Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Similar documents
Electron Microscopy Sciences

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Explosion-proof Duct Heaters

FACT SHEET Program: Lab Fire Safety

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Explosion Proof Speaker, Ringer & Speaker/Ringer

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

VSD AND SS DRIVING ATEX MOTORS February 2014

ESD3000IR ESD3000IR. Infrared Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector

Flammable and Combustible Liquids: Storage and Handling

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

ESD3000 ESD200 Combustible / Toxic Gas Detector

Explosion Proof Speaker, Ringer & Speaker/Ringer

WATER BATH BM100 BM200

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

1. GENERAL TECHNICAL INFORMATION

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

Flammable and Combustible Liquids Checklist

Star Teck. Teck and Tray Cable Fittings. Table of Contents

Fire Alarm System Accessories

Explosion protection Marijan Gorše, dipl. ing.

Thermo Scientific Flammable Material and Explosion-Proof Refrigerators and Freezers. Safe cold storage for Hazardous material

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Hazardous area descriptions

Thermo Scientific Precision Ovens

Dräger PEX 3000 Flammable Gas Detection

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Working safely with flammable liquids

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Heto PowerDry LL1500 Freeze Dryer

Fire Alarm System Accessories

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Isotemp Hotplates, Stirrers and Stirring Hotplates

Dräger Polytron SE Ex Fixed Gas Detector

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Flameproof Type Light Curtain Type 4

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

LFL Monitoring. MEGTEC Systems

MERIDIAN UNIVERSAL GAS DETECTOR

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Combustible Gas Detection and Control System

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR EPH-FH SERIES HEATER

StableTemp Hotplates, Stirrers and Stirring Hotplates

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Specifying Temperature Sensors for Hazardous Areas

Relays for use in hazardous locations. Class I, Division 2 and ATEX

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

Guide for hazardous areas

APPLICATION DATA SHEET

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

SBS-H2 Hydrogen Gas Detector Kit

Explosion-protected actuator Page 259 of 292

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

Implementation of ATEX Guidelines

Thank You for Attending Today s Webinar:

Organic Solvent Recovery Unit RT200. Instruction Manual. - First Edition -

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

Cimarec Stirring Hot Plates

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

ROTARY EVAPORATOR RE400

Description. Applications

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Thermo Scientific 1300 Series A2

CLASS I LOCATIONS ZONE CLASSIFICATION

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Installation and Wiring 1.

Brasch Hazardous Location Unit Heaters

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SUPER-NUOVA Digital Plates

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers

Corning LSE Benchtop Shaking Incubator

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

HOT PLATE OPERATION MANUAL AND PARTS LIST Series 64

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s

S T R I T T & P R I E B E I N C.

CC28. Operation Manual. Transmitter for flammable gases and vapours

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

ATEX Safety Switches. More than safety.

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance

Introduction to Hazardous Electrical Location Classifications

Transcription:

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and D Hazardous Locations Model # Voltage Description SP87325 120 9.13 X 9.13 (23.2 cm X 23.2 cm) Aluminum Top SP87324 100 9.13 X 9.13 (23.2 cm X 23.2 cm) Aluminum Top U.S. Patent No. 5,834,739 LT873X1 12/29/10 Serial Number 1

Table of Contents Safety Information...3 Alert Signals...3 Warnings...3 Summary of Hazardous Atmospheres...4 Introduction...5 Intended Use...5 General Usage...5 Principles of Operation...5 General Specifications...6 Installation...7 Site Selection...7 Operation...8 Heating Specifications...8 Setting the Temperature...9 Use of Dial Thermometer...9 Heating Metal Vessels...9 Heat-up Time Guide...10 Stirring Speed Specifications...10 Setting the Stirring Speed...10 Stirring Speed Guide...11 Maintenance and Servicing...12 Ordering Procedures...13 Warranty...16 2

SAFETY INFORMATION Summary of Hazardous Atmospheres Chemicals/atmospheres designated as Class I, Group C and Group D in accordance with the National Electric Code, National Fire Protection Association (NFPA 70).* * Not a complete list. For a more complete list of flammable chemicals, see classification of gases, vapors, and dusts for electrical equipment in hazardous (classified) locations, NFPA 497. 4 Warning To reduce the risk of fire or explosion, do not operate or install the SAFE-T SHP9 where the marked operating temperature (T2A, 280 C) exceeds the ignition temperatures of the chemical vapors/hazardous atmospheres present. GROUP CHEMICAL/ATMOSPHERE IGNITION TEMPERATURES C Acetaldehyde 175 C, 347 F C Diethyl Ether 160 C, 320 F C Ethylene 450 C, 842 F C Unsymmetrical Dimethyl Hydrazine (UDMH) 249 C, 480 F D Acetone 465 C, 869 F D Acrylonitrile 481 C, 898 F D Ammonia 498 C, 928 F D Benzene 498 C, 928 F D Butane 288 C, 550 F D 1-Butanol 343 C, 650 F D 2-Butanol 405 C, 761 F D n-butyl Acetate 421 C, 790 F D Cyclopropane 503 C, 938 F D Ethane 472 C, 882 F D Ethanol 363 C, 685 F D Ethyl Acetate 427 C, 800 F D Ethylene Dichloride 413 C, 775 F D Gasoline 280-471 C, 536-880 F D Heptane 204 C, 399 F D Hexane 225 C, 437 F D Isoamyl Alcohol 350 C, 662 F D Isoprene 220 C, 428 F D Methane (Natural Gas) 630 C, 999 F D Methanol 385 C, 725 F D Methyl Ethyl Ketone 404 C, 759 F D Methyl Isobutyl Ketone 440 C, 840 F D 2-Methyl-1-Propanol 416 C, 780 F D 2-Methyl-2-Propanol 478 C, 892 F D Naptha (Petroleum Naptha) 288 C, 550 F D Pyridine 482 C, 900 F D Octane 206 C, 403 F D Pentane 243 C, 470 F D 1-Pentanol 300 C, 572 F D Propane 450 C, 842 F D 1-Propanol 413 C, 775 F D 2-Propanol 399 C, 750 F D Propylene 455 C, 851 F D Styrene 490 C, 914 F D Toluene 480 C, 896 F D Vinyl Acetate 402 C, 756 F D Vinyl Chloride 472 C, 882 F D Xylenes 464-529 C, 867-984 F

Introduction Note The Type SP87300 SAFE-T SHP9 Stirring Hot Plate is UL listed explosionproof for Class I, Division I, Group C and D locations where flammable gases or vapors are present in sufficient quantities to produce explosive or ignitable mixtures. The Group C and D classification specifies hazardous atmospheres containing either flammable gases or vapors of flammable liquids (see NFPA 497 and NFPA 321). Intended Use The Type SP87300 SAFE-T SHP9 Stirring Hot Plate is UL listed and has been designed to meet OSHA and other safety standards. It is used for procedures requiring temperatures from 100 F (38 C) to 424 F (218 C). The unit consists of 1) a heated aluminum top plate, 2) an adjustable electronic temperature control and 3) an adjustable electronic stirring speed control. See Figure 1 for the shape and general features of the unit. General Usage Do not use this product for anything other than its intended usage. Principles of Operation The top plate is heated by a tubular heating element cast into an aluminum top plate. The temperature of the plate is controlled by a primary electronic feedback control. The primary electronic control serves to limit the top plate temperature under normal operating conditions. A secondary bimetallic thermostat is installed as a safety feature to control the temperature should the primary electronic control fail. The secondary control will limit the top plate temperature to 280 C (536 F). The stirring speed on a SAFE-T SHP9 is controlled by an electronic control. The stirring motor located in an explosion-proof enclosure is combined with a powerful magnet to provide excellent coupling with a stir bar. All control and electrical connections are contained within the aluminum explosion-proof enclosure. Temperature monitoring is provided by inserting a thermometer in the top plate well. (The thermometer is optional part # MEX126.) 5

Note: Max Temp. is the Temp. at the center of top plate.

Installation Caution The wooden shipping support attached to the bottom of the SAFE-T SHP9 stirring hot plate must be removed prior to permanent field installation. Caution Minimum allowable spacing between stirring hot plate and any vertical surface is one inch (2.54 cm). Caution To reduce the risk of fire or explosion, do not install where the marked operating temperature exceeds the ignition temperature of the hazardous atmosphere(s). Warning To avoid electrical shock this stirring hot plate must be installed by a competent, qualified electrician who is familiar with installing explosion-proof electrical equipment and ensures compatibility among the stirring hot plate specifications, power source and grounding requirements. Grounding requirements for hazardous areas are specified in Article 501 (and Article 250) of the National Electrical Code. Consult local electrical code requirements also. All units are provided with an equipment grounding lead that should be used as the primary equipment ground connection for the unit. Site Selection Install the SAFE-T SHP9 Stirring Hot Plate on a level, sturdy surface and allow space for ventilation. The electrical specifications are located on the back of the stirring hot plate. Consult customer service if your electrical service is different than that listed on the specification plate. Your SAFE-T SHP9 Stirring Hot Plate is designed for permanent installation. Permanent installation is made possible with integral mounting lugs and 1/2 (1.3 cm) conduit with 18 (45.7 cm) of lead wire provided. Leads are factory sealed to meet the requirements of Article 501 of the National Electrical Codes (NEC). The SAFE-T SHP9 Stirring Hot Plate must be hardwired per NEC (USA) or CEC (Canada) requirements. An external switch or circuit breaker needs to be included in the building installation in close proximity of the unit as a means to disconnect supply circuit. Overcurrent protection devices should be included in the installation. The unit can be connected to a branch circuit not exceeding 20 Amps. The stirring hot plate installation must conform with installation requirements for electrical equipment intended for use in Class I, Group C and D hazardous locations as defined by the NEC and electrical code requirements of your area. 7

Operation Heating Specifications Element Type: Cast-in Tubular Heating Element Warning Due to the nature of this product, operator safety will be endangered should maintenance or servicing be performed on it. Temperature range at the center of hotplate: 38 C - 218 C ± 3 C Temperature cut-off: 235 C ± 9 C Heat-up time to maximum temperature (218 C, unloaded top plate): 16.5 minutes at nominal voltage Caution Maximum load of the top plate is 25 lbs. (11.3 kg). Note Accuracy of the dial thermometer (part # MEX126) is ±3 C. Caution The aluminum top plate is easily stained. Do not use a wire brush to clean the unit. Using a wire brush will modify the integrity of the surface and it could affect your heat stability. Wipe the top plate with water only, using a lightly dampened non-abrasive cloth. Temperature stability at center of top plate surface at 70 C: ±1 C Temperature stability at center of top plate surface at 218 C: ±3 C Uniformity of top plate surface at 70 C (center to 1 or 2.54 cm from corners): ±2 C Uniformity of top plate surface at 218 C (center to 1 or 2.54 cm from corners): ±10 C Accuracy of the temperature indicated on the dial thermometer (see note at left) (optional) vs. the average hot plate temperature when the unit is operating at 70 C: ± 3.5 C Accuracy of the temperature indicated on the dial thermometer (see note at left) (optional part) vs. the average hot plate temperature when the unit is operating at 218 C: ±10 C Dial marks for heat control knob settings are for reference only. The dial marks indicate approximate hot plate temperature in C (±15 C). 8

OPERATION Warning To prevent ignition of hazardous atmospheres, the aluminum explosion-proof enclosure chambers must be kept closed (screws securely tightened) whenever the unit is in operation and/or connected to power supply circuit. Hot Surface Caution: Hot Surface. Avoid Contact. The top plate will remain hot without visual indication for some time after the unit is turned off. Warning Temperature cycling over a temperature range greater than 5 C with a period of approximately 6 minutes may be observed when operating the SAFE-T SHP9 at 220 C or higher. If such cycling is observed, the unit is functioning under abnormal or fault conditions and the secondary bimetallic thermostat is controlling the top plate temperature. Under these circumstances, the unit should first be turned off at both the heat and stir dial switches and the external circuit breaker and allowed to cool completely. Next, in an atmosphere absolutely free of flammable liquids, gases, and/or vapors, test the heat control function of the SAFE-T SHP9 at several temperature settings within the range of 38 C to 220 C. If the top plate temperature of the unit again cycles with a period of approximately 6 minutes over a temperature range greater than 5 C when ramping to or operating at 220 C, return the unit to the factory. Setting the Temperature Dial (Control) Switch Turn clockwise to the desired temperature. Dial marks indicate approximate surface temperature in C. When the temperature for a given dial setting has been reached, the control will regulate the hot plate. To turn OFF hot plate, turn dial switch fully counterclockwise to the OFF position. Use of Dial Thermometer The optional dial thermometer (part # MEX126) can be used to set and monitor the temperature of the aluminum top plate. Heating Metal Vessels Metal vessels may be heated safely on the SAFE-T SHP9 without the danger of the vessel reflecting enough heat back to the top to cause the aluminum to soften. The electronic control in the SAFE-T SHP9 will regulate the aluminum top plate temperature. Warning To prevent ignition of hazardous atmospheres, do not use electrical equipment such as a thermocouple and pyrometer to monitor the hot plate temperature unless it is UL listed for the same hazardous atmospheres and temperature rating as the SAFE-T SHP9. The thermocouple and pyrometer could serve as a source of ignition. 9

Unit* SP87325 (120V) Temperature Setpoint Max.Dial Setting 230 Flask Size Amount of Solution Time to Vigorous Boil 1 Liter 600 ml water 60 min.

OPERATION Unit* Flask Size Stirring Speed Guide (All stirring speed measurements made at 21.5 C) Stir Bar Size Amount of Solution Viscosity Maximum Speed** SP87325 1 liter 2 in. 600 ml water 1,200 rpm SP87325 1 liter 2 in. 600 ml corn oil 1,200 rpm SP87325 1 liter 2 in 600 ml SP87325 500 ml 2 in 350 ml 30 weight motor oil 1,265 centipoise viscosity std. 950 rpm 400 rpm SP87325 1 liter 2 in 350 ml corn syrup (light) 70 rpm *The SP87324 unit performs similarly. **Maximum speed obtained without the stir bar losing coupling with the magnet in the SAFE-T SHP9. 11

Maintenance and Servicing Caution To reduce the risk of the ignition of hazardous atmospheres, no repairs are to be made to this product. Due to the nature of this product, operator safety will be endangered should maintenance or servicing be performed on it by the operator. The unit does not contain serviceable parts. 12

For the name of the authorized Thermo Scientific product dealer nearest you or any additional information, contact us: North America: USA/Canada +1 866 984 3766 (866-9-THERMO) www.thermo.com Europe: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, France +33 2 2803 2180, Germany national toll free 08001-536 376,Germany international +49 6184 90 6940, Italy +39 02 02 95059 434-254-375, Netherlands +31 76 571 4440, Nordic/Baltic countries +358 9 329 100,Russia/CIS +7 (812) 703 42 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203 Asia: China +86 21 6865 4588 or +86 10 8419 3588, India toll free 1800 22 8374, India +91 22 6716 2200,Japan +81 45 453 9220,Other Asian countries +852 2885 4613 Countries not listed: +49 6184 90 6940 or +33 2 2803 2180