The EZEtemp Single-Use Clinical Thermometer. A Few Simple Instructions

Similar documents
Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

Connex Integrated Wall System 2.2 Software Version

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

CLEO VERSATILITY IN VITAL SIGNS

Forehead Thermometer Instruction Manual

Instructions. Consumer Info-Line

No Touch Thermometer

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

Screen for carbon monoxide poisoning instantly to help safeguard your staff with the ToxCO range

Dual-Mode Infrared Thermometer Instruction Manual

User s Manual Warm N Cozy

AlcoBlow. User Handbook

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

OMNI Express VS VERSATILITY IN VITAL SIGNS

4/8/2014 GOAL PATIENT EQUIPMENT

THERMOFOCUS 01500A3 THERMOFOCUS

WIKA Instrumentation (M) Sdn Bhd. Safe and Uncompromising. Easy Testing within the Process - Testing and Calibration Technology.

American Red Cross Rapid Ear Probe-

VAPOR CONTROL SYSTEMS FOR ULTRASOUND

Indoor/Outdoor Temperature Alert

AE300. Integrated Voice Alarm System

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Counting Scales. HC-i Series.

NON-TOUCH THERMOMETER User Manual

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

Commodity Description

Atlas Monitor Outline Train the Trainer

SENSOSCIENTIFIC DATA LOGGER USER MANUAL V

Laboratory Gas Sensor Solutions

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

PRO Installation. Thermostat Wi-Fi

Food Safety Audit Checklist What to Expect When Being Inspected

Forehead Thermometer Instruction manual

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER

for a healthy world Product catalogue 2010/ 2011

VS2000V Veterinary Vital Signs Monitor Operation Manual

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

Seil brs fire curtain

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

THERMOFOCUS 0800H5 Professional

Slide 1. Welcome to the on-line training course for Waste Management!

MyKi Care Thermometer (MCT 1.0) USER MANUAL

Instruction Manual for Bench-Top Cleaning Baths

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

BLOOD BANK REFRIGERATOR - BR Series

DINAMAP PRO Series V2 Monitor. Operation Manual

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

MaxCel PLANT GROWTH REGULATOR COMMERCIAL CAUTION KEEP OUT OF REACH OF CHILDREN READ THE LABEL BEFORE USING

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP

Ambulatory infusion pump for continuous, intermittent, TPN or PCA delivery.

CLETEF-786. Infrared Thermometer Instruction Manual

MATK-MEDS. UB Braunschweig

3.2. Household Chemical Emergencies

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Pharmacy Refrigerator

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

USER MANUAL AND TECHNICAL MANUAL

enviro iq Advanced Comfort Control and Energy Management for the Hospitality Industry

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

REA22 Room Temperature Controller

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

TruStability Board Mount Pressure Sensors

A MEMBER OF MUHIBBAH ENGINEERING

PRODUCT CATALOG. Insect Light Traps. For use in:

Complex Care Hub: Oral and Nasal Suctioning

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

A MEMBER OF MUHIBBAH ENGINEERING

SMD HOT TWEEZER. Instruction Manual

P200 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

PRO Installation. Touch Wi-Fi Thermostat

OPERATING INSTRUCTIONS. Dedicated Holding Bin DHB2-20CE & GB Series ELECTRICAL SPECIFICATIONS

Installation, Start-Up, and Operating Instructions

MedReady Set-up, Helpful Hints, and Solutions for Special Needs

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

INSTALLATION AND OPERATION MANUAL

Operating / User Manual

Body Fluid Clean Up Kit: Supplies to ensure personal protection from bloodborne pathogens and bodily fluids.

A basic introduction about the principles of humidity

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

Instruments. for hydroponics & horticulture 2016

The Straight Way K Sileo Series

TOOLS AND INSTRUMENTS

T34TM AMBULATORY SYRINGE PUMP

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Operating instructions Page 16. Refrigerator Read the operating instructions before switching on for the first time

Evaluation of the Incon TS-LLD Line Leak Detection System

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

PQS Independent type-testing protocol

Thermometers. for home & garden specialists lit in temperature t measuring equipment for 35 years

Electrical Installations Design, Selection, Erection and Inspection

Transcription:

The EZEtemp Single-Use Clinical Thermometer A Few Simple Instructions Handling How to use with the patient Reading & recording temperatures General Info Safety Accuracy Shelf life Storage

HOW TO USE PREPARATION Wash your hands. Open the clinical box and remove a perforated thermometer strip. Tear away 1 clinical thermometer at the perforation. Peel apart the wrapper end by the arrow. Remove thermometer by pulling on the handle. Discard wrapper

HOW TO USE TAKING THE ORAL TEMPERATURE THE PATIENT Have patient open mouth and place the grid end of the thermometer far back in mouth under tongue. The grid end of the thermometer should be positioned in the heat pocket as per the diagram on the left. Make sure patient s mouth is fully closed and they are breathing through their nose. With mouth closed, patient should be instructed to press their tongue against the thermometer. This helps the thermometer to quickly warm up to body temperature.

HOW TO USE TAKING THE TEMPERATURE THE TIMING Begin timing the temperature. Wait at least 60 seconds. If you require reading glasses to see the thermometer s scale, then have them ready for use. After at least 60 seconds has elapsed, remove thermometer from patient s mouth. READ THE TEMPERATURE SCALE IMMEDIATELY (the thermometer will begin to reset itself when removed from the mouth). If necessary, re-take the temperature, using same unit (for the same patient only).

HOW TO USE READING THE THERMOMETER Remove thermometer from patient s mouth. Read & note the last black dot in grid tip of thermometer. This last black dot is the oral temperature reading.

THE THERMOMETER TIP HOW TO READ AND INTERPERET THE THERMOMETER GRID Each thermometer has a grid of temperature dots. Each dot represents a different temperature and turns black when a specific temperature is reached for that dot. The black dot with the highest temperature represents the patient s oral temperature. 1 2 3 No Reading 37.5 C 38.1 C

THE THERMOMETER TIP THERMOMETER GRID IN DETAIL Rows are in one-half degree C. increments. Columns are in 1/10 th of a degree C. increments. The black dot with the highest temperature is the actual oral temperature reading. See example below: Rows start with a whole number or.5 Each column represents 1/10 th of a temperature degree C..5.6.7.8.9.5.6.7.8.9. 0.1.2.3.4. 0.1.2.3.4. 0.1.2.3.4.5.6.7.8.9.5.6.7.8.9.0.1.2.3.4.0.1.2.3.4.5.6.7.8.9.5.6.7.8.9 37.5 C 38.1 C

KEEPING A RECORD NOTE THE TEMPERATURE WRITTEN RECORD If you need a written record of the temperature, record it now. If the temperature needs to be re-taken, put the same thermometer in the same patient s mouth and repeat the process. When finished, discard thermometer.

ALTERNATIVE METHODS Axillary Temperature Measurement (under arm) Place the dot end of the thermometer at the fold in the patient s armpit, with the dot grid against the torso. The handle of the thermometer should point toward the patient s feet, parallel with the body. Instruct the patient to close their arm to hold the thermometer in place. Wait at least 3 minutes. Remove thermometer and READ IMMEDIATELY.

ALTERNATIVE METHODS Rectal Temperature Measurement Insert the EZEtemp Oral Thermometer into the rectal sheath, with the dot end of the thermometer placed at the rounded end of the sheath. Insert the rounded end of the rectal sheath into the rectum until the dot-matrix and all of the numbers are completely covered. Wait at least 3 minutes. Remove sheath/thermometer and READ IMMEDIATELY.

SUMMARY EZEtemp Thermometers are Easy to Use 1. Place Thermometer under tongue in heat pocket. 2. Wait at least 60 seconds. 3. Read the last black dot for temperature. 4. Record the temperature if this is part of your protocol. 5. Properly dispose of the thermometer when done. For further assistance, please call our distributer Tel : 603-77843918, 603-77840053,

EZEtemp Clinical Thermometer by G H Zeal Ltd. Carries FDA (US Food & Drug Administration) & CE Certifications. Used by hospitals & clinics worldwide. A proven and accepted medical device. When used as a disposable device, reduces the opportunity for germ transmission between people. Accurate to 1/10 th of a degree Celsius. Never requires calibration or adjustment. Completely safe and non-toxic for users. No poison or contamination hazards. Completely safe for the environment. No mercury. No batteries. No special storage or handling requirements. Best if stored in a cool dry place. Not damaged by heat or cold. Maintains its accuracy in a wide range of conditions. Long life 5 years from the date of manufacture.

THANK YOU ZEAL The genuine article since 1888 Distributer : Ansari Agencies SDN.BHD. 18-A, 1st Floor, Jalan MJ/ 7, Medan Maju Jaya, 7th Mile Off Jalan Klang Lama, 46000 Petaling Jaya, Selangor, Malaysia. Tel : 603-77843918, 77840053, Fax : 603-77844135 E-mail : anslab@tm.net.my, anslab@streamyx.com web : www.anslabzeal.com