Selectronic Tattletale Remote Alarm Annunciators

Similar documents
SELECTRONIC TATTLETALE Remote Alarm Annunciators ST Series

Selectronic Tattletale Remote Alarm Annunciators

ST Series. SELECTRONIC TATTLETALE Remote Alarm Annunciators

STAS SERIES SELECTRONIC ALARM ANNUNCIATORS

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

ESP TECHNOLOGIES LIMITED

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

Specification/ Data Sheet

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

CM800 Emergency Call System

Addendum for STI-6406 with Dual Access Control

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

AL800ULADA. NAC Power Extender. Installation Guide

Exit Stopper. STI-6400 Series

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Exit Stopper. STI-6400 Series

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Across-the-Line SERIES MP300 Combined Manual and Automatic

MR-2602 Two Zone Fire Alarm Control Panel

CORNELL Emergency Response Systems

Door Release Power Supply

LifeAlarm Fire Alarm Controls

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Release Control Fire Alarm Systems

THE. Series 01 and 02. MG01C Package

Excel-EN Conventional Fire Control Panel

Soft Start Series MP700 Solid State, Reduced Voltage

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

Variable Frequency Drive SERIES MP800 VFD

ESSEX ENGINEERING CORPORATION

AL600ULADA. NAC Power Extender. Installation Guide

FMR Installation Instructions. Addressable Fire System Controller

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Model A1600 Series Annunciator

Fire Pump Supervision - Part 2 by Dean K. Wilson, P.E.

Technical Manual. Level Alarm Unit CARLA & WIDS

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Addressable Fire Alarm Control Panel

Premier Hazard STC Instructions

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

20 Light Remote Annunciator

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

TABLE OF CONTENTS TABLE OF CONTENTS 1

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

EVO192 v3.0 Fire and Burglary What s New

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Scully ST-15 WX. Technical Manual. Multi-Point Liquid-Level Detection System

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

AO Annunciator Module

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Tek-SAFE Area of Rescue Assistance System

Intruder alarm system Operating Instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

Operation & Maintenance Manual

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

21-light Remote Annunciator. Owner s Manual

PTE0705 Electric Fence Monitor

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CabLite Luminous Auto Light Control Installation Manual

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Control/Communicator Installation Manual

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

Doc. No Part No Rev. U * T*

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

TECHNICAL DATA OBSOLETE

INSTRUCTION MANUAL PC255O

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

LifeAlarm Fire Alarm Control Panels

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

INSTALLATION AND INSTRUCTION MANUAL

TrueAlert Multi-Candela Notification Appliances

INSTRUCTION MANUAL PC255O

1F98EZ-1421, Easy Install

AND ARCHITECT SPECIFICATIONS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

TrueAlert Notification Appliances

Transcription:

sect. 25 95046 rev. 2014/09/27 Selectronic Tattletale Remote Alarm Annunciators The ST Series Selectronic Tattletale annunciators are a simple and inexpensive answer to your remote alarm annunciator needs. These compact Tattletale annunciators announce by a flashing LED which variable malfunctioned. It may feature a pulsating Mini-Siren to audibly alert to the malfunction, which is silenced by depressing the alarm silence button. The visual signal remains in operation until the fault is corrected and the contacts are cleared. When an alarm sensor trips, the LED flashes, and if equipped, the Mini-Siren sounds. At the same time, an output circuit will activate which allows you to connect an external relay to operate a general alarm, operate a shutdown device, etc. A test push button tests all alarm LEDs. Basic models accept 8-32 VAC or 8-40 VDC input voltage. Others are available for either 12-VDC or 24- VDC input. Preprinted peel and stick nameplates for common faults are supplied with each unit. Most of the Selectronic Tattletale annunciators accept either Dimensions normally open (N.O.) or normally closed (N.C.) contacts. You can mix N.O. and N.C. contacts on the same unit. Two mounting styles are offered: a recessed panel mounting flange and a freestanding gimbal mounting. (Model STA16 is available only in flange mount). All models except STA16 have a time delay available to lock out the audible alarm on startup. These unique alarm panels have wide ranging applications and can be grouped in many configurations. ST5ASF Gimbal Mounting (G Option) ST8F and ST10ASF STA16 In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. MURPHY products and the Murphy logo are registered and/or common law trademarks of Enovation Controls, LLC. This document, including textual matter and illustrations, is copyright protected by Enovation Controls, LLC, with all rights reserved. (c) 2016 Enovation Controls, LLC. A copy of the warranty may be viewed or printed by going to http://murphybyenovationcontrols.com/warranty.

BASIC: ST5AS, ST10AS and ST5DAS Series Murphy Basic ST-Series Selectronic Tattletale annunciators are used wherever a remote alarm and annunciation is required. Typical applications are in marine pilot houses to alert the crew of problems developing in engine, gear, bilge, auxiliary power plants, etc. Repeater panels can be added for additional locations such as flybridge, on deck, galley or engineer s quarters. Each repeater panel can be acknowledged individually, or alternate wiring allows for one master control to silence all repeater panels. Other applications include power plant control rooms, building maintenance, remote drilling rigs, construction sites, agricultural and construction equipment. When a fault occurs, the contact operation causes the appropriate LED to flash and the audible Mini-Siren to pulse. At the same time, an output signal is generated, which allows an external relay to be wired to operate a general alarm such as a bell or horn. Pressing the Alarm Silent button quiets the local audible alarm and disconnects the output for the remote alarm. The flashing LED remains in operation until the fault is corrected and the contacts reset. An Alarm Silence/Test button allows you to test all LEDs. Preprinted peel and stick nameplates for common faults are supplied with each unit. 5-Points ST5ASF (flange mount) and ST5ASG (gimbal mount) Provides 5 alarm points and output for remote alarm relay Use individually or gang for multiple applications 10-Points ST10ASF (flange mount) and ST10ASG (gimbal mount) Provides 10 alarm points and output for remote alarm relay Use individually or gang for multiple applications Dual 5-Points ST5DASF (flange mount) and ST5DASG (gimbal mount) Provides two separate sets of 5 alarm points in one package. Each set of 5 points is powered separately from the other but share the same negative of the power source. Primary application is on twin engine boats. Because each set of alarm points is powered separately, if only one engine is running there is no alarm on the engine not running. Warranty A limited warranty on materials and workmanship is given with this Murphy product. A copy of the warranty may be viewed or printed by going to www.murphybyenovationcontrols.com/support/warranty.htm

FIRST OUT FAULTS: ST8 Series First Out Fault Tattletale tells you which monitored variable malfunctioned first. The fault is annunciated and locked in until reset by the operator. Applications include process monitoring such as compressors, pumps, generators, etc. Preprinted peel and stick nameplates for common faults are supplied with each unit. 8 First Out ST8F (flange mount) and ST8G (gimbal mount) Provides 8-point first out cause of shutdown Tattletale. A flashing LED indicates the cause of shutdown identified by the nameplate. Includes SPDT dry contact output rated 2 A @ 28 VDC Selectable sensor lockout for delay on start up GENERATORS: STA16 Series The STA16 is a multifunctional visual and audible 16-point alarm typically applied as a remote alarm. Its picture frame bezel allows for flush mounting into a control panel or customer supplied wall mounted pull box. Preprinted peel and stick nameplates for all common engine and generator functions allow for generic applications or for NFPA-110 Requirements. 16-Points STA16 is a 16-point annunciator for generator sets. Provides 16 points of visual and audible alarms including built-in sensing for low battery voltage and battery charger malfunction Accepts N.O. switch inputs Negative switch input

Specifications Accessories and Options TDST3-5 and TDST8-10 TDST3-5 and TD8-10 single point time delays inhibit sensor input to ST Series annunciators for 3 to 5 or 8 to 10 seconds. Compensates for momentary contact operation due to vessel movement, etc. Gimbal and Flange Mounting Kits These kits are available for change-over mounting and as service parts. They fit all LM (less mounting) configurations.

How To Order Options listed below. All configurations may not be available. Call your sales representative or Enovation Controls for more information. ST10AS F 12 Base Model ST5AS ST10AS ST5DAS ST8 STA16 Mounting LM = Less mounting kit, not available on STA16 G = Gimbal mounting kit, not available on STA16 F = Flange mounting kit Voltage ST10HC, STA110, STA16 Only 12 = 12 VDC 24 = 24 VDC Accessories and Options Part Number Description Notes TDST3-5 3-5 second time delay TDST8-10 8-10 second time delay 25700007 Gimbal mount kit 25700008 Flange mount kit Fits ST5ASLM 25700034 Gimbal mount kit 25700371 Flange mount kit Fits ST10ASLM, ST5DASLM and ST8LM