Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Similar documents
Settlement Agreement. Schedule 1: Covered Products

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007

Installation Manual Mopar Engine Compartment Upgrade Kit

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

General System Layout Sketch

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

Installation instructions

50 Disassembly and assembly Cab and its attachments

Acrylic Claw Foot Tub

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

INVERTER SPLIT - TYPE

Cater Hoses. Manufactured to BS669 PT2: /2 & 3/4 Braided Cater Hose with Lanyard - Quick Release

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

1 Exam Prep. Questions and Answers

FLEXIBLE CORRUGATED TUBE

1592P01. for liquids in piping DN

Flexible Gas Tubing. Semi-Rigid Corrugated Stainless Steel Tube System PRODUCT GUIDE.

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

M7100 Pressure Transducer

A B A B4

Kallista Bath Flip Drain

HEATING AND AIR CONDITIONING

568X, 587X, 588X Series

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

GEMINI TM DYNACONTROL TM HOSES Automatic & Manual Versions FOR DYNAMELT & DYNAMINI TM ADHESIVE APPLICATION SYSTEMS

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

TECHNICAL SERVICE GUIDE

Continental Industries STEEL COUPLINGS or FAX Visit

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

PULL-ON PEX PLUMBING SYSTEM

SERVICE MANUAL FOR MODEL RM-10

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

A DIVISION OF HOSE & TUBING CATALOG 2017

49 Danfoss Thermostat Kits Ranco Varifix Kits

Installation Instructions

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

TECHNICAL DATA. Wet 26a. February 22, 2009

Smooth Bore LPG Hose Type 321

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range:

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Notices for installation

Machine needle shut-off nozzle type-s

MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

BLASTMASTER 1600 CFM AIR DRYER

Installation Instructions Built-In Dishwasher

an ISO 9001:2015 Registered Company

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Dishwasher Installation Instructions DW 24XT/DW 24XV

Refrigeration and Air Conditioning

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation Instructions

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Compressors, Chillers & Condensers

Installation Instructions

Big-Lock Tubing. Total Solutions for Air, Vacuum and Inert Gas Systems

Spare parts list ( ) Spare parts list PUZZI 100 *USA

VACUUM VALVES AND HOSES

Dynaflex Hot melt hoses

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

Oil burners fuel unit with solenoid valve

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Acrylic Claw Foot Tub

ADDITIONAL PRODUCTS 65

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

Hose Clamps, Charge Air Cooler, Replacement page 2

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Handshower, Hose & Handshower Accessories

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF UBBER MPANY, INC. RUBBER COMPANY, INC RUBBER COMPANY, INC.

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Oil burners fuel unit with solenoid valve

Air Conditioner. user installation & manual manual. imagine the possibilities

SECTION (15820) - AIR DUCT ACCESSORIES

Installation Instructions

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Thermostatic Expansion Valves Type TR 6

General System Layout Sketch

REFRIGERATION PARTS SOLUTION

SERVICE MANUAL FOR MODEL RM-49

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Packaged Coldroom. Installation Instructions. Operating instructions

SECTION METERS AND GAGES FOR PLUMBING PIPING

MC1000 / MC1001 MANUAL. Operating and Calibration Instructions

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

DURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

SERVICE MANUAL FOR MODEL RM-26

Transcription:

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system Bulletin ACH-GB

The Air Conditioning / Refrigeration System The domestic and industrial Air Conditioning / Refrigeration Systems consist of four different phases in the gas handling: CONDENSATION, EVAPORATION, COMPRESSION, SYSTEM CONTROL. The system reliability is assured by the quality of the connections between the single components. 1 compressor to condenser, 2 condenser to evaporator, 3 evaporator to compressor, 4 compressor to control units (such as pressure switches or pressure gauges). YESTERDAY The conveying of refrigerating gases was assured by the use of copper tubes, with substantial dissatisfaction of all the main users, because of the following disadvantages: High noise level. High vibrations transmission, possible cause of failures. Long working time as all the different components had to be welded to the system (copper tubes, elbow copper connectors, mufflers, etc.). TODAY Today, thanks to the technological development reached with the thermoplastic materials, all these negativities have been removed and an excellent and long lasting answer to the system reliability has been reached. The experience gained from joint development programs together with the main Italian O.E.M. s has demonstrated considerable advantages such as: High flexibility and strength. Condenser noise reduction in comparison with the classic application (vibration damper, muffler). Strong reduction of vibrations transmission. Time saving for system construction: no welded connections (copper tubes, copper flanges, etc.). Improved system quality and reliability. The new K-LINK hose range (K-LS; K-LC; K-LCP), developed by TEHAG (O.E.M. Division of ITR S.p.A.) is the proper answer to all the requirements of the air conditioning and refrigeration market. 2 Parker Hannifin S.p.A.

K-LCP Capillary Thermoplastic Hose Hose Part-Number Inside Diameter Outside Diameter Tolerances Min. Bend. Radius Working Pressure Weight mm mm mm mm bar psi g/m 80000024 2.0 5.9 0.1 10 40 580 30 80000040 4.0 8.2 0.1 35 40 580 50 Smooth bore thermoplastic textile reinforced hose with a special anti-abrasion, heat and weather resistant black cover. For use in system connection between compressor and control units (pressure gauges, sensors, control valves). - Part-number 80000040: available both loose and assembled on required length. - Part-number 80000024: available both loose and assembled on required length. For loose K-LCP hoses (Part-Number 80000024) are available -on request- proper pliers and snips (manual cutter) to assure field crimping without any problem. Temperatures: -40 C / +130 C. For use with refrigerants R22, R404A, R407A, R410A UL 1963 Sect. 46.12 Approval K-LC Corrugated Bore Thermoplastic Hose Hose Part-Number Inside Diameter Outside Diameter Diametro Esterno Tolerances Min. Bend. Radius Working Pressure Weight inch mm mm mm mm bar psi g/m 80100210 3/4 21.4 31.5 0.2 200 40 580 310 80100280 1.1/8 28.4 38.8 0.3 250 40 580 360 80100380 1.1/2 38.8 50 0.3 300 40 580 580 Corrugated bore thermoplastic hose reinforced with a special stainless steel cover braid (INOX 304), resistant to abrasion and weathering. For use in system connection as compressor-condenser, condenser-evaporator and evaporator-compressor. Available pre-assembled on required lengths. Temperatures: -40 C / +130 C. For use with refrigerants R22, R404A, R407A, R410A 3 Parker Hannifin S.p.A.

K-LS Smooth Bore Thermoplastic Hose Hose Part-Number Inside Diameter Outside Diameter Outside Diameter Tolerances Min. Bend. Radius Working Pressure Weight inch mm mm mm mm bar psi g/m 80200060 1/4 4.4 9.7 0.1 50 40 580 80 80200080 5/16 6.5 11.9 0.1 55 40 580 100 80200100 3/8 8.5 13.9 0.15 60 40 580 120 80200130 1/2 10.5 16 0.15 80 40 580 140 80200160 5/8 13.5 19.3 0.15 150 40 580 180 80200190 3/4 17.5 23.6 0.2 200 40 580 240 Smooth bore thermoplastic textile reinforced hose with a special anti-abrasion, heat and weather resistant black cover. For use in systems connection as compressor-condenser, condenser-evaporator and evaporator-compressor. All sizes available both assembled on required lengths and loose for subsequent assembling. Temperatures: -40 C / +130 C. For use with refrigerants R22, R404A, R407A, R410A UL 1963 Sect. 46.12 Approval 4 Parker Hannifin S.p.A.

K-LS SPLIT Smooth Bore Thermoplastic Hose Hose Part-Number Inside Diameter Outside Diameter Outside Diameter Tolerances Min. Bend. Radius Working Pressure Weight inch mm mm mm mm bar psi g/m 80300060 1/4 4.4 21.7 0.10 50 40 580 80 80300100 3/8 8.5 25.9 0.15 60 40 580 120 80300130 1/2 10.5 28 0.15 80 40 580 140 80300160 5/8 13.5 31.3 0.15 150 40 580 180 80300190 3/4 17.5 35.6 0.2 200 40 580 240 Insulating cover of expanded polyethylene Temperatures: -30 C / +90 C. Fire resistance: non-inflammability Class 1. For use with refrigerants R22, R404A, R407A, R410A UL 1963 Sect. 46.12 Approval Reusable fittings for Freon hose K-link K-LINK hose part-number Nominal Diameter SAE fitting Sleeve Straight SAE insert 90 elbow insert Thread SAE J 513 2B 80000040 - DN 4 x 8,2 1/4 1/4" 81101040 81201041 81301041 7/16" 20 unf 80200060 - DN 4,4 x 9,7 1/4" 1/4" 81101060 81201061 81301061 7/16" 20 unf 80200100 - DN 8,5 X 13,9 3/8 3/8" 81101100 81201101 81301101 5/8" 18 unf 80200130 - DN 10,5 X 16 1/2" 1/2" 81101130 81201131 81301131 3/4" 16 unf 80200160 - DN 13,5 X 19,3 5/8 5/8" 81101160 81201161 81301161 7/8" 14 unf 80200190 - DN 17,5 X 23,6 3/4" 3/4" 81101190 81201191 81301191 1"+1/16" 14 uns 5 Parker Hannifin S.p.A.

REUSABLE FITTINGS for K-LS Working temperature: -30 C / +90 C Reusable fittings consist of a screw sleeve, to be fitted over the outside of the hose, and an insert, which is driven forcibly into the bore; the insert enlarges the internal diameter of the hose and compresses the wall against the inside of the sleeve, ensuring that the parts are held safely together. Instructions for hose assembling with reusable fittings The following pictures and relevant descriptions show the essential steps to be carried out for a correct hose assembling with reusable fittings: 1 Cut the hose on size using proper shears, automatic or manual cutters, etc. The cut must be perfectly square. Clean the cut surface. 2 Hold the hose and, using the proper wrench size, screw the sleeve anti-clockwise onto the cover, till the hose end is some 2/3 mm from the top of the sleeve. 3 Using two wrenches in opposition, tighten the insert clockwise fully home against the sleeve. 4 Insert the sleeve on the hose. 5 Put the insert in the sleeve. 6 The system is ready for use. 6 Parker Hannifin S.p.A.

INSTRUCTIONS FOR MANUAL ASSEMBLING OF CAPILLARY K-LCP 80000024 1 Cut the hose on size using proper shears, automatic or manual cutters. To obtain a perfect assembling, the must be perfectly square. Clean the surface, if necessary. 2 Insert the sleeve on the hose, turning the identification sign (groove) of the sleeve towards the hose side to be assembled. 3 Insert the nut on the hose. 4 Put the insert inside the hose. 5 Make the nut slide onto the external part of the insert and push the sleeve till covering the bottom of the insert. 6 Assemble the hose by positioning manual pliers on the sleeve covering its whole surface. Crimp till hand pliers open automatically. A second crimping in useful to obtain a safer assembling. Suggestions to regulate hand pliers. To be sure hand pliers are well regulated, assemble one hose and check that the average diameter of the crimped sleeve is 7,1 mm (just one of the eight diameters can be maximum 7,3 mm). If not, regulate the cam still the obtaned crimped sleeve in perfect. 7 Parker Hannifin S.p.A.

Fittings for K-LCP (part n 80000024) 71902830 Trumpet Copper Gasket 81900061 K90 81900012 Pin 81900062 Tee Nipple 81900052 Sleeve 81900098 Tee Female Nipple 81900053 Insert 81900104 180 Tee Female Nipple Quick coupling Series 5500 81900054 Nut 81900116 Insert with depressor 8 Parker Hannifin S.p.A.

Hose & Accessories Range for K-LCP (part n 80000024) The field assembling capability for the K-LCP capillary hoses is assured by a complete tool set that comprises: 81900051 Hand Player Crimper 80000024 K-LCP Capillary Thermoplastic Hose Recommended torque 15 Nm +/ 2 81900052 Sleeve 81900116 Insert with depressor 81900061 K90 81900053 Insert 81900054 Nut 81900096 Suitcase 81900012 Pin 81900062 Tee Nipple 81900104 180 Tee Female Nipple 71902830 Trumpet Copper Gasket 81900060 Snips 81900098 Tee Female Nipple 9 Parker Hannifin S.p.A.

Parker Hannifin S.p.A. Fluid Control Division Refrigeration & Air Conditioning Business Unit Via Enrico Fermi, 5 20060 Gessate (MI) Italy Tel: +39 02 95125.1 Fax: +39 02 95 38 20 51 Bulletin ACH-GB 09/04