DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Similar documents
Operating Instructions

Technical Reference Manual

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Module Features are-configurable, no module jumpers to set

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Carbon Monoxide Transmitter

OVEN INDUSTRIES, INC.

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Analog Room Pressure Monitor RPC Series

Troubleshooting Thermo Scientific LevelPRO Gauges

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

FLT93 Installation, Operation and Troubleshooting Guide

Public Safety DAS Annunciator Panel

KT-100 Door Controller

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Model 3300 Technical Support and Installation Manual

Pump-Up Controller MODEL 4062

SAFETY INFORMATION AND WARNINGS

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Pump-Down Controller MODEL 4052

Danfoss gas detection units

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Greentrol Automation, Inc.

Event Monitoring Device (EMD)

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

PERMACONN PM1030 Includes DI300. Installation Manual

MODEL B2 INSTALLATION MANUAL

RS Pro Infrared Temperature Sensor

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

FlameGard 5 UV/IR HART

DE20 INSTRUCTION MANUAL

S304 and S305 Dust Emission Monitors. User Manual. Distributor

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Beacon 800 Gas Monitor Operator s Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Installation Guide for models:

RELEASE DEVICE CONTROLS

ELECTRONIC HUMIDISTAT: H270

WM3000 WIRELESS MODULES

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

FlameGard 5 MSIR HART

Model 17A00 Expansion Enclosure

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Halton SAFE / 7.14 user guide and installation instructions

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Ammonia Leak Detector Manual

Temperature Controllers

Mark 25 Ultrapure Water Conductivity Analyzer

Refrigerant Leak Detector Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

EasyTronic III MANUAL SERVICE

How to use the BTRM in Remote Enclosures

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

UNI-TRAN PREMIUM PLUS TOXIC GAS DETECTOR USER MANUAL UT-P+-STXXXX

INTRODUCTION / TABLE OF CONTENTS

Duct and Rough Service Carbon Monoxide Sensor

TECHNICAL DATA OBSOLETE

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Model 9010 and 9020 Monitoring Systems

Installation Guide for models:

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

eed quality electronic design USER s MANUAL

RPM1600 Series Room Pressure Monitors

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

ACCURATE ELECTRONICS INC

Series. Access Power Controllers. Installation Guide

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Fisher LCP100 Local Control Panel

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

E340 BOILER CONTROL INSTALLATION MANUAL

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Process & TeMPerATUre UniversAl input DigiTAl MeTers

RCS Residential Control Systems Inc.

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Transcription:

DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1 Electronics revision 090306 1.2 Added perforated view for ground - Wiring 090811 This document contains proprietary information of Ohmart/VEGA Corporation. It shall not be reproduced in whole, or in part, in any form, without the expressed written permission of the Ohmart/VEGA Corporation. The material in this document is provided for informational purposes only and is subject to change without notice. ISO 9001 approval by Lloyd's Register Quality Assurance Limited, to these Quality Management System Standards: ISO 9001:2000, ANSI/ASQC Q9001-2000, Approval Certificate No. 107563. 31524-US-090811 3

Notes NOTES 4 31524-US-090811

Table of Contents Table of Contents Revision History... 3 Table of Contents... 5 Wiring... 7 Current Loop Output... 9 Auxiliary Input Frequency Signal... 9 Relay... 9 RS-485... 9 Setup and Calibration... 11 Current Loop (analog output calibration)... 11 Set up 4 ma... 11 Set up 20 ma... 11 Select Linearity... 11 Calibrate Gauge... 12 Maintenance and Diagnostics... 15 Alarm Types... 15 Gauge Status... 16 Diagnostic Screens in Ohmview 2000... 16 Acknowledge Diagnostic Alarms... 16 Diagnostic Alarm Messages and Conditions... 16 Troubleshooting... 18 Test points... 18 LED Indicators... 19 Field Repair Procedures... 21 Replace CPU or Power Supply Board... 21 Periodic Maintenance... 21 Customer Service... 24 U.S., Canada, and Worldwide... 24 31524-US-090811 5

Notes NOTES 6 31524-US-090811

Wiring Wiring Follow the diagram and the steps below for wiring connections. 1. Make connections at the removable terminal strips mounted on the power board. 2. Access the power board by removing the explosion-proof housing cap. 3. Connect the power earth ground wire with the internal and external ground screw. 4. Access the ground screws by removing the top cover. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Interconnecting Terminals GEN2000 HART 1 Power In (L) 2 Power In (N) 3 Relay Normally Open (NO) 4 Relay Common (C) 5 Relay Normally Closed (NC) 6 Frequency + 7 Frequency - 8 + 6V Auxiliary Input Power (Not used in HART Applications) 9 Common 10-6V Auxiliary Input Power 11 Auxiliary Input Frequency Signal + 12 Auxiliary Input Frequency Signal - 13 Current Loop Output + 14 Current Loop Output 7 31516-US-090811

Wiring 1 2 1 Power Supply Board 2 CPU Board DSGH Exploded View 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DSGH Perforated View 1 Customer Earth Ground and Ground to Housing! CAUTION Do not apply power until thoroughly checking all the wiring. Not all connections are required for operation. For example, Terminal 10 (-6V, Auxiliary Input Power) may not be used with newer electronics. The power input terminals are not polarity-sensitive. The AC power source voltage input is 100-230 VAC ±10% (90-250 VAC) at 50-60 Hz, at 15 VA (or 25 VA with optional heater) maximum power consumption. Do not share the AC power with transient-producing loads. Use an individual AC lighting circuit. Supply a separate earth ground. 8 31524-US-090811

Wiring The DC power source voltage input is 20 60 VDC (<100 mv, 1-1,000 Hz ripple) at 15 VA maximum power consumption. DC power cable can be part of a single cable 4-wire hookup, or can be separate from output signal cable. Wire must meet power per local code. Use wire suitable for +40 C above surrounding ambient temperature. All field wiring must have insulation suitable for 250 volts or higher.! NOTE Not all connections are required for operation. The power input terminals are not polarity-sensitive. The HART signal may not operate with some isolating barriers or other non-resistive loads. Current Loop Output The current loop output signal is 4 20 ma into 250-800 Ω load. Pin 13 is positive (+) and Pin 14 is negative (-). HART communication protocol (BEL202 FSK standard) is available on these connections. The output is isolated to standard ISA 50.1 Type 4 Class U. When using signal (4 20 ma output) cables (customer supplied), they must meet these specifications: Maximum cable length is 3,280 ft. (1,000 m) All wires should be per local code When using DC power, the signal and power can run on a single cable 4-wire hookup (2 wires for power, 2 wires for 4... 20 ma). Auxiliary Input Frequency Signal Frequency input signal is 0 100 khz, true digital. Relay Relay contacts are rated at 6 A at 240 VAC, 6 A at 24 VDC, or 1/4 HP at 120 VAC. Frequency input signal is 0-100 khz, true digital. RS-485 The CPU board contains clearly labeled RS-485 connections. Use shielded wire per local code at a maximum length of 2,000 ft. (609 m). 1. Connect positive terminals together. 2. Connect negative terminals together. 3. Connect ground terminals together. 9 31516-US-090811

Notes NOTES 10 31524-US-090811

Setup and Calibration Setup and Calibration Before using the gauge to make measurements, you must: Calibrate it to relate the detection of radiation from the source to the level of the process material. Calibrate the current loop to a reference ammeter or the DCS. Current Loop (analog output calibration) Before completing a current loop calibration: 1. Connect an ammeter anywhere along the current loop (in series). 2. Make sure there is a 250-800 Ω load on the current loop. If no load or an insufficient load exists on the loop, it may require temporary placement of a resistor. 3. Hook the meter in series with the load resistor. 4. Open Ohmview 2000 Perform the following steps to calibrate the current loop. Set up 4 ma 1. Click Calibration, Current Loop Cal. 2. Click Execute. 3. Click OK. 4. Read the ammeter and enter the actual milliamp reading. 5. Click OK. 6. Click YES if the ammeter reads 4.00 ma or NO for any other reading. 7. Repeat until the meter reads 4.00 ma. 8. Read the ammeter and enter the actual milliamp reading. 9. Click OK. 10. Click OK. Set up 20 ma 1. Read the ammeter and enter the actual milliamp reading. 2. Click OK. 3. Click YES if the ammeter reads 20.00 ma or NO for any other reading. 4. Repeat until the meter reads 20.00 ma. 5. Read the ammeter; enter the actual milliamp reading. 6. Click OK. 7. Click OK. Select Linearity The majority of density applications use the equation linearizer to calculate the process value. For density applications, the equation is the default and we recommend it in most circumstances. If the results from the equation linearizer method are not satisfactory, contact Ohmart/VEGA Field service to explain the other options. The linearizer equation calculates a density reading for a given 11 31516-US-090811

Setup and Calibration count reading at the detector. To make the correct calculation, it relies on the following information: Vessel s inner diameter system parameter Span settings parameter Source type parameter Data used in the initial calibration Absorption co-efficient For information on linearity options, see the DSGH Installation and Operation Guide. 1. Click Setup, Gauge Setup, Linearizer Type. 2. Click Equation. Calibrate Gauge To calibrate your gauge, you must complete the Standard Method (2-point) or the Two-Point Process Calibration steps. Standard Method (2-point) 1. Set the low density and collect Cal Low data. 2. Set the high density and collect Cal High data. 3. Collect the linearizer table data. 4. Calculate the linearity. 5. Calculate the calibration. 6. Perform the data collection steps in any sequence, depending on your ability to empty and fill the vessel. To perform a calibration you must complete the following: 1. Click Equation from the Setup, Gauge Setup tab. 2. Check that the parameters (vessel inner diameter, engineering units, measurement span, and source type) are correct. 3. Start the gauge 4 hours before start of calibration. 4. Fill vessel or pipe with process. 5. Prepare to draw a sample while the gauge is collecting data. 6. Measure a process sample with the density gauge and enter the actual density.! NOTE The accuracy of the calibration depends upon the accuracy of the sample. Obtain an accurate reading, from a laboratory, of the sample read by the gauge. Two Point Process Calibration (Preferred Method) You must provide high and low process conditions when performing a two-point calibration. If using the standard method, record the sensor counts and levels at each step: Set Low Density 1. Click Calibration, 2 Point Calibration, Cal Low Collect. 12 31524-US-090811

Setup and Calibration 2. Click Start. 3. Click Accept. 4. Enter the actual process value (from the laboratory) in engineering units. 5. Click OK. Set High Density 1. Click Calibration, 2 Point Calibration, Cal High Collect. 2. Click Start. 3. Click Accept. 4. Enter the actual process value (from the laboratory) in engineering units. 5. Click OK. Collect Linearizer Table Data 1. Click Calibration, Linearizer Data Pt, Create Data Point. 2. At the prompt, enter the known process value. 3. Accept or reject the results when they appear. 4. Repeat the procedure for all available values Calculate Calibration 1. Click Calibration, 2 Point Calibration. 2. Click Calculate Results. 3. Click OK. 4. Click OK. One point process calibration The one point calibration measures one process sample. 1. Click Calibration, 1 Point Calibration. 2. Click Execute. 3. Click OK. 4. Click Start. 5. Click Accept. 6. Take a sample to the laboratory and return with a density process value in the proper engineering units. 7. Enter the sample density (PV) from the laboratory in the proper engineering units. 8. Click OK. 9. Click OK. 13 31516-US-090811

Notes NOTES 14 31524-US-090811

Maintenance and Diagnostics Maintenance and Diagnostics The transmitter system alerts you to detector problems by: Posting messages on the Ohmview 2000 message screen. De-energizing the output relay. Distinctly changing the current loop output. Tracking the current status and history in the Gauge status screens. Alarm Types Name Diagnostic Analog Process X-ray Description Diagnostic alarm provides information about level gauge system and alerts users when periodic procedures are due. Analog alarm sets the current loop ma to 2 ma or 22 ma when detector outputs zero (0) counts. If analog alarm is on, check the following: Is source holder shutter in On or Open position to create the required radiation field? Is there extreme build-up on walls or other material that is shielding detector from radiation field? Are electrical connections from sensor assembly to CPU board damaged or disconnected? Process alarm triggers when process level is above or below a set point (high limit or low limit). Enter choice of low or high limit and set point on Alarm Relay Setup tab. This alarm only works for output relay. The gauge acknowledges or resets process alarm when process value returns to set point value. X-ray alarm changes current loop ma output in response to marked increase in radiation field. This change prevents control problems when external radiographic sources are in the area during vessel inspections. Gauge sets current loop output at value measured 10 seconds before condition. Gauge cycles until radiation field is back to normal level or until a time-out period of 60 minutes passes. Alarm Output Diagnostic Analog Process X-ray Option to trigger relay Display HART message Optional Current loop output affected Gauge status and gauge history 15 31516-US-090811

Maintenance and Diagnostics Gauge Status Diagnostic Screens in Ohmview 2000 To check the system s present status, click Diagnostics, Diagnostics tab. For historical information, click the Diagnostic History and STDZ History tabs. Since some conditions are self-repairing such as RAM and EEPROM corruption, these conditions may appear in history screens, but not in diagnostic screens. Acknowledge Diagnostic Alarms Diagnostic alarms turn off when the problem resolves except for the following reasons: Source wipe due Shutter check due Standardize due! NOTE If the relay is set as a diagnostic alarm, you must acknowledge all diagnostic alarms to reset the relay. Diagnostic Alarm Messages and Conditions View active alarm messages on the Ohmview 2000 menu. Use the Alarms, Diagnostic Alarm Enable tab to select alarm messages. When a HART device initially connects to the gauge, any conditions in alarm appear. Condition Description Action RAM Status - Pass/Fail Sensor EEPROM - Pass/Fail Real Time Clock Status - Pass/Fail RAM corrupt/ram memory corruption occurred and resolved internally. Repeated triggering of alarm suggests hardware problem. Sensor EEPROM corrupt/ Critical memory corruption occurred on sensor pre-amp board EEPROM may not be resolved internally. If alarm recurs, suggests hardware problem. Real time clock failed/can cause miscalculation of timed events. Consult Ohmart/VEGA Field Service. Check for recurrence by acknowledging alarm. Cycle power to unit. If it recurs, contact Ohmart/VEGA Field Service. Reset time and date. Contact Ohmart/VEGA Field Service if clock does not reset. Note: If gauge has been without power for 28 days or greater, you 16 31524-US-090811

Maintenance and Diagnostics Sensor Temp Probe - Pass/Fail Source Wipe Due - No/Yes Sensor temp probe fail/sensor temperature probe may not be functioning, which results in erroneous measurements. Source wipe due must reset clock. Verify sensor temperature on Diagnostics, Process Chain tab. If temperature reads - 0.5 C constantly, probe may be broken and CPU board may need replacement. Contact Ohmart/VEGA Field Service. Perform source wipe. Log shutter check on Source Functions tab. CPU EEPROM - Pass/Fail CPU EPPROM corrupt/critical memory corruption occurred on CPU board EEPROM may not be resolved internally. If alarm recurs, suggests hardware problem. To check for recurrence, acknowledge alarm. Cycle power to unit. If it recurs, contact Ohmart/VEGA Field Service for advice. Sensor Status - Pass/Fail Sensor Voltage Status - Pass/Fail Standardize Due - No/Yes Shutter Check Due - No/Yes New Hardware Found - No/Yes Process Out of Range - No/Yes X-Ray Alarm - No/Yes Sensor fail/ Less than 1 count seen in last 10 seconds (configurable by Field Service.) Indicates sensor is malfunctioning. Sensor high voltage fail/high voltage on PMT is outside usable range. Standardize Due Shutter Check Due New hardware found?/cpu board detects configuration mismatch. CPU board or sensor assembly may have been replaced or one of EEPROM configurations is incorrect. Process out of measurement range/current process value is not within limits set by Max level and Min level in gauge span settings. Note that there are high levels of x-ray radiation in area that can affect process measurement. Contact Ohmart/VEGA Field Service. Contact Ohmart/VEGA Field Service. Perform a new standardization procedure. Perform shutter check. Acknowledge on Source Functions tab. Contact Ohmart/VEGA Field Service first. If they concur, click Diagnostics, New Hardware, No New Hardware and click OK. Contact Ohmart/VEGA Field Service. Contact Ohmart/VEGA for more information. 17 31516-US-090811

Maintenance and Diagnostics Troubleshooting Two circuit boards are field-replaceable. Test points Power Supply Board Power Supply Board and CPU Board Label H1 H2 TP1 TP2 Description HART connection HART connection Isolated ground Loop current test point 200 mv/ma loop current, referenced to isolated ground CPU board Label Count GND U5 pin 8 Description Raw input signal coming from the preamplifier Logic ground +5V power supply test point, referenced to logic ground 18 31524-US-090811

Maintenance and Diagnostics Jumpers Jumpers JP1 and JP2 on the power supply board set the current loop source or sink mode. The gauge does not use jumpers J1 through J4 on the CPU board.! NOTE Do not change the jumpers from the current setting without calling Ohmart/VEGA Field Service. Mode Gauge Current Loop Jumper Setting Source mode Self-powered JP1 Pins 1-2, JP2 Pins 2-3 Sink mode DCS-powered JP1 Pins 2-3, JP2 Pins 1-2 LED Indicators Power Supply Board LED Description Normal Condition Error Condition Recommendation +6V +6V DC voltage level to electronics ON OFF - electronics are not receiving +6 V DC required for functioning Verify +6 V on pin 8 of terminal strip (Pin 9 can be used as ground reference. Check fuse on power supply board. Check power input terminals 1 and 2. +24V Analog output loop voltage ON OFF - 24 V not present on 4... 20 ma output and HART communications are bad Check loop wiring and jumpers JP1, JP2 on power supply board. Replace power supply board. Relay Relay condition indicator ON - relay energized. OFF - relay de-energized None Check against relay output terminals 3, 4, and 5. If no relay output, replace power supply board. CPU Board Use the LED indicators on the CPU board to check the basic functioning of the gauge. They are visible when you remove the explosion-proof housing pipe cap. FIELD HV AUX CPU HART MEM FIELD HV AUX CPU HART MEM ON BLINKING OFF LED Indicators CPU Board 19 31516-US-090811

Maintenance and Diagnostics! NOTE If the LED band displays the Memory Corrupt pattern, call Ohmart/VEGA Field Service to report this condition. The gauge does not operate if the FLASH chip is corrupt. CPU LEDs Description Normal Condition Error Condition Recommendation Mem Memory corruption OFF Blink Pattern 1-CPU EEPROM corrupt 2-Sensor EEPROM corrupt 3-Both EEPROMs corrupt 4-RAM corrupt 5-Memory mismatch ON solid- Combination of errors Check software diagnostics. Call Ohmart/VEGA Field service. HAR T HART communication indicator ON - blinks when receiving HART messages None Check device and connection on loop CPU Central processing unit Blinks at rate of once per second LED does not blink. CPU not functioning Check power input. Replace CPU board. Aux Auxiliary input frequency signal indicator Blinks if auxiliary input is present None Check auxiliary input wiring terminals 11 and 12 with meter for frequency signal. Check auxiliary input equipment. HV Sensor high voltage On - high voltage is within specification Off-high voltage is outside of specification Call Ohmart/VEGA Field Service. Field Radiation field indicator Cycles in proportion to radiation field intensity at detector. On for 10 seconds for each mr/hr, then off for 2 seconds. (Use LED 5, which blinks 1 time/second to time LED1 for field indicator.) None Check for closed source shutter, buildup, and/or insulation. 20 31524-US-090811

Maintenance and Diagnostics Field Repair Procedures! CAUTION Use appropriate electrostatic discharge procedures to prevent damage to the electrical components of the gauge. Before replacing a circuit board, call Ohmart/VEGA Field Service. The sensor EEPROM contains a backup of the CPU board EEPROM. After replacing the CPU board, you must perform a memory backup to update the CPU board s EEPROM with the information in the sensor board EEPROM. Replace CPU or Power Supply Board 1. Turn off power to the gauge. 2. Remove the housing cover. 3. Remove the plastic electronics cover. 4. Remove the terminal wiring connector. 5. Remove the three (3) screws holding the electronics package in place. 6. Carefully pull the electronics package out of the housing. 7. Remove the appropriate board from the clamshell assembly by removing the three (3) mounting nuts.! NOTE If you are changing the CPU board, you must move the old firmware chip to the new board if the new board firmware is different. 8. Carefully reconnect any ribbon cables. 9. Install the electronics package in the housing. 10. Replace the three (3) mounting nuts. 11. Reconnect the terminal wiring connector. 12. Install the plastic electronics cover. 13. Install the housing cover. 14. Turn on the power to the unit. 15. Connect a HART communicator to the unit and verify that the unit is operational.! NOTE If you change the CPU board, a New Hardware Found error message normally appears when you connect with the HART communicator. In Ohmview 2000, click Diagnostics, New hardware, New CPU and click OK for a new backup of EEPROMS. Periodic Maintenance Follow this suggested schedule to prevent problems and to comply with radiation regulations. Recalibrate - As required by process conditions. Source holder shutter check - Every 6 months unless otherwise required by the appropriate nuclear regulatory body. 21 31516-US-090811

Maintenance and Diagnostics Source wipe - Every 3 years unless otherwise required by the appropriate nuclear regulatory body.! NOTE Refer to the DSGH Installation and Operation Guide and the Radiation Safety Manual for more information about recalibration and shutter checks and source wipe tests. 22 31524-US-090811

Notes NOTES 23 31516-US-090811

Customer Service Customer Service U.S., Canada, and Worldwide Within the United States, Ohmart/VEGA has Field Service Engineers available for onsite service, emergency services, or equipment start up. Contact Information Monday through Friday 8:00 A.M. - 5:00 P.M. EST (Eastern Standard Time) Emergencies: Follow the voice mail instructions Telephone Number/E-mail Address 1-513-272-0131 1-513-272-0131 International (Worldwide) 1-513-272-0131 Fax 1-513-272-0133 Field Service e-mail Nuclear Services e-mail fieldservice@ohmartvega.com nuclearservices@ohmartvega.com 24 31524-US-090811

4170 Rosslyn Drive Cincinnati, Ohio 45209 USA telephone: 1.513.272.0131 fax: 1.513.272.0133 web: www.ohmartvega.com e-mail: info@ohmartvega.com 31524-US-090306