Mechanical seals external, single or double, to DIN EN 12756

Similar documents
Mechanical Seal RG-4 stationary, double, liquid sealed

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

Dosing system. Commissioning and maintenance manual eco-pen300

BioMaster 250/350/600 BioMaster Thermo 250/350/600

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Temperature Sensor TRG Original Installation Instructions English

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

CHIPPER PC1 INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE. Series 35

SAM TURBO INDUSTRY LIMITED

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

HD Kompakt Service Manual

Instructions for Installation, Operation, Care and Maintenance

This label warns for risk of electrical shock when failing to observe.

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

AC6/6H & AC8/8H Horizontal Metric Models

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

CENTAFLEX Series A Assembly and operating instructions CF-AR M EN Rev. 2

Pneumatic agitator A MAN R

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Operating and installation instructions

AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION

Design and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

TECHNICAL DATA. Wet 26a. February 22, 2009

PENGUIN SERIES HSC PUMPS INTRODUCTION

Level Electrode NRG NRG Original Installation Instructions English

Chemical Pumps Vertical Chemical Pump Type TNP

Vertical Ring-section Pump WKTB. Type Series Booklet

569, 570, 571, 572 Series

569, 570, 571, 572 Series

FSW300 Series Flow Switch

SuperKlean Washdown Products

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

Chemical Motor Pump Unit BN

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

NRG NRG NRG NRG

USER S MANUAL ATH WH220

Conductivity Electrode LRG Original Installation Instructions English

568X, 587X, 588X Series

INSTRUCTION AND REPAIR MANUAL

Operation, Maintenance and Installation Manual

Platen Heater Pad Replacement

RAYPAK REPLACEMENT INSTRUCTIONS

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

CORREX MP Anode with external voltage source. Installation & Operation Manual

INSTRUCTION MANUAL with Replacement Parts

Service Documentation Market Release 7/84. Braun Kitchen machine KM 32 B 4209 with lamp

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Operating instructions

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

English CNA-CNB. Centrifugal fans Installation and maintenance

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

#PSBTWE1000 INSTALLATION GUIDE

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Service package PDAD- -SP (en) Assembly instructions d [ ]

17 U.S. gallon portable low profile drain with electric pump

Block Macerators Series ABM-2-S

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Oil burners fuel unit with solenoid valve

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Operating Instructions

Installing a Fast Oven Upgrade Kit

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

TTV 4500 / TTV 4500 HP / TTV 7000

HEATING AND AIR CONDITIONING

Hakki Pilke Raven spare parts manual

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Lo-Carbon T-series Window & Roof Models

Friwa Compact. Operating instructions EN

Oil burners fuel unit with solenoid valve

Model: 1100 Float-Controlled Condensate Trap, PN 25

OWNERS GUIDE TO INSTALLATION AND OPERATION

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Laboport Chemically-resistant Laboratory Pumps and Systems

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

1 SAFETY INSTALLATION OPERATION FAULT DIAGNOSTICS COMPONENTS FUNCTIONS TECHNICAL SPECIFICATIONS...

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

INSTALLATION & MAINTENANCE

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Installation Instructions Part No , Part No Part No

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Transcription:

INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly observed before transport, installation, operation and maintenance Subject to change without notice. Reproduction is generally permitted with indication of the source. Richter Chemie-Technik GmbH. Edition 02/2012

Series SCK, Mechanical Seals, external, single and Page 2 List of Contents List of Contents... 2 Relevant documents... 2 1 Technical data... 2 2 Safety, transport, storage and disposal... 3 2.1 Intended use... 3 3 Product description... 3 4 Commissioning/Shutdown... 3 4.1 Initial commissioning... 3 4.2 Mechanical seals... 3 4.2.1 Use in an explosive area... 3 4.2.2 External single mechanical seal... 3 4.2.3 Double mechanical seal to DIN EN 12756... 4 4.3 Improper operations and their consequences (exam ples)... 4 5 Maintenance... 4 5.1 External, single mechanical seal... 4 5.1.1 Dismantling... 5 5.1.2 Notes on assembly... 5 5.2 Double mechanical seal to DIN EN 12756 5 5.2.1 Dismantling of impeller and back plate... 5 5.2.2 Dismantling the shaft sleeve... 6 5.3 Notes on assembly... 6 6 Malfunctions... 6 7 Sectional drawing... 7 7.1 Sectional drawing external, single mechanical seal... 7 7.2 Sectional drawing double mechanical seal to DIN EN 12756... 8 Relevant documents Installation and operating manual SCK long life grease or oil bath lubrication Bearing pedestal group 0 9220-053-en Operating manual mechanical seal of the manufacturer 1 Technical data Manufacturer : Richter Chemie-Technik GmbH Otto-Schott-Str. 2 D-47906 Kempen Telephone:+49 (0) 2152 146-0 Fax: +49 (0) 2152 146-190 E-Mail: richter-info@idexcorp.com Internet: http://www.richter-ct.com Authorised person acc. to machinery directive 2006/42/EC: Gregor Kleining Designation : Series SCK mechanical seal: External, single Materials : Seal housing: Stainless steel Wetted parts: Mechanical seal : SSiC, Al2O3/PTFE glass, etc. see also data sheet Temperature range : see installation and operating manual SCK, Section 1.

Series SCK, Mechanical Seals, external, single and Page 3 2 Safety, transport, storage and disposal The relevant sections in the adjacent installation and operating manuals apply to safety, transport and storage. This installation and operating manual is only valid in conjunction with the installation and operating manuals of SCK long life grease and oil bath lubrication Bearing pedestal group 0 9220-053-en 2.1 Intended use Mechanical seals for plastic-lined pumps of the series SCK are suitable for the use of aggressive, and pure media. Observe the instructions contained in the operating manual or contractual documentation; if necessary, consult the manufacturer. All important features are documented in the data sheet included in the scope of delivery. 3 Product description For a product description of the pump, see the installation and operating manual for the SCK series. Section 7.1 The sectional drawing shows a external, single mechanical seal. Section 7.2 The sectional drawing shows a double mechanical seal to DIN EN 12756. 4 Commissioning/Shutdown 4.1 Initial commissioning See installation and operating manual for the series SCK. 4.2 Mechanical seals The design and material combination are specified in the data sheet. The proper condition of the components and the protective facilities must be ensured to prevent any risk from escaping medium. The regulations and recommendations of the mechanical seal manufacturer must always be observed. 4.2.1 Use in an explosive area Use in an explosive area means that only mechanical seals may be employed which permit observation of temperature. The operating manual of the respective mechanical seal manufacturer is an integral part of this general operating manual. This permits, amongst other things, the calculation of the expected surface temperature at the mechanical seal. The suitability for the permissible temperature class as per ATEX is hereby given. Caution! The permissible temperature class of the complete unit (pump, mechanical seal, coupling, motor) is determined by the lowest temperature class of the individual components. Example: Pump T4, mechanical seal T3, coupling T4, motor T4 The unit may only be used in atmospheres which may ignite above the temperature class T3, i.e. >200 C. 4.2.2 External single mechanical seal Pumps fitted with a single mechanical seal must not be started up before they are filled with medium. Otherwise the single mechanical seal is not lubricated and cooled and could be damaged. Mechanical seal guard mounted? See sectional drawing Section 7.

Series SCK, Mechanical Seals, external, single and Page 4 4.2.3 Double mechanical seal to DIN EN 12756 A pump fitted with a double mechanical seal must not be filled with a product before the pressurisation system provided has been started up. Otherwise damage could occur, e.g. opening of the wetted sealing gap, before start-up. To guarantee safe operation, the pressure of the sealing liquid must be 1-2 bar above the pressure of the process medium at the mechanical seal at Q=0 m 3 /h. It must be ensured that the barrier pressure does not exceed the admissible pressure of the mechanical seal used. The required sealing pressure can be determined as follows: 2/3 of the delivery pressure at Q = 0 m 3 /h + supply pressure + 1 - -2 bar safety margin The supply pressure is measured in bar at the pump suction nozzle. If no measuring point is available, the supply pressure can be calculated using the following formula. Using the same formula, the delivery pressure at Q=0 m 3 /h can be determined with the pump characteristic curve. ρ H(mFS) x (kg/dm p (bar) = 10,2 3 ) p=supply pressure or delivery pressure H = supply height or delivery head ρ = density If the seal is provided with process water, a flow rate of approx. 80 l per hour should be set at the required barrier pressure which can be reduced in subsequent operation so that the sealing liquid flows out slightly heated. Are the available connections correctly made? SE - sealing liquid inlet SA - sealing liquid outlet See also sectional drawing in Section 7.2. 4.3 Improper operations and their consequences (examples) Improper operation, even for brief periods, may result in serious damage to the unit. In connection with explosion protection, potential sources of ignition (overheating, electrostatic and induced charges, mechanical and electric sparks) can result from these inadmissible modes of operation; their occurrence can only be prevented by adhering to the intended use. For examples, see installation and operating manual SCK, Section 6.6. 5 Maintenance The regulations of the mechanical seal manufacturer must always be observed. See also the installation and operating manual for the SCK series. 5.1 External, single mechanical seal In normal operations this seal should not drip. The leak should only be so minimal that it evaporates immediately. It is advisable to check the attachment screws of the mating ring adapter 487 and of the rotating unit 470/2 for a tight fit from time to time. The external mechanical seals are to be replaced before the wear on the rotary ring become so great that the pressing forces are no longer sufficient as a result major leaks occur. Often marks on the mechanical seal indicate the admissible wear. The wear on the rotary ring can be readily seen by the increased size of the set dimension in many makes. See Fig. 1. Setting dimensions to regulations Fig. 1 Dismantling can be checked using the sectional drawings in Section 7.3 and Section 9 of the belonging to installation and operating manual SCK as well as the components available.

Series SCK, Mechanical Seals, external, single and Page 5 5.1.1 Dismantling Undo attachment screws of the rotating unit 470/2. Loosen impeller 230 with a strap wrench or assembly wrench. Right-hand thread! For assembly aid for impeller, see Section 10.1 in the installation and operating manual SCK. See also installation and operating manual SCK, Section 7.7.1 Unscrew the impeller 230 completely. Loosen bracket screw 901/10, 554/4 and 920/4. Pull the bracket 344 with back plate insert 168, mating ring adapter 487 and mating ring 475/1 off the shaft sleeve 524. After undoing the nuts 920/3 with the washers 554/3, the mating ring adapter 487 is removed first. Then remove mating ring 475/1. Remove circlip 932/4 from the 2-piece ring 501 and take back plate insert 168 out of the bracket 344. Now pull the shaft sleeve 524 with the rotating unit 470/1 which is still installed off the shaft. When changing the rotating unit 470/2, observe the operating manual of the mechanical seal manufacturer. Pull spring bushing 546 off the shaft 210. The cup springs 950/1 can be changed. See sectional drawing in Section 9.2 in the relevant installation and assembly manual SCK. If the plastic bearing points of a ceramic shaft sleeve are damaged, these can be renewed by the pump manufacturer. 5.1.2 Notes on assembly Only use original spare parts. Do not use any defective parts. The recommendations of the mechanical seal manufacturer are to be observed. External single mechanical seals can best be brought to the required pre-tension with a tensioning device available from Richter. See Section 10.4 assembly aids in the installation and operating manual PCK. Prepare rotating unit (observe setting dimension) and tighten on the shaft sleeve. 5.2 Double mechanical seal to DIN EN 12756 It is important to ensure the prompt replenishment of any sealing liquid which has escaped, the monitoring of the sealing liquid pressure. The minimum sealing liquid pressure must never be undershot as long as the pump housing is under pressure. Refer also to the description of the pressurisation system used and Section 4.2.2. If the sealing liquid pressure is too high, this indicates a defect in the mechanical seal even though the mechanical seal on the atmosphere side is completely tight. The pump must then be shut down so that no serious damage occurs. Considerable damage may arise: if the sealing liquid pressure falls below the minimum pressure and the aggressive medium penetrates the pressurisation system. In the event of the risk of pressure surges in the plant, precautions must be taken, e.g. increasing the sealing liquid pressure up to the pressure limit of the mechanical seal used. Dismantling can be checked using the sectional drawings in Section 7.3 and Section 9 of the installation and operating manual SCK as well as the components available. 5.2.1 Dismantling of impeller and back plate First of all relieve the mechanical seal by undoing the hex. nut 920/5. Undo screw-in pipe connectors 917/1 and 917/2 from the seal housing 483. Loosen impeller 230 with a strap wrench or assembly wrench. Right-hand thread! For assembly aid for impeller, see Section 10.1 in the installation and operating manual SCK..See also installation and operating manual PCK, Section 7.7.1 Unscrew the impeller 230 completely. Loosen bracket screw 901/10, 554/4 and 920/4. Remove bracket 344. It may happen that the mating ring carrier 476 is removed at the same time as the mating ring 475/1. If the mating ring 475/1 is replaced, remove die anti-torsion insert, stud 560/1. Remove circlip 932/4 from the 2-piece ring 501 and take the back plate insert 168 from the bracket 344.

Series SCK, Mechanical Seals, external, single and Page 6 5.2.2 Dismantling the shaft sleeve Remove seal housing 483. Pull the shaft sleeve 524 with the rotating units 470/1 and 470/2 off the shaft. When changing the rotating unit, observe the operating manual of the mechanical seal manufacturer. Remove mating ring carrier 476 with mating ring 475/2. If the mating ring 475/2 is replaced, press it out of the mating ring carrier 476. Pull spring bushing 546 off the shaft 210. The cup springs 950/1 can be replaced. See sectional drawing in Section 9.2 in the relevant installation and assembly manual SCK. 5.3 Notes on assembly Only use original spare parts. Do not use any defective parts. The recommendations of the mechanical seal manufacturer are to be observed. If the rotating units are moved by a key, the two seal halves are to be pushed from both sides onto the shaft sleeve. Otherwise the secondary seal would be damaged on the sharp edges of the key groove. PTFE rings are often easier to install if they have been previously heated in hot water. The mating ring carrier 476 is designed with an anti-torsion insert for the wetted mating ring. It must be ensured that the mating ring is properly installed in this device. With some mechanical seal types the rotating units can be better pushed over the shaft sleeve when dismantled. Mount rotating unit 470/2 with pumping thread on the impeller side. The rotating units 470/1 and 470/2 must be flush with the key 940/2. 6 Malfunctions Faults may result from inadmissible modes of operation. Such improper operation even brief ones may cause serious damage to the unit. In connection with explosion protection, potential sources of ignition (overheating, electrostatic and induced charges, mechanical and electric sparks) can result from these inadmissible modes of operation; their occurrence can only be prevented by adhering to the intended use. See also Section 2.1. Should there be any uncertainty about the remedy to be applied, please inquire at the in-house pump office or at the pump manufacturer's. See also Section 8 in the installation and operating manual of the SCK series.

Series SCK, Mechanical Seals, external, single and Page 7 7 Sectional drawing 7.1 Sectional drawing external, single mechanical seal 168 back plate insert 210 shaft 230 impeller 344 bracket 400/3 flat gasket 470/2 rotating unit 475/1 mating ring 487 mating ring adapter 501 ring, 2-piece 524 shaft sleeve 546 spring bushing 554/x washer 685 seal guard 901/x hex. screw 902/3 stud screw 920/x Hex. nut 932/4 circlip 950/1 cup spring Option 518* support ring 914/1* hex. socket screw

Series SCK, Mechanical Seals, external, single and Page 8 7.2 Sectional drawing double mechanical seal to DIN EN 12756 168 back plate insert 210 shaft 230 impeller 344 bracket 400/x flat gasket 417/x seat ring 470/x rotating unit 471 cover seal 475/x mating ring 476 mating ring carrier 483 seal housing 501 ring, 2-piece 524 shaft sleeve 546 spring bushing 531/1 spring-type slotted pin 554/x washer 560/2 stud 901/10 hex. screw 902/2 stud screw 917/x screw-in pipe connector 920/x hex. nut 932/x circlip 940/2 key 950/1 cup spring SE = sealing liquid inlet SA = sealing liquid outlet / draining