INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

INSTALLATION INSTRUCTIONS

STORM COLLAR 3/4" AIR SPACE BACK AND SIDES 31 5 / / /16 LOUVERS ON MODEL 3601 ONLY AIR KIT K/O GAS LINE K/O OUTSIDE AIR (LEFT SIDE ONLY)

INSTALLATION INSTRUCTIONS

Peninsula woodburning fireplace. Models (V)PN36-A

INSTALLATION INSTRUCTIONS SAVE THIS BOOK

36" Open Corner Circulating (Louvered)

This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions.

Comfort. Wood burning Fireplace

INDOOR WOOD BURNING (V)G(36,42,50)A SERIES INDOOR/OUTDOOR WOOD BURNING (V)J(36,42,50) SERIES FIREPLACES WITH INSULATION

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

This wood burning fireplace complies with UL127- CAN/ULC-S610-M87 standard as a FACTORY BUILT APPLIANCE.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLATION AND OPERATION INSTRUCTIONS

RESIDENTIAL AND OUTDOOR WOOD BURNING FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS (V)S36 SERIES

INSTALLATION INSTRUCTIONS

WOOD BURNING FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS (V)B36, (V)B36I, (V)B36L, AND (V)B36LI

VB36 36 smooth face VB36I 36 smooth face with insulation VB36L, CWB36C 36 circulating VB36LI 36 circulating with insulation

MODELS (V)C42, (V)C42I, (V)C42H, (V)C42L, (V)C42LI, (V)C42LH AND CWC42C

MODELS (V)C36, (V)C36I, (V)C36H, (V)C36L, (V)C36LI, (V)C36LH AND CWC36C

SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48

SOUTHWEST FIREBIRD MFG Sonoran Model 36ST, 42ST

CPFS P INSTALLATION AND OPERATION INSTRUCTIONS. Pro Series Wood burning Fireplaces MODELS

CPFS INSTALLATION AND OPERATION INSTRUCTIONS

CPFS. Georgian Wood Burning Fireplace. Models. Georgian 36 Georgian 42 Georgian 50. Installation and Operation Instructions

CPFS. Indoor Wood Burning Fireplace. Models. Installation and Operation Instructions

CPFS. Indoor Wood-burning Fireplace. Models. Installation and Operation Instructions

MODEL CF CEILING SUPPORTED CHIMNEY

Astria Outdoor Wood Burning Fireplace

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

36" and 42" WOOD BURNING FIREPLACES INSTALLATION AND OPERATING INSTRUCTIONS

FIREBOX MODELS BVC-36Y, BVC-42Y and BVC-50Y

Owner s Manual Installation and Operation

Superior Outdoor Wood Burning Fireplace

TO DO IF YOU SMELL GAS

Owner s Manual Installation and Operation

BFC BFC36. Balanced Flue (Closed Combustion) Heat-Circulating Fireplace. Homeowner s Installation and Operating Manual. Model:

STANDARD SERIES INSTALLATION INSTRUCTIONS MODELS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

CPFS. Installation and Operation Instructions Comfort Flame Belmont Series Wood Burning Fireplace. Models

Woodburning Peninsula Fireplace Model: MPL11

CPFS. INSTALLATION AND OPERATION INSTRUCTIONS Comfort Flame Columbus Series Wood-burning Fireplaces MODELS

UVST (SMOOTH FACE) UVCST (HEAT CIRCULATING) INSTALLATION & OPERATING INSTRUCTIONS

BDM Direct Vent systems are for use with direct vent gas fired appliances.

B-VENT DECORATIVE GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

CPFS. INSTALLATION AND OPERATION INSTRUCTIONS Superior Pro Series Wood-Burning Fireplaces MODELS

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

CAUTION. DO NOT DISCARD THIS MANUAL Read, understand and follow these instructions for safe installation and operation.

CHIMNEYS AND VENTS CHAPTER 8

ODSR Series "A" Outdoor Woodburning Fireplace

SURE HEAT MANUFACTURING

PelletVent Multi-fuel venting system. UL 641.

Ventis Direct Vent. Installation Instructions

DO NOT DISCARD THIS MANUAL:

Heat-N-Glo. Installers Guide. Model: 8000TVC

Pellet Stove. Flex Pipe. Appliance Connector

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

P P Gas Fireplace. P See Thru

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

WRE3042WH P/N Rev. E 10/2015 REPORT NO

CAUTION. DO NOT DISCARD THIS MANUAL Read, understand and follow these instructions for safe installation and operation.

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

36 Elite Installation Manual

Heat-N-Glo Fireplace. Installers Guide. Model: GRAND-50

Installation Instructions

DIRECT-VENT GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

CAUTION FOR YOUR SAFETY

Quadra-Fire, a brand of Hearth & Home Technologies 1445 North Highway, Colville, WA 99114

CPFS. Comfort Flame Residential and Outdoor Wood-Burning Fireplace Model. Installation and Operation Instructions

SR/SC Series "A" Woodburning Fireplace

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

TO DO IF YOU SMELL GAS

2012 INTERNATIONAL FUEL GAS CODE VENTS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Owner s Manual Installation and Operation

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

CPFS. INSTALLATION AND OPERATION INSTRUCTIONS Blackstone Series Wood-Burning Fireplace MODELS

CAUTION. DO NOT DISCARD THIS MANUAL Read, understand and follow these instructions for safe installation and operation.

CHAPTER 8 CHIMNEYS AND VENTS

INSTALLATION AND OPERATING MANUAL

Heat-N-Glo Fireplace. Installers Guide. Model: BAYFYRE-TRS

CPFS. INSTALLATION AND OPERATION INSTRUCTIONS Superior Merit Series Wood-Burning Fireplace MODELS

FIREPLACE MODELS SB36 - SE36 SB42 SB36. SB42 Installation and Operating Instructions SE36

CHAPTER 8 CHIMNEYS AND VENTS

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

TO DO IF YOU SMELL GAS

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

INSTALLATION AND OPERATING MANUAL

Installers Guide. Model: CFX-DIAMOND

Mitchell Metal Products, Inc.

INSTALLATION INSTRUCTIONS

Owner s Manual Installation and Operation

STANDARD SERIES INSTALLATION INSTRUCTIONS MODELS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSTALLATION & OPERATING INSTRUCTIONS BC36C, BC36R WOODBURNING FIREPLACE

City Series CV40E Gas Fireplace

INSTALLATION AND OPERATING MANUAL

Installation Manual Installation and Appliance Setup

Transcription:

PENINSULA MODEL VPN36 3-SIDED, WOODBURNING FIREBOX INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers. FOR YOUR SAFETY Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable materials on or near the appliance. NEVER leave children unattended when a fire is burning in the firebox. WARNING: IMPROPER INSTALLATION, ADJUST- MENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY, PROPERTY DAMAGE, OR LOSS OF LIFE. REFER TO THIS MANUAL. FOR ASSIS- TANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER OR LOCAL DISTRIBUTOR. WARNING: THIS FIREBOX IS INTENDED FOR USE WITH WOOD, OR IF A VENT-FREE OR DECORATIVE GAS APPLIANCE IS INSTALLED, BURN PROPANE/ LP OR NATURAL GAS ONLY. CHECK LOCAL CODES PRIOR TO INSTALLATION DESA INTERNATIONAL, 2701 INDUSTRIAL DRIVE P.O. BOX 90004 BOWLING GREEN, KY 42102-9004 Model Serial No. Date Purchased 55505 Rev. B 07/99

1. INTRODUCTION... PG. 3 2. SELECTING LOCATION... PG. 3 3. CLEARANCES... PG. 4 4. FRAMING... PG. 4 5. HEARTH EXTENSIONS... PG. 5 6. OUTSIDE AIR KIT INSTALLATION... PG. 6 7. GAS LINE INSTALLATION... PG. 6 C O N T E N T S 8. CHIMNEY PIPE INSTALLATION... PG.7 9. FINISHING YOUR CHIMNEY SYSTEM... PG. 9 10. TERMINATIONS...PG. 11 11. FINISHING YOUR FIREBOX... PG. 12 12. OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS... PG. 13 13. REPLACEMENT & ACCESSORY PARTS... PG. 14 Ø15 O.D. Ø10 I.D. 22 5 /8 12 HEARTH AREA DIMENSIONS 12 22 3 /8 NAILING FLANGES 21 19 24 1 /2 29 1 /2 3/4 3/4 5/8 3/8 66 1 /4 48 1 /2 OUTSIDE AIR HANDLE OTHER SIDE 20 1 /2 37 1 /2 10 1 /4 11 1 /4 8 1 /8 7 3 GAS LINE CONDUIT 12 OUTSIDE AIR 36 1 /2 40 UL LABEL BEHIND DOOR ON SMOKE SHELF 24 NOTE: ALL DIMENSIONS IN THIS INSTALLATION MANUAL ARE IN INCHES UNLESS OTHERWISE SPECIFIED. 2 55505

INTRODUCTION Model VPN36 series is a woodburning firebox intended and approved for installation in either residential homes or buildings of standard construction. This wood burning fireplace complies with UL 127 as a FACTORY BUILT FIREPLACE and is listed and tested by Underwriters Laboratory Inc. This model is not for use in mobile homes. This firebox system requires the utilization of a Vanguard 10" double-wall, snap-lock flue pipe system. BRUSHED BRASS GLASS DOORS are standard with this firebox. Different style doors are offered as optional accessories (see last page). BE SURE TO CHECK WITH YOUR LOCAL BUILDING CODES FOR AREA REQUIREMENTS BEFORE INSTALL- ING THIS FIREBOX. The model's serial number and any other specific rating information may be found on the unit in the UL RATING PLATE located at the interior of the firebox's opening (see Figure 1, page 2). BEFORE YOU BEGIN Before beginning the installation of your firebox, read these instructions through completely. This firebox and its approved components are safe when installed and operated according to this installation and operation manual. Unless you use Vanguard approved components tested for this firebox, YOU MAY CAUSE A FIRE HAZARD! The DESA International warranty will be voided by, and DESA International disclaims any responsibility for the following actions: A) Modification of the firebox or any of the components manufactured by DESA INTERNATIONAL unless otherwise permitted by DESA INTERNATIONAL. B) The use of a firebox insert or any other component part not approved by DESA INTERNATIONAL in combination with a DESA INTERNATIONAL firebox. C) Installation and/or operation in a manner other than instructed in this manual. D) The burning of any other fuel not tested or approved by DESA INTERNATIONAL in this wood-burning firebox. PROPER INSTALLATION is the most important step in ensuring a safe and continuous operation of this firebox. Although grounding may not be required by code in your area, it must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANS/ NFPA 70-1987. This firebox is intended for installation in accordance with the National Fire Protection Association Standard for Chimneys, Fireplaces, Vents, and Solid-Fuel Burning Fireplaces, NFPA 211, and in accordance with codes such as the BOCA Basic/National Code, the Standard Mechanical Code, and the Uniform Building Code. NOTE: Installation and repair should be done by a qualified installer. The firebox and chimney system should be inspected and cleaned before use and periodically thereafter especially during heating season to ensure a safe operating system. This firebox is not intended to be used as a substitute for a furnace to heat an entire home. Use for supplementary heating only. SELECTING LOCATION To determine the safest and most efficient location for your firebox, you must take into consideration the following guidelines: 1. The location must allow for all the proper clearances (see section on clearances, page 4). 2. Consider a location where the heat output would not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. 4. If an outside air kit is to be installed, accessibility to outside combustion air must be considered. This can also be achieved through a vented crawl space in some cases, for more details refer to section on outside air kit installation. Figure 2 The typical installation for a peninsula is a projected installation, which allows you to extend the firebox any distance into the room. A projection may be ideal for a new addition on an existing, finished wall. 55505 3

ALSO IN SELECTING A LOCATION, THE FOLLOWING PRECAUTIONS MUST BE OBSERVED; 1. Do not connect this firebox to a chimney system other than a Vanguard chimney system. 2. Install in an area providing ventilation and adequate combustion air. 3. Due to high temperatures do not locate this firebox in high traffic areas or near furniture and draperies. 4. Provide adequate clearances around air openings into the combustion chamber. NEVER obstruct the front opening of the firebox or the flow of combustion and ventilation air. 5. Do not locate in or near an area where gasoline or other flammable liquids may be stored. The firebox area must be kept clear and free from these combustible materials. CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES ARE: BACK... 1/2" MIN. ADJACENT WALL... 12" MIN. CHIMNEY OUTER PIPE SURFACES... 2" MIN. BOTTOM OF FIREBOX TO FLOOR... 0" MIN. Figure 3 1/2 MIN. (3) 12 MINIMUM TO ADJACENT WALL SPACERS ON SIDES OF FIREPLACE PROVIDE REQUIRED 1/2" CLEARANCE WARNING: DO NOT BLOCK REQUIRED AIR SPACES WITH INSULATION OR ANY OTHER MATERIAL. DO NOT OBSTRUCT EFFECTIVE OPENING OF FIREBOX WITH ANY TYPE OF FACING MATERIAL. COMBUS- TIBLE MATERIAL MUST NOT BE IN CONTACT WITH THE BLACK FRONT FACE OF THE FIREBOX. MANTEL CLEARANCES Woodwork, such as wood trims, mantels, and other combustible materials, should not be placed within 9 inches of the effective opening of this firebox. The effective opening is considered the opening where actual heat output may occur. Combustible material above and projecting more than 1 1 /2 inches from the front face of firebox (see Figure 4) should not be placed less than 12 inches from the effective opening of the firebox (ref; NFPA std. 7-3.3.3.) DRYWALL COMBUSTIBLE MATERIALS ONLY BEYOND LIMITS SHOWN "FALSE" HEADER WITHIN 12" OF EFFECTIVE OPENING Figure 4 12" (NOM) 9" MIN. 1 1 /2" MAX. SEAL 3/8 GAP FROM TOP OF FIREPLACE TO DRYWALL WITH NONCOMBUSTIBLE CAULKING 11" MIN. TO HEADER 2" MIN. TO COMBUSTIBLES SPACERS 1/2" MIN. VIEW "A" VIEW "A" INSULATION (DO NOT REMOVE) FRAMING Construct framing using dimensions shown in Figures 5, 7, and 8, page 5, depending on your particular installation. If the firebox is to be installed directly on carpeting, tile (other than ceramic), or any combustible material other than wood flooring; the firebox must be installed upon a metal or wood panel extending the full width and depth of the firebox. Before securing firebox to prepared framing, metal safety strips (provided) must be placed between hearth extensions (not supplied) and bottom front edge of firebox to protect against glowing embers (Figure 6, page 5). If the firebox is to be installed on a raised platform, a "Z-type" metal safety shield (not supplied) must be fabricated to fit your required platform height (see Figure 7, page 5). The shield must be made of (26-28ga) galvanized sheet metal to prevent corrosion. 4 55505

TOP STUDS MUST CLEAR SPACERS ON TOP OF UNIT 1/2 MIN. TO COMBUSTIBLES 2 MIN. CLEARANCE FROM OUTER PIPE TO COMBUSTIBLES 22 5 /8 22 5 /8 39 7 /8 11 5 /16 Figure 5 48 1 /2 MIN. Figure 8 21 1 /2 Ø15 OUTER PIPE 1/2" (12.7mm) MIN. TO COMBUSTIBLES NAILING FLANGES Proceed to secure firebox to prepared framing at nailing flanges located at the sides of the firebox as shown in Figure 9. 1/2 MIN. OVERLAP 1/2 MIN. PREPARED FRAMING METAL SAFETY STRIPS (SUPPLIED) Figure 6 NAILS OR SCREWS Figure 9 HEARTH EXTENSIONS PLATFORM MUST BE SOLID, FLAT, AND FULLY SUPPORTED "Z" TYPE METAL SAFETY SHIELDS (NOT SUPPLIED) 48 1 /2 MIN. 39 7 /8 22 5 /8 A hearth extension is required to protect combustible floor surrounding firebox. You may fabricate your own per the dimensions shown in Figure 10, page 6. The hearth extension must project 20 in. min. to the front and 12 in. min. beyond each side of the firebox opening except on the end where projection is 16 in. min. to the front and 20 in. to the sides (see Figure 10, page 6). * Figure 7 AS REQUIRED BY DESIGN AS LONG AS CEILING CLEARANCE IS MAINTAINED 55505 5

NONCOMBUSTIBLE HEARTH EXTENSION SECURE TO COLLARS WITH DUCT TAPE OR SCREWS AIR INLET EYEBROW AIR INLET LOCATION MUST ALLOW FOR BUSHES OR SNOW Figure 10 64 MIN. 20 MIN. 16 MIN. 65 MIN. NONCOMBUSTIBLE HEARTH EXTENSION Figure 12 VENTED CRAWL SPACE INSTALLATION CHECK WITH LOCAL AREA CODES PRIOR TO INSTALLING IN A VENTED CRAWL SPACE Figure 11 1 1 /2" TYP 8" MAX "Z" TYPE EMBER PROTECTOR NONCOMBUSTIBLE HEARTH EXTENSION "K" FACTOR.84 1 1 /2" TYP EMBER PROTECTOR FOR RAISED FIREPLACE SEE SECTION ON FRAMING WITH A RAISED PLATFORM If a hearth extension is to be field constructed, it must be made of noncombustible, inorganic material having an effective thermal conductivity "K" of.84 BTU In/Ft 2 Hr. F or less at 1" thickness. Thermal conductivity "K" of materials can be obtained from the manufacturer. The minimum required thickness for any material could be obtained by the following formula: K factor x 1" = Thickness required.84 If the hearth extension is to be raised, a "Z" type metal safety strip must be used, see Figure 7, page 5 and Figure 11. OUTSIDE AIR KIT INSTALLATION The installation of the outside air kit must be installed during the rough framing of the firebox due to the nature of its location. Outside combustion air can be accessed through an exterior wall or a vented crawl space (see Figure 12). WARNING: AIR INLET DUCTS MUST NOT TERMI- NATE IN ATTIC SPACE. Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow, bushes or other obstacles. It should also be located beyond the reach of small children. The maximum height for the air inlet above platform of firebox is within 3 feet below the termination flue gas outlet. For further details on the installation of the outside air kit, please refer to the instructions included with the kit. For operating instructions, please refer to your owner s manual. GAS LINE INSTALLATION YOUR GAS SUPPLIER OR A QUALIFIED SERVICE PER- SON SHOULD DO GAS LINE HOOKUP. WARNING: BEFORE YOU PROCEED, MAKE SURE YOUR GAS SUPPLY IS OFF! A gas line may be installed for the purpose of installing a gas appliance available through your local distributor. Use only 1/2" black iron pipe and appropriate fittings. When installing a gas line, a shut-off valve designed for installation outside the firebox is recommended. STEP 1: To install, remove the knockout indentation on the refractory (or firebrick) wall located approximately 2" above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object until it is released. Remove fragmented portion of refractory (see Figure 13, page 7). 6 55505

OUTSIDE OF FIREPLACE GAS LINE CONDUIT REMOVE INSULATION TEMPORARILY (DO NOT DISCARD) Figure 13 OUTSIDE OF FIREPLACE GAS LINE CONDUIT REPACK INSULATION Figure 14 REMOVE KNOCKOUT AFTER REMOVING GAS LINE COVER PLATE, REPLACE SCREWS INCOMING 1/2" BLACK IRON PIPE 9 1 /4" (235mm) APPROX. SIDE FIREBRICK FINISHED SIDE REFRACTORY KNOCKOUT PLUG REMOVE BY TAPPING LIGHTLY WITH A 1/2" DOWEL STEP 2: Remove gas line cover plate on rear of firebox and pull out insulation from gas line conduit sleeve, save insulation for reuse. STEP 3: Run a 1/2" black iron gas line into the firebox through the rear at 11 1 /4" from the floor and through gas line conduit sleeve (if using a raised platform. Add height). Provide sufficient gas line into firebox chamber for fitting connection (see Figure 14). SIDE FIREBRICK FINISHED SIDE PROVIDE ENOUGH THREADED END FOR FITTING CONNECTION SEAL OPENING WITH REFRACTORY CEMENT NOTE: Secure incoming line to wood framing to provide rigidity for threaded end. STEP 4: Repack insulation around gas line and into sleeve openings. Seal any gaps between gas line and refractory knock out hole with refractory cement or commercial furnace cement. Install the decorative gas appliance or cap-off gas line if desired. WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. The gas pipe is intended for connection to an unvented gas log set or to a decorative gas appliance. If you will install an unvented gas log set, ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS, ANS/IAS/AGA Z21.11.2, ARE TO BE INSTALLED IN THIS FIREPLACE. NOTE: An appropriate Vanguard hood must be installed when using an unvented gas log set. WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE WITH THE CHIMNEY REMOVED. If you will install a decorative gas appliance, the decorative gas appliance must comply with the Standard for Decorative Gas Appliances for Installation in solid Fuel burning Fireplaces, ANS Z21.60-1996 and shall also be installed in accordance with the National Fuel Gas code, ANS Z223.1-1996. WARNING: WHEN USING A DECORATIVE APPLIANCE, THE DAMPER MUST BE REMOVED OR PERMANENTLY LOCKED IN THE FULLY OPEN POSITION. CHIMNEY PIPE INSTALLATION The Vanguard chimney system is a snap-lock, double-wall pipe. It consists of a stainless steel inner flue pipe, a galvanized outer pipe, and a wire spacer. Each section of pipe comes in lengths of 12", 18", 24", 36", and 48" but the actual lineal gain for each is measured after each section is fully connected. Lineal gain is the actual measurable length of a part after two or more parts are connected. LINEAL GAIN PART # NO. DESCRIPTION GAIN (inches) VPN36 PENINSULA 66 1 /4" FIREBOX V12-10DM FLUE PIPE 10 3 /8" V18-10DM FLUE PIPE 16 3 /8" V24-10DM FLUE PIPE 23 3 /8" V36-10DM FLUE PIPE 34 3 /8" V48-10DM FLUE PIPE 46 3 /8" VETL-10DM CHASE STYLE 7" to 17" TERMINATION VRTL-10DM ROUND TOP 6" TERMINATION PIPE INSTALLATION Place pipe assembly (inner and outer with wire spacer) over starting collar. Inner pipe fits inside inner pipe, outer pipe fits outside outer pipe. Begin by aligning hemmed-end of inner flue pipe into the inner starting flue pipe of firebox. Push down until hem "snap-locks" with lances. The outer pipe is just the opposite; female end has the lances. Continue the same procedure for the outer pipe (see Figure 15, page 8). 55505 7

HEMMED END 15" (381 mm) DIA. GALVANIZED OUTER PIPE 10" (254 mm) STAINLESS INNER PIPE LANCED SIDE UP Figure 17 SCREW (TYP. OF 8) ATTIC SPACE ABOVE CEILING FIRESTOP SPACER EXISTING CEILING FRAME Figure 15 It is important to assure that the joint between the chimney sections is fully locked. Check by pulling chimney upward after locking. The chimney should not come apart if properly locked. It is not necessary to add screws to keep vertical or angled chimney runs together. WARNING: THE OPENINGS AROUND THE START- ING COLLAR ON TOP OF THE FIREBOX MUST NEVER BE OBSTRUCTED. NEVER USE BLOWN INSULA- TION TO FILL THE CHIMNEY ENCLOSURE. SUPPORT SECTIONS The chimney support section is a 4 strap, 12-inch length of pipe. A chimney support is required every 30 feet above the firebox after a straight chimney run, or above a return elbow after a straight chimney run (Figure 18). This support is designed to relieve the extra weight load on the firebox and elbows when high chimneys are installed. V12S-10DM SUPPORT REQUIRED FIREBOX SPACER Firebox spacers are required at each point where the chimney penetrates a floor or ceiling, joist space. Their purpose is two fold; they establish and maintain the required clearance between the outer pipe and combustible materials, and they also serve as a shield between floors as required by most codes. When the pipe passes through a framed opening into a living space above, a firestop must be placed on the ceiling below (Figure 16). 30 FT. (9.14m) 30 FT. (9.14m) RETURN LIVING SPACE ABOVE CEILING EXISTING CEILING FRAME Figure 18 OFFSET INSTALLATION Chimney weight above offset rests on return elbow. Straps must be secured with nails to rafters or joists (see Figure 19). FIRESTOP SPACER 2" (50.8mm) MINIMUM Figure 16 SCREW (TYP. OF 8) When the pipe passes through a framed opening into an attic space above, a firestop must be placed on the attic floor above (Figure 17). STRAPS Figure 19 ANGLE FIRESTOP CEILING SUPPORT PIPE V12S-10DM RETURN 8 55505

To achieve desired offset, you may install combinations of 12, 18, 36, or 48 inch lengths of double wall pipe (see Figure 20 and Rise and Offset Chart). RETURN RETURN 6' MAX B 6' MAX OFFSET 6' MAX RETURN CEILING SUPPORT PIPE V12S-10DM 6' MAX 6' MAX 6' MAX OFFSET RETURN OFFSET Figure 20 A Figure 21 TYPICAL OFFSET INSTALLATIONS RISE AND OFFSETS A B 48 36 18 12 4 3 /8 16 3 /8 9 1 /2 25 1 /4 1 12 1 /2 30 3 /8 1 14 3 /8 34 2 17 5 /8 39 1 /4 1 1 21 1 /2 46 1 22 3 /4 48 1 /8 1 2 26 3 /8 54 7 /8 1 26 3 /8 60 1 1 31 3 /4 63 3 /4 1 1 34 3 /4 69 1 1 38 5 /8 75 5 /8 2 39 7 /8 77 7 /8 1 1 1 43 3 /4 84 1 /2 1 1 46 3 /4 87 3 /4 2 1 48 7 /8 93 3 /8 2 FINISHING YOUR CHIMNEY SYSTEM 10 FOOT RULE All chimney termination must extend a minimum of 3 feet above the highest point where it passes through the roof and must be at least 2 feet above the roof within a 10 foot horizontal span (see Figure 22). Figure 22 10' OR LESS 2' MIN. 10 FOOT RULE 3' MIN. LEVEL OF FLUE GAS OUTLET 10' 2' MIN. 3' MIN. IMPORTANT: If an exposed portion of chimney is greater than 4 feet above the roof line, use support wires to keep chimney secure. The support wires may be attached to the outer pipe of the chimney with screws, provided the screws do not penetrate the inner flue pipe. Maximum length of pipe between supports is 6 feet of angled run. A maximum of two 6 foot angled run sections per chimney system (see Figure 21). 55505 9

VSC-10 FLASHING VRTL-10D VRTL-10D VETL-10D MAXIMUM CHIMNEY HEIGHT The maximum height approved for any chimney run with this firebox system is 50 feet measured from bottom of firebox to flue outlet-end of pipe. CHIMNEY MAINTENANCE VFS-10DM MINIMUM HEIGHT 15 FT. Have your chimney system cleaned and inspected regularly to ensure safe and efficient operation. Refer to your Owner's Manual for further guidelines on maintenance and operation. Using Figure 24 and the chart below, determine the opening that will be required for the pitch of your particular roof. MAXIMUM HEIGHT CHASE TERMINATION 50 FT. 19" MIN. (482.6mm) 2" MIN. (50.8mm) 30" MIN. (762mm) 2" MIN. (50.8mm) VFS-10DM 2" MIN. (50.8mm) OPENING "A" Figure 24 V30FS-10DM Figure 23 V30E-10DM MINIMUM CHIMNEY HEIGHT The minimum chimney height (measured from bottom of firebox to flue gas outlet-end of pipe) is 15 feet for a straight run, 16 feet min. for a run with 1 elbow set (a set consists of one starter elbow and one return elbow). Uncommon circumstances such as neighboring hills, tall trees, or strong wind areas can cause downdrafts in the chimney system. In such cases going beyond the minimum recommended height would be preferable to provide a better draw. ROOF OPENING CHART PITCH OPENING "A" USE FLASHING NO. FLAT 19 V6F10 6/12 23 1 /4 V6F10 (26.6 DEG. SLOPE) 12/12 30 3 /4 V12F10 (45 DEG. SLOPE) Before cutting hole, temporarily remove shingles around area to be opened. After preparing the opening on the roof, continue to add sections of pipe until it extends a minimum of 30 inches above highest point of roof cutout (see Figure 24). With the termination the minimum height should add up 3 feet (see 10-Foot Rule and Figure 22). 10 55505

FLASHING INSTALLATION Determine the flashing to be used with the roof-opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles. DO NOT NAIL THROUGH FLASHING CONE. The terminations approved for this firebox are VRTL-10D which can be used for flashing or chase and VETL-10D for chase style termination only. Figure 27 shows an VRTL-10D round top termination. STAINLESS INNER FLUE PIPE VRTL-10D FLASHING STORM COLLAR CHIMNEY PIPE OVERLAP SHINGLES TOP AND SIDES ONLY SECURE TERMINATION TO OUTER PIPE WITH (3) SCREWS NAIL ONLY OUTER PERIMETER OF FLASHING OVERLAP SHINGLES (TOP AND SIDES OF FLASHING BASE) APPLY WATERPROOF CAULKING STORM COLLAR FLASHING UNDERLAP SHINGLES Figure 27 Figure 25 UNDERLAP SHINGLES AT BOTTOM STORM COLLAR INSTALLATION Place storm collar over pipe and slide down until snug against the open edge of the flashing (see Figure 26). CHIMNEY PIPE CAUTION: DO NOT SEAL OPENINGS ON THE ROOF- TOP FLASHING. FOLLOW THE INSTALLATION IN- STRUCTIONS PROVIDED WITH THE TERMINATION BEING USED. CHASE INSTALLATIONS Instructions for chase installations are included with the chase style termination chosen although it is worthy to mention here that in a multiple chase installation, provide adequate distance between terminations or smoke spillage from one termination to another may occur. We suggest they be separated at least 30" center to center and stacked at a vertical height difference of 18" vertically from one termination to the other (see Figure 28). Figure 26 Apply waterproof caulking to all seams and notched around storm collar and also at base around shingles. TERMINATIONS The firebox system must be terminated with the listed round top or chase terminations, In any case, refer to the installation instructions supplied with the termination. 30" MIN. 30" MIN. Figure 28 18" MIN. TYP. 55505 11

FINISHING YOUR FIREBOX CABINET DOOR INSTALLATION Brushed brass glass doors have been provided with this firebox. A set includes the front glass panel assembly. They come in different styles, check with your local distributor for availability and options. To install doors and front panel, simply insert top door pin(s) up into hole(s) on top frame, and insert bottom pin (D) into hole (S) on bottom frame until door is fully seated. No alignments or adjustments are necessary (see Figure 29). TOP SLOT UNDERNEATH FRAME Use only heat resistant, noncombustible mortar or adhesive when securing facing material to the front of the firebox. When placing facing at the upper edge of the effective opening of the firebox, provide an "L" shaped piece of metal extending the full width of the opening. Secure with sheet metal screws at a distance high enough from the edge as to not interfere with the operation of doors. This assures that the facing material, in time, should not block the opening if it were to lose cohesion. FLASHING MANTELS Mantels, combustible or noncombustible, may be constructed (see Figure 31), as long as the proper clearances are observed (refer to page 4 for clearance). ADJUSTMENT CLIP BOTTOM PIN SHORT PIVOT PIN BOTTOM SLOT Figure 29 ADJUSTMENT CLIP Figure 31 FIREBOX FACING Any noncombustible material may be used for facing (glass, title, brick, etc.) as long as the proper clearances are adhered to (refer to section on clearances) and the firebox opening are not blocked or obstructed in any way (see Figure 30). NONCOMBUSTIBLE FACING MATERIAL "L" SHAPED METAL SUPPORT NONCOMBUSTIBLE FACING MATERIAL DO NOT BLOCK EFFECTIVE OPENING Figure 30 12 55505

OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS GLASS DOORS Only the cabinet type doors can be opened, the front glass panel assembly is stationary and must be installed with doors. When firebox is in operation, both sets of cabinet doors on each side of firebox, must be in the FULLY OPEN or FULLY CLOSED position only or a fire hazard may be created (see Figure 32). CABINET DOORS MUST EITHER BE FULLY OPEN (AS SHOWN) OR FULLY CLOSED WHEN FIREPLACE IS IN OPERATION SIDE PANEL IS STATIONARY GRATE Figure 33 DAMPER CONTROL LEVER PULL DOWN TO CLOSE PUSH UP TO OPEN OUTSIDE AIR HANDLE PULL TO CLOSE PUSH TO OPEN Figure 32 CABINET GLASS DOOR (TYP. OF 4) DAMPER MECHANISM The damper control lever is located inside the fire chamber (see Figure 33). Make sure lever is cool before handling. Pull down to CLOSE, push up to OPEN. The damper must be open when lighting a fire; not doing so will cause smoke spillage into the room. When the firebox is not in use, close the damper to prevent downdrafts from entering room. The damper mechanism should be per the following figure. OUTSIDE AIR MECHANISM The outside air handle is located at the right hand side of the firebox rear refractor (Figure 33). Pull to close, push to open, Always open the mechanism when starting a fire, this provides adequate outside combustion air. Close the mechanism when not in use to prevent cold air from entering the room. Periodically check your outside air intake vent hood for any possible obstructions (snow, bushes, etc.). GRATE The grate is designed to provide you with the maximum solid fuel capacity, do not attempt to defeat its purpose, doing so may cause smoke spillage and may cause a fire hazard. Do not overload the grate or obstruct the required air space beneath it. Always keep ashes from building up under the grate. WARNING: RISK OF FIRE! REPLACE GRATE WITH VANGUARD MODEL 36PNGR GRATE ONLY. Never obstruct the flow of combustion and ventilation air. Keep the front of the firebox clear of all obstacles and materials. WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND TO STAY AWAY FROM THESE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SU- PERVISED WHEN THEY ARE IN THE SAME ROOM AS THE FIREBOX. FOR FURTHER OPERATING GUIDELINES, INSTRUC- TIONS AND WARRANTY INFORMATION PLEASE RE- FER TO YOUR OWNER'S MANUAL OR CONTACT YOUR AUTHORIZED DEALER. 55505 13

REPLACEMENT AND ACCESSORY PARTS Purchase replacement parts or accessories from your local dealer. If they can not supply these accessories, call DESA International's Parts Department at 1-800-972-7879 for referral information. You can also write to the address listed on the front cover of this manual. When calling DESA International, have ready model number of your heater the replacement part number NOTE: USE OF ANY OTHER GLASS DOOR ASSEMBLY NOT TESTED WITH THIS FIREPLACE MAY CONSTITUTE A FIRE HAZARD AND WILL VOID THE DESA INTERNATIONAL WARRANTY. STORM COLLAR VSC2-20-10DM (20 PACK) FLASHING COMES WITH WIRE SPACER ROOF PITCH V6F-10DM - 0 to 6/12 V12F-10DM - 6/12 to 12/12 RETURN ROUND TOP TERMINATION VRTL-10D ECONO-TOP TERMINATION VETL-10D 10" CHIMNEY PIPE ASSEMBLY (INCLUDES OUTER AND INNER PIPES) V12-10DM (12" LONG) V18-10DM (18" LONG) V24-10DM (24" LONG) V36-10DM (36" LONG) V48-10DM (48" LONG) STARTER SET V30E-10DM OUTSIDE AIR KIT VAK4 (900147) PIPE SUPPORT ASSEMBLY V12S-10DM FIRESTOP SPACERS VFS-10DM FOR STRAIGHT PIPE V30FS-10DM FOR ANGLED RUN GRATE 36PNGR VENT HOOD VENT PLASTER COLLAR CONNECTOR DUCT - 4" X 3' EMBER PROTECTORS (5) FRONT PANEL ASSEMBLY ADJUSTABLE HOOD BLACK - GA6050 POLISHED BRASS - GA6052 ANTIQUE BRASS - GA6053 CABINET DOOR SET (LEFT & RIGHT) VPN36 GLASS DOOR SETS VDGPN36 (Cabinet Doors (2 sets) and end panel (1) - Brushed Brass) VDPPN36 (Cabinet Doors (2 sets) and end panel (1) - Polished Brass) VDG36PNFPC (Pyroceramic Fixed Glass Doors - Brushed Brass) Includes one piece of glass only VDP36PNFPC (Pyroceramic Fixed Glass Doors - Polished Brass) Includes one piece of glass only VDG36PNFP (Tempered Fixed Glass Doors - Brushed Brass) Includes one piece of glass only VDP36PNFP (Tempered Fixed Glass Doors - Polished Brass) Includes one piece of glass only 14 55505