Hand Chain (Model FCF) &

Similar documents
INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

MANUAL RESET ALARM RELEASE

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

MODEL B2 INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor

R OL L ING F IR E DOOR T E S T ING P R OGR AM

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

INSTALLATIONN GUIDE & OPERATION MANUAL

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

OWNER S MANUAL. Extended Performance Release Device. Models: Firefly III Plus, Firefly III Plus with Voiceboard

UL Revision 5. - Commercial Door Installations -

NFPA 80 Overview January 21, 2016

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

Panel Fan Series Operators Manual (Galvanized and Polymer)

ENGINEER S MANUAL No.01

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Operator s Manual. Model: TX31 Mini Round Baler. ibexequipment.com IBEX

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Besam SW200i-Fold Folding Door Series. Owner s Manual

FM-200 In-Cabinet Series

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

USER'S MANUAL PGE Single Package Rooftop

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

Deluxe Welding Tool Chest

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Hickory Rotisseries. Machine Type N / 5. 5 E 200ºF - 550ºF. Final Inspection:

MINI BLINDS Classic GETTING STARTED STANDARD HARDWARE. A few simple tools are required: OPTIONAL HARDWARE

Los Angeles Abrasion Machine HM-70A & HM-70AF

Telecab Residential Elevator OWNER S MANUAL

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

OPERATING INSTRUCTIONS MIGHTYLAM 2700 ROLL LAMINATOR

SECTION OVERHEAD COILING FIRE DOORS

M5 BLUE BOY FIVE GALLON PAINT MIXER Owner s Manual

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

OPERATING MANUAL. Los Angeles Abrasion Machine. PHONE: FAX: Website:

OPERATOR S MANUAL. For BURLY ATTACHMENTS

Telecab17 Residential Elevator OWNER S MANUAL

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SafEye Quasar 900 Open Path Gas Detector Quick Start Guide Installation and Calibration Procedure

Installation. Built-in Full Height Wine Cellar VCWB301

PATTERSON FAN MANUAL. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

Viking Installation Guide

Roll Heated Flatwork Finisher

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Feed Table FT42. Operator s Manual

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

User Manual Box Exhaust Fan Series (Belt Drive)

INSTANT HOT WATER DISPENSER

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

OWNER S MANUAL MODEL FDCL C

Swinging Egress and Fire Doors

Ice Pro DB1000 Series Automatic Ice Bagging and Dispensing System

Installation & Operating Guide

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

Patterson Fan Manual. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product- Examination.

Projector. Flush Mount

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Service Manual Electric Cooktop

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

SECTION Overhead Coiling Doors

IMPORTANT SAFETY INFORMATION:

PLC-1700 Series PLC-1710, , 1760, , 1760L

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

TOOLS AND MATERIALS REQUIRED

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Installation & Operating Guide

IMPORTANT SAFETY INFORMATION:

Transcription:

Hand Chain (Model FCF) & Hand Crank (Model FKF) INSTRUCTION MANUAL 0

WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. Maximum fire protection is provided when installed in accordance with factory specifications with provided fuse link systems. 2. Installation and testing to factory specifications shall be performed by factory authorized personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), local, state, county, district and/or other applicable building and fire standards, guidelines, regulations and codes including, but not limited to, all appendices and amendments and the requirements of the local Authority Having Jurisdiction (AHJ). 3. Installation to be performed by factory authorized door system technicians only. 4. Clear fire door opening and prohibit all traffic through door opening during system testing! INTRODUCTION The closing system is designed to be used in conjunction with a temperature activated fusible link arrangement. It is designed for use on rolling fire doors and counter fire doors. Optionally, the unit is designed to accept a bolt-on, fail-safe floor level reset or automatic reset release device for connection to local detectors or a central alarm system. 2

IMPORTANT MECHANICAL INSTALLATION PROCEDURE WARNING - To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2. Spring tension must be adjusted to allow the fire door to self close during a drop test. A door that is operating improperly could cause severe injury. Have qualified door system technicians make repairs to spring assemblies and other hardware before installing the operator. 3. Cover any exposed, moving operator parts that are less than 8 feet above the floor. 4. When utilized, locate the push to close control station: (a) within sight of the door, (b) at a minimum height of 5 feet so small children cannot reach it, and (c) away from all moving parts of the door. 5. Instruct the end user on proper operation of the operator. 6. The door is under extreme spring tension. Have qualified door system technicians make all necessary adjustments and repairs to the door. 7. When utilized, read and understand the wiring diagram of the alarm release device box. 8. For products having a manual release, instruct the end user on the operation of the manual release. 3

INSTALLATION INSTRUCTIONS INSTALLATION POSITIONS LH RH (Installation Illustration for FCF) LH RH (Installation Illustration for FKF) Consult factory for changes in installation positions. 4

OPERATOR MOUNTING 1. Before the operator is installed, verify that the door is properly operating and balanced. 2. Make sure the mounting plates are correctly positioned for RH or LH mounting. 3. Attach and tighten the mounting hardware to the mounting plate. 4. Tighten the operator mounting plate to the door. 5. When the operator is mounted on the bracket, be sure the door sprocket is properly aligned / in the same plane with the operator drive sprocket before securing to the shaft. 6. The shelf or bracket must provide adequate support for the operator. Prevent play between operator and door shaft. Permit operator to be fastened securely and with the drive shaft parallel to the door shaft. 5

Bracket Door Sprocket View "B" Door Sprocket Operator Drive Sprocket B View "B" View "A" View "A" Correct A Drive Sprocket Incorrect * Chain hoist shown. Hand crank similar. ADJUSTING THE DRIVE CHAIN NOTE: Use correct type, size and proper length of roller chain. 1. Adjust the drive chain by tilting or move the operator so that there is about 1/4 of slack when the chain is depressed. 2. Once the drive chain has been tightened, then tighten the operator mounting screws. LH RH S1. S2 Door Sprocket Drive Chain S1 S1 Drive Chain Door Sprocket 1/4" 1/4" Drive Sprocket S2 S2 Drive Sprocket 6

ADJUSTING OPERATING CHAIN LENGTH (FCF units only) Operating chain is provided in a standard length. Depending on door height, the chain may need to be shortened or lengthened. A DIFFERENT COLOR connecting link can be found in the hand chain. Use this link for breaking the chain to make adjustments to the hand chain length so that the bottom of the hanging chain is 2 to 3 above the floor. CHAIN HOLDER Install at a convenient location. Chain Holder Optional 7

IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with door controls. 3. Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. 4. KEEP DOORS PROPERLY OPERATING AND BALANCED. See Door Manufacturer s Owner s Manual. An improperly operating or balanced door could cause severe injury or death. Have trained door systems technician make repairs to cables, spring assemblies, and other hardware. 5. SAVE THESE INSTRUCTIONS. OPERATING INSTRUCTIONS FCF Pull operating chain to open and close door. To stop door, let go of the chain. FKF Turn crank to open and close door. To stop door, stop turning. 8

FUSIBLE LINK CONNECTION REMOVE COTTER PIN FROM RELEASE ASSEMBLY. Consult NFPA-80 and the authority having jurisdiction for fusible link location(s) and method. PLUNGER Remove cotter pin after connection of fusible link. RELEASE LEVER FUSIBLE LINK MAINTENANCE INSTRUCTIONS 9

The brake is a self-adjusting brake. It is maintenance free. The brake assembly requires no additional adjustment during its lifetime. WARNING If optional alarm release box is used, then disconnect alarm power supply to the alarm release box before servicing. Check the following items at the intervals listed: CHECK LIST DESCRIPTION EVERY 3 MONTHS EVERY 6 MONTHS Fasteners Check & tighten as required EVERY 12 MONTHS Drop-test Inspect door, drop-test for proper operation and full closure per NFPA-80 Inspect and service whenever a malfunction is observed or suspected. Before servicing, always disconnect power supply to the alarm release box, if provided. All replacement parts must be obtained from the door manufacturer per NFPA 80. Testing of the FCF and FKF are independent of, and shall in no way be interpreted as an alternative method of testing the fire alarm system, and/or any other system component employed on the fire door or counter fire door installation. TESTING SHALL BE PERFORMED AND WITHNESSED FOR PROPER OPERATION. 10