TLM-8 User s Guide. Features and Description. Warranty. WATLOW TLM-8 User s Guide 1

Similar documents
DIN-A-MITE Solid-State Power Controller

EZ-ZONE PM Express Users Manual. Limit Controller

EZ-ZONE PM Express. Limit Controller

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

RE-PR3-E-27 3-Phase Panel Mount 27kW

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

WT7502 PC POWER SUPPLY SUPERVISOR. Data Sheet REV Feb. 26, 2008

EZ-ZONE PM Express Users Manual. PID Controller. 3 4 Dimensions 1/32 DIN (PM3) 15.9 mm (0.63 in) mm (4.00 in) April

MTL1000 range of signal conditioners. For reliable, high quality process communications

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Operation Manual Part-No

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Model 144H. Product Data Sheet , Rev DB February Content

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

STT 3000 Series STT250 /150 Surge Protection Device Specifications

MR3CCUHV Temperature/Defrost Control

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Reference Guide. Short-form instruction for powering on and using the Ventis Pro4 Multi-Gas Monitor and the Ventis Pro5 Multi-Gas Monitor

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

W A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS

T6984F,G Electronic Floating Control Thermostats

Three-Phase Power Conditioner. Solatron Series. Instruction Manual

vibration switch

SPECIFICATION FOR APPROVAL

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

NEW KEYS RELEASE 2018

Dräger P4000 Pressure and Leak Testing

Agilent 7696A Sample Prep WorkBench

M5800 Pressure Transducer with Rotatable Display

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

SEC Signature Process Gas Analyzer

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Model 144H. Product Data Sheet , Rev DB February Content

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

UDC100 Universal Digital Controller Specifications

ESP TECHNOLOGIES LIMITED

C-Bus Four Channel General Input Unit Installation Instructions

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

RELEASE DEVICE CONTROLS

3500/61E & 3500/67E Temperature Monitor

C-Bus Four Channel Analogue Output Unit Installation Instructions

Corning LSE 6L Digital Water Bath

Thermo-Sealer. Manual Heat Sealer. User Manual

X56 Series Photometric Detectors

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Rosemount 4500 Hygienic Pressure Transmitter. Start

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

FieldLink Cable solutions for Automation & Drives

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

CPS V Cabinet Power System

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

EXTINGUISHING AGENT RELEASE MODULE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CVS 4 TEMPLATE CUTOUT SIZE: 180mm CVS 6 TEMPLATE CUTOUT SIZE: 250mm

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Series 65 Product Guide MAN 3036

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

LC1350 Level Controller

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

ISIS SAFETY SYSTEM Installation guide

4 Channel Contact Closure SFP DIN Fiber Link System

I/A Series 716C 1/16 DIN Temperature Controller

4100U City and Relay Cards Installation Instructions

201 Series Dryers Features and Benefits...3 Dimensions...4 How to Order...5 Product Specifications...5

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Dräger QuadGard Control System

Annubar Flowmeter Series

TEC2100 Series Networked Thermostats

Interface Modules for SENTRI

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Customers must fill in and mail the warranty card in order to activate the warranty.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

SECTION AUTOMATIC TRANSFER SWITCHES

Beckhoff short profile

MODEL B2 INSTALLATION MANUAL

Transcription:

TLM-8 User s Guide Features and Description The TLM-8 is a multi-zone temperature limit switch For thermal system safety, the TLM-8 can satisfy the requirement for independent temperature monitoring The TLM-8 s alarm outputs interface with visual and audible alarm devices, or they can initiate safe shutdown of equipment The TLM-8 has the following features: Multi-channel temperature monitoring Latching alarms Isolated sensor inputs Support for various thermocouples, RTDs, and thermostats Diagnostic test mode Open-sensor fail-safe Compact and easy to install LED indicator lights Up to eight temperature zones may be monitored If any temperature exceeds a trip point, the TLM-8 generates an alarm output The alarm output may be used for safety shutdown or annunciation Alarm outputs remain active until two conditions are met in sequence: the temperature drops below the trip point and alarms are acknowledged Built-in indicator lights show power and alarm states The TLM-8 accepts up to eight thermocouple, RTD or thermostatic switch temperature sensors There are two global alarm relay outputs The TLM-8 is also available with eight channel-alarm relays in addition to the two global relay outputs If all temperatures are below the trip point, the TLM-8 s relay outputs are closed When alarms activate, the relay contacts open Watlow Controls 1241 Bundy Blvd, Winona, MN 55987 Customer Service Phone: 1-800-414-4299 Fax: 1-800-445-8992 Technical Support Phone: (507) 494-5656 Fax: (507) 452-4507 E-mail: wintechsupport@watlowcom Relays that open on alarm are consistent with fail safe designs and practices Alarms are acknowledged with an optically isolated, digital input Another isolated digital input is used for testing, by simulating alarms on all channels TLM-8 System Diagram Warranty The TLM-8 is manufactured by ISO 9001-registered processes and is backed by a three-year warranty to the first purchaser for use, providing that the units have not been misapplied Since Watlow has no control over their use, and sometimes misuse, we cannot guarantee against failure Watlow s obligations hereunder, at Watlow s option, are limited to replacement, repair, or refund of purchase price, and parts which upon examination prove to be defective within the warranty period specified This warranty does not apply to damage resulting from transportation, alteration, misuse or abuse The purchaser must use Watlow parts to maintain all listed ratings Part No 0600-2150-2000 Rev D Revised: October 2007 2004, 2007 Watlow Electric and Manufacturing Company All rights reserved WATLOW TLM-8 User s Guide 1

Mounting the TLM-8 The TLM-8 mounts directly to a panel or on a DIN rail depending on the mounting style ordered DIN Rail Mounting The TLM-8 simply snaps onto a standard 35 mm DIN rail Place the hook side of the mounting mechanisms over one of the DIN rail edges and snap the assembly over the other edge DIN Rail Removal Remove the TLM-8 from the DIN rail by placing a flat blade screw driver through the slot in the end plate, hook the blade into the snap latch and pry the snap latch away from the DIN rail edge Repeat for the other side 92 mm (361 in) Wiring Recommendations TB5 Sensor Inputs Sensor Terminals Input + - 1 1 2 2 3 4 TB6 Power and Digital 3 5 6 Inputs 4 7 8 Terminals Function 5 9 10 + - 6 11 12 Test 1 2 7 13 14 Acknowledge 3 4 8 15 16 Power 5 6 Positive Terminals Negative Terminals End View 48 mm (187 in) 20 mm (075 in) Sensor Inputs Isolated DC Power supply + _ J5 1 2 3 4 5 6 7 8 TST- ACK- V- SENSOR J6 Channel 1 Channel 2 Channel 7 Channel 8 TST ACK Power 236 mm (930 in) Input Wiring Test and Acknowledge Circuits Side View DC Power Supply The TLM-8 accepts 12 to 24VÎ (dc) power input from a class 2 power supply Test Input The test input, TST, is a level-triggered digital input It is activated after the input signal is applied for at least 1 second (filter) The input signal may be generated by a contact closure or controller output The input accepts a 5 to 30VÎ (dc) signal The circuit contains a resistor and optical isolator Mounting Hole Dimensions Panel Mounting The four mounting holes will accommodate up to 38 mm (#6) screws or bolts Test Input 2 WATLOW TLM-8 User s Guide

Acknowledge Input The acknowledge input, ACK is an edge-triggered digital input The input accepts a 5 to 30VÎ (dc) signal The circuit contains a resistor and optical isolator If you are using a push button to generate the input signal, momentary contacts are recommended because the input is edge-triggered DC Power Supply + _ User Supplied Contact TLM-8 Internal Circuit ACK+ ACK Ó WARNING: You must connect the thermocouple to the input terminal blocks correctly If the inputs are reversed, the sensor may be unable to generate an alarm This could result in a fire or other accident leading to loss of property or lives Ó CAUTION: To protect the alarm relay contacts when connected to an inductive load, use catch diodes for dc loads and snubbers on ac or dc loads For dc applications select a diode with a reverse breakdown voltage 10 times the applied voltage and forward load current Acknowledge Input Load Thermocouple and RTD Inputs Be sure to use the type of sensor that matches your TLM-8; the input type is noted on the label J1 J2 OUTPUTS CH1CH2CH3 CH4CH5CH6CH7 CH8 NOG1 NOG2 Back EMF Clamp Load Back EMF Clamp Thermostatic Switch Inputs When using thermostatic switch (thermostat) inputs, TLM-8 trip points can be set externally The TLM-8 should be configured for thermostatic switches Use normally-closed thermostats that open at or above the trip point Unused Inputs If a sensor input is not used, short the positive and negative input terminals TB1 Channel Relay Outputs Relay Output Terminals 1 1, 2 2 3, 4 3 5, 6 4 7, 8 TB2 Global Relay Outputs 5 9, 10 Global Alarm 6 11, 12 Output Terminals 7 13, 14 1 1, 2 8 15, 16 2 3, 4 Wiring Recommendations for relay outputs Ó CAUTION: To minimize the power dissipated by the internal circuits and ensure temperature accuracy, apply voltage to the ACK and TST inputs only when intending to test the TLM-8 or acknowledge alarms At other times the applied signal should be 0VÎ (dc) NOTE: To avoid interference with sensor readings, separate sensor and power wiring NOTE: This device is designed for indoor use only NOTE: Use only copper conductors for power and signals other than thermocouples NOTE: Previous versions of the TLM-8 recommended earth grounding the unit s case, but the current version does not require the case to be earth grounded NOTE: Alarm outputs and indicators are latched until the condition is corrected and the alarm is acknowledged, as long as the TLM-8 remains powered If power is cycled to the unit, it will evaluate the limits again WATLOW TLM-8 User s Guide 3

Using the TLM-8 Sensor Types Sensor types for the TLM-8 are factory configured; the type of sensor for your TLM-8 is marked on the label s Your TLM-8 has been factory configured with trip points per your specification Accuracy of a trip point is ± 5% for TLM-8s with model numbers starting with TLME For example, 5% of a 200 C trip point is 10 So a 200 C trip point would trigger between 190 and 210 C Indicator Lights J5 1 2 3 4 5 6 7 8 TST- ACK- V- SENSOR J6 Channel 1 Channel 2 Channel 7 Channel 8 Power Reading s The trip points for TLM-8s with model numbers starting with TLME are encoded in the part number To determine trip points from a part number, see the section, TLM-8 Part Numbers The trip points for TLM-8s with model numbers starting with TLMC are listed on the label Alarms and Acknowledgment When the TLM-8 is powered and there is no alarm, the alarm relay contacts are held closed When a channel s temperature exceeds the trip point or the sensor fails, that channel s indicator light is illuminated and the global alarm relay contacts open When the TLM-8 is configured with the eight, optional channel alarm relays and a channel s temperature exceeds its trip point, both the global alarm relay and the corresponding channel alarm relay open All alarms are acknowledged with the ACK input An external device provides the logic signal to the ACK input The ACK input activates on the trailing edge of the input signal The input must be high for at least 20 milliseconds; when the input signal transitions to low, alarms are acknowledged Allow up to 35 seconds after acknowledging the alarms for the relays to close Acknowledging alarms before the temperature drops below the trip point or before a failed sensor is repaired will have no effect Wait until the temperature drops below the trip point before acknowledging alarms When the alarms are successfully acknowledged, the alarm indicator lights turn off and the alarm relay contacts close Reading the Indicator Lights The alarm status of each channel is indicated by the red indicator lights adjacent to the sensor input terminal block A channel indicator light turns on when the associated channel goes into alarm If the TLM-8 is configured with channel relays, this indicator light reflects the status of the associated channel relay The indicator light will remain on until the acknowledge input, ACK, is activated after the temperature drops below the trip point Alarm Status Indicator Lights Testing the Outputs The TLM-8 TST digital input allows users to simulate excessive temperature on all channels An external device switch or controller provides the logic signal to the test, TST, input All channels go into alarm which can be easily verified by the channel indicator lights Use the following procedure to test the TLM-8: 1 Activate the TST input for at least 1 second All alarms and indicator lights should activate 2 Deactivate the TST input 3 Activate the ACK input for at least 20 milliseconds 4 Deactivate the ACK input All alarms should deactivate within 35 seconds Changing s To change a trip point on the TLM-8, obtain an RMA number from your supplier and return the TLM-8 for adjustment Maintenance Over-temperature conditions may not occur regularly To test the TLM-8 s outputs, use the procedure in the section Testing the Outputs to force the TLM-8 to simulate alarm conditions on all channels To test trip point values and other system components, use a thermocouple calibrator or other appropriate means to simulate a sensor input above the trip point The green power light indicates the TLM-8 has power 4 WATLOW TLM-8 User s Guide

Application Example In the following example, a TLM-8 monitors temperatures and provides independent safety shutdown, alarm annunciation and acknowledgment A multi-loop controller, CLS200 or MLS300, is used for primary control The TLM-8 has its own set of thermocouples to monitor temperatures independent of the controller If a temperature exceeds a trip point configured in the TLM- 8, then power to the heater is turned off by a TLM-8 controlled relay, and the System OK indicator light is turned off After the temperature drops and the cause of the alarm has been corrected, an operator acknowledges the alarm The primary controller resumes control of the loop(s) Solid-state Relay AC heater relay contacts (normally open) thermocouples CLS/MLS Multi-Loop Controller DC Power Supply Series TLM-8 Watlow Winona, Inc 1241 Bundy Blvd Winona, MN 55987 USA Declares that the following product: Declaration of Conformity Designation: Series TLM-8 Model Numbers: TLM (C, E or P)(0 6)(0 or 1)(0 9)(additional letters or numbers indicating setpoint temperatures Classification: control, Installation Category II, Pollution degree 2 Rated Voltage and Power: Control 12 to 24 VÎ (dc) 400 ma maximum Note: Use of external CE approved ELV (UL Class 2) power supply required* Meets the essential requirements of the following European Union Directives by using the relevant standards show below to indicate compliance 2004/108/EC Electromagnetic Compatibility Directive EN 61326 1997 A1:1998 Electrical equipment for measurement, control and laboratory use EMC A2:2002 requirements (Industrial Immunity, Class B Emissions) A3:2004 EN 61000-4-2 1995 A2, 2001 Electrostatic Discharge Immunity EN 61000-4-3 2002 Radiated Field Immunity EN 61000-4-4 2004 Electrical Fast-Transient / Burst Immunity EN 61000-4-5* 1995 A2, 2001 Surge Immunity EN 61000-4-6 1996 A3, 2005 Conducted Immunity EN 61000-4-11* 2004 Voltage Dips, Short Interruptions and Voltage Variations Immunity EN 61000-3-2* 2001 ED2 Harmonic Current Emissions EN 61000-3-3* 1995 A2:2002 Voltage Fluctuations and Flicker 73/23/EEC Low-Voltage Directive EN 61010-1 2001 Safety Requirements of electrical equipment for measurement, control and laboratory use Part 1: General requirements Raymond D Feller III 2002/96/EC WEEE Directive Equipment Requires Recycling Winona, Minnesota, USA Name of Authorized Representative Place of Issue TST ACK TLM-8 Thermal Limit Monitor System OK indicator light General Manager August 2007 Title of Authorized Representative Date of Issue relay coil - + DC Power Supply Signature of Authorized Representative Example Schematic Declaration of Conformity NOTE: Relay contacts are illustrated in the unpowered or alarmed state WATLOW TLM-8 User s Guide 5

Specifications Analog Inputs Sensor input channels: 8 Sensor Types and Ranges: 2-Wire 100 Ω Platinum RTD DIN curve (385): -100 to 850 C (-148 to 1,562 F) E Thermocouple: 100 to 801 C (212 to 1,474 F) K Thermocouple: 100 to 1,205 C (212 to 2,201 F) S Thermocouple: 500 to 1,711 C (932 to 3,112 F) J Thermocouple: 100 to 754 C (212 to 1,389 F) R Thermocouple: 500 to 1,720 C (932 to 3,128 F) T Thermocouple: 100 to 384 C (212 to 723 F) Thermostatic switch At actual temperatures of -100 C (-148 F) or less, nuisance alarms may occur Accuracy for trip points above 100 C (212 F): For part numbers starting with TLME, ± 5% of trip point For part numbers starting with TLMC, see below Sensor (s) Accuracy Ambient: 15 to 35ºC (59 to 95ºF) J, K, E, T, RTD ±05% of trip point and ±2ºC (32ºF) S, R ±05% of trip point and ±3ºC (54ºF) Accuracy Ambient: 0 to 60ºC (32 to 140ºF) ±05% of trip point and ±4ºC (72ºF) ±05% of trip point and ±5ºC (9ºF) Repeatability: better than 5 C (9 F) or accuracy for trip point, whichever is less Input filter: 1 second (minimum time the over-temperature condition exists before the output responds) Isolation: Common Mode: ± 10VÅ (ac) or VÎ (dc) (Input to analog common) Input-to-Input: ± 10VÅ (ac) or VÎ (dc) Input-to-Frame Ground: ± 500VÅ (ac) or VÎ (dc) ACK Input Function: alarm acknowledge Type: digital input Activation: edge triggered (on to off transition) Filter: 20 milliseconds Maximum time to reset relays: 35 seconds Maximum time signal should be held high: 5 seconds Isolation: optical Voltage and current: 5 to 30VÎ (dc); 2 ma @ 5VÎ (dc); 19 ma @ 30VÎ (dc) Impedance: 15 kω TST Input Function: test Type: digital input Activation: level triggered (signal high) Filter: must be active for 1 second for valid simulation Maximum time signal should be held high: 5 seconds Isolation: optical Voltage and current: 5 to 30VÎ (dc); 2 ma @ 5VÎ (dc); 19 ma @ 30VÎ (dc) Impedance: 15 kω Electromechanical Alarm Relays Contact arrangement: open in power-off condition Contact action: latch open in alarm condition Maximum contact rating: 1 A @ 30VÎ (dc) Indicator Lights Alarm status: 8 red Power: 1 green Dimensions Length: 236 mm (930 in) Width: 92 mm (361 in) Depth: 48 mm (187 in) DIN rail mount: add 20 mm (075 in) to depth Power Requirements Nominal voltage: 12 to 24VÎ (dc) Absolute voltage: 10 to 27VÎ (dc) Power: 32 watts Requires: Class 2 power supply Terminal Blocks Type: Removable Torque: 033 to 035 Nm (29 to 31 in-lbs) Wire Gauge: 26 to 18 AWG Environmental Operating ambient temperature: 0 to 60 C (32 to 140 F) Storage ambient temperature: -20 to 100 C (-4 to 212 F) Relative humidity: 0 to 95%, non condensing Agency Approvals / Compliance UL, cul Listed (File No E185611) Process Control Equipment UL 61010 Process Control Equipment C222 #61010-1 FM Limit Switches Non Indicating Class 3545 Supervisory Switch Class 3545 CE Low Voltage Directive (LVD) 73/23/EEC Electromagnetic Compatibility Directive (EMC) 2004/108/ EC 6 WATLOW TLM-8 User s Guide

TLM-8 Part Numbers Use the tables to determine the characteristics of your TLM-8 based on its part number Standard TLM-8 Part Number Sensor Type 0 RTD or Thermostat 1 Type E Thermocouple 2 Type J Thermocouple 3 Type K Thermocouple 4 Type R Thermocouple 5 Type S Thermocouple 6 Type T Thermocouple Alarm Relays 0 Global relays only 1 Global and 8-channel alarm relays Mounting 0 Panel 1 DIN Rail (Channels 1 through 8) (See table below) T L M E Custom TLM-8 Part Number T L M C 0-0 _ Sensor Type 0 RTD or Thermostat 1 Type E Thermocouple 2 Type J Thermocouple 3 Type K Thermocouple 4 Type R Thermocouple 5 Type S Thermocouple 6 Type T Thermocouple Alarm Relays 0 Global relays only 1 Global and 8-channel alarm relays Mounting 0 Panel 1 DIN Rail Custom Code 3-digit code assigned by factory (See label on unit for trip-point values) s RTD E Thermocouple J Thermocouple K Thermocouple R Thermocouple S Thermocouple T Thermocouple Unused Input A Unused Input A Unused Input A Unused Input A Unused Input A Unused Input A Unused Input A 103 C (217 F) B 101 C (214 F) B 100 C (212 F) B 100 C (212 F) B 501 C (934 F) B 506 C (943 F) B 100 C (212 F) B 121 C (250 F) C 202 C (396 F) C 152 C (307 F) C 150 C (302 F) C 602 C (1,116 F) C 601 C (1,114 F) C 202 C (396 F) C 151 C (304 F) D 302 C (576 F) D 202 C (396 F) D 200 C (392 F) D 708 C (1,306 F) D 700 C (1,292 F) D 291 C (556 F) D 215 C (419 F) E 403 C (756 F) E 251 C (484 F) E 252 C (486 F) E 800 C (1,472 F) E 810 C (1,490 F) E 384 C (723 F) E 324 C (615 F) F 502 C (936 F) F 302 C (576 F) F 303 C (577 F) F 903 C (1,657 F) F 902 C (1,656 F) F 404 C (759 F) G 600 C (1,112 F) G 350 C (662 F) G 353 C (667 F) G 999 C (1,830 F) G 1,005 C (1,841 F) G 478 C (892 F) H 702 C (1,296 F) H 402 C (756 F) H 401 C (754 F) H 1,100 C (2,012 F) H 1,110 C (2,030 F) H 584 C (1,083 F) I 801 C (1,474 F) I 450 C (842 F) I 455 C (851 F) I 1,206 C (2,203 F) I 1,210 C (2,210 F) I 708 C (1,306 F) J 502 C (936 F) J 504 C (939 F) J 1,306 C (2,383 F) J 1,313 C (2,395 F) J 824 C (1,515 F) K 554 C (1,027 F) K 556 C (1,033 F) K 1,410 C (2,570 F) K 1,404 C (2,559 F) K Thermostat K 600 C (1,112 F) L 603 C (1,117 F) L 1,497 C (2,727 F) L 1,500 C (2,732 F) L 653 C (1,207 F) M 651 C (1,204 F) M 1,593 C (2,899 F) M 1,600 C (2,912 F) M 704 C (1,299 F) N 701 C (1,294 F) N 1,720 C (3,128 F) N 1,711 C (3,112 F) N 754 C (1,389 F) O 753 C (1,387 F) O 807 C (1,485 F) P 851 C (1,564 F) Q 907 C (1,665 F) R 952 C (1,746 F) S 998 C (1,828 F) T 1,057 C (1,935 F) 1,101 C (2,014 F) 1,157 C (2,115 F 1,205 C (2,201 F) U V W X WATLOW TLM-8 User s Guide 7

How to Reach Us Corporate Headquarters Watlow Electric Manufacturing Company 12001 Lackland Road St Louis, MO 63146 Sales: 1-800-WATLOW2 Manufacturing Support: 1-800-4WATLOW Email: info@watlowcom Website: wwwwatlowcom From outside the USA and Canada: Tel: +1 (314) 878-4600 Fax: +1 (314) 878-6814 Latin America Watlow de México SA de CV Av Fundición No 5 Col Parques Industriales Querétaro, Qro CP-76130 Mexico Tel: +52 442 217-6235 Fax: +52 442 217-6403 Europe Watlow France SARL Immeuble Somag 16, Rue Ampère 95307 Cergy-Pontoise CEDEX France Tel: + 33 (0)1 30 73 24 25 Fax: + 33 (0)1 30 73 28 75 Email: info@watlowfr Website: wwwwatlowfr Watlow GmbH Postfach 11 65, Lauchwasenstr 1 D-76709 Kronau Germany Tel: +49 (0) 7253 9400-0 Fax: +49 (0) 7253 9400-900 Email: info@watlowde Website: wwwwatlowde Watlow Italy Srl Viale Italia 52/54 20094 Corsico MI Italy Tel: +39 024588841 Fax: +39 0245869954 Email: italyinfo@watlowcom Website: wwwwatlowit Watlow Ibérica, SLU CME - Avda de la Vía Láctea, s/n Oficina 24 28830 - San Fernando de Henares Madrid Spain Tel: +34916751292 Fax: +34916487380 Email: info@watlowes Website: wwwwatlowes Watlow Storgatan 24 302 43 Halmstad Sweden Tel: + 46 (0)35 27 11 66 Fax: +46 (0)35 27 11 67 Email: info@watlowse Website: wwwwatlowse Watlow UK Ltd Linby Industrial Estate Linby, Nottingham, NG15 8AA United Kingdom Telephone: (0) 115 964 0777 Fax: (0) 115 964 0071 Email: info@watlowcouk Website: wwwwatlowcouk From outside The United Kingdom: Tel: +44 115 964 0777 Fax: +44 115 964 0071 Asia and Pacific Watlow Singapore Pte Ltd 16 Ayer Rajah Crescent, #06-03/04, Singapore 139965 Tel: +65 6773 9488 Fax: +65 6778 0323 Email: info@watlowcomsg Website:wwwwatlowcomsg Watlow Australia Pty, Ltd 4/57 Sharps Road Tullamarine, VIC 3043 Australia Tel: +61 3 9335 6449 Fax: +61 3 9330 3566 Website: wwwwatlowcom 瓦特隆电子科技 ( 上海 ) 有限公司 ( 销售办事处 ) 上海市浦东新区张江工业园区碧波路 115 号 572 弄 22 棟 * 邮编 : 201203 电话 : 86 21 5080-0902 传真 : 86 21 5080-0906 电子邮箱 : info@watlowcn Website: wwwwatlowcn Watlow Electric Manufacturing (Shanghai) Company 115-22#, 572nd Lane, Bibo Road, Zhangjiang High-Tech Park, Shanghai, PRC 201203 People s Republic of China Tel: +86 21 5080-0902 Fax: +86 21 5080-0906 Email: info@watlowcn Website: wwwwatlowcn Watlow Korea Co, Ltd #1406, E&C Dream Tower, 46, Yangpyeongdong-3ga Yeongdeungpo-gu, Seoul 150-103 Republic of Korea Tel: +82 (2) 2628-5770 Fax: +82 (2) 2628-5771 Website: wwwwatlowcokr Watlow Malaysia Sdn Bhd No 14-3 Jalan 2/114 Kuchai Business Centre Jalan Kuchai Lama 58200 Kuala Lumpur Malaysia Tel: +60 3 7980 7741 Fax: +60 3 7980 7739 瓦特龍電機股份有限公司 80143 高雄市前金區七賢二路 189 號 10 樓之一電話 : 07-2885168 傳真 : 07-2885568 Watlow Electric Taiwan Corporation 10F-1 No189 Chi-Shen 2nd Road Kaohsiung 80143 Taiwan Tel: +886-7-2885168 Fax: +886-7-2885568 Your Authorized Watlow Distributor ワトロー ジャパン株式会社 101-0047 東京都千代田区内神田 1-14-4 四国ビル別館 9 階 Tel: 03-3518-6630 Fax: 03-3518-6632 Email: infoj@watlowcom Website: wwwwatlowcojp Watlow Japan Ltd 1-14-4 Uchikanda, Chiyoda-Ku Tokyo 101-0047 Japan Tel: +81-3-3518-6630 Fax: +81-3-3518-6632 Email: infoj@watlowcom Website: wwwwatlowcojp Revised: September 20, 2007