BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

Similar documents
Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

BS EN : 2001 & IEC :2000

BS 476: Part 6: 1989+A1:2009

BS 476: Part 6: 1989+A1:2009

BS EN ISO : 2010

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : 2010

BS EN ISO : 2010

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Review Fire Test Report

NF X : Parts 1, 2, 3, 4 & 5

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

IMO Resolution MSC 61(67): Annex 1: Part 2

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

High Performance LSZH Fire Resistant Cable

FIRE PERFORMANCE CABLE

25 th November Title:

CERTIFICATE OF APPROVAL No ME 5085

ENHANCED FIRE PERFORMANCE CABLE

Test Report No: ICL/H17/7967

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Catalogue Telecommunication Cables INTRODUCCIÓN

Fire Test Reports for Interpon D Powder Coatings

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

FIRE RESISTANT CABLES FP200 GOLD

fire resistant cables

Telecommunication Cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

Test Report: ICL/CR15/11/087

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

FIRE RESISTANT CABLES

Test Report: ICL/H18/9039 Rev 1

Multi-Core Fire Resistant Cable

Report Number BTC 15450A

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

UV RESISTANT ACCORDING TO HD 605 RULE

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

FIRE RESISTANT CABLES FP200 GOLD

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Introduction.

Catalogue Power Cables

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

DNVGL-CP-0399 Edition March 2016

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

LSOH Flexible Cables

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Caledonian Fire resistant Coaxial Cables

DNVGL-CP-0401 Edition February 2016

Tratos Railway Cables

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Total Fire Solutions. Includes BS 8519 and the updated BS :

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

THE TRUE FIRE SURVIVAL CABLE

Single core cables with reduced wall thickness

Caledonian Flame Retardant Coaxial Cables

STANDARDS INSTALLATION. Certificate No 077m

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

TEST REPORT No

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

FIRE RESISTANT CABLES FP400

Traction Cable Radox 3 GKW

FIRE RESISTANT CABLES FP300

INTERNATIONAL STANDARD

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Lloyd s Register Type Approval System Test Specification Number 3

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Transcription:

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions WF Report Number: 147709 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl Date: 9 th August 2005

Page 2 of 8 Warringtonfire Report No. 147709 BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions Sponsored By FTC - Fabbrica Trentina Conduttori Srl Sud Tirol KabelWerke Via Pineta 21B 38068 Rovereto (TN) Italy

Page 3 of 8 CONTENTS PAGE NO. TEST DETAILS... 4 DESCRIPTION OF TEST SPECIMEN... 5 TEST RESULTS... 7 VALIDITY & SIGNATORIES... 8

Page 4 of 8 Test Details Purpose of test Scope of test To determine the performance of a specimen of a cable when it is subjected to the conditions of test specified in BS6387: 1994 "Specification for performance requirements for cables required to maintain circuit integrity under fire conditions". BS 6387: 1994 specifies methods of test for resistance to fire, resistance to fire with water and resistance to fire and mechanical shock. The specification recommends three test categories which are as follows :- Resistance to fire alone (Section D.2): Tests are carried out at: Category 650 0 C for 3 hours A 750 0 C for 3 hours B 950 0 C for 3 hours C 950 0 C for 20 minutes S Resistance to fire with water (Section D.3): W Resistance to fire and mechanical shock (Section D.4): Tests are carried out at: Category 650 0 C X 750 0 C Y 950 0 C Z At the request of the sponsor, tests in accordance with the procedures defined in Section D.2 (at a temperature of 950 C and rated voltage of 500V-rms for a period of three hours), Section D.3 and Section D.4 (at a temperature of 950 C and rated voltage of 500V-rms for a period of fifteen minutes) of the standard have been performed to determine compliance with the requirements of Categories C, W & Z. Instruction to test Provision of test specimens The tests were conducted on the 29 th & 30 th June 2005 at the request of FTC Fabbricca Trentina Conduttori S.r.l., the sponsor of the test. The specimens were supplied on 19 th June 2005 by the sponsor of the test. Warringtonfire was not involved in any selection or sampling procedure.

Page 5 of 8 Description of Test Specimen The description of the cable given below has been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. Plate 1 Detail of test specimen Product reference Eurosafe Cable function Fire systems connections Number of cores x core size 4 x 1.50 mm² Voltage rating 300 / 500 V Overall diameter 9.3 mm Solid plain annealed copper wire Conductors Cross-sectional area of each conductor 1.50 mm² Weight per unit length 13.52 kg/km Silicon rubber Colours Brown, Blue, Grey & Black Thickness 0.6 mm Density or weight per unit length 1.23 kg/dm 3 Conductor FTC Fabbrica Trentina Conuttori S.r.l. insulation The sponsor of the test has Details of flame retardant confirmed that no flame retardant additives were utilised in the production of the component Polyester Clear tape (surrounding the four conductors) Colour Transparent Thickness 12 µm Weight per unit area Details of flame retardant

Page 6 of 8 Drain wire Electrostatic screen Outer sheath Brief description of manufacturing process Solid tinned copper Cross-sectional area 0.28 mm² Weight per unit length 2.5 kg/km Aluminium / polyester laminate tape Thickness 25 µm Weight per unit area Details of flame retardant Colour reference Red Average thickness 0.9 mm Density or weight per unit area 1.48 kg/dm 3 FTC Fabbrica Trentina Conuttori S.r.l. Details of flame retardant Cable markings None The conductor wires are insulated by extrusion of a continuous silicon rubber layer, which has been high temperature cross-linked. The cores are then twisted together and then screened. The sheathing is then applied by a semi-compression extrusion process. Note 1 The sponsor was unwilling to provide this information

Page 7 of 8 Test Results Test results The test results relate only to the behaviour of the specimens of the cable under the particular conditions of test; they are not intended to be the sole criterion for assessing the potential fire hazards of the product in use. Resistance to fire alone (Section D.2, Category C) When tested in accordance with the procedures specified in Section D.2 of the standard, for a period of 3 hours at a temperature of 950 0 C and a rated voltage of 500V-rms, the cable maintained it s circuit integrity and consequently satisfied the performance requirements specified in BS 6387: 1994. Resistance to fire with water (Section D.3, Category W) When tested in accordance with the procedures specified in Section D.3 of the standard, for a period of 30 minutes at a temperature of 650 0 C and a rated voltage of 500V-rms, the cable maintained it s circuit integrity and consequently satisfied the performance requirements specified in BS 6387: 1994. Resistance to fire and mechanical shock (Section D.4, Category Z) When tested in accordance with the procedures specified in Section D.4 of the standard, for a period of 15 minutes at a temperature of 950 0 C and a rated voltage of 500V-rms, the cable maintained it s circuit integrity and consequently satisfied the performance requirements specified in BS 6387: 1994. Applicability of test result The test results relate only to the specimen of the cable in the form in which it was tested. Small differences in the composition of the product may significantly affect the performance during the test and may therefore invalidate the test results. Care should be taken to ensure that any product, which is supplied or used, is fully represented by the specimen, which was tested. Conclusion When tested in accordance with BS 6387: 1994: Section D.2, D.3 and D.4 the cable meets the criteria for Categories C, W and Z.

Page 8 of 8 Validity & Signatories The specification and interpretation of fire test methods are the subject of ongoing development and refinement. Changes in associated legislation may also occur. For these reasons it is recommended that the relevance of test reports over five years old should be considered by the user. The laboratory that issued the report will be able to offer, on behalf of the legal owner, a review of the procedures adopted for a particular test to ensure that they are consistent with current practices, and if required may endorse the test report. This report may only be reproduced in full. Extracts or abridgements shall not be published without permission of warringtonfire. Responsible Officer P Webb* Authorised P E Lythgoe* * For and on behalf of warringtonfire. Report Issued: 9 th August 2005 This version of the report has been produced from a.pdf format electronic file that has been provided by warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Warrington Fire Research Centre. The original signed paper version of this report, which includes signatures in blue ink, is the sole authentic version. Only original paper versions of this report bear authentic signatures of the responsible warringtonfire staff.