ANSI/CSAA CS-V Video Verification Procedures for Burglar Alarms

Similar documents
Audio Verification and Notification Procedures

Personal Emergency Response (PERS) Verification and Notification Procedures

Video Verified Alarms Best Practices

Audio Verified Alarms Best Practices

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

American National Standard

AGENDA TECHNICAL COMMITTEE ON CARBON MONOXIDE DETECTION OCTOBER 7, 2010 TELECONFERENCE (10:00 A.M. ET)

ANSI/IEC American National Standard for Arc Welding Equipment Part 2: Liquid Cooling Systems

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online.

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

SECTION SECURITY TESTING AND COMMISSIONING

American National Standard for Electrical Intermediate Metal Conduit

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

SIA CP Security System Standard Features for False Alarm Reduction (Revision of ANSI/SIA CP ) PUBLIC REVIEW DRAFT

AS/NZS IEC :2015

SOUTH AFRICAN NATIONAL STANDARD

Australian Standard. Fire detection, warning, control and intercom systems Control and indicating equipment. Part 1: Fire

AS/NZS :2012. Regulatory compliance mark for electrical and electronic equipment AS/NZS :2012. Part 1: Use of the mark

NEMA Applications Guide

Australian/New Zealand Standard

PRIVATE ALARM CONTRACTOR LICENSURE EXAMINATION INFORMATION

Florida Senate SB 982 By Senator Bennett

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Narrative Reports As Regulated by 780 CMR, Section 903.0

Australian Standard. Security screen doors and security window grilles AS AS 5039

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

DIMENSIONAL STANDARD FOR 1/4" QUICK CONNECT COUPLER PLUGS AND SOCKETS FOR PORTABLE PRESSURE WASHERS

DIMENSIONAL STANDARD FOR M22 THREAD CONNECT COUPLER RECEPTACLES AND PLUG COLLARS FOR PORTABLE PRESSURE WASHERS

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

American National Standard for Portable Lithium Primary Cells and Batteries Safety Standard

DAVIS POLICE DEPARTMENT

Australian/New Zealand Standard

Thomasville Municipal Code Chapter 12 PUBLIC SAFETY

Australian/New Zealand Standard

This chapter shall be known as the "City of Bayfield Alarm Systems Ordinance."

FIRE & LIFE SAFTEY STANDARD

Authorized individuals to be notified. Include two (2) persons with access to the premises to allow emergency access.

RE: Response to #CommActUpdate White Paper No. 3 Competition Policy and the Role of the Federal Communications Commission

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

IS INTERNATIONAL STANDARD. Ergonomics - Visual danger signals - General requirements, design and testing

Australian/New Zealand Standard

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Foreword to the Third + Edition

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

ARTICLE 4-13 ALARM SYSTEMS * Division 1. Generally

Candidate APCO/CSAA ANS x: Alarm Monitoring Company to PSAP CAD External Alarm Interface Exchange

American National Standard. for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area Lighting ANSI C136.

Update of ANSI Standards for Warnings and Future Directions

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Emergency Support Function #2 Communication

Australian Standard. Fire protection for mobile and transportable equipment AS AS

GUIDANCE ON ASSESSING THE SAFETY INTEGRITY OF ELECTRICAL SUPPLY PROTECTION

PRC (I) August 9, Authored by

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018)

Call to Order Chair Jack Poole called the meeting to order at 8:00 AM on Monday, July 17, 2017.

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters

NFPA 72 Code Changes vs 2013

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

Australian/New Zealand Standard

AS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online.

Crime Central Station Burglary Alarm Systems

A guide to the changes between BS 8418:2010 and BS 8418:2015

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

Integrating & Synthesizing Data for Perimeter Security Awareness

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

INTERNATIONAL STANDARD

Chief Mark Crews gave a brief introduction regarding the Work Session and introduced Mr. Jack J. Krakeel to the Board.

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

Changes in NFPA

INTERNATIONAL STANDARD

Medical electrical equipment

National Fire Protection Association (NFPA) Fire Service Occupational Safety and Health Technical Committee Meeting March 14 15, 2012 San Diego, CA

ISO Clean Version of Revised Working Draft (N 348)

AS/NZS :2016

For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures

Australian/New Zealand Standard

AMERICAN RAILWAY ENGINEERING AND MAINTENANCE OF WAY ASSOCIATION. Communications & Signals Functional Group PROCEEDINGS

1.2. The system records images only and does not have sound capability.

Panel XTO210/610/710 GPRS

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

AS/NZS 3133:2008 AS/NZS

A basic guide to BS 8418:2015 CCTV Systems for Installers

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 1: Test methods

Transcription:

ANSI/CSAA CS-V-02-2012 Video Verification Procedures for Burglar Alarms Page 1 of 11 Last Revised: 10/7/11

Contents Foreword. 3 Acknowledgments.. 4 Introduction. 6 1 Scope 7 2 General 7 3 Definitions 7 4 Standard Procedures 9 4.1 Identification of a Video Verification System 9 4.2 Procedure for Alarm Signals Received from Systems 9 4.3 When to Use Video Verification 9 4.4 Reviewing Video... 10 4.5 Notification Call.. 10 5 Recommended Video Implementation Techniques 10 5.1 Monitoring Facilities Recommendations.. 10 5.3 Field of View 10 5.2 Premise Camera Position.. 10 5.3 Field of View. 11 Page 2 of 11 Last Revised: 10/7/11

Foreword This standards document is published by the Central Station Alarm Association (CSAA) and was developed and adopted by a consensus of industry volunteers in accordance with CSAA s standards development policies and procedures. CSAA assumes no responsibility for the use, application or misapplication of this document. Industry members using this document, particularly those having participated in its development and adoption, are considered by CSAA to have waived any right they might otherwise have had to assert claims against CSAA regarding the development process of this standard. CSAA reserves the right to revise this document at any time. Because CSAA policy requires that every standard be reviewed periodically and be revised, reaffirmed, or withdrawn, users of this document are cautioned to obtain and use the most recent edition of this standard. Current information regarding the revision level or status of this or any other CSAA standard may be obtained by contacting CSAA. Requests to modify this document are welcome at any time from any party, regardless of membership affiliation with CSAA. Such requests, which must be in writing and sent to the address set forth below, must clearly identify the document and text subject to the proposed modification and should include a draft of proposed changes with supporting comments. Such requests will be considered in accordance with CSAA's standards development policies and procedures. Written requests for interpretations of a CSAA standard will be considered in accordance with CSAA's standards development policies and procedures. While it is the practice of CSAA staff to process an interpretation request quickly, immediate responses may not be possible since it is often necessary for the appropriate standards subcommittee to review the request and develop an appropriate interpretation. Requests to modify a standard, requests for interpretations of a standard, or any other comments are welcome and may be sent to: Central Station Alarm Association, 8150 Leesburg Pike, Suite 700, Vienna, VA 22182; phone: 703-242-4670; www.csaaintl.org. This document is owned by the Central Station Alarm Association and may not be reproduced, in whole or part, without the prior written permission from CSAA. Page 3 of 11 Last Revised: 10/7/11

ACKNOWLEDGEMENTS CSAA Standards Chairman: Louis T. Fiore, L.T.Fiore, Inc. CSAA Committee Chairman: James McMullen, C.O.P.S. Monitoring CSAA Staff Administrator: Stephen P. Doyle, Executive Vice President, CSAA Company First Name Last Name A-1 Security Bud Wulforst* ADT Larry Dischert* ADT Tom Nakatani* ADT Brooke Smith* American Alarm Dick Sampson Bay Alarm Company Shane Clary Burns & Levinson, LLP Gil Breiman COPS Monitoring Jim McMullen* D3 Data David Boyce D3 Data Don St. Mary Diebold Mark Burnett Diebold Steve Ipson DMP Terry Shelton DSC Kevin Harris DSC Sascha Kylau DSC Dan Nita Emergency 24 Patrix Deveraux* Emergency 24 Kevin McCarthy Honeywell Bridget Lehmann Honeywell Jed McComber Knight Security Center Christopher Baskin Optex, Inc. Scott Simmons Oz Vision Shahar Belkin Oz Vision Avi Lupo* Oz Vision Tim Root Richard Hahn & Associates Richard Hahn Salitent Systems Per Hanssen Security Solutions Peter Orvis* Sonitrol Frank Minni Teldat Agustin Munoz Page 4 of 11 Last Revised: 10/7/11

Tyco Bernie Worst* UL Steven Schmit Vector Security Rick Simpson* Wayne Alarm Company Ralph Sevinor George Brody Rod Coles David Ella Lou Fiore John Judd Gary Kallman Mike Sheehan *Indicates active members. Page 5 of 11 Last Revised: 10/7/11

CS-V-02 Video Verification Procedures for Burglar Alarms Introduction This standard defines methods for using video as just one of many different technologies by which false dispatches can be reduced. It has been proven that verification of alarm signals regardless of the method used by a monitoring central station will considerably reduce false dispatches to municipal authorities or others responsible to take such like actions. This standard focuses on how to use video to verify alarm signals and to increase the possibility of visually identifying the source of the alarm event. While it is a goal of this standard to help in reducing the number of false dispatches; it also is a goal to provide enhanced information when available and when an alarm needs to be reported to authorities. While there are a multitude of positive applications for video surveillance, and though it may be useful in selective alarm system accounts, it is not effective in enough scenarios to use as a global dispatch reduction tool, and shall not be a requirement for police dispatch alone. The field of Video Verification is an evolving technology. It is not the intent of this standard to prohibit or limit new verification technologies or advancements provided the minimum requirements in this standard are met. Page 6 of 11 Last Revised: 10/7/11

Alarm Verification and Notification Procedures 1 Video Verification Scope This standard has been prepared under the direction of the Security Industry Standards Council (SISC) members with the participation of the Central Station Alarm Association (CSAA) members, and the Security Industry Association (SIA) members. The standard is recommended for use by alarm monitoring facilities and by State and Local governments as a minimum industry standard for good practice in the use of video for alarm monitoring applications to aid in alarm verification. New technologies and efforts to reduce false alarms through other enhanced verification techniques have led to this standard. In summation video verification shall be considered one of the methods used by the industry to enhance existing verification techniques but not as a standalone requirement in order to request police response. 2 General If differences exist between this standard and other written Special Instructions with the monitored premises; the Special Instructions shall take precedence. 3 Definitions 3.1 Alarm Verification - reference ANSI/CSAA CS-V-01 3.2 Video Verification Video Verification is the pairing of video data with alarm events generated from protected premises. This pairing may assist in determining the response protocol to be followed for the alarm event. 3.3 Standard Verification - reference ANSI/CSAA CS-V-01 3.4 Enhanced Verification - reference ANSI/CSAA CS-V-01 Page 7 of 11 Last Revised: 10/7/11

3.5 Remote Video Investigation Remote Video Investigation is the procedure where monitoring facility personnel uses a live video connection or recorded video clips, pictures, and other data to remotely view the premises as a follow up method after an alarm event has been transmitted. The viewing of video and associated information of the premises occurs after the initial alarm. In effect the facility personnel may or may not be viewing the actual activity that initiated the alarm but are reviewing the video information provided after receiving the alarm event in an attempt to observe activity that may provide information about the alarm event. This method can add information to the Alarm Verification but is not considered verifying an alarm as the video may not contain information that is captured at the time of the alarm or directly associated with the alarm event. 3.6 Captured Video Information Captured Video is associated video information aligned with the alarm event and/or identified by the monitoring facility personnel while viewing video. Examples include the following: the presence of video aligned with the alarm, the identification of a human or humans, or any other information germane to the alarm scene (broken window, smashed door, or other physical characteristics) at the time of the alarm event. 3.7 Special Instructions A written, separate document from the monitoring contract document, that specifies a specific set of instructions to be followed in the event of an alarm, between the monitored premises and the alarm/monitoring company. This may also be made available to the operator on screen automatically on activation of the alarm. 3.8 Notification Call - reference ANSI/CSAA CS-V-01 3.9 Captured Frame Video The minimum number of alarm event frames made available to the operator shall be that necessary on each alarm for a reasonable person to successfully identify the cause of the alarm. In applications in which video capture, recording and transmission cannot be assured to begin within 300 milliseconds (300msec) of the actual time of the alarm event, then at least 2 (two) frames shall Page 8 of 11 Last Revised: 10/7/11

be captured before the event, 1 (one) at the time of the event and 2 (two) after the event. The minimum amount of time of captured video shall be 5 (five) seconds. As an example if the minimums are implemented, at least 5 frames of captured video spanning five seconds starting no more than 100 milliseconds after the actual alarm event will be captured and transmitted. Alternately, in applications where the time between alarm initiation and recording of the first of the required five frames cannot be assured to be within 100 milliseconds, then 5 (five) frames would be distributed over 5 (five) seconds (1 (one) second between full frames) with two frames containing pre alarm video, the event frame being the third, and two frames of post event video 4 Standard Video Verification Procedures 4.1 Identification of a Video Verification System Each alarm signal with Video Verification shall be identified by the monitoring facility personnel that additional video information is associated with the standard alarm signal received. The use of Video Verification shall only be used to enhance other alarm verification methods. 4.2 Procedure for Alarm Signals Received from Systems In accordance with ANSI/CSAA CS-V-01 standard, unless Special Instructions exist, the monitoring facility personnel shall make contact with the protected premises for authorized identification and verification upon receiving an alarm unless the cause of the alarm can be ascertained with a degree of certainty by the operator through use of the received pre-recorded or live video. 4.3 When to Use Video Verification Video information shall be combined with other verification techniques to identify personnel or zone patterns that may verify that no emergency exists. Video information does not need to be considered in the case when an alternative method of verifying that no emergency is present supersedes the viewing of the video, such as if the initial Page 9 of 11 Last Revised: 10/7/11

contact with the protected premise finds authorized personnel at the premises and/or the person states that no emergency exists. 4.4 Reviewing Video 4.4.1 4.4.2 Video information will be reviewed by the monitoring facility prior to initiating a Notification Call if no other approved alternative method can verify that an emergency does not exist Monitoring facility personnel should spend no more than 2 minutes reviewing video information and attempt to verify. If the video feed is unavailable or not viewable, monitoring facility personnel should proceed with alternate verification methods. 4.5 Notification Call The Notification Call detail will include information that has been reviewed by the monitoring facility personnel to indicate whether or not there is Captured Video Information associated with the alarm event; to indicate information has been gathered to indicate if an emergency exists. The details shall include a statement to the effect that the protected premises does support Video Verification but either no video was associated with the alarm or the Captured Video Information did not reveal conclusive information about the alarm. 5 Video Implementation Techniques The quality of the video received shall be of a nature that a person will at a minimum, be able to decipher between a human and non-human based on the attributes of human form or any other information germane to the alarm scene (broken window, smashed door, or other physical characteristics) at the time of the alarm event. 5.1 Monitoring Facilities It is recommended that the Captured Video be transmitted and available to the monitoring facility when the alarm event is Page 10 of 11 Last Revised: 10/7/11

transmitted. The alarm event and captured video do not need to be transmitted over the same medium. The monitoring facility personnel shall have the Captured Video presented in a manner that is easily accessible. 5.2 Premises Camera Position The camera should be placed to provide a clean view of the protected area. Care should be taken to avoid Cameras that can be repositioned for other purposes (ex. Review product displays or check customer traffic). 5.3 Field of View It is required that the Captured Video field of view include the area covered by the sensor that triggered the alarm event. If the sensor is a motion sensor then the captured video shall be aligned with the motion sensors coverage area. The field of view may also be more than one camera with more than one alarm event. ANNEX: The type of camera, video transmission, placement of equipment and views provided by such video equipment may serve different needs for the consumer. If determined by the consumer that a different configuration is desired, deviation from the placement and functionalities described in this standard should not prohibit the central station from utilizing such video information in its course of performing a notification to the law enforcement agency if appropriate. Page 11 of 11 Last Revised: 10/7/11