DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

Similar documents
Compressors, Chillers & Condensers

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

1.2 REFERENCES - comply with the following codes and standards:

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

High Capacity Instantaneous Steam Fired Water Heater

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Call us today! (800)

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

Call us today! (800)

CO 2 EVAPORATOR DESIGN

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

ParaWeld Plate Heat Exchangers

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

REFRIGERATION PRODUCTS

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

ParaWeld Plate Heat Exchangers

In-Line Air Separators

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Circulation Heaters Selection Guidelines

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Call us today! (800)

SAMPLE SPECIFICATIONS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION DOMESTIC WATER HEATERS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

Technical Development Program

Centrifugal Blowdown Separators and Tanks

Performance Requirements for Air-Cooled Condenser

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

SOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER

(2) 325 tpd York Chlorine Liquefier Systems

SECTION PLUMBING EQUIPMENT

MACH N-407 Heat Pump Air-Cooled Chiller

Circulation Heaters Selection Guidelines

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Aldrich Blowdown Separators & Cooling Manifolds

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

.2 Section Waste Management and Disposal.

Case 6 Impact of Fouling Factor and Special Material for Heat Exchanger

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

PDF Created with deskpdf PDF Writer - Trial ::

c o n d e n s e r Glossary of Terms

F4060 RESILIENT SEATED GATE VALVES

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

REFRIGERATION PRODUCTS

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

SCROLL COMPRESSORS TYPE AIR COOLED PACKAGE CHILLERS

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

R22 R407C. 60Hz. ACHDX Series. 225 to 415 Tons. Air Cooled Horizontal Rotary Screw Chillers. Products That Perform...

INDUSTRIAL HEAT EXCHANGERS

SECTION AIR COOLED WATER CHILLERS

Cascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Product Chillers A P P L I C AT I O N S

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

SB Series Brazed Plate Heat Exchanger Installation Manual

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

MAC N-407 Air-Cooled Chiller

MANUFACTURED with high-quality components and innovative techniques. DESIGNED for economical, trouble-free performance and long-life reliability

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

GLOBAL FLOW PRODUCTS

Walk-in Refrigerated Rooms. An Overview of Requirements, Options and Construction Details

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

XLP2 Evaporative Condensers

TECHNICAL BID EVALUATION SCOPE OF WORK COMPRESSED AIR SYSTEM

Quality Enclosures. Service Excellence.

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

SINCE Heat Exchangers. Plate and Frame FFW AHRI. Shell and Tube W & S. Brazed FFB cat-2016-he

Tradition & Technology

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

DESIGN STANDARDS SECTION 15600

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

Shell & Tube Heat Exchangers

OIL SEPARATORS APPLICATIONS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Product Data. Features/Benefits. 16JB Steam/Hot Water Single Effect, Hermetic Absorption Liquid Chiller 50/60 Hz

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design

SECTION AIR COOLED WATER CHILLER

SECTION ROTARY-SCREW WATER CHILLERS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Thermal Fluid Heaters

Transcription:

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR INTRODUCTION Dolphin offers Shell & Tube Evaporators. These components utilize the latest technology tubing available. FRESH WATER DX SHELL & TUBE EVAPORATORS Dolphin Evaporators are designed specifically for refrigerant evaporation. Refrigerant R-22 boils rapidly against the surface, reducing the overall vessel size. The evaporators are carefully engineered to provide excellent heat transfer rates, effective refrigerant boiling and assured oil carry-through. Shell circuits are engineered to provide high performance with a low pressure drop to conserve the required pumping power. The Direct Expansion Evaporators are designed for optimum heat transfer rates and features rolledin copper tubes and removable heads. Shell side baffling is selected for high operating efficiency and reasonable fluid pressure drops. Compliance with the ASME codes and quality controlled manufacturing make the cooler suitable for a wide variety of virtually trouble free fluid cooling applications. FEATURES OF DOLPHIN SHELL & TUBE EVAPORATORS High performance tubes for more economical cooling Serviceable through tube design, removable heads Controlled refrigerant velocites for positive oil return and low refrigerant pressure drop Rolled-In copper tubes Shell side baffling provided for high operating efficiency and reasonable fluid pressure drops MATERIAL OF CONSTRUCTION The Dolphin Evaporator is a Direct Expansion liquid cooler. The heat exchangers are designed with removable heads and copper tubes for use with refrigerant R-22. The tube side of the heat exchangers are designed and tested according to ASME code. SHELL Stell pipe shells. Shells are shot blasted and cleaned before assembly. Diameter of the shell may range from 8 to 20 depending upon the tonnage (from 5 TR to 70 TR). Higher capacities are also possible, for other capacities, kindly provide the details on the form attached. TUBES Tubes shall be of copper diameter 3/8, ½, 5/8. Tubes shall be roller expanded into multiple grooved tube sheet holes.

TUBE SHEETS Tube sheets shall be flanged, carbon steel fabricated to ASME specifications SA 516-Gr 70. BAFFLES Hot rolled stell, galvanized plated for reduced corrosion. HEADES Fabricated ring and cover type steel heads to ASME Specification SA 516-Gr 70 or equivalent. GASKETS Die-cut medium density elastomer compatible with the refrigerant and typical oils used with the refrigerant. Gasketed joints to be adequate for pressure application and shall not leak (using a leak testing pressure) at established test pressure of 1.25 times design working pressure. CODES AND DESIGN PRESSURES The refrigerant side is constructed in accordance with the latest edition of ASME Section VIII, Division I for pressure vessels. Tube side (refrigerant side) design pressure is 250 psig at 100 o F. Shell side fluid design pressure is 150 psig at 120 o F TEST PRESSURE Both shell and tube sides of all Direct Expansion Evaporators are pneumatically tested at 1.25 times the design working pressure to comply with ASME code and assure reliable sevice. FINISH Exterior surfaces are painted with gray enamel paint. The surface shall be adequate to prevent rusting, can be used as a base for insulation adhesive or can be used as a primer.

PERFORMANCE DATA FOR FRESH WATER SHELL AND TUBE EVAPORATORS DOLPHIN ITEM #. RATED TONS WATER FLOW RATE, LPM WATER PRESSURE DROP, KPa DOL.EVA001 5 50.75 2.78 DOL.EVA002 10 101.70 4.20 DOL.EVA003 15 152.5 4.30 DOL.EVA004 20 203.4 8.20 DOL.EVA005 25 254.2 7.60 DOL.EVA006 30 305.0 7.20 DOL.EVA007 40 402.6 8.70 DOL.EVA008 50 508.4 10.73 DOL.EVA009 60 602.9 11.80 DOL.EVA010 70 703.35 8.30 a. R-22 Refrigerant, water on the fluid side b. Entering water temperature 12 0 C c. Leaving water temperature 7 0 C d. R-22 Evaporation temperature 2 0 C

DIMENSIONAL DATA (All Dimensions are in mm unless otherwise specified) DOLPHIN ITEM #. A B C D E F DOL.EVA001 8 840 25.4 25.4 12.7 31.8 DOL.EVA002 8 1300 38.1 38.1 12.7 50.8 DOL.EVA003 10 1350 50.8 50.8 19.0 50.8 DOL.EVA004 10 2000 50.8 50.8 25.4 63.5 DOL.EVA005 12 2000 50.8 50.8 25.4 50.8 DOL.EVA006 12 2000 76.2 76.2 25.4 50.8 DOL.EVA007 14 2000 76.2 76.2 25.4 50.8 DOL.EVA008 16 2000 76.2 76.2 25.4 76.2 DOL.EVA009 18 2000 76.2 76.2 25.4 76.2 DOL.EVA010 20 2000 101.6 101.6 25.4 76.2

QUOTE REQUEST FORM FOR FRESH WATER EVAPORATOR Evaporator To: From: Date: Subject: Customer: Contact: Phone/Fax: Address: Technical Details: (Please provide the data as much as possible) Load-Total Heat Rejection (Ton or kw): Refrigerant: Entering Water Temp.: Water Flow Rate: Max. Water Pressure Drop: Design Pressure (Tube): Evaporation Temp.: Leaving Water Temp.: Fouling Factor: Design Pressure (Shell): Design Temp.: Dimensional Limitations: Other Conditions: Original Manufacturer and Model Number: