Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Similar documents
Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Centrum stavebního inženýrství a.s.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

Classification report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification Report

Personal Protection Systems (PPS)

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BCTC CARPET TECHNICAL CENTRE

DELTA Classification Report

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

TFI Report Classification

Centrum stavebního inženýrství a.s.

Loss Prevention Standard

Technical evaluation of the Ningbo Longmax Electronic Co., Ltd LM-201A battery operated carbon monoxide (CO) Detector Type B to EN :2010.

Additional Reaction to Fire Classification Report

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

BS EN ISO : 2010

BS EN ISO : 2010

Standards and third party certification

Reaction to fire classification report No C

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Reaction to fire classification report No C-rev.1

Additional reaction to fire classification report No H

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

BS EN ISO : 2010

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

Analysis Report

CERTIFICATE OF APPROVAL No ME 5085

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Form: KSD-100:10 Page 1 of 3

CLASSIFICATION REPORT

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

FUNDERMAX GMBH FIRE TEST REPORT

Review of reports and data for Aero-Therm thermal reflective coating. Prepared for: Mr Craig Clement Director

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

TFI Report Reaction to fire test

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

BS 476: Part 6: 1989+A1:2009

Loss Prevention Standard

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Contact person Date Reference Page Richard Johansson P (2) Fire Research

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

BS 476: Part 6: 1989+A1:2009

BS EN : 2001 & IEC :2000

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

Agrément Certificate 92/2841 website: Product Sheet 1

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

BS 5839: Part THE CHANGES

CERTIFICATE OF FIRE APPROVAL

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

FIRE PERFORMANCE CABLE

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

MEDIUM-DENSITY HOUSING # 7. Fire safety

ENHANCED FIRE PERFORMANCE CABLE

Review Fire Test Report

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Fire Performance of external thermal insulation for walls of multistorey buildings

IMO Resolution MSC 61(67): Annex 1: Part 2

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Fire and Security Products and Services

Abrasion Resistance of Fluoropolymer and polyester Coatings

Loss Prevention Standard

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Classification of Fire Performance of Wall and Ceiling Lining Materials

Loss Prevention Standard

MULTIKWIK SEWER SYSTEMS MULTIKWIK WC PAN CONNECTORS

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

SIGMADEK, LTD. FIRE TEST REPORT

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

GUARDIAN FIRE TESTING LABORATORIES, INC.

Transcription:

Classification of reaction to fire performance in accordance with BS EN 13501-1: 2007 +A1: 2009 on Sandwich Panel, WP 50 Prepared for: Sandwich Panel Factory Jeddah Saudi Arabia 13 July 2011 0578 Page 1 of 8

1 Introduction This classification report defines the classification assigned to Sandwich Panel, WP 50 in accordance with the procedures given in BS EN 13501-1:2007+A1: 2009 1. CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN 13501-1: 2007+A1: 2009 Sponsor : Prepared for: Manufacturer: Prepared by: Sandwich Panel Factory, Jeddah, Saudi Arabia. Sandwich Panel Factory, Jeddah, Saudi Arabia. Sandwich Panel Factory, Jeddah, Saudi Arabia. BRE Global Ltd., Bucknalls Lane, Garston, Watford, WD25 9XX, England. Product name: Sandwich Panel, WP 50. Classification report No.: 271889 Issue number: 1 Date of issue: 13 July 2011 This classification report consists of seven pages and may only be used or reproduced in its entirety. Page 2 of 8

2 Details of classified product 2.1 General The product, Sandwich Panel, WP 50, is defined as a factory made rigid polyurethane foam (PUR) product according to BS EN 13165: 2008 2. 2.2 Product description The product, Sandwich Panel, WP 50, is described in section 2.2.2. 2.2.1 Traceability The test sample was supplied at the request of the test sponsor. BRE Global was not involved in the sampling process and therefore cannot comment upon the relationship between the samples supplied for test and the product supplied to market. 2.2.2 Sample details Name and address of test Sponsor Name and address of manufacturer of product Sample Description of specimens (as received) Description of specimens (Test sponsor s declaration) Sandwich Panel Factory, Jeddah, Saudi Arabia. As above. Double skin metal faced sandwich panel with off-white coated metal facings and a cream rigid foam core. The facings, which were approximately 0.5 mm and 0.6 mm thick respectively, were removed by a representative of BRE Global prior to testing. The following product information was received: Product name: Sandwich Panel. Product reference: WP 50. Skin colour: Bone White Ral 9002. Thickness of sample: 50 mm. Density: 38 42 kg/m³. Generic name: PUR Rigid Foam or PUR Panel. The following description was received: Sandwich Panel consists of polyurethane foam cover both side with pre-painted steel. No further information was received. Product/component tested PUR core of Sandwich Panel, WP 50. Sponsor s specimen ID WP 50. Type of product / component Insulation. Colour Off-white. Nominal declared thickness 50 mm. Nominal declared density 38 42 kg/m³. Face to be tested Either. Specimens Mean measured thickness 46 mm (range 44 mm 47.5 mm), including facings. Mean measured density 217 kg/m³. (range 209 kg/m³ - 226 kg/m³), including facings. Page 3 of 8

Mean measured mass per unit area 10 kg/m² (range 9.9 kg/m² - 10.1 g/m²), including facings. Mean measured thickness of core 45 mm (range 43 mm 46.5 mm), excluding facings. Mean measured density of core 39 kg/m³ (range 39 kg/m³ - 40 kg/m³), excluding facings. Note 1: This information was not supplied by the test sponsor. 3 Test reports & test results in support of classification 3.1 Test reports Name of Laboratory Name of sponsor Test reports Nos. Test method BRE Global Sandwich Panel Factory 267529 EN ISO 11925-2: 2010 3.2 Test results Test method & test number EN ISO 11925-2: 2010 Surface exposure, 30 s flame application period (BREG report 267529) EN ISO 11925-2: 2010 Edge exposure, 30 s flame application period (BREG report 267529) (-) Not applicable Parameter Fs No. 6 Continuous parameter - mean (m) Results Compliance with parameters - Compliant Flaming droplets/particles - Compliant Fs 6 - Compliant Flaming droplets/particles - Compliant Page 4 of 8

4 Classification and field of application 4.1 Reference of classification This classification has been carried out in accordance with BS EN 13501-1:2007+A1: 2009. 4.2 Classification The product Sandwich Panel, WP 50, in relation to its reaction to fire behaviour is classified: E The additional classification in relation to smoke production is: - The additional classification in relation to flaming droplets / particles is: - The format of the reaction to fire classification for construction products excluding floorings and linear pipe thermal insulation products is: Fire Behaviour Smoke Production Flaming Droplets E - s -, d - i.e. E 4.3 Field of application Reaction to fire classification: E The classification is valid for the following end-use application: i) Insulation product. and for the following product parameters: Thickness 50 mm. No variation in thickness allowed Colour Cream/off-white. No variation in colour allowed Composition PUR foam. No variation in composition allowed Density Nominal 38 42 kg/m³ ± 15%. The classification is valid for the following substrates and air gaps: i) Free standing without any product immediately behind or in front of it. Page 5 of 8

5 Limitations This classification document does not represent type approval or certification of the product. 6 Reference 1. BS EN 13501-1: 2007+A1: 2009. Fire classification of construction products and building elements. Part 1: Classification using data from reaction to fire, BSI, 389 Chiswick High Road, London, W4 4AL. 2009. 2. BS EN 13165: 2008. Thermal insulation products for buildings -= Factory made rigid polyurethane foam (PUR) products Specification, BSI, 389 Chiswick High Road, London, W4 4AL. 2008. Page 6 of 8

3. Prepared on behalf of BRE Global by Name C A Rock Position Senior Consultant Signature Approved on behalf of BRE Global by Name Position S J Howard Principal Consultant Date 13/07/11 Signature BRE Global Bucknalls Lane Watford Herts WD25 9XX T + 44 (0) 1923 664100 F + 44 (0) 1923 664910 E enquiries@breglobal.com www.breglobal.com BRE Global is not UKAS accredited to make opinions and interpretation. Any opinions and interpretations included as part of this report are clearly marked as such. 0578 This report may only be distributed in its entirety and in accordance with the terms and conditions of the contract. Test results relate only to the items tested. We have no responsibility for the design, materials, workmanship or performance of the product or items tested. This report does not constitute an approval, certification or endorsement of the product tested. This report is made on behalf of BRE Global. By receiving the report and action on it, the client accepts that no individual is personally liable in contract, tort or breach of statutory duty (including negligence). No third party has any right to rely on this report. Page 7 of 8

==============REPORT ENDS============= Page 8 of 8