PEPPERL+FUCHS GmbH

Similar documents
Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Inductive slot sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

OPTIBAR P 1010/2010 C Supplementary instructions

EU DECLARATION OF CONFORMITY

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

OPTIBAR DP 7060 Supplementary Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

SEK-3 Marine Grounding System

VERSAFLOW VORTEX Supplementary instructions

Operating Instructions Edition 02/2007

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

4) Intrinsic Safety Certification

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

AND INSTALLATION MANUAL

Annubar Flowmeter Series

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

OilSET-1000 (12 VDC)

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Gas cylinder scale Model GCS-1

Temperature Measurement Transmitters for field mounting


SET-2000 Hi Level/Oil

DB5 Intrinsically Safe Sounder Type DB-5

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

IECEx Certificate of Conformity

SET Installation and Operating Instructions. Level switch for one sensor

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Installation and Operating Instruction

RT FLOW RATE TOTALISER

Translation of the assembly instructions with operating instructions and technical appendix

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Fire & Security Products. Siemens Building Technologies Group

Safety instructions VEGAPULS 64

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

INSTRUCTION MANUAL (ATEX / IECEx)

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Instrumentation Products and Applications

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Ultrasonic Level Measurement nivopuls FDU 10 S

Model 144H. Product Data Sheet , Rev DB February Content

INSTRUCTION & SERVICE MANUAL

Manual Power relay SR853

Supplementary Installation and Operating Instructions. Category II2G

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Model 144H. Product Data Sheet , Rev DB February Content

SET-2000 Oil/Sludge 12 VDC

Rotameter series 250 metal tube variable area flowmeter

Operating Manual MS220Vi and MSR220Vi

Dual certification! Air handling units for potentially explosive atmospheres

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

DICTATOR Hold-Open Systems for Hazardous Areas

MANUAL Oil Level Sensor

IECEx Certificate of Conformity

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Intrinsically Safe Solutions

Rosemount 752 Fieldbus Remote Indicator

Multipoint temperature sensor

IECEx Certificate of Conformity

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Guide for hazardous areas

End of Life -Discussion on Ex Luminaires for Fluorescent Lamps in Zone 1? Not a Problem for Us! EVG 05

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Certificate of Compliance

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Transcription:

Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction factor r Al 0,22 Reduction factor r Cu 0,19 Reduction factor r V2A 0,65 Nominal voltage U o 8 V Switching frequency f 0... 5000 Hz Hysteresis H 1... 10 typ. 3 % Reverse polarity protection Protected against reverse polarity Short circuit protection yes Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Indication of the switching state LED, yellow EMC in accordance with EN 60947-5-2; NE 21 Standards DIN EN 60947-5-6 (NAMUR) Ambient temperature -25... 100 C (248... 373 K) Storage temperature -40... 100 C (233... 373 K) Connection type 2 m, PVC cable Core cross-section 0.14 mm² Housing material high grade steel Sensing face PBT Protection degree IP67 Use in the hazardous area see instruction manuals Category 1G, 2G, 3G, 1D, 3D 2003-12-18 106278_ENG.xml Connection_type: N/N0 I 1/BN 2/BU L+ L- 1

Device category 1G BR for use in hazardous areas with gas, vapour and mist Standard conformity EN 50014:1997; EN 50020:1994; EN 50284:1999 Ignition protection "Intrinsic safety" EC-Type Examination Certificate Assigned type Cable length Explosion group IIA Explosion group IIB Explosion group IIC Highest permissible ambient temperature II 1G EEx ia IIC T6 PTB 00 ATEX 2048 X NCB1,5...M...N0... 100 µh ; a cable length of 10 m is considered. Dangerous electrostatic charges on the fixed connection cable must be taken into account for lengths equal to and exceeding the following values: 147 cm 73 cm 11 cm The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EU prototype test certificate must be observed. The special conditions must be adhered to! The temperature ranges, according to temperature class, are given in the EU prototype test certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. charges on the mechanical housing components can be avoided by incorporating these in the equipotential 2

Device category 2G for use in hazardous areas with gas, vapour and mist Standard conformity EN 50014:1997, EN 50020:1994 Ignition protection "Intrinsic safety" EC-Type Examination Certificate Assigned type Highest permissible ambient temperature II 1G EEx ia IIC T6 PTB 00 ATEX 2048 X NCB1,5...M...N0... 100 µh ; a cable length of 10 m is considered. manual. The EU prototype test certificate must be observed. The special conditions must be adhered to! The temperature ranges, according to temperature class, are given in the EU prototype test certificate. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. 3

Device category 3G (na) for use in hazardous areas with gas, vapour and mist Standard conformity EN 50021:2000 Ignition protection category "n" Minimum series resistance RV Maximum operating voltage UBmax Maximum permissible ambient temperature T Umax II 3G EEx na IIC T6 X manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 59 C using an amplifier in accordance with 59 C EN 60947-5-6 The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light Protection of the connection cable The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. The connection cable must be prevented from being subjected to tension and torsional loading. 4

Device category 3G (nl) Standard conformity for use in hazardous areas with gas, vapour and mist EN 50021:2000 Ignition protection category "n" II 3G EEx nl IIC T6 X 100 µh ; A cable length of 10 m is considered. for Pi=34 mw, Ii=25 ma, T6 70 C for Pi=34 mw, Ii=25 ma, T5 85 C for Pi=34 mw, Ii=25 ma, T4-T1 100 C for Pi=64 mw, Ii=25 ma, T6 69 C for Pi=64 mw, Ii=25 ma, T5 84 C for Pi=64 mw, Ii=25 ma, T4-T1 100 C for Pi=169 mw, Ii=52 ma, T6 51 C for Pi=169 mw, Ii=52 ma, T5 66 C for Pi=169 mw, Ii=52 ma, T4-T1 85 C for Pi=242 mw, Ii=76 ma, T6 39 C for Pi=242 mw, Ii=76 ma, T5 54 C for Pi=242 mw, Ii=76 ma, T4-T1 67 C Connection parts manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! The sensor must only be operated with an energy-limited circuit, which satisfies the requirements of IEC 60079-15. The explosion group complies with the connected, supplying, power limiting circuit. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 5

Device category 1D Standard conformity for use in hazardous areas with combustible dust IEC 61241-11:2002: draft; pren61241-0:2002 type of protection intrinsic safety "id" II 1D Ex iad 20 T 108 C EC-Type Examination Certificate Assigned type Maximum housing surface temperature ZELM 03 ATEX 0128 X NCB1,5...M...N0... 100 µh ; a cable length of 10 m is considered. manual. The EU prototype test certificate must be observed. The special conditions must be adhered to! The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iad. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. 6

Device category 3D for use in hazardous areas with non-conducting combustible dust Standard conformity EN 50281-1-1 Protection via housing [Fett] Minimum series resistance RV II 3D IP67 T 111 C X manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage UBmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 11 C using an amplifier in accordance with 11 C EN 60947-5-6 Protection of the connection cable The connection cable must be prevented from being subjected to tension and torsional loading. 7