Product Data Split System Heat Pump 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036D1000A 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. March 2016 12-1175-9A-EN
Product Specifications Model No. (a) 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036D1000A POWER CONNS. V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 12 14 17 22 BR. CIR. PROT. RTG. MAX. (AMPS) 20 25 25 35 COMPRESSOR DURATION - SCROLL DURATION - SCROLL DURATION - SCROLL DURATION - SCROLL RL AMPS LR AMPS 9 56 10.9 62.9 12.8 67.8 16.7 79 Outdoor Fan FL AMPS 0.54 0.64 0.77 0.95 Fan HP 1/12 1/8 1/8 1/5 Fan Dia (inches) 23 23 27.5 27.5 Coil SPINE FIN SPINE FIN SPINE FIN SPINE FIN Refrigerant R-410A 6 LBS., 1 OZ 6 LBS., 2 OZ 6 LBS., 13 OZ 6 LBS., 2 OZ LINE SIZE IN. O.D. GAS (c) (d) 3/4 3/4 3/4 3/4 LINE SIZE IN. O.D. LIQ. 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10 F 10 F 8 F 8 F Dimensions H x W X D Crated (IN.) 30.1 x 30 x 26.7 34 x 33 x 30.1 34.4 x 35.1 x 38.7 38.4 x 38.7 x 35.1 Weight Shipping (lbs.) 161 191 248 229 Weight Net (lbs.) 141 163 216 198 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA AY28X084 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 BAYLOAM103 Refrigerant Lineset (e) TAYREFLN7* TAYREFLN7* TAYREFLN7* TAYREFLN7* Sound Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Service Valve Panel Cover AAYSVPANL0022AA AAYSVPANL0032AA AAYSVPANL0032AA AAYSVPANL3343AA (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications (xx denotes latest revision). (d) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer s Guide for full charging instructions. (e) * = 15, 20, 25, 30, 40 and 50 foot lineset available. 2 12-1175-9A-EN
Product Specifications Model No. (a) 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A POWER CONNS. V/PH/HZ (b) 280/230/1/60 280/230/1/60 280/230/1/60 MIN. BRCH. CIR. AMPACITY 25 26 32 BR. CIR. PROT. RTG. MAX. (AMPS) 40 45 50 COMPRESSOR DURATION - SCROLL DURATION - SCROLL DURATION - SCROLL RL AMPS LR AMPS 19.2 124 19.6 130 24.4 144 Outdoor Fan FL AMPS 1.05 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27.5 27.5 27.5 Coil SPINE FIN SPINE FIN SPINE FIN Refrigerant R-410A 7 LBS., 8 OZ 8 LBS., 2 OZ 9 LBS., 14 OZ LINE SIZE IN. O.D. GAS (c) (d) 7/8 7/8 1 1/8 LINE SIZE IN. O.D. LIQ. 3/8 3/8 3/8 Charge Spec. Subcooling 10 F 10 F 10 F Dimensions H x W X D Crated (IN.) 34.4 x 38.7x 35.1 38.4 x 38.7 x 35.1 51 x 38.7 x 35.1 Weight Shipping (lbs.) 248 300 315 Weight Net (lbs.) 216 266 278 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 Refrigerant Lineset (e) TAYREFLN3* TAYREFLN3* TAYREFLN3* Sound Enclosure BAYSDEN004 BAYSDEN004 BAYSDEN004 Service Valve Panel Cover AAYSVPANL0032AA AAYSVPANL3343AA AAYSVPANL0046AA (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications (xx denotes latest revision). (d) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer s Guide for full charging instructions. (e) * = 15, 20, 25, 30, 40 and 50 foot lineset available. Sound Power Level MODEL A-Weighted Sound Power Level [db(a)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6H4018G1 73 72 66 64 66 71 64 56 47 4A6H4024G1 71 77 72 68 68 69 60 53 47 4A6H4030G1 72 77 72 69 68 65 60 57 52 4A6H4036D1 76 84 75 70 72 67 62 57 50 4A6H4042G1 72 79 70 68 67 64 59 56 51 4A6H4048G1 72 81 73 68 72 67 62 57 51 4A6H4060G1 72 81 72 68 71 68 64 59 54 Note: Rated in accordance with AHRI Standard 270 2008 *For Reference Only 12-1175-9A-EN 3
Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. Model Nomenclature AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. 2. High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. 3. Low Temperature Heating 17 F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95 F outdoor air. 4 A 6 V 0 0 3 6 A 1 0 0 0 A A 4 12-1175-9A-EN
Schematic Diagrams Figure 1. 1.5, 2.0, 2.5, 3.5 Ton Models 12-1175-9A-EN 5
Schematic Diagrams Figure 2. 3.0 Ton 6 12-1175-9A-EN
Schematic Diagrams Figure 3. 4 and 5 Ton Models 12-1175-9A-EN 7
Outline Drawing Model Base A B C D E F G H J K 4A6H4018G 2 4A6H4024G 3 4A6H4030G 4 4A6H4036D 4 4A6H4042G 4 4A6H4048G 4 4A6H4060G 4 730 (28 3/4) 730 (28 3/4) 741 (29 1/8) 841 (33 1/8) 741 (29 1/8) 841 (33 1/8) 1147 (45 1/8) 724 28 1/2) 829 (32 5/8) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 651 (25 5/8) 756 (29 3/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/8 7/8 3/8 127 (5) 127 (5) 143 (5 5/8) 156 (6) 143 (5 5/8) 143 (5 5/8) 152 (6) 57 (2 1/4) 76 (3) 83 (3 1/4) 98 (3 7/8) 83 (3 1/4) 98 (3 7/8) 98 (3 7/8) 194 (7 5/8) 197 (7 3/4) 206 (8 1/8) 219 (8 5/8) 206 (8 1/8) 219 (8 5/8) 219 (8 5/8) 38 (1 1/2) 60 (2 3/8) 70 (2 3/4) 86 (3 3/8) 70 (2 3/4) 86 (3 3/8) 86 (3 3/8) 457 (18) 508 (20) 508 (20) 508 (20) 508 (20) 508 (20) 813 (32) 8 12-1175-9A-EN
Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55 F. The addition of an evaporator defrost control permits operation to 40 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. Thermostats Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control See Low Ambient Cooling. 12-1175-9A-EN 9
Notes 10 12-1175-9A-EN
Notes 12-1175-9A-EN 11
Notes American Standard optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 2016 American Standard Heating & Air Conditioning 12-1175-9A-EN 01 Mar 2016 Supersedes (New)