MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Similar documents
MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

FireNET Plus Wiring Instructions

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

TECHNICAL DATA OBSOLETE

Installation, Operating and Maintenance Manual

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

STANDARD FEATURES SPECIFICATIONS

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL600ULADA. NAC Power Extender. Installation Guide

MR-2602 Two Zone Fire Alarm Control Panel

POWER SOURCES MODEL NO. DESCRIPTION PRICE

ANNUNCIATOR FIXED MODULE

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Model 4001 Series Single Channel Controller

Installation Instructions

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Commercial and Light Industrial Fire Alarm Control Panel

D7053. Installation Instructions Multiplex Input/Output Module

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

AO Annunciator Module

4 & 8-POINT ANNUNCIATORS Instruction Manual

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Addressable Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Power Supply Display Module PSDM. Installation and Operation Manual

Model 4880 Status Output Display Module Manual

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

CORNELL Emergency Response Systems

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Remote Alarm Panels Features

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

LifeAlarm Fire Alarm Controls

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

21-light Remote Annunciator. Owner s Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Alarm Panel Operating Instructions

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

INSTALLATION MANUAL DV8OOO. Software Version 1.0

Model 17A00 Expansion Enclosure

Flair 500 Series Annunciators

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Model A1600 Series Annunciator

TABLE OF CONTENTS TABLE OF CONTENTS 1

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

MS-2410BC. Conventional Fire Alarm Control Panel. Programming, Installation, Maintenance and Operating Instruction Manual

Installation and Operation Guide for the UPS-64C Power Supply with CometFlash

Application, Installation, Operation & Maintenance Manual

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Electric Release Panel Wiring Tips

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Independent Zone Control (I.Z.C.)

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Centro-Matic Automated Lubrication Systems System Controls

I TS-12 1 Y K DO WHAT THEY DON T. Model. INSTALLATION lnstrljctlons. FIRE BURGLARY lnstrumentsrn INC.

Conventional Releasing Control Panel

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Specification/ Data Sheet

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Oxygen (O2) Single-Point Gas Detection System

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

PumpSaver ISS-105 IS Super Cell Installation Guide

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Installation Manual Premier 412/816/832. Issue 10

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

CM800 Emergency Call System

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SELECT-A-HORN/STROBE SERIES

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Egress Devices for Code Compliant Access-Controlled Egress Doors

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Alarm Tone Generator Model AG17

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Transcription:

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES INDEPENDENT ZONE ANNUNCIATION WITH ZONE STATUS INDICATION EIGHT RED LEDS INDICATE ZONE STATUS SELECTABLE NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED LOOPS MEMORY FOR EACH ZONE WITH INDIVIDUAL ZONE OUTPUTS INDIVIDUAL ZONE BYPASS SWITCHES WITH BYPASS DISABLE FEATURE INDIVIDUAL ZONE OUTPUTS TO DRIVE RELAYS OR STROBE LAMPS REMOTE ZONE ANNUNCIATION CAPABILITY ADJUSTABLE DOOR AJAR TIMER OPERATES ON 12 VOLTS AC OR DC DEER PARK, NEW YORK 11729

MODEL ZA-8N ZONE OUTPUTS THE ZONE OUTPUTS ARE LIMITED TO 100 MA / ZONE CAN DRIVE STROBE LAMPS AND RELAYS REMOTE PLATE CONNECTOR USE TO CONNECT ZP-8AN REMOTE PLATE TO ZA-8N THIS OUTPUT IS LIMITED TO TWO ZP-8AN REMOTE PLATES BUZZER OFF - ON JUMPER 2 AMP POWER FUSE LED ZONE INDICATORS OFF ZONE NORMAL ON ZONE VIOLATED FLASHING ZONE BYPASSED MODEL ZP-8AN REMOTE PLATE ZONE RESET SWITCH DOOR AJAR POT ADJUSTS DOOR OPEN TIME FROM 1 SECOND TO 5 MINUTES LOOP SELECTOR SELECTS N/O, N/C OR SUPERVISED LOOPS DOOR AJAR TIMER JUMPER JUMPER TURNS TIMER ON OR OFF SPECIFICATIONS VOLTAGE INPUT: 12 VOLTS AC, USE 20 VA TRANSFORMER, 12 VOLTS DC, USE 1 AMP SUPPLY MAXIMUM CURRENT: 140 MILLIAMPERES ZONE OUTPUT CURRENT: 100 MILLIAMPERES PER ZONE REMOTE OUTPUT CURRENT: 80 MILLIAMPERES LOOPS: NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED WITH 10K RESISTOR (SUPPLIED) LOOP LENGTH: 1000 FEET TOTAL DOOR AJAR TIME RANGE: ONE SECOND TO FIVE MINUTES REMOTE ANNUNCIATOR OUTPUT: LIMITED TO TWO MODEL ZP-8AN REMOTE PLATES REMOTE ANNUNCIATOR: MODEL ZP-8AN, EIGHT RED LEDS MOUNTED ON SINGLE GANG PLATE WITH ZONE RESET AND BUZZER CABINET SIZE: 10 W x 7 H x 2 D QUALITY SECURITY EQUIPMENT SINCE 1971 19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK 1 800 645-5538 631 586-4220 FAX 631 586-6500 EMAIL: INFO@ALARMCONTROLS.COM WWW.ALARMCONTROLS.COM

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR ZONE OUTPUTS THE ZONE OUTPUTS ARE LIMITED TO 100 MA. / ZONE CAN DRIVE STROBE LAMPS AND RELAYS COMMON RELAY OUTPUT S.P.D.T. CONTACTS RATED 12A@28VDC OR 120 VAC REMOTE PLATE CONNECTOR USE TO CONNECT ZP-8AN REMOTE PLATE TO ZA-8N THIS OUTPUT IS LIMITED TO TWO ZP-8AN REMOTE PLATES BUZZER OFF - ON JUMPER TO DISABLE BUZZER MOVE JUMPER FROM ON TO OFF POSITION LED ZONE INDICATORS OFF ZONE NORMAL ON ZONE VIOLATED FLASHING ZONE BYPASSED 2 AMP POWER FUSE REPLACE WITH 2 AMPERE SLOW BLOW FUSE P/N MDL-2 DOOR AJAR TIMER JUMPER TO ACTIVATE TIMER MOVE JUMPER TO ON POSITION LOOP SELECTOR SWITCH ZONE BYPASS SWITCHES SHUNTS INDIVIDUAL ZONES ZONE RESET SWITCH RESETS ZONES THAT HAVE BEEN VOILATED DOOR AJAR POT ADJUSTS DOOR OPEN TIME FROM ONE SECOND TO FIVE MINUTES SELECTS N/O, N/C OR SUPERVISED LOOPS IMPORTANT THE ZA-8N HAS EFFECTIVE LIGHTNING PROTECTION ONLY WHEN GROUNDED ACCORDING TO THE FOLLOWING INSTRUCTIONS: CONNECT EG TERMINAL TO A COLD WATER PIPE WITH NOT LESS THAN 18GA. SOLID WIRE OR TWO CONDUCTOR 18 GA.STRANDED WIRE. DO NOT GROUND TO A GAS PIPE OR THE BUILDINGS ELECTRICAL GROUND! ZP-8AN REMOTE ANNUNCIATOR THE ZA-8AN IS A SINGLE GANG STAINLESS STEEL WALLPLATE WITH EIGHT RED LEDS, REMOTE ZONE RESET BUTTON AND AUDIBLE BUZZER THE ZP-8AN CONNECTS TO THE REMOTE PLATE CONNECTOR AND DISPLAYS ZONE STATUS 19 BRANDYWINE DRIVE, DEER PARK, NY 11729 800 645-5538 WWW.ALARMCONTROLS.COM

INSTALLATION INSTRUCTIONS MODEL ZA-8N EIGHT ZONE ANNUNCIATOR SPECIFICATIONS VOLTAGE INPUT: 12 VOLTS AC, USE 20 VA TRANSFORMER, 12 VOLTS DC, USE 1 AMP. SUPPLY MAXIMUM CURRENT: 140 MILLIAMPERES ZONE OUTPUT CURRENT: 100 MILLIAMPERES PER ZONE REMOTE OUTPUT CURRENT: 80 MILLIAMPERES LOOPS: NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED WITH 10K RESISTOR (SUPPLIED) LOOP LENGTH: 1000 FEET TOTAL EACH ZONE LOOP DOOR AJAR TIMER RANGE: ONE SECOND TO FIVE MINUTES REMOTE ANNUNCIATOR OUTPUT: LIMITED TO TWO MODEL ZP-8AN REMOTE PLATES REMOTE ANNUNCIATOR: MODEL ZP-8AN, EIGHT RED LEDS MOUNTED ON SINGLE GANG WALLPLATE WITH ZONE RESET AND BUZZER NORMALLY-OPEN LOOPS NORMALLY-CLOSED LOOPS SUPERVISED LOOPS DISABLE BYPASS FEATURE TO DISABLE ZONE BYPASSING CONNECT A S.P.S.T. SWITCH OR JUMPER TO TERMINALS 2 AND 19 FOR TECHNICAL ASSISTANCE CALL 800 645-5538

MODEL ZP-18AN FOR USE WITH MODEL ZA-8N SINGLE GANG STAINLESS STEEL PLATE EIGHT RED LEDS MOMENTARY ACTION RESET SWITCH MODEL ZP-8A REMOTE PLATE ALLOWS THE REMOTE DISPLAY OF ZONE ANNUNCIATOR STATUS AND THE CAPABILITY OF REMOTE RESET 19 BRANDYWINE DRIVE DEER PARK, NY 11729 1 631 586-4220 1 800 645-5538 WWW.ALARMCONTROLS.COM EMAIL INFO@ALARMCONTROLS.COM

ZP-18AN WIRING INSTRUCTIONS THE ZP-18AN REMOTE ANNUNCIATOR PLATE PLUGS INTO A MALE CONNECTOR LABELED REMOTE PLATE ON THE ZA-8N ZONE ANNUNCIATOR. CUT THE 12 COLORED LEADS 4 FROM THE CONNECTOR. CONNECT ADDITIONAL FIELD WIRES TO THE ZP-18A AND THE ZA-8N AS REQUIRED. BE SURE THAT THE COLORS OF THE FIELD WIRES MATCH THE CONNECTIONS ON BOTH ENDS. PLUG THE FEMALE CONNECTOR FROM THE ZP-18AN INTO THE CONNECTOR ON THE ZA-18AN. THE BROWN WIRE ON THE CONNECTOR MUST BE ON THE LEFT! DEER PARK, NY 11729 800 645-5538