CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

Similar documents
PORTABLE FIRE EXTINGUISHERS. Fire Safety.

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual

Element C3.4 Fire Fighting Equipment

Data/ Specification Sheet

FIRE SUPPRESSION SYSTEM

Extinguishers. Commercial Industrial High rise buildings

FireFlex DUAL Double Interlock, Self-contained system

CORE Protection Fire System Specification

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

1 of 7 UNIVERSAL FIRE ENGINEERING (ALOR SETAR) SDN BHD. EN3 Water & Foam Type Fire Extinguisher. Portable Carbon Dioxide Fire Extinguisher

SAFETY THE BEST FOR YOUR EQUIPMENT

Emergency Response Procedures Contractors Instruction. Building nformation

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Inert Gas Fire Extinguishing System

Certificate of Conformity Certificate num. Registration date Version Valid until

Conventional Fire Detection


Fire fighting Questions

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Specification/ Data Sheet

CO2 COCO GAS FLOODING SYSTEM

Twin-Agent Fire Fighting/Securing Systems Specifications

PROFESSIONAL SUPPLIER

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Carbon Dioxide Fire Suppression Systems

Agent Tanks PCL PCL PCL PCL - 600

Certificate of Conformity Certificate num. Registration date Version Valid until

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

CARBON DIOXIDE CO 2 Industrial fire suppression systems

Institute for Plasma Research Welcomes you all on

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

w w a. m o c. x e r fi. w u

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

manufacturer since 1984

CO2 High Pressure Extinguishing System

MODULE 2. Water-Based Suppression System Basics

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

TotalPac X Single interlock SUREFIRE system

Xenex Conventional Fire Detection & Alarm System

CO 2 EXTINGUISHING SYSTEMS

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

Risk Management Department. Fire Extinguishers

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Safe, Effective, Environment-friendly

Deluge & Preac tion Systems

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

The complete conventional fire warning system

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Hospitals and Major Medical Centers

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

GUILFORD COUNTY SCHOOLS

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

PriceList Category PartNbr Part Description Weight (l MSRP

Welcome to Argonite fire protection from Ginge-Kerr

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

SPECIFICATION: ARGONITE Engineered Fire Suppression System

TotalPac X Firecycle III Preaction Double interlock system

mirage standard response concealed pendent sprinkler vk492 (K5.6)

Excel-EN Conventional Fire Control Panel

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

LF-4000 Series Conventional Fire Alarm Control Unit

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Sita200plus. 200detectors. Single loop analogue addressable System

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

PART 1 - GENERAL 1.1 WORK INCLUDED

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

CO 2 Fire Extinguishing Systems

EFBW series - BiWire Ultra control panel

Packed With Features. Smart Pulsar controls are conveniently

High Quality LED Lighting!

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Fire Extinguisher Training

Air. Pressure. Motion. nnnnnnnn

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

Installation and user manual for the BiWire / Conventional Repeater Panel

Worldwide Contacts.

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

DETECT-A-FIRE Heat Detectors

Transcription:

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM Carbon dioxide (CO) is a well-known extinguishing system for electrical equipment. The system consists of liquefied CO stored in pressurised cylinder, discharge valves, piping and electrical devices that automatically detect smoke or heat and quickly discharge the CO in the cylinders to extinguish the fire.

A carbon dioxide (CO) fire extinguishing system works by displaces the oxygen that supports combustion. It is applied by the total flooding principle with CO and hold until the combustion stops. A total flooding application can be defined as injecting CO into an enclosure or volume having the structural integrity to retain the agent during and after discharge. This system operated automatically by or manually by the operation of a system actuator. CO Features Leaves no residue after discharge Eco-friendly agent Non-damaging to property Effective on a wide range of flammable and combustible materials. CO Applications Electrical Room Generator Room Switch Room 9 S 8 10 11 1 H 7 H 6 5 4 1 S 3 CO Typical Arrangement 1. Electric Solenoid Pilot Cylinder (550 psi). 68L Carbon Dioxide Cyclinder 3. Manifold 4. Smoke Detector 5. Fire Curtain 6. 4V DC Tripping Device 7. Heat Detector 8. CO Discharge Nozzle 9. Twin Flasing Light 10. Fire Alarm Bell 11. CO Control Panel 1. Manual Pull Station SIDE ELEVATION TYPICAL CO PILOT CYLINDER ARRANGMENT 14 13 1 Flexible 16 9 10 11 6 5 4 3 1 15-8 7 FRONT ELEVATION TYPICAL CO PILOT CYLINDER ARRANGMENT 17 Discharge 18 19 0 Connecting 1 38

Nett Volume CO Capacity Working Pressure Test Pressure Empty Weight Manufactured CYL-N 68L 45kg 150 bar 5 bar 75kg Mn Steel DOT-3AA BS 5045 Part 1 Gas Stored Pressure Power PC-S, PC-T Nitrogen 38 bar (550 psi) 4 V DC Type Mode Working Pressure Type Weight of Valve Standard 45KG-NV Forged Brass CuZn 3963 UP-05 150bar Manual/Pneumatic/Electric 700g DIN 477 39

Lenght Type Test Pressure HH-CH-13 6mm (1/4 ) 330mm (13 ) High Pressure Hose Steel Braided Rubber Hose 150 bar Discharge Hose 3 Lenght Type Test Pressure HH-DH-17 13mm(1/ ) 43mm(17 ) High Pressure Hose Steel Braided Rubber Hose 150 bar Discharge Pattern Discharge Type DN-UH15 DN-UH0 DN-UH5 15mm 0mm 5mm Brass Chrome Uni-bilateral With Orifice Pendent 45KG-PC Steel Galvanised 40

HHF-VP-3/8 10mm(3/8 ) Steel Galvanised HHF-TEE-1/ 13mm (1/ ) x 13mm(1/ ) x 6mm(1/4 ) Steel Galvanised HHF-PG-3/8 10mm(3/8 ) Steel Galvanised TD 180mm(W) x 90mm(D) x 40mm(H) Working Current 0.4A Aluminum Alloy Red Polyester 41

Smoke Curtain Colour Coating Finish Operating Temperature Standard FC Woven Fibreglass Fabric White Loomstate Basic Fabric 600 C BS 476: Part 7 MPB Ø00mm x 65mm(H) Aluminum Alloy Red Polyester SIZE No. of Zones Model no. Code no. (mm) (W x D x H) Normal Weatherproof PE-HP000 FAP-0ZCP-N 430 x 195 x 370 435 x 195 x 410 4 PE-HP4000 Power Supply Input Operating Charger Charging Rate STANDBY MODE Master Per zone (with detectors) Flashing Lights (Red LED) ALARM MODE Master Per Trigger Zone Output Devices Flashing Lights (Red LED) Per Bell FAP-04ZCP-N 55 x 178 x 380 540 x 178 x 40 40V AC 50Hz 4V DC Automatic/Trickle Type 300mA (Trickle).5A (Boost) 75mA 5mA 75mA 10mA 70mA 100mA 75mA 30mA 4

UNIQUE Smoke Detector Model No. Description Alarm Current @ 4V DC 470 Ω AH0711 FAE-P0711 Wire 40mA Operating Temperature Range Operating Humidity Range Voltage Range Standby Current Sensitivity Setting Weight Colour -10 C to 55 C 10% to 93% Relative Humidity 1V-30V DC 5-75 µa Complies with UL 68 Fire- proof plastic Ø10mm x 47mm (H) 130g White EFFECTIVE ALERT AREA Building Height Under 4m 4m to 0m Area Covered 150m 75m UNIQUE Heat Detector 45 Model No. Description Alarm Current @ 4V DC 470 Ω Operating Temperature Range Operating Humidity Range Voltage Range Standby Current Sensitivity Setting Weight Colour EFFECTIVE ALERT AREA Building Height Under 4m 4m to 8m AH0333 FAE-H0333 Wire 40mA 0 C to 55 C 10% to 93% Relative Humidity 1V-30V DC 5-75 µa Complies with UL 68 Fire- proof plastic Ø111mm x 45mm (H) 137g White Fire Proof Building Ordinary Building 90m 50m 45m 30m 43

Model No. Lens Luminary (Casing & Hood) Weight KP305B (BULB), KP305L (LED) FAE-FLO-BU, FAE-FLO-LED High efficient prismatic polycarbonate lens optimized for omnidirectional viewing. Filament Bulb/Ultra Bright LED 10mm(W) x 77mm(D) x 108mm(H) Mild Steel Epoxy Powder Red Black casing with green and red lens UNIQUE Fire Alarm Bell Model No. Supply Voltage Sound Output Current Consumption D10 FAE-6AB 110/ 40V (AC) 1/4V (DC) 9-105 db 0.05 A 150mm(6 ) Red 44