RangerNET Network Ready Constant Monitor Model CM2815

Similar documents
Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

A2CM2 Dual Wire Continuous Resistance Monitor

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Bench Top Ionizer Installation, Operation and Maintenance

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

Installation Manual COPYRIGHT NOTICE

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

FLT93 Installation, Operation and Troubleshooting Guide

Long Range Radio Alarm Transmitter

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Alarm Tone Generator Model AG17

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

Long Range Radio Alarm Transmitter

Remote Sensor Module: EB-RSM-01

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

STEP-HEAR Activator (SH-220)

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Mark 25 Ultrapure Water Conductivity Analyzer

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

NT DUAL CHANNEL DISPLAY. User Guide

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTALLATION INSTRUCTIONS

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

CA5000 Liquid CO 2 Freezer Backup System

Advantium 16 System Monitor

Beacon 800 Gas Monitor Operator s Manual

Critical Environment Ionizing Blower. Model 5810i. User s Manual

Chargebuster Ion Gun Installation, Operation and Maintenance

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Universal Clamp Meter

CO2 Sensor User and Installation Guide

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Chargebuster Ion Gun Installation, Operation and Maintenance

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

KT-100 Door Controller

VX SERIES Wireless Thermostat with Occupancy Sensor

Comfort Series Instant Hot Water System

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

User's Guide. Pinless Moisture Meter. Model MO257

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

OPERATION MANUAL MODEL & ACCELEROMETER

Pump-Up Controller MODEL 4062

LMA LINE MONITOR ALERT USER S MANUAL

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Freeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions

6502B RF Distribution

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Pump-Down Controller MODEL 4052

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

2-Port alarmcharge Hub - Manual

STATUS ALARM HISTORY ALARM RESET

FUME HOOD MONITOR ALNOR AIRGARD 200

Knight Trak II Instruction Manual

High Temperature InfraRed Thermometer with Laser Pointer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Protocol Station Remote Alarm

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Static Pressure Control

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

EVO192 v3.0 Fire and Burglary What s New

CZ-6A Six Zone Interface Module

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

INSTALLATION MANUAL PC56O. Version 1.OA

Veritas Appliance Hardware Service Procedure

RK Combustible Gas Transmitter Operator s Manual

C0-210 Carbon Monoxide Probe

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

MGC Dock User s Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Document No

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Computer Room Guard Model VM Manual and Installation Instructions

Transcription:

RangerNET Network Ready Constant Monitor Model CM2815 Instruction Manual

Contents 1 Description CM2815 1 Features 1 2 Installation Installation Instructions 2 Installation Diagram 3 3 Operation Wrist Strap Indications 5 Mat Indications 6 GND monitor Indications 6 Maintenance 6 4 Specifications 7 6 Service and Warranty 9 2

Ohm Metrics Resistance Monitor: CM2815 The Ohm Metrics' CM2815 Series dual conductor workstation monitor provides continuous monitoring of resistance for two wrist straps and two mat. The status are displayed using tricolor LED s on the front panel of the monitor and abnormal levels trigger an alarm to inform operators on the line. Utilizing low-voltage, resistive loop technology, and dual conductor ground products, the CM2815is an extremely sensitive and reliable ground monitoring for use in highly critical areas. The CM2815 is network ready and can easily be connected to other workstation monitors and a computer using the high speed network router, CM2800-H. The host computer can be transformed into a command center with the software CM2800-BOSS SEE, a central monitoring program that shows real time grounding results and allows for adjustment of alarm parameters of up to 4096 workstations. An entire assembly line s ESD protection can be remotely monitored and adjusted with one computer. Features: Monitors two wrist straps, and work surfaces. Network Ready Ultra-Low voltage for highly critical areas. Uses Dual Conductor Wrist Straps 3

Operation The CM2815 monitors the grounding functions of a workstation and alerts users when levels are out of the set range. The CM2815 has the capabilities to monitor the resistance of two wrist straps/operators and two Work surfaces. Alerts If any parameters exceed the preset high limits, the corresponding LED on the front panel of the monitor will change color from green (OK) to red (high warning) to indicate the abnormal situation. If the resistance is below preset low limit, the LED color will be yellow (low warning). An audible alarm will sound, in addition to the corresponding LED indicator when the resistance is in an abnormal state. For instant differentiation, a single beep will sound if the abnormal situation occurs on Station 1 whereas a double beep sound for Station 2. (LED indicators illustration of CM2800 front panel.) OP 1 and OP 2 - Grounding resistance of operators V1 and V2 - Induced voltage on operator - disabled on CM28015 MAT1 and MAT2 - Grounding resistance of work surfaces G1 and G2 - Grounding resistance of tools- disabled on CM28015 *The CM2815 only utilizes OP1, OP2, MAT1, MAT2 1. Operator Grounding The operator is grounded when the dual conductor wrist strap is plugged in to the jack labeled OP of the grey remote. The corresponding LED label OP and V will be GREEN if levels are normal. If the any of these parameters exceed preset high limits, the corresponding LED will turn RED and alarm will sound. If the resistance of the wrist strap is below preset low limit, the LED will turn YELLOW and alarm. If the wrist 4

strap is not plugged into the remote terminal jack, the LED s of both OP and V will be off to indicate the stand-by mode. Factory set resistance limit is 1.8 megohm. Default Voltage limit is 2V. Since the CM2815 is designed with a Ultra-Low Voltage circuit, the measurement voltage of the grounding resistance of the operator body can be as low as 0.2V. Therefore, when the low resistance of the wrist strap is measured, it may be affected by the small Battery Effect existed between the contact of the human body skin and the wrist-strap metal stud. To avoid this, the the low resistance measurement is disabled by default. If this measurement is turned on and the value is affected, you can reverse the direction of the wrist strap stud to resolve the influence. If the cable connecting to a wrist strap remote is unplugged or severed at either end, the monitor s audible alarm will sound, and the corresponding OP LED will turn red. Note: Each remote has two jacks labeled OP and AUX. The OP jack is monitored and AUX jack is not, but provides a grounding path for one more wrist strap. The status of AUX will not affect OP. 2. ESD Mat The CM2815 can monitor the ground resistance of two dissipative surfaces. When the resistance is within acceptable limits, the LED labeled MAT will be GREEN. If it exceeds preset high limits, the LED will change to RED and an alarm will sound. Factory limits are set at 100 meg ohm. Installation Before you install your device, check for the items below: 1 - CM2815 workstation monitor 2 - Remote Jacks 1 - Power Supply 2 - Telephone Cables 3 - Grounding Cables: FM1515, FM1515CM, FM1515NR 5

Please carefully read the following instructions before proceeding with product installation. 1. Install monitor in a location where alarm indicators will be visible and alarm will be audible to operator. Typical locations are under a workstation table or low shelf. 2. Mount monitor securely in place with Velcro. 3. Install remote wrist strap terminals in a convenient location for operators. Frequently remotes are mounted on the underside of the workbench nearest operators. 5. Plug the telephone cable from the left remote to the OP1 on the back of monitor. 6. Plug the telephone cable from the right remote to the OP2 on the back of monitor. 7. Connect the bare end of the FM1515CM wire to the terminal on the back of the monitor labeled GND and connect to GROUND. See wiring diagram. Mat Set Up: If no grounded ESD mats are to be monitored, connect a wire from both M1 and M2 terminals to the GND terminal on the back of the monitor and skip steps 8 and 9. 8. Connect the FM1515NR cord from the first grounded Mat to the terminal on the back of the monitor labeled M1. 9. Repeat step 8 with an additional FM1515NR (not-included) if an additional mat is to be grounded. If not, connect a wire from M2 to GND to disable alarm function. Note: The work surface mats have to be connected to the CM2815 with zero Ohm wire for proper mat monitoring operation. Using a wire with a 1M resistor may cause alarm. The FM1515NR is the provided zero Ohm cord and more can be purchased from Transforming Technologies. 10. Plug power supply into the PWR connector on the back of the monitor and into the power line. 6

Wiring Diagram Calibration and Periodic Testing Except the operator resistances, CM2815 never needs calibration. You can verify proper operation of the monitor by periodically testing the monitor with a resistance limit comparator box CM2800PV. Every CM2815 unit is calibrated at factory to meet the following criteria: Operator Resistance: ±10% Operator voltage: ±10%, or within 3 counts at 2V or less Mat resistance: ±10% Tool resistance: ±10%, or within 3 counts at 5Ω or less If you need to calibrate the operator resistance of your CM2815 unit, please contact Transforming Technologies Accessories The CM2815 comes with a line of optional accessories: 1. CM2800-D: Digital Display & External Control Module 2. CM2800-H: Network Router 3. CM2800-IMS: Real-time Central Monitoring Software 7

CM2815 Series Monitor Specifications Wrist Strap Low Resistance Alarm Limit: 1.8 megohm. Wrist Strap High Resistance Alarm Limit: 35 meg ohm. Mat (soft ground) Resistance Alarm Limit: 100 meg ohm. Typical Operator Voltage at 10M: Imposed Voltage on Body: max 0.1V (100mV) at standard version; can be preset at factory to max 0.025V (25mV) or max 0.8V (800mV) per customer request Max Mat Voltage (open circuit): 0.2V (200mV) Max Mat Voltage (alarm at 100M): 0.15V (150mV) Max Tool Voltage (open circuit): 0.01V (10mV) Max Tool Voltage (alarm at 10 Ohm): 0.4mV Communication: Built-in RJ-485 IN and OUT communication ports to support dropline internetworking. DC Power Supply: 7-15 VDC, 100mA. AC Input: 100-240 VAC, 1A. Temperature limits: 50 F (10 C) to 122 F (50 C) Adjustments: No serviceable components; see periodic verification tools Service and Warranty Transforming Technologies, LLC provides a limited warranty for the CM2815 series. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident. In no event shall Transforming Technologies be liable for collateral or consequential damages. NOTE: Wrist strap remotes terminal boxes are subject to mechanical wearing and considered to be consumable items. They have separate warranty of 6 months. 3719 King Rd Toledo, OH 43617 P: 419-841-9552 F: 419-841-3241 info@transforming-technologies.com 8