Forehead Thermometer Instruction Manual

Similar documents
Dual-Mode Infrared Thermometer Instruction Manual

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

Forehead Thermometer Instruction manual

CLETEF-786. Infrared Thermometer Instruction Manual

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

Instructions. Consumer Info-Line

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Forehead Infrared Thermometer

Kinsa Smart Ear ThermometerTM Instructions For Use

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

No Touch Thermometer

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

NON-TOUCH THERMOMETER User Manual

CareTemp Touch Free Thermometer. Directions for use

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

AlcoBlow. User Handbook

High Temperature InfraRed Thermometer with Laser Pointer

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

THERMOFOCUS 0800H5 Professional

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

I/R Thermometer Gun 12:1

WBGT Heat Stress Meter

USER GUIDE Heat Index Psychrometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer


Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

ELECTRONIC THERMOMETER. Model NTS-912 User Manual CONTENTS

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

Precision Infrared Thermometer. Users Manual

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Wet Bulb Thermo-Hygrometer Datalogger

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Model ST-128M Moisture Detector

USER MANUAL Digital CO Monitor Model CO30

Model S-530 Coin Sorter / Value Counter Operating Manual

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

Dual Laser InfraRed (IR) Thermometer

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

IRT2 Dual Laser IR Thermometer - User Guide

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

Soil Moisture Probe. Frizzell ltd. Owners Manual And Reference. Model SMP3A. frizzell ltd. Box 32 Kirwee Canterbury, 7543 New Zealand Ph:

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Dyna-Form Air. Alternating Pressure Relief Overlay System

Manual Hygrometer PCE-555

HIn3550 Magnetic Field Monitor User's Manual

62 MAX/62 MAX + Infrared Thermometer. Users Manual

WIRELESS MEASUREMENT SYSTEM OF GAS BOTTLES FILLING LEVEL WITH GAS LEAK DETECTION GMS 300. User Manual

USER MANUAL AND TECHNICAL MANUAL

Heart Rate Monitor MODEL: SE128 USER MANUAL

Dual Laser InfraRed (IR) Thermometer

EVac II Programmable Digital Vacuum Gauge

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

KANE-ALERT-CO 2 Monitor with Temperature

Instruction Manual Machine P/N: # & #

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

INSTRUCTION MANUAL. Model: 8918 THERMO HYGRO-ANEMOMETER KNT BF FPM MPH MS CKMH

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Indoor/Outdoor Temperature Alert

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

WIRELESS FRIDGE THERMOMETER Instruction Manual

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

OPERATING INSTRUCTIONS

User's Guide. Pinless Moisture Meter. Model MO257

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Thermometers & Instrumentation. Garden, Home & Leisure. Measuring Success

Precision Infrared Thermometer. Users Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

for a healthy world Product catalogue 2010/ 2011

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

DIGITAL BODY WEIGHT SCALES PS 4110

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

TOOLS AND INSTRUMENTS

ir-range 8G /03.15 Changes reserved.

Tower Ceramic Heater

COLOR WEATHER STATION. Item No Owner s Guide

High Resolution Display WIRELESS COLOR WEATHER STATION

Specifications Minimum Typical Maximum Unit

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Life Changing, Life Saving. The Vibby. User and Installation Guide

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

LD-5000 REFRIGERANT LEAK DETECTOR

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Transcription:

11/440/3 0088 Forehead Thermometer Instruction Manual Brannan Thermometers & Instrumentation Page 1

Contents Introduction 3 Advantages of the Forehead Thermometer 3 Operating Conditions 4 Storage and Shipping Conditions 4 Safety Instructions 4 Labelled Diagram 4 Battery Installation 5 Taking Temperature Measurements 5 Additional Tips to Achieve Accurate Measurements 6 Interpretation of Display 6 Checking Stored Readings 6 Changing Units C/ F 7 Error Messages 7 Technical specifications 7 After-sale service 8 Cleaning and Storage 8 Disposal 8 Legal Requirements and Guidelines 8 Page 2

Introduction Thank you for choosing this non-contact Digital Infrared Forehead Thermometer. To further ensure normal operation and accurate readings the product will self-test every time it starts up. Because of its clever design, non contact readings of body temperature can be taken which will not be unduly affected by variations in ambient temperature. The forehead thermometer can also be used to measure surface temperatures and has been specifically designed to measure the temperature of baby milk. In forehead mode the device provides measurements of body temperature between 32 C and 42.2 C (89.6 F to 107.9 F), and in milk mode surface temperatures between 0 C and 100.0 C(32.0 F to 212.0 F). Please read these instructions carefully before using the product and keep in a safe place for reference. Advantages of the Forehead Thermometer Ease of Use Taking measurements is quick, simple and non intrusive. Can measure both forehead temperature and the surface temperature of objects. Measurements can be taken while the patient is asleep. Stores 20 readings in the internal memory which helps track changes in the temperature of the patient. Device will warn user if the temperature of the patient is too high or too low. (see Fever Warning section) Safe and Hygienic Non contact measurements avoid the accumulation of bacteria, and reduce the need for cleaning and sterilisation during normal use. No danger from broken glass or swallowing the thermometer filling liquid (mercury or spirit). Robust ergonomic design manufactured from tough engineering plastics. More comfortable and convenient than anal and oral reading thermometers, especially for children Energy Efficient The device will automatically switch off after 10 seconds of inactivity. Page 3

Operating Conditions Temperature: 10 C to 40 C Humidity: <80% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa Storage and Shipping Conditions Temperature: -10 C to 60 C Humidity: 0-95% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa Safety Instructions This device is not suitable for use with newborn babies and children should always be supervised when using this device to avoid damage and/or misuse. The device takes spot temperatures only and is not suitable for continuous monitoring. Do not submerge in water or other liquids. Cleaning and disinfection procedure shall comply with the instructions specified in cleaning and storage. This thermometer consists of a number of precision parts which are vital to its reliability and repeatability. Handle with care and do not drop as the device is not designed to withstand intense shock or vibration. Do not twist the forehead thermometer or the temperature sensor. Please do not use the product if the temperature sensor or the forehead thermometer shows any sign of damage and do not try to repair the product. Contact S. Brannan & Sons for assistance. All readings taken by this thermometer should be used as a guide only. If you are in any doubt regarding the condition of the patient you should consult your doctor without delay. Batteries should be inserted correctly to avoid damage to the device and removed if the thermometer is not likely to be used for a prolonged period. Labelled Diagram 1. Temperature Sensor 2. Forehead Temperature Button 3. Milk Temperature Button 4. LCD Display Screen 5. Battery Compartment Cover Page 4

Battery Installation 1. Push the battery cover horizontally in the direction of the arrow. 2. If using the thermometer for the first time, pull out the plastic tab to allow the batteries to make contact. 3. Insert two AAA batteries in the battery compartment matching polarities. Taking Temperature Measurements 1. Press button (2) and move the sensor slowly from side to side at a distance of 1cm to 6cm from the patients forehead. 2. The device will click and take readings as long as the button is kept pressed. 3. Release the button to display the maximum recorded reading. Note - The thermometer measures infrared energy emitted from the forehead which may vary. Measuring a single point may therefore result in a less accurate reading. Readings between 32 C / 89.6 F and 37.5 C / 99.5 F will be displayed and the backlight will turn green. The reading will be accompanied by a single long beep. Fever Warning - When the readings exceed 37.6 C /99.7 F, the product warns that the patient may have a fever by 7 rapid, short beeps and a red display. (If a normal body temperature is recorded, the signal is a long beep and the display will glow green.) Readings less than 32 C will be displayed as L with three short beeps and a red backlight. Readings greater than 42.2 C will be displayed as H with three short beeps and a red backlight. When the C symbol begins to flash, the device is ready to take another reading. 1. Point the sensor at the surface being measured from a distance of 1cm to 6cm and press button (3). 2. When the reading is complete, the device will beep and the maximum recorded reading will be displayed. To switch from one mode to another, the device should be allowed to switch off and then restart using either button 2 or 3, depending upon which mode is required. Page 5

Additional Tips to Achieve Accurate Measurements Ensure the temperature sensor is clear of dirt or dust. Ensure the forehead is clean and dry and the patients temperature has not been affected by exercise or extreme emotions prior to taking a reading. If the instrument or the patient has been transferred from one place to another where the ambient conditions are different, wait for minimum of 30 minutes before use. Do not hold the instrument for an extended period of time as it is highly sensitive to heat. Interpretation of Display Device is in Forehead Mode and reading is within the defined measureme range. Backlight will be green. Device is in Milk Mode and reading is within the defined measurement ran Backlight will be green. Maximum temperature recorded is higher than the defined measurement range. Backlight will be red. Maximum temperature recorded is lower than the defined measurement range. Backlight will be red. Checking Stored Readings To access stored readings, press button (3) for 4-8 seconds and the display will show - - - with a flashing M. Pressing button 3 again will display the number 1 and then the last reading stored. Repeated pressing of button 3 will display the last 20 recordings taken. The data shown is forehead readings only, milk temperatures are not stored. If repeated pressing of button 3 does not scroll through the readings, then no readings are stored at that time. Page 6

Changing Units C/ F To change the temperature units, press button (3) for 8-12 seconds and the display will first show - - - with an M before showing - - - with a flashing C. Pressing button 3 again will change the units from C to F and vice versa. The units will change each time button 3 is pressed within 5 seconds. Having changed the units the device will start up in Milk Mode. If forehead readings are required the device should be allowed to power down and be started in forehead mode by pressing button 2. Error Messages Ambient temperature has exceeded 40.0 C /104 CF or dropped below 10.0 C /50.0 F. EEPROM data reading error or the correction process is not finished. Please contact your supplier. Replace batteries. Technical specifications Model Number(s) Forehead thermometer 11/440/3 Temperature Units C / F (Switchable) Measurement Range Forehead temperature mode: 32.0 C to 42.2 C (89.6 F to 107.9 F) Milk temperature mode: 0.0 C to 100.0 C (32.0 F to 212.0 F) Precision +/- 0.2 C (+/- 0.4 F) Resolution 0.1 C / F Response Time 1 sec Shutdown Time 10 sec +/- 1sec Batteries 2 x AAA (Battery life average1000 operations) Power supply rating BF It is recommended that professional users calibrate the device every two years as a minimum. Page 7

After-sale service The device is under warranty for two years from the date of purchase and will be repaired or replaced free of charge during this period. Damage caused by improper use and consumable items such as batteries and packaging are not covered by this warranty. Cleaning and Storage The infrared sensor is the most precise part and must be protected carefully. Clean the device with a cotton bud lightly moistened with 70% alcohol. Do not clean the device with corrosive detergent. Keep the device away from water or other liquid. Store the device in a dry environment, and keep it away from dust and direct sunlight. Disposal Please dispose of the used product and batteries in accordance with local regulation requirements. Legal Requirements and Guidelines This product complies with the European Directive for Medical Devices 93/42/EEC and carries the CE mark. The device also complies with the specifications of the European Standard for clinical thermometers-part 3: Performance of compact electrical thermometers (non-predictive and predictive) with maximum device. The CE marking confirms that this is a medical device with a measuring function in the sense of the Medical Devices Act, which has undergone a conformity assessment procedure. A notified Body confirms that this product fulfils all the appropriate statutory regulations. S. Brannan & Sons Ltd. Leconfield Industrial Estate Cleator Moor Cumbria CA25 5QE England www.brannan.co.uk Tel. +44 (0) 1946816600 Fax +44 (0) 1946816625 Email: sales@brannan.co.uk Rev. 1/2014 Page 8