards the hole pattern of the unit. 4. Take a firm grip and then pull the hatch upwards. Do steps 1-6 in reverse order. Camfil Clean Air Solutions 7

CAMFIL is the world leader in air filters and clean air solutions. Camfil is the global industry leader in clean air solutions with 50+ years of experience. Our solutions protect people, processes and the environment to benefit human health, increase performance, and reduce and manage energy consumption. Twenty-five manufacturing plants, six R&D sites and over 65 local sales offices worldwide provide service and support to our customers. The Camfil Group is headquartered in Sweden but more than 95% of sales are international. The Group has around 3,800 employees and sales more than 700 million dollars. www.camfil.com