Smoke Fire Damper Interface (230V)

Similar documents
Smoke Damper Interface (230V)

Fire Damper Interface (230V)

Fire Damper Interface (24V)

Lonworks Damper Interface Catalogue

Installation Datasheet

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

V3 Intelligent Damper Control and Monitoring System

DESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B

Installation Guide. Bacharach HGM300 to LonWorks FT-10 Communications Adapter

DESCRIPTION MODEL 1205/1205HA NOTE

October 2013 Bespoke Intelligent Damper Control and Monitoring System

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

EFBW series - BiWire Ultra control panel

Network Variables for Model CM4 LONWORKS Protocol Version 1.2

Instructions for the fan motor control system with integrated wiring terminals SILVER C

KM300 Carbon Monoxide Detection System Installation Manual

Retroreflective sensor with polarization filter

Duct Temperature Sensors

Input module, input/output modules

Original operating instructions Safety switch with guard locking AC901S AC902S

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Multi-Gas-Controller MGC2

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Excellence in Level Measurement

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Instructions for the fan motor control system, SILVER C

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Predator Controller Hardware Family

FEC403EN Installation Manual

SensaGuard TM Integrated Latch Installation Instructions

MANUAL Overflow sensor NVF-104/34-PF

Power Supply Display Module PSDM. Installation and Operation Manual

Wireless room thermostat with LCD

Labkotec Ice Detector

Installation, Operating and Maintenance Manual

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

ISIS SAFETY SYSTEM Installation guide

Operation and use. Functions and characteristics

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

5, SE GÅNGHESTER,

Input module, input/output module

Multi-Zone Wireless Control Training Systems ( )

Ionisation single-tube smoke detector for duct mounting

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

CU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Turbimax CUE21 / CUE22

EOTec 2C32 Installation Guide

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

MTRA-FSP Level Control Relay. Installation & Operation Manual

Certificate of Compliance

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

HYTEK ATEX APPROVED TANK ALARM

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Conductive Leakage detectors of the Leckstar range

DM1131 / DM1133 / DM1134 Manual call points

Instruction Manual December 2001 ENACOCU02

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

CommStat 4 Controller

Door Release Power Supply

LAE10 LFE10. Use. Series 02

Product Specifications Warning Light Control Cabinet

The EN54 Part 2 and 4 Fire System

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Climatix LON communication with POL SNVTs for Twin Wheel application v1.x

Instruction Manual August sitrans CU 02

System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are:

CU-02 with Senaco Plus

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Operating Manual MS220KA and MSR220KA

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Dräger Polytron 7000 Fixed gas detector

OPTISENS TUR 2000 Technical Datasheet

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

1.7. Insulation fault evaluators EDS460/490 EDS461/491

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

QPM21 Series Duct CO 2 and Air Quality Sensors

Magnetically Coded Non-contact Switch (MC2)

Certificate of Compliance

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

4) Intrinsic Safety Certification

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Transcription:

Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly put at risk the lives of the occupants and the fabric of the building. Smoke Fire Damper Interface SFDI 230V AC 50Hz 25VA Installation Instructions and Datasheet Smoke Fire Damper Interface (230V) The Safegard Smoke Fire Damper Interface provides a complete LonWorks communication device to control any failsafe spring-return smoke fire damper actuator that incorporates two auxiliary switches. Two additional auxiliary inputs are provided for interfacing to local duct smoke detectors etc. Safegard developed the LonMark Functional Profile (11001) for smoke fire dampers and this has been adopted worldwide. ELECTROSTATIC SENSITIVE DEVICE PAGE 1

Dimensions and Mounting The compact and robust design of the SFDI enclosure allows the unit to be mounted to a duct, block wall or stud wall. Mounting Diagram 200 75 aprox 25 Ensure the SFDI is located close enough to the actuator it is controlling/monitoring. Normally, actuator leads are 1m in length. Also, ensure the SFDI is accessible for future maintenance purposes. Please note: Unused cable entries should be sealed with blind washers. Do not drill the enclosure as this will affect its IP rating. 160 60 15 aprox 25 120 Four mounting holes Ø 6mm for mounting with suitable screws depending on whether mounting to a duct, block wall or stud wall. Dimensions in mm. 220 10 PAGE 2

Preparation Wiring Diagram (SFDI in enclosure without lid fitted) Only trained and qualified personnel should be allowed to install, replace or service this equipment. Installation should be in accordance with the relevant local safety standards. The connectors can accommodate cable diameters up to 2.5mm 2. It is recommended that all wires be crimped to ease installation and replacement of the product. BELIMO BF230-T Actuator Example 230V Actuator Drive 2 1 S6 Thermal Trip Actuator Position Sense S4 S2 S1 To Heat Detector To Smoke Detector OPTIONAL HD SD The mains wiring should comply with IEC 60227 or IEC 60245. Aux Inputs A switch or circuit breaker should be included as part of the installation. The switch or circuit breaker should meet the relevant requirements of IEC 60947-1 and IEC 60947-3. The switch or circuit breaker should be in close proximity to the equipment and be within easy reach of the operator. The switch or circuit breaker should be marked as the disconnecting device for the equipment and should disconnect both poles of the supply F3 J7 L N POWER IN ACTUATOR DRIVE SWITCH INPUTS AUX1 AUX2 Green LED Red LED Yellow LED Blue LED L N S6 S4 S2 S1 - + - + J4 J5 J6 Service LED Power LED J2 NETWORK Service Switch J3 NETWORK Installation 1AT Network Network 1. Disconnect the local supply before commencing any work on the SFDI. L N 2. Wire the SFDI in accordance with the wiring diagram shown across. If actuator is to be located more than 5m from the SFDI then contact Safegard Systems for technical assistance. 3. Please be aware that the switch and auxiliary inputs are not optically isolated. It is recommended that the optional detectors (smoke or heat) use failsafe open contacts to guarantee their detection in the event of a fault condition. It is also recommended that the network cables are not run alongside any high voltage or high frequency sources. Also, network cables must not be mixed on an individual network as they have very different electrical characteristics and could render the system unreliable. 4. Once wiring is complete, apply power to the SFDI. The green power LED should illuminate to indicate the presence of power. 5. The SFDI is now ready to be configured using a standard LonWorks tool such as LonMaker or the Safegard system. LED Behaviour Function Green Red Yellow Blue Open On Off Closed Off On Travelling Flashing Flashing Fault Flashing Ping one-shot Offline On On On On Wink function: Service LED flashes for 5s Maintenance 250mAT 250 VAC (see F3 on wiring diagram) Suggested replacement: Bussman S504 series. PAGE 3

LonMark Objects Node object Mandatory network variables nv1 nvirequest SNVT_obj_request nv2 nvostatus SNVT_obj_status Optional network variables nv4 nvoalarm SNVT_alarm FSDA object Mandatory network variables nv1 nviactudrive nv2 nvoactuposn Optional network variables nv3 nvoactudrivefb Configuration properties Mandatory nc45 Drive Time nc48 Receive Heartbeat nc44 Safety Position nc30 Turn Off Time nc141 Zone Number Optional nc41 Actuator Label nc146 Installation Date nc17 Location Label nc147 Maintenance Date nc148 Manufacture Date nc61 OEM Label nc49 Send Heartbeat PAGE 4

Specification LonWorks Neuron chip Transceiver type FT 3120-E4 V16, 5 MHz tp/ft-10 Environmental Operating temperature -5 C to 70 C Storage temperature -20 C to 70 C Service functions Supply Input voltage Maximum power consumption 5 W Service pin, service LED and neuron ID self-adhesive tag (230 ± 23) V AC, 50 Hz Humidity 25 % RH to 90 % RH at 70 C Maximum altitude Conformance 2000 m emc en 50081-1: 1992 en 61000-6-2: 1999 Output Contact type Maximum switched load Inputs Contact type Sense current DPCO mechanical relay contacts 25 VA non-isolated dry contacts 19 ma at 12 V DC LVD en 61010-1: 2001 LonMark 11001 Enclosure Material IP rating IP 54 Flammability ul 94V-0 Pollution category 2 Dimensions (excl glands) abs base with polycarbonate lid 200 mm x 120 mm x 75 mm (L x W x D) Dimensions (incl glands) 200 mm x 170 mm x 75 mm (L x W x D) Note: Optional HSFDI available at 300 C for 1 hour applications. Contact Safegard Systems for details. Symbols Complies with European standards IEC 60417-5172 Equipment protected throughout by DOUBLE INSULATION Complies to LonMark Interoperability Guidelines (ISO 7000-0434) WARNING: The responsible body shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 1996-2007 Safegard Systems Limited. The information herein is subject to change without notice. We do not assume any liability arising out of the use of this product. Purchase of goods and services is subject to Safegard Systems standard terms and conditions. Product warranty 12 months from date of delivery. LonWorks, LonMark, LonMaker and the 3120 are trademarks of Echelon Corporation registered in the United States and other countries. All other trademarks are acknowledged. Systems House, Unit 34, Southern Cross Business Park, Bray, Co. Wicklow T: +353 1 2761600 F: +353 1 2761611 E: info@safegard.ie www.safegard.ie