CLS-EXP-DIM. Functional Summary. Specifications

Similar documents
Model NT20e Installation Guide

Universal Fan and Light Remote Control

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Twin Bell Digital Clock

48 TAYLOR CEILING FAN

programmable control model installation and setup guide M /11/ Hunter Fan Company

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Proliphix Thermostat Installation Guide. Release 2.0

52 BERKSHIRE CEILING FAN

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

6 Sheet Strip-Cut Shredder for Home/Office

180 Degree Ceiling Mounted Occupancy Sensors

52 CEILING FAN. Owner s Manual Models #50336, 50337

Towel Warmer MAKE EVERYDAY A SPA DAY

Towel Warmer. Luxurious warmth for towels, robes and blankets

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

ITEM # SAIL STREAM CEILING FAN MODEL #41695

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Model: SFE-ST FOR YOUR SAFETY ANSI / UL INSTALLER: DO NOT DISCARD THIS MANUAL -- LEAVE FOR HOME OWNER BUILDER BOX

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

Projection Alarm Clock USER GUIDE

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Thermometer with Wired Sensor

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

Bennett Collection. Installation Manual. Model: Matte Black Brushed Nickel Fan weight ±2 lbs: 23.8 lbs (10.8 kg)

Light Level Detector, Surface Mount 5754PE. Installation Instructions

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

MaxLite LED Round Pendant Highbay Series

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

Owner s Manual. PIR-1 IR Learner

PIR Sensor. User s Guide

DEHUMIDIFIER. User Manual 50BT, 70BT

LED RETROFIT CONVERSION KITS

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

ITEM # , CARATUK RIVER CEILING FAN MODEL #40046, 40303

Thermometer model 02059

POWERSHRED. 99Ci. Quality Office Products Since Please read these instructions before use. Do not discard: keep for future reference.

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Powerley Thermostat. Installation & Operation Guide

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Digital Refrigerator/Freezer Thermometer model 00986

Optima ZigBee Thermostat

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

User Manual. 40 Tower Fan MODEL: WFTR40W

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

ITEM # HYDRA CEILING FAN MODEL #41371

Environmental Monitoring SmartSlot Card

CONNEX Smart Thermostat CST R00

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

IMPORTANT SAFETY INFORMATION:

SC-6 Six Supervised Control Module

Contempo II LED. Installation Manual ITM. / ART Model: Brushed Nickel Weight ±2 lbs: 21.6 lbs(9.8 kg)

Restaurants IECC 2015 Solutions

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

MaxLite LED MICRO-T PANEL

SONANCE ORIGINAL SERIES MEDIUM IN-WALL SPEAKERS

MaxLite LED Vapor Tight Linear Fixture

Copyright Rollibot, LLC. All Rights Reserved USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

AERO CEILING FAN LISTED E ITEM # MODEL #E-AER52BRZ5LKRCI. Español p. 20 ATTACH YOUR RECEIPT HERE. Serial Number.

IMPORTANT SAFETY INFORMATION:

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Dimmable LED Retrofit Kit

Manual Feed Slot Opening. Wastebin. Credit Card Casters

View the expanded manual: GEN5

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Hospitality Title Solutions

SAVE THESE INSTRUCTIONS

Restaurants ASHRAE Solutions

10810 W. LITTLE YORK RD #130 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

MaxLite Polygon Linear LED Light

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

INSTALLATION MANUAL VISUAL PERFORMANCE RECTANGLE SPEAKERS. Introduction. Box Contents. Speaker Placement. Surround Speakers (5.

Comfort Air Fan with Remote Installation and Operation Manual

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

52 STRATHMERE CEILING FAN

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

100 Ft. LASER DISTANCE METER

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

F.P.O. Installation Guide. For Placement Only

PERSONAL HEATER OWNER S GUIDE

IRENE-HLK 60", 52" or 42" CEILING FAN

Owner s Manual TDS8515. Model Numbers:

Concert Breeze s Manual

PRODUCT DIAGRAM PACKAGE CONTENTS

Micro-Computer Induction Cooktop SR-1885SS

OPERATIONS MAINTENANCE MANUAL

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Humidity Monitor model 01080

Transcription:

Functional Summary The CLS-EXP-DIM enables the expansion of the Crestron ilux integrated lighting system and other Crestron lighting dimmers to support 120, 230, and 277 volt loads up to 16 amps. It allows any output channel of a compatible dimmer to dim a fully loaded circuit of incandescent, magnetic low-voltage, 2-wire dimmable fluorescent, or neon/cold cathode lighting. It is also compatible with CLW-Series 1 in-wall dimmers and most CLX-Series lighting control modules. 2 The CLS-EXP-DIM is designed for mounting to a vertical surface and can be installed in a space used for environmental air as defined in NEC Article 300.22(C). Conduit knockouts are provided on the bottom and lower sides. All connections are made via screw terminals behind the front cover. Works with Crestron ilux (CLS(I)-C6), CLW, 1 CLX Series, and GLX-DIM6 dimmers Emulates the characteristics of the dimmer that is controlling it Up to five expansion modules can be connected to a single ilux dimmer channel Supports 120, 230, and 277 volt LED; incandescent; NCC; MLV; and 2-wire dimmable fluorescent loads Can be installed in an air-handling space 3 Includes threshold adjustment for setting minimum fluorescent dimming level Built-in air gap relay at the output Mounts to a wall or above a suspended ceiling CLS-EXP-DIM Physical View Specifications CLS-EXP-DIM Specifications SPECIFICATION Load Ratings Dimmer Channels 1 Load Rating 16 amps Minimum Load 120 volts 230 volts 277 volts Load Types Maximum Modules per Dimmer Output Input Voltages Line Power Control Input Electrical Terminals CLS-EXP-DIM DETAILS 15 watts 25 watts 30 watts LED, incandescent, neon/cold cathode, magnetic low voltage, 2-wire dimmable fluorescent (Advance Mark 10 Powerline or equivalent) NOTE: For a list of compatible LED ballasts, visit www.crestron.com/ lightingcompatibility (PDF). 5 120 to 277 volts ac, 50/60 Hz 120 or 230 volts ac, 50/60 Hz, phase independent of line power and load, presents 25 watt load to the controlling device Captive screw type; Accommodates two 22 12 AWG (0.34 4.0 mm 2 ) wires Enclosure Surface mount module with (2) integral mounting flanges, galvanized steel with gray matte powder coat front panel, extruded aluminum heat sink, (4) 1/2 in (13 mm) and 3/4 in (20 mm) conduit knockouts provided on bottom and lower left and right sides Environmental Temperature Humidity Heat Dissipation Dimensions Height Width Depth Weight 32 to 104 F (0 to 40 C) 10% to 90% RH (non-condensing) 140 Btu/h at maximum load, 16 amps 8 13/16 in (224 mm) 6 3/8 in (163 mm) 3 3/16 in (81 mm) 3.34 lbs (1.52 kg) (Continued on the following page) 1. CLW-Series devices must have a dedicated neutral. 2. The CLS-EXP-DIM can only be controlled by forward-phase dimmer modules. It is not compatible with the CLX(I)-1DELV4. 3. As defined in NEC Article 300.22(C). Crestron Electronics, Inc. Installation Guide DOC. 6638F 15 Volvo Drive Rockleigh, NJ 07647 (2019574) Tel: 888.CRESTRON 05.14 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.

Crestron CLS-EXP-DIM ilux Dimmer Expansion Module CLS-EXP-DIM Specifications (Continued) SPECIFICATION Compatible Control Devices CLS(I)-C6 CLW-DIM Series CLX(I)-1DIM4 CLX-1DIM8 CLX(I)-2DIM2 CLX(I)-2DIM8 DETAILS ilux Integrated Lighting System Wall Dimmers Four Channel Dimmer Module, Single Feed Eight Channel Dimmer Module, Single Feed Two Channel Dimmer Module, Two Feeds Eight Channel Dimmer Module, Two Feeds Regulatory Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. These devices have been additionally evaluated to UL 2043, The Standard for Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces. As of the date of manufacture, the CLS-EXP-DIM has been tested and found to comply with specifications for CE marking. NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. 2 ilux Dimmer Expansion Module: CLS-EXP-DIM Installation Guide DOC. 6638F

ilux Dimmer Expansion Module Crestron CLS-EXP-DIM Application The following diagram shows several CLS-EXP-DIM modules in a typical application. CLS-EXP-DIM Modules in a Lighting Application Optional Installation Guide DOC. 6638F ilux Dimmer Expansion Module: CLS-EXP-DIM 3

Crestron CLS-EXP-DIM Physical Description This section provides information on the connectors, controls, and indicators available on the CLS-EXP-DIM. ilux Dimmer Expansion Module CLS-EXP-DIM (Cover Removed) 1 2 3 CLS-EXP-DIM Overall Dimensions 5 13/16 in (147 mm) 5 in (127 mm) Ø 3/16 in Ø (5 mm) 5 6 4 7 8 13/16 in (224 mm) 7 5/16 in (186 mm) 8 5/16 in (211 mm) 8 9 1/2 in (13 mm) 3 1/16 in (78 mm) 3 3/16 in (81 mm) Ø 1/4 in Ø (7 mm) Connectors, Controls, and Indicators # CONNECTORS, CONTROLS, AND INDICATORS DESCRIPTION 1 FLUORESCENT OFF THRESHOLD (1) Recessed screwdriveradjustable trim pot behind removable cap, adjusts minimum brightness level 2 STATUS (1) Red LED behind front panel, illuminates when load output is on 3 POWER (1) Green LED behind front panel, indicates power is applied to the HOT terminal 1 9/16 in (40 mm) 1 5/8 in (42 mm) 2 in (51 mm) 6 3/8 in (162 mm) 1 5/8 in (42 mm) 4 INPUT CTRL (1) Captive screw terminal, 1 control input from CLS(I)-C6 Series, CLW-DIM Series, 2 CLX(I)-DIM Series, GLX-DIM6, GLXX-2DIM8, or DIN-1DIM4; Presents a 25 watt load to the controlling dimmer; A maximum of five CLS-EXP-DIM modules may be connected to the controlling dimmer, which cannot be wired to control any other loads besides the CLS-EXP-DIM modules 5 INPUT NEUT (1) Captive screw terminal, neutral connection for control input (Continued on following page) 4 ilux Dimmer Expansion Module: CLS-EXP-DIM Installation Guide DOC. 6638F

ilux Dimmer Expansion Module Crestron CLS-EXP-DIM Connectors, Controls, and Indicators (Continued) # CONNECTORS, CONTROLS, AND INDICATORS DESCRIPTION 6 OUTPUT DIM OUT (1) Captive screw terminal, dimmed load output 7 OUTPUT HOT (1) Captive screw terminal, line power input 8 OUTPUT NEUT (1) Captive screw terminal, neutral connection for line power input and load 9 GROUND (1) 3-terminal chassis ground bus bar 1. Captive screw terminals accept up to two 22 to 12 AWG (0.34 to 4.0 mm 2 ) wires per terminal. 2. CLW-Series devices must have a dedicated neutral. Setup Important Notes Read before installation. Install in accordance with all local and national electrical codes. Use 75 C copper wire only. Installation The CLS-EXP-DIM can be installed vertically on a wall and can also be installed in a space used for environmental air as defined in NEC Article 300.22(C). Refer to the following diagram when installing a CLS-EXP-DIM module. Ensure proper ventilation: Install device vertically on a vertical surface. NOTE: To prevent potential heat damage to drywall, do not mount the CLS-EXP-DIM directly onto drywall. Mount a piece of 1/2 in (13 mm) thick (or thicker) plywood between the CLS-EXP-DIM and the drywall. Install device with 6 in (152 mm) of clearance from the top and bottom of the device. Hardware Hookup WARNING: RISK OF SERIOUS PERSONAL INJURY. Turn off power at the circuit breaker(s) prior to installation. Installing with power on can result in serious personal injury and damage to the device. 1. Use a #2 Phillips screwdriver to remove the cover screws and then remove the cover. Refer to the following diagram for details. Remove Cover Screws Cover Screws (x4) Module Installation Mounting Surface CLS-EXP-DIM Module Mounting Screw, #8, Qty. 4 Total (Not Supplied) 2. Depending on the module s application, select the appropriate configuration from one of the wiring diagrams that follow and connect the CLS-C6. The following wiring guidelines should be considered when wiring the device: Strip wires to 7/16 in (11 mm). Tighten terminal screws to 7 in-lbs (0.79 Nm). NOTE: Dimmers controlling one or more CLS-EXP-DIM modules must not be wired to control any other type of load. Installation Guide DOC. 6638F ilux Dimmer Expansion Module: CLS-EXP-DIM 5

Crestron CLS-EXP-DIM NOTE: While these diagrams show a CLS-C6 as the controlling source, other Crestron products such as CLW-Series wall dimmers (Cresnet and infinet ) and CLX-Series dimming modules can be used as well. Please refer to the specific dimmer s installation guide for detailed information. NOTE: When using a CLW-Series wall dimmer, the wall dimmer must be wired with a dedicated neutral wire. CLS-EXP-DIM Wiring with Dual Feeds CLS-EXP-DIM LOA D 3 LOA D 2 LOA D 1 CLS(I)-C6 Lighting HOT Loads N E U TRA L C O N T R O L N E U T R A L D IM O U T H O T N E U T R A L Dim Out ilux Dimmer Expansion Module Adjust the dimming level. 1. Remove the cap from the FLUORESCENT OFF THRESHOLD adjustment from the inside of the cover. It may be necessary to remove the cover from the CLS-EXP-DIM to remove the cap. Refer to the Hardware Hookup procedure on page 5 to remove the cover. 2. Using a flat-head screwdriver, turn the FLUORESCENT OFF THRESHOLD adjustment counter-clockwise until it stops. 3. Set the CLS-C6 so that the light output is on but is below the desired minimum level. 4. Turn the FLUORESCENT OFF THRESHOLD adjustment clockwise until the light output is at the desired minimum level. 5. Replace the cap and the cover. Multiple CLS-EXP-DIM Modules CLS-EXP-DIM CONTROL DIM OUT HOT Dim Out Lighting Loads LOAD3 LOAD2 LOAD1 CLS(I)-C6 HOT CLS-EXP-DIM CONTROL DIM OUT HOT Dim Out Lighting Loads 3. Apply power to the line or load and turn on the controlling device. The power indicator LED lights, indicating that power is supplied to the module. 4. Replace the cover and cover screws. Set the Minimum Dimming Level Certain types of loads can flicker when dimmed too low. Adjust the FLUORESCENT OFF THRESHOLD to prevent the CLS-EXP-DIM from attempting to dim the load below a certain level. NOTE: Some fluorescent ballasts may require that voltage levels be maintained above a specified minimum level to prevent premature lamp failure. Be sure to set the minimum dim level so that the minimum voltage is met at all times when the load is on. Please consult the ballast manufacturer s documentation for details. 6 ilux Dimmer Expansion Module: CLS-EXP-DIM Installation Guide DOC. 6638F

ilux Dimmer Expansion Module Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CLS-EXP-DIM Troubleshooting TROUBLE Load does not turn on. Load turns on and off, but does not dim. Lights do not dim properly. Lights are noisy when dimmed. Lights flicker when at certain dimming levels. Lights cannot be dimmed below a certain level. POSSIBLE CAUSE(S) Controller is not working. Controlling unit is either not a dimmer or has been set to nondim. Fluorescent Off Threshold has been set too high. An incompatible dimmer is being used. Unsupported load type is present. Large incandescent load is present. Some types of loads cannot be dimmed below a certain level. The Fluorescent Off Threshold has been set too high. CORRECTIVE ACTION Ensure the controller is powered on and is a compatible dimmer listed in Specifications on page 1. Verify that dimmer is compatible with the CLS-EXP-DIM (refer to Specifications on page 1). Verify that the controlling channel has not been programmed as non-dim. Refer to Set the Minimum Dimming Level on page 6. Make sure that the dimmer is one of those listed in Specifications on page 1. Refer to list of supported load types. Change load type or use CLS-EXP-DIMU. Some incandescent loads can make noise when dimmed due to the size of the filament. Try a different lamp manufacturer. Refer to Set the Minimum Dimming Level on page 6. Refer to Set the Minimum Dimming Level on page 6. Crestron CLS-EXP-DIM Further Inquiries To locate specific information or resolve questions after reviewing this guide, contact Crestron's True Blue Support at 1-888-CRESTRON [1-888-273-7876] or, for assistance within a particular geographic region, refer to the listing of Crestron worldwide offices at www.crestron.com/offices. To post a question about Crestron products, log onto Crestron s Online Help at www.crestron.com/onlinehelp. First-time users must establish a user account to fully benefit from all available features. Future Updates As Crestron improves functions, adds new features, and extends the capabilities of the CLS-EXP-DIM, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an Addendum in the Download column. Installation Guide DOC. 6638F ilux Dimmer Expansion Module: CLS-EXP-DIM 7

Crestron CLS-EXP-DIM ilux Dimmer Expansion Module Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address. 2. Products may be returned for credit, exchange or service with a Crestron Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to Crestron, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. Crestron reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA. 3. Return freight charges following repair of items under warranty shall be paid by Crestron, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser. Crestron Limited Warranty Crestron Electronics, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from Crestron, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touch screen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed. This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall Crestron be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. Crestron is not liable for any claim made by a third party or made by the purchaser for a third party. Crestron shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty. Except as expressly set forth in this warranty, Crestron makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. The specific patents that cover Crestron products are listed at patents.crestron.com. Crestron, the Crestron logo, Cresnet, ilux, and infinet are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Mark 10 Powerline is either a trademark or registered trademark of Koninklijke Philips Electronics N.V in the United States and/and other countries. NEC is either a trademark or registered trademark of National Fire Protection Association in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. This document was written by the Technical Publications department at Crestron. 2014 Crestron Electronics, Inc. 8 ilux Dimmer Expansion Module: CLS-EXP-DIM Installation Guide DOC. 6638F