Wall Hung Multipoint Water Heaters Installation & Maintenance Manual

Similar documents
Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Installation and User Instructions HS10U, HS15U.

MULTIPOINT SS H 50/80 & 100

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Unvented Electric Water Heater 10/15 litre Undersink

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

MULTIPOINT 30 & 50 Litre

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

HOTFLO 10 / 15. Fitting Instructions and User Guide

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Unvented water heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

HOTFLO 10 / 15. Fitting Instructions and User Guide

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Direct, Indirect, Solar & Heat Pump Un-Plumbed & Pre-Plumbed Unvented Cylinder Installation & Maintenance Manual

EPU - WM30 EPU - WM 50 EPU - WM100

Direct, Indirect & Solar Un-Plumbed & Pre-Plumbed Unvented Cylinder Installation & Maintenance Manual

Commercial Indirect / Multi Energy / Solar Unvented Water Heaters Installation & Maintenance Manual

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

SEALED THERMAL STORE

Unvented water heater

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Direct & Indirect Unvented Cylinder Installation & Maintenance Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Unvented Direct & Indirect Hot Water Cylinders (400L L)

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 210, 250 AND 300 LITRE CAPACITY INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Quantum. Installation, User and Service Manual. Hot Spring

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Powerflow Unvented water heater

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Tank In Tank Unvented Cylinder Installation & Maintenance Manual

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

Zircon Installation Manual

smart line E SLE

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Instructions for Use Installation and Servicing

Megaflo HE issue 6

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 100 TO 300 LITRE CAPACITY DIRECT AND INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

Multipoint Technical Data

Alpha CombiMax 350 and 600

Streamline Undersink. Fitting Instructions and User Guide

Hotflo Vertical Litres Installation, operation and maintenance manual

Installation Manual EXCELSIOR Unvented Water Heater

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Instructions & Maintenance

Schuco SS-TC/SC Cylinders

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Direct & Indirect Unvented Cylinder Installation & Maintenance Manual

Unvented Direct & Indirect Hot Water Cylinders

Unvented water heating

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Megaflo Eco SystemReady Unvented Indirect Hot Water Cylinders

IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION. PACK CONTENTS

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

APP STAINLESS UNVENTED HORIZONTAL HOT WATER CYLINDERS

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Technical and Installation manual All Models

WATER HEATERS INSTALLATION MANUAL

Unvented Hot Water Storage Cylinders

Installation and Servicing Instructions. Alpha CD50

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

Instructions for Installation, Servicing and Use

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

MEGAFLO Eco SystemReady Unvented Indirect Hot Water Cylinders

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

Installation and Servicing Instructions. Alpha GasSaver GS-1

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

ADVANCED WATER COMPANY LTD COPPERFORM. Advanced Water Company Ltd. Unvented Hot Water Cylinders. Supplied By Advanced Water Company Ltd

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

ADVANCE ECB ELECTRIC COMBINATION BOILER

ZIP VARIPOINT II Direct unvented water heaters.

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

Unvented Copper Hot Water Cylinders

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Multipoint ECO Horizontal Litres Installation, operation and maintenance manual

Installation & User Instructions

ZIP AQUAFLO II Unvented storage cylinders

The Professional s Choice

UNVENTED MAINS PRESSURE WATER HEATER 100, 120, 150, 170, 210, 250 AND 300 LITRE DIRECT AND INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

Flomaster. Unvented Hot Water Cylinders INSTALLATION INSTRUCTIONS FOR COPPERFORM FLOMASTER UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

Hotflo. Unvented point of use hot water

ADVANCE ELECTRIC THERMAL STORE

The Professional s Choice

MEGAFLO HE Iss 1

Transcription:

Wall Hung Multipoint Water Heaters Installation & Maintenance Manual REGISTER THIS PRODUCT ONLINE WITHIN 28 DAYS OF COMMISSIONING IRELAND www.joule.ie/register-a-product UNITED KINGDOM JL-MP-INS-001-03-2017 www.jouleuk.co.uk/register-a-product Cyclone Wall Hung Multipoint Water Heater Installation Guide 1

Warranty Card Please register your product online MUST BE COMPLETED AND THEN REGISTERED ONLINE TO COMPLETE WARRANTY Homeowner Name Address Installer Name Address Contact Tel. Contact Tel. Contact Email Contact Email Product Product Installed Serial Number Installation Date Cylinder / Mutipoint Solar Thermal Solar PV Air Source Heat Pump Integrated Heat Pump and Cylinder Underfloor Heating Direct Gas Fire Cylinder Was a Pre-Plumbed cylinder installed too? Located on cylinder badge Take from solar controller Ser. No. from String / Micro Inverter Located on external heat pump badge Located on cylinder badge Project ref. on supplied schematic Located on cylinder badge If installed, please fill out the Heat Pump Commissioning Sheet too Joule Advance Installer I accept the terms and conditions in the installation manual 2 www.jouleuk.co.uk www.joule.ie

Joule Product Warranty Terms & Conditions Joule Multipoint This water heater is guaranteed for a period of five years from the date of purchase with the exception of the element and thermal controls which are guaranteed for a period of two years provided: 1. The unit has been installed in accordance with these instructions and all necessary inlet controls and safety valves have been fitted correctly. 2. Any valves or controls are of Joule recommended type. 3. The unit has not been tampered with and has been regularly maintained as detailed in these instructions. 4. The unit has been used only for heating potable water. 5. Within 60 days of installation, the user completes and return certificate supplied along with proof of purchase to register the product. The unit is not guaranteed against damage by frost and the immersion heater is not guaranteed against excessive scale build up. This guarantee does not affect the statutory rights of the consumer. Cyclone Wall Hung Multipoint Water Heater Installation Guide 3

Warning To The User Do not remove or adjust any part of this unvented water heater. If the unvented water heater develops fault, such as a low of water from the discharge pipe switch the heater off. In all cases contact a competent installer. The Benchmark Log Book at the end of the manual must be filled in at annual service. Warning To The Installer Read the installation instructions before commencing. Unvented water heaters are a controlled service as defined in the latest edition of the building regulations and should only be fitted by a competent installer. The installation is subject to building regulation approval. You must notify the local authority of intention to install. After installation the instructions manual must be completed and left with the householder. Use only manufacturer s recommended replacement parts. Installed by Installer Name Address Contact Tel. Completion Date 4 www.jouleuk.co.uk www.joule.ie

Table Of Contents 6 Introduction 10 Included In The Box 11 Technical Specifications 12 Dimensions 13 Installation 19 Commissioning 20 Explanation To User 21 Maintenance 23 Fault Finding 24 Service Record Cyclone Wall Hung Multipoint Water Heater Installation Guide 5

Introduction The instructions are an integral part of the appliance and must be given to the end user on completion of the installation in order to comply with the current regulation. It is important to carefully read the manual to understand all the information to enable safe installation, use and servicing. These instructions consist of details for installation, servicing, fault finding and replacement of parts for the cylinder purchased. JOULE will not accept any liability in the event of damage for not complying with the guidance in this instruction manual. The instructions for this installation manual apply to the range of JOULE Multipoint Water Heaters. Safety is paramount when installing unvented hot water systems and the following instructions must be adhered to: Only certified competant installers can install, commission and service the equipment supplied. The cylinder must be used for potable hot water only. Any other applications will be considered incorrect use and JOULE will not be held liable for any losses resulting from such use. All installation and maintenance instructions must be observed to ensure the correct operation of the equipment. The electric immersion must not be switched on unless the cylinder is completely full of water. Domestic hot water may be stored at temperatures exceeding 60 C. Preventative measures should be put in place to negate the possibility of scalding. A maintenance schedule should be put in place with a competent person to service the equipment annually to comply with the warranty conditions. When servicing the system the mains supply to the cylinder should be isolated. Only genuine spare parts should be used. A full list of items with relevant codes can be found on page 13. The installation must be carried out by a person competent to install unvented hot water systems. The installation must be carried out in accordance with the following recommendations: All current Building Regulations issued by the Department of the Environment, i.e. Approved Document L1 Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department UK Water Regulations/Byelaws (Scotland) Health & Safety Document No. 635 (The Electricity At Work Regulations 1989). The installation should also be in accordance with the following British Standard Codes of Practice: BS 5449:1990 Forced circulation hot water systems BS 5546:2000 Installation of hot water supplies for domestic purposes BS 5918:1989 Solar heating systems for domestic hot water BS 6700:2006 Design, installation, testing and maintenance of services supplying water. Failure to install this appliance correctly could lead to prosecution and will invalidate the guarantee. It is in your own interest and that of safety to ensure that the law is complied with. 6 www.jouleuk.co.uk www.joule.ie

Handling Care must be taken when transporting, storing and installing the equipment: At least two people should lift the cylinder to prevent injuries. The cylinder must be stored in a dry area and must never be set down hard during handling. Packaging should only be removed at the installation location. The cylinder must be installed on a level or with the required load bearing capability. Installation, servicing, maintenance and repair must be carried out by a competent person. All electrical wiring must be carried out by a qualified electrician and be installed in accordance with current I.E.E Wiring Regulations. A lack of safety devices can lead to potentially fatal injuries, all necessary safety devices must be installed correctly in the system. The use of an electric immersion may lead to the build up of electrical potential in the water. This can in turn cause corrosion of the immersion. To prevent this, ensure the immersion heater, and the hot and cold pipework are correctly bonded and connected to the earth line. If plastic pipes are used they must be approved temperature resistant to 95 C at a pressure of 10bar. A thermostatic mixer should be installed in the system to prevent the risk of scalding. If there are leaks found in the system, shut o the cold water stop valve from the main supply and contact a competent person immediately. What Is Benchmark? Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hot Water Industry Council who manage and promote the scheme. Visit www.centralheating.co.uk HWA Charter Member Joule are proud to be a charter member of the the Hot Water Association (HWA), who has been formed through the union of the two UK industry trade bodies, WMA (Water Heater Manufacturers Association) and MODUS (Manufacturers Of Domestic Unvented Systems). The objectives of the HWA are To be recognised as the leading body in domestic hot water storage and, through cooperation and partnerships, to support, drive and promote the sustained growth and improvement of standards within the entire domestic hot water industry. The HWA operate a Charter that all members of the association observe. The HWA Charter Statement requires that all members adhere to the following: To supply fit for purpose products clearly and honestly described To supply products that meet or exceed appropriate standards and building and water regulations To provide pre and post technical support To provide clear and concise warranty details to customers Cyclone Wall Hung Multipoint Water Heater Installation Guide 7

Introduction Water Supply The performance of any unvented system is only as good as the mains water supply available. To this e ect the maximum possible water demand should be assessed, with the knowledge that the mains supplies both hot and cold services simultaneously. The water heater itself operates at a pressure of 3bar, controlled by the inlet control set, and is capable of delivering over 50 litres per minute. The high quality inlet control set has been designed to make the most of the low rates available. The water supply should be checked to ensure it can meet these requirements. If necessary, consult the local water authority regarding the likely pressure and flow rate availability. Consideration should be given to upgrading existing 1 2 (15mm) cold mains pipework to a larger size if the recommended minimum pressure / flow rate is not being achieved. JOULE recommend that primary pipework used has a minimum diameter of 22mm to ensure low pressure loss. A high static (no flow) mains pressure is no guarantee of good flow availability. In a domestic installation 1.5bar and 25ltr/min should be regarded as the minimum. The maximum mains pressure that the inlet control set can cope with is 10bar. Change Of Water Supply The changing or alternating from one water supply to another can have a detrimental effect on the operation and/or life expectation of the water heater storage cylinder, pressure temperature relief valve and heating unit. Where there is a changeover from one water supply to another, e.g. a rainwater tank supply, bore water supply, desalinated water supply, public reticulated water supply or water brought in from another supply, then water chemistry information should be sought from the supplier or it should be tested to ensure the water supply meets the requirements given in these guidelines for the Joule warranty to apply. Water Chemistry This water heater must be installed in accordance with this advice to be covered by the Joule warranty. This water heater is manufactured to suit the water conditions of most public reticulated water supplies. However, there are some known water chemistries which can have detrimental effects on the water heater and its operation and/or life expectancy. If you are unsure of your water chemistry, you may be able to obtain information from your local water supply authority. We recommend not to use water softener, however if it is used the water is required to be kept at potable standards. This water heater should only be connected to a water supply which complies with these guidelines for the JOULE warranty to apply. 8 www.jouleuk.co.uk www.joule.ie

Water Chemistry Levels Affecting Warranty The JOULE warranty of this water heater will not cover resultant faults on components including the storage cylinder where water stored in the storage cylinder exceeds at any time any of the following levels: Components Total Dissolved Solids Total Hardness Chloride Magnesium Calcium Soldium Iron Maximum Permitted Levels 600 mg/litre 200 mg/litre 300 mg/litre 10 mg/litre 20 mg/litre 150 mg/litre 1 mg/litre Maximum ph 9.5 Minimum ph 6.5 Total Dissolved Solids (TDS) Some water analysis reports may state the conductivity of the water rather than the level of total dissolved solids. Conductivity, measured in microsiemens per centimetre (μs/cm), is directly proportional to the TDS content of the water. TDS, in mg/l, is approximately 70% of the conductivity in μs/cm. The JOULE warranty will not cover resultant faults to the storage cylinder if this water heater is connected at anytime to a water supply where the TDS content of the water exceeds 600 mg/l. 16 In locations where TDS approaches 600 mg/l, e.g. due to sediment, we strongly recommend fitting an appropriate filter to ensure water entering or in the water heater does not exceed this level at any time i.e. due to sediment build up. Cyclone Wall Hung Multipoint Water Heater Installation Guide 9

Included In The Box TZ9-4.0-0000.5 TZU-000015X22 TZG-3.0-0.75L Capacity (ltr) 30 50 80 100 120 Expansion Vessel TV-P-000019L Inlet Group TZG-3.0-0.75L T&P Valve TZ9-4.0-0000.5 Tundish TZU-000015X22 Multipoint Inlet Control Group Tundish T&P Valve (fitted) 3kW Immersion (fitted) Expansion Vessel 10 www.jouleuk.co.uk www.joule.ie

Technical Specifications Horizontal Models 80L 100L 120L Capacity (L) 80 100 120 Length (mm) 930 1090 1250 Diameter (mm) 495 495 495 Element Rating (@230V) 3kW 3kW 3kW Weight Empty (kg) 28 32 36 Weight Full (kg) 107 133 154 Rated Pressure (bar) 6 6 6 Connection Size 3/4" 3/4" 3/4" Pressure Tested (bar) 12 12 12 Heat Up Time (mins)* 86 107 130 Recovery Time (mins)** 60 75 91 Factory Fitted Temp. Guage Yes Yes Yes Factory Fitted T&P relief Valve Yes Yes Yes ErP Rating C C D Product Code OJ-000HV 0803KW OJ-000HV 1003KW OJ-000HV 1203KW Vertical Models 30L 50L 80L 100L 120L Capacity (L) 30 50 80 100 120 Height (mm) 580 830 860 1020 1180 Diameter (mm) 380 380 495 495 495 Element Rating (@230V) 2kW 2kW 3kW 3kW 3kW Weight Empty (kg) 16 22 28 32 36 Weight Full (kg) 46 72 107 133 154 Rated Pressure (bar) 6 6 6 6 6 Connection Size 3/4 3/4 3/4" 3/4" 3/4" Pressure Tested (bar) 12 12 12 12 12 Heat Up Time (mins)* 48 80 86 107 130 Recovery Time (mins)** 34 56 60 75 91 Factory Fitted Temp. Guage Yes Yes Yes Yes Yes Factory Fitted T&P relief Valve Yes Yes Yes Yes Yes ErP Rating C C C C D Product Code OJ-000MV 0503KW OJ-000MV 0503KW * Heat up times are based on heating from 20 C through 45 C ** Recovery times are based on heating 70% of capacity through 45 C OJ-000MV 0803KW OJ-000MV 1003KW OJ-000MV 1203KW Cyclone Wall Hung Multipoint Water Heater Installation Guide 11

Dimensions Figure 1 30 50 80 100 120 A 580 830 860 1020 1180 B 380 380 495 495 495 12 www.jouleuk.co.uk www.joule.ie

Installation This appliance must be earthed. It is suitable for AC supply only. Electrical installation must be carried out by a competent electrician and be in accordance with the latest I.E.E. wiring regulations. Ensure the electrical supply is switched off before making any connections to the Cyclone Multipoint Waterheater. The Cyclone Wall Hung Multipoint Water Heater unvented water heater is factory fitted with a Temperature/Pressure Relief Valve which must not be removed, blocked or restricted in any way. Expansion must be accommodated within the system. The expansion vessel & combination valve provided in the installation kit must be installed and will fulfill this function. Location 1. Using Figure A and the dimensions table as a guide mark the positions of the fixing points. Drill and plug the wall with suitable fixings. 2. Fix the top two fixings first followed by the bottom two fixings. 3. The Cyclone Wall Hung Multipoint Water Heater must be plumb and vertically wall mounted using the wall brackets fitted to the heater. The water connections must always be at the bottom of the unit. 4. Enough space should be left below the unit for pipe connections and above the unit for access to the Temperature/Pressure Relief Valve (400 mm minimum). 5. Ensure that the wall can support the full weight of the unit and that there are no hidden services (electricity, gas or water) below the surface of the wall. 6. Do not install where the unit may freeze. 7. Do not install in direct sunlight or where the unit is open to the elements. 8. The latest IEE wiring regulations may contain restrictions concerning the installation of these units in bathrooms. The Multipoint Water Heater is heavy. Prior to fixture ensure the wall is strong enough to take the weight of the water heater when full. No other valves should be placed between the expansion valve and the Cyclone Wall Hung Multipoint Water Heater cylinder. The expansion valve connection must not be used for any other purpose. Cyclone Wall Hung Multipoint Water Heater Installation Guide 13

Plumbing 1. To make installation of the Cyclone Wall Hung Multipoint Water Heater easier it is supplied with a Pressure Relief Valve. 2. Plumb the Multipoint water heater as shown below in Figure 2. Ensure the Pressure Reducing Valve is installed in the correct orientation by reference to the direction of the flow arrow marked on it. 3. The water connections to the unit are 3/4 BSP male with Ø22mm compression fittings suitable for Ø22mm copper pipe. 4. Inlet and outlet are colour coded accordingly for hot and cold. Several hot outlets via conventional taps can be served, however, individual site demands should be considered when choosing capacity and the number of outlets. 5. It is recommended that a WRAS listed isolating valve (not supplied) is fitted on the cold water supply to the heater before the Pressure Reducing Valve. 6. Plumbers Paste must not be used as it can impair the operation of the valves. Figure 2 - Plumbing Schematic Discharge It is a requirement of Building Regulations that any discharge from an unvented system should be visible and safely conveyed away from the system without danger to persons in or about the building where it is installed. The discharge pipe should be fitted in accordance with the requirements and guidance notes of Building Regulations. Building Regulation G3 Requirements and Guidance section 3.9 are reproduced in the following sections. Information Sheet No.33 available from the British Board of Agrement gives further advice on discharge pipe installation. For discharge pipe arrangements not covered by G3 Guidance or BBA Info sheet No. 33 advice should be sought from your local Building Control Officer. The discharge pipework will convey any discharge from the unvented cylinder Temperature and Pressure Relief Valve. (A discharge pipe will also be required from the Expansion Valve fitted to the Cold Water 14 www.jouleuk.co.uk www.joule.ie

Combination Valve) Where practical this can be feed into the discharge pipe from the Cyclone Wall Hung. It is recommended that an additional tundish is fitted into this discharge pipe to give an early indication of operation of the Expansion Valve. In some instances it may be possible to discharge into an internal waste system and soil stack. To do this a self sealing waste valve must be fitted into the discharge pipe after the tundish to prevent foul odours or back-pressurisation from the waste system entering the building via the tundish. In these systems it is essential that the tundish is fitted in a visible position as the final point of discharge will not be visible. Consult the manufacturer s recommendations with respect to the correct fitting, orientation and waste and soil stack materials selection. It will also be necessary to get dispensation from your local Building Control Officer to discharge in this manner. Discharges from an unvented system can be up to 95 C for several minutes, ensure any waste or soil pipe connected to the discharge can safely accept these conditions. G3 Requirement there shall be precautions to ensure that the hot water discharged from safety devices is safely conveyed to where it is visible but will not cause danger to persons in or about the building. Water may drip from the discharge pipe of the pressure-relief device and that this pipe must be left open to the atmosphere. The expansion relief valve is to be operated regularly to remove lime deposits and to verify that it is not blocked. The discharge pipe connected to the pressure relief device is to be installed in a continuously downward direction and in a frost free environment G3 Guidance Section 3.9 The discharge pipe (D1) (see Figure 03) from the vessel up to and including the tundish is generally supplied by the manufacturer of the hot water storage system. Where otherwise, the installation should include the discharge pipe(s) (D1) from the safety device(s). In either case the tundish should be vertical, located in the same space as the unvented hot water storage system and be fitted as close as possible and within 600mm of the safety device e.g. the temperature/pressure relief valve. The discharge pipe (D2) from the tundish should terminate in a safe place where there is no risk to persons in the vicinity of the discharge, preferably be of metal and: a. Be at least one pipe size larger than the nominal outlet size of the safety device unless its total equivalent hydraulic resistance exceeds that of a straight pipe 9m long i.e. discharge pipes between 9m and 18m equivalent resistance length should be two pipe sizes larger, and so on. Bends must be taken into account in calculating the flow resistance. Refer to Table 1 and the worked example. b. Have a vertical section of pipe at least 300mm long below the tundish before any elbows or bends in the pipework. c. Be installed with a continuous fall. d. Have discharges visible at both the tundish and final point of discharge, but where this is not possible or is practically difficult there should be clear visibility at one or other of these locations. Cyclone Wall Hung Multipoint Water Heater Installation Guide 15

An alternative approach for sizing discharge pipes would be to follow BS6700:1987 Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their cartilages, Appendix E, Section E2 and Table 21. Examples of acceptable discharge arrangements are: i. Ideally below a fixed grating and above the water seal in a trapped gully. ii. Downward discharges at low level; i.e. up to 100mm above external surfaces such as car parks, hard standings, grassed areas etc. are acceptable providing that where children may play or otherwise come into contact with discharges a wire cage or similar guard is positioned to prevent contact, whilst maintaining visibility. iii. Discharges at high level; e.g. into a metal hopper and metal down pipe with the end of the discharge pipe clearly visible (tundish visible or not) or onto a roof capable of withstanding high temperature discharges of water and 3m from any plastics guttering system that would collect such discharges (tundish visible). iv. Where a single pipe serves a number of discharges, such as in blocks of flats, the number served should be limited to not more than 6 systems so that any installation discharging can be traced reasonably easily. The single common discharge pipe should be at least one pipe size larger than the largest individual discharge pipe (D2) to be connected. If unvented hot water storage systems are installed where discharges from safety devices may not be apparent i.e. in dwellings occupied by blind, infirm or disabled people, consideration should be given to the installation of an electronically operated device to warn when discharge takes place. The discharge will consist of scalding water and steam. Asphalt, roofing felt and nonmetallic rainwater goods may be damaged by such discharges. Worked example of discharge pipe sizing The example below is for a G1/2 temperature relief valve with a discharge pipe (D2) having 4 No. elbows and length of 7m from the tundish to the point of discharge. From Table 1: Maximum resistance allowed for a straight length of 22mm copper discharge pipe (D2) from a G1/2 temperature relief valve is 9.0m. Subtract the resistance allowed for 4 No. 22mm elbows at 0.8m each = 3.2m Therefore the permitted length equates to: 5.8m 5.8m is less than the actual length of 7m therefore calculate the next largest size. Maximum resistance allowed for a straight length of 28mm pipe (D2) from a G1/2 temperature relief valve equates to 18m Subtract the resistance of 4 No. 28mm elbows at 1.0m each = 4.0m Therefore the maximum permitted length equates to 14.0m As the actual length is 7m, a 28mm (D2) copper pipe will be satisfactory. 16 www.jouleuk.co.uk www.joule.ie

Valve outlet size Min. size of disch. pipe D2 Min. size of disch. pipe D2 from tundush Max. resistance allowed, expressed an a length of straight pipe (i.e. numbers of elbows or bends) Resistance created by each bend G 1/2 15mm 22mm 28mm 35mm up to 9m up to 18m up to 27m 0.8m 1.0m 1.4m G 1/2 22mm 28mm 35mm 42mm up to 9m up to 18m up to 27m 1.0m 1.4m 1.7m G 1/2 28mm 35mm 42mm 54mm up to 9m up to 18m up to 27m 1.4m 1.7m 2.3m Table 1 - Sizing of copper discharge pipe (D2) for common T&P relief valve sizes. Safety device (e.g. Temp. Relief Valve) Metal discharge pipe (D1) from Temp. Relief Valve to Tundish Max. 600mm Tundish Min. 300mm Discharge below fixed grating (Building Reg. G3 Section 3.9d gives alternative points of discharge Discharge pipe (D2) from tundish with continuous fall. See Building Reg. G3 Section 3.9d I-IV Table 4 and worked example Fixed grating Trapped gully Diagram 3 - Discharge Pipe arrangement Cyclone Wall Hung Multipoint Water Heater Installation Guide 17

Electrical This appliance must be earthed. It is suitable for AC supply only. Electrical installation must be carried out by a competent electrician and be in accordance with the latest I.E.E. wiring regulations. 1. The electrical supply to the property must be checked to ensure it is of sufficient current rating and voltage. 2. The circuit must incorporate a double pole isolating switch with a contact separation of at least 3mm in both poles. 3. The supply cable should be 2.5mm² 3 core HOFR sheathed and must be routed via the cable seal and entry provided with the outer sheath of the cable firmly secured by tightening the screws on the cable clamp. 4. The wires are colour coded as follows: Green & Yellow - EARTH Brown - LIVE (L) Blue - NEUTRAL(N) 5. The Cyclone Wall Hung water heater has one heating element. The heating element is controlled by a combined thermostat and thermal cut out, refer to Figure 4 for wiring details. 6. Do not operate the immersion heater until the Cyclone Wall Hung has been filled with water. Terminal Block Electric Thermostat High Limit Stat Immersion Heater Element Earth Pilot Lamp Figure 4 - Wiring Diagram 18 www.jouleuk.co.uk www.joule.ie

Commissioning Plumbing Water that is left standing in a stainless steel water cylinder for long periods without draw-off will become de-oxygenated and potentially corrode the vessel material. If the installation is to be left unusued following installation and commissioning, the water cylinder must be drained or regularly flushed (once a week) through with frensh mains water. 1. Check that all installation and discharge pipe requirements have been met. 2. Check that all water connections are tight. 3. Open a hot water tap, turn on mains water supply to the Cyclone Wall Hung Multipoint Water Heater. 4. Allow Cyclone Wall Hung to fill and leave hot tap running for a short while to purge any air and flush out the pipework. Close the hot tap and check the system for leaks. 5. Manually test the operation of the Temperature/Pressure Relief Valve and the Pressure (expansion) Relief Valve. Ensure water flows freely from the valves and through the discharge pipes. Electrical Preliminary Checks Ensure all power supplies are switched off. Check all electrical connections are tight. Check all earth bonding links are connected, tight and un-damaged. Check earth continuity, short circuits, polarity and resistance to earth. 1. Do not switch on the electrical supply until the Cyclone Wall Hung Multipoint Water Heater has been filled with water and checked for leaks. 2. Check that all electrical requirements have been met. 3. Check that all electrical connections are tight. 4. Switch on the electrical supply. The indicator light will illuminate during heating. When the set temperature is reached the indicator light will go out. 5. The set temperature can be adjusted by rotating the control knob. This can be set to give temperatures in the range 10 C to 80 C. In hard water areas it is advised that the maximum temperature is restricted to prevent build up of scale. Cyclone Wall Hung Multipoint Water Heater Installation Guide 19

Explanation To User 1. The Cyclone Wall Hung unvented heater stores water at the temperature set on the adjustable control knob. This can be set to give temperatures in the range 10 C to 80 C. In hard water areas it is advised that the maximum temperature is restricted to prevent build up of scale. To avoid risk of freezing when the heater is not in use for long periods during the winter months, do not switch off the electrical supply and set the thermostat to its minimum position. N.B. This will not protect other system pipework. 2. The indicator lights will be illuminated when the unit is heating. 3. To ensure the heater continues to operate at its optimum performance it should be periodically maintained in accordance with the instructions given under the section headed 20 www.jouleuk.co.uk www.joule.ie

Maintenance Do not block or restrict the discharge from any safety valve fitted Do not tamper with any safety valve fitted If water discharges from any safety valve fitted switch off the electrical supply to the unit immediately. Contact the Joule Service Team or an approved installer. Do not turn the electrical supply on again until the unit has been checked and approved by a qualifier installer Maintenance Disconnect from all electrical supplies before beginning any work on the Cyclone Wall Hung Multipoint Water Heater. Fluid contained in the cylinder may be very hot To ensure the continued safe and efficient operation of the Cyclone Wall Hung it should be regularly maintained. Maintenance should be carried out by a competent person and any replacement parts used should be authorised JOULE Cyclone Wall Hung spare parts. It is recommended that maintenance is carried out annually and should include the checks detailed in the sections on page 21 & 22. Descaling Little maintenance is required, however in hard water areas the unit will require periodic descaling to ensure efficient operation. To descale the unit: 1. Switch off and disconnect the electrical supply. Turn off the water supply to the unit. 2. Open a hot tap to relieve any system pressure. Empty unit by opening the drain cock in the inlet pipework. 3. Remove the terminal cover by removing the two supporting screws holding it in place. 4. Disconnect the electrical terminals to the element. Withdraw the thermostat and thermal cutout capillary tubes from the pockets on the element plate. 5. Remove the element plate assembly by unscrewing the element backnut using the element tool provided A quantity of water may still be present in the container, it is recommended that a container be placed under the unit to collect any spillage. 6. Remove any loose scale from the container. Carefully clean off any scale from the element and thermostat pocket. DO NOT clean scale from interior container walls. 7. Re-assemble the element plate assembly fitting a new sealing gasket. Rewire the unit with reference to Figure 4 - Wiring Diagram 8. Re-commission the unit following the Installation and Commissioning instructions. Cyclone Wall Hung Multipoint Water Heater Installation Guide 21

Safety Valves The Temperature/Pressure Relief Valve and the Pressure (Expansion) Relief Valve should be regularly checked. To check the valves: 1. Manually operate the valve by twisting the cap. Ensure water flows freely from the valves and through the discharge pipes (NOTE: the water discharged may be very hot). Ensure the valves reseat correctly when released. 2. Clean the strainer incorporated in the Pressure Reducing Valve. To inspect and clean the strainer turn off the mains water supply to the heater and open a hot tap to relieve the system pressure. Unscrew the black cap from the Pressure Reducing Valve and remove. The strainer will be removed with the cap. Wash any particulate matter from the strainer under cold clear water only. Replace the cap assembly ensuring the sealing ring is correctly fitted. Do not use any other type of sealant. Close hot tap, open mains stop cock and check for leaks. Expansion Vessel Precharge Pressure The Expansion Vessel should have a precharge pressure of 3.5 bar (51psi). This can reduce over time and eventually require re-charging. To do this: 1. Turn off water supply to the unit; open a hot tap to relieve system pressure. 2. Remove dust cap from top of Expansion Vessel. 3. Check pre-charge pressure using a tyre pressure gauge. If the pressure is lower than 3.5 bar (51 psi) it should be recharged using a tyre pump (Schraeder Valve type). Do not overcharge. 4. Re-check pressure and when correct replace dust cap. 5. Turn on mains water supply and close hot tap. 22 www.jouleuk.co.uk www.joule.ie

Fault Finding Disconnect from all electrical supplies before beginning any work on the Cyclone Wall Hung Multipoint Water Heater. Fluid contained in the cylinder may be very hot The Cyclone Wall Hung Multipoint Water Heater should give trouble free operation, however should a problem occur, the table below should enable most faults to be identified with ease. Fault Finding should be carried out by a competent person and any replacement parts used should be authorised JOULE Cyclone Wall Hung Multipoint Water Heater spare parts. Fault Possible Cause Solution Water not heating Electrical supply fault. Thermal cut out tripped. Check electrical supply. Check cut out. If operated then reset. Check thermostat & replace if necessary. Discharge of water from pressure relief valve (continuously). Thermostat setting to low or faulty. Excessive mains water pressure. Expansion relief valve fault. Check and adjust setting if required. Replace if necessary. Check pressure from pressure reducing valve. Replace if greater than 3.5bar (51psi) Replace expansion relief valve. Discharge of water from pressure relief valve (intermittently). Discharge of water from temperature/pressure relief valve and/or water/steam from pressure relief valve Loss of pressure from expansion vessel. Thermostat and thermal cut out fault. Check and if necessary recharge expansion vessel precharge pressure. Replace combined thermostat & thermal cut out. No water flow Product incorrectly installed. Check inlet & outlet connections are correct. Check valves are installed in accordance with flow direction marks. Mains water supply not turned on. Check mains water supply is turned on. Blockage in mains water supply. Check mains water supply for obstructions. Check expansion relief valve. Check strainer in pressure reducing valve. Milky water Oxygenated water Water from a pressurised system releases oxygen bubbles when flowing. The milki- ness will disappear after a short while. Table 4 - Fault finding table Cyclone Wall Hung Multipoint Water Heater Installation Guide 23

Service Record It is recommended that your hot water system is serviced regularly and that the apprepriate Service Record s completed. Service Provider Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer s instructions. Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... Service 1 Date... Engineer Name... Company Name... Telephone No... Comments... Signature... 24 www.jouleuk.co.uk www.joule.ie

Cyclone Wall Hung Multipoint Water Heater Installation Guide 25

26 www.jouleuk.co.uk www.joule.ie

Cyclone Wall Hung Multipoint Water Heater Installation Guide 27

JOULE IE JOULE UK mail tel fax eml web Kylemore Park West, Ballyfermot, Dublin 10 +353 (1) 623 7080 +353 (1) 626 9337 info@joule.ie www.joule.ie JOULE PL mail tel fax eml web Unit 17C&D Power Road, Plantation Bus. Pk. Bromborough, Wirral, CH62 3RN +44 (0) 1513 551 094 +44 (0) 1513 568 336 info@jouleuk.co.uk www.jouleuk.co.uk mail tel fax eml web 23-200 Kraśnik, ul. Towarowa 34. +48 (0) 128811171 +48 (0) 814709046 biuro@joule-pl.pl www.joule-pl.pl JL-MP-INS-001-03-2017 28 www.jouleuk.co.uk www.joule.ie