FIELD OF OPERATION. Multi cyclones Bag filter Flue gas fan Rotary locks Conveying systems Accessories for dust collection plants

Similar documents
Solid biofuel solutions

Boiler Technical Specifications (2013)

Virtus Manufacturing Plant in Shanghai China

ROTARY DRYER CONSTRUCTION

INTEC Engineering GmbH Energy systems

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

ADVANCED Series 15P1 17P2 19P2

Sootblowers. Learning Outcome. Learning Objectives. When you complete this module you will be able to: Discuss sootblowers.

MAGNUM MAX ASPHALT PLANTS

Image_engl_08:Image-engl-RZ :55 Uhr Seite 1. INTEC Engineering GmbH Energy systems

FAN ENGINEERING. Sealing of Fan Housings

2x58 MW Coal Fired Power Plant at Mauritius

Boiler Draft Equipment

DUST COLLECTION TRAINING. Revision 2013

Small size, big energy savings

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

Coarse Coal Centrifuges. VM1650 is the world s largest capacity Coarse Coal Centrifuge

E q KESHAR. Product Range : Asphalt Stationary Drum Mix Plant. Wet Mix Macadam Plant. Asphalt Mobile Drum Mix Plant.

LIMESTONE HANDLING AND LIME MILLING SYSTEM

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Biomass Energy Systems

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Block Macerators Series ABM-2-S

ENTROPIE boiler TT100-01

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

RECYCLING OF ADHESIVE TAPE WASTE WITH THE PLAST AGGLOMERATOR SYSTEM

Technical Data Manual. Vitoflex 300-RF Wood-fired Boiler Vitoflex 300-RF 150, 220, 300, 400 and 540. for use by engineers and heating contractors

Fibre Sifter. Essential for board quality

ProcessBarron is a leader in the design, fabrication, installation, maintenance, and repair of air, flue gas and bulk materials handling system

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

DRUM DRYERS FOR THE WOOD PELLET INDUSTRY

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

ELECTRO STATIC PRECIPITATOR [ESP]

INTEC Engineering GmbH Energy systems

ETA HACK VR kw The all-rounder for businesses, industry and communities

AZN ATEX INSTALLATION AND MAINTENANCE

Masterflamme Convection Wood Stoves Perfect combustion with unique design

ENTROPIE boiler TT300

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Joint Crediting Mechanism Project Design Document Form

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

ENERGY UTILIZATION IN CERAMIC TILES INDUSTRIES

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

ZERMA THE HOME OF SIZE REDUCTION ZBS AFFORDABLE SHREDDER FOR LUMPS & PURGINGS

Document Code: 1 (6) Issuing date: Status:

Granulators Reprocessing Plastic Scrap into Valuable Regrind. world of innovation

Veto Spring Agitator. User Manual Installation, Operation and Service

LAARMANN CM 2500 / CM Power Cutting Mill. Superior Cutting Mills engineered for rapid reduction of large particles. Innovators in Solids

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

Fireplace inserts Water heating fireplace inserts

Fireplace inserts Water heating fireplace inserts Fireplace door

LAARMANN CM Power Cutting Mill. Superior Cutting Mill engineered for rapid reduction of large particles. Innovators in Solids

Shredders Made in China

Refrigeration dryers DW 2-504

User Manual. Rev Please read and understand all instructions before use. Retain this manual for future reference.

TUNNEL FANS STANDARD AND HOT SMOKE

Rocket heater GAMERA

Hurricane Cyclones To Reduce Emissions of Dryer Cyclones in Glowood Pellet Plant April 2016

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

WOOD CHIP/PELLETS HEATING SYSTEMS

W / E / W / E / $10.00

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

EQUIPMENT Group 6 PACKAGE PRICE 2.350, Compressor KAESER SM bar. 203 Refrigeration dryer KAESER T135. Compressed air tank KAESER 90 l

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

Efficient CHP-plant 150 kw

International Process Plants

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Modern vacuum and overpressure generation for pneumatic conveying

ENVIRO INTERNATIONAL CORPORATION

STRAW-FIRED BOILERS AND HEATERS

Centrifuging Solutions

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

BALE BREAKER AND OPENERS

Centrifugal Fans, Non-Overloading, Backward Inclined

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

Installation Manual EF5000 AUS & NZ

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Crushing Plant--ZYS High-Efficient Cone Crusher

Importance of a Draught Regulator

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

FLUIDIZED BED BOILERS

OFFICINE MINUTE VILLORBA - TREVISO

AIEA Presentation. Wood pellets heating systems.

the heating technology ecofire Pellet burning stoves range hydro

Portable honeycomb matrix compact dryer, with loading, combines dehumidifying plastic resin and conveying into a single unit.

HydroPower Washing. Setting the Standard in thorough Cleaning of Plastics: The Friction and Tornado Washers

RotaCut Inline Grinders True protection of downstream pumps and equipment.

PESIT-Bangalore South Campus

Biomass Drum Dryer LMK 2000 Model

Transcription:

CATALOGUE No: 4

2 develops as well as manufactures equipment for dust collection, mainly flue gas cleaning. FIELD OF OPERATION Multi cyclones Bag filter Flue gas fan Rotary locks Conveying systems Accessories for dust collection plants

3 CONTENT Sidan Cyclones 4-6 Bag filter 7-12 Fans 13 Rotary locks 14-16 Screw conveyors 17-18 Cyclones 19 Expansion bellows 19 Inspection covers 20 Dust bins 21-22 Valves 23 Design critera for JM products 24 Flue gas dust 25 Design and dimensions 26

4 MULTI CYCLONE JM-250 Multi cyclone JM-250 is built of a number of small cyclones connected in parallel. The number of cyclones is adapted to the gas flow. The multi cyclone is especially designed to clean fly ashes from solid flue firing of bio fuels but is also suitable for other applications. The nominal gas flow is between 1200-90000m³/h Art.no 30056 Viewed from the outlet side Viewed from the inlet side

5 MULTI CYCLONE JM-250

6 MULTI CYCLONE JM-250 SIZE 1x2 2x2 2x3 3x3 3x4 4x4 4x5 5x5 5x6 6x6 6x7 7x7 7x8 8x8 8x9 A 358 708 708 1058 1058 1408 1408 1758 1758 2108 2108 2458 2458 2808 2808 B 708 708 1058 1058 1408 1408 1758 1758 2108 2108 2458 2458 2808 2808 3158 C 250 250 315 315 400 400 450 450 550 550 630 630 730 730 820 D 1390 1390 1465 1465 1500 1500 1670 1670 1780 1780 1870 1870 1930 1930 2000 E 2080 2090 2580 2580 2950 2950 3470 3470 3980 3980 4400 4400 4870 4870 5330 F 315 315 450 450 550 550 780 780 950 950 1100 1100 1260 1260 1420 G 440 450 800 800 1050 1050 1350 1350 1650 1650 1900 1900 2210 2210 2510 H 1640 1640 1780 1780 1900 1900 2120 2120 2330 2330 2500 2500 2660 2660 2820 I 125 125 130 130 150 150 140 140 180 180 200 200 200 200 200

7 BAG FILTER Bag filter JM-64 is manufactured in standardized modules with bag filters, cell partitions, compressed air cleaning equipment, cleaning device and service door. These top parts can be installed within filter housings, which can be built for the requested number of modules. Top parts are mainly made of 5mm steel. Some parts of the bag filter top part are made of stainless steel. The filter housings are made of wellbraced 3 mm plate. The location of the dust inlet is adapted to the caracteristics of the dust and the required ducting. Technical data: Number of filter bags/module 64 st Length of filter bag: 2000 mm Filter surface/module: 46 m²

8 BAG FILTER, two (2) modules Number of filter bags: 128 st Filter surface: 92 m²

9 BAG FILTER, Three (3) modules Number of filter bags: 192 st Filter surface: 138 m²

10 BAG FILTER, four (4) modules Number of filter bags: 256 st Filter surface: 184 m²

11 BAG FILTER, eight (8) modules Number of filter bags: 512 st Filter surface: 368 m²

12 BAG FILTER, side accessed Side access with 2 Modules Number of filter bags: 128 st Length of filter bag: 1500 mm Filter surface: 69 m² Side access with 3 Modules Number of filter bags: 192 st Length of filter bag: 1500 mm Filter surface: 104 m²

13 FLUE GAS FANS Complete in all sizes Manufactured in a robust design with low speed in order to withstand tough operating conditions and to minimize the sound level (db)

14 DUST VALVE ROTOLOK The dust valve Rotolok is a robust construction, machined to required tolerances. The sides of the rotor are rotating why only the wings are exposed to wear. The wings are provided with 5mm thick adjusting blades. The driving device is connected with chain drive. (Normal speed is 4 rpm). Adjustable shaft sealing is of teflon with external bearing. Art.no. 10002-11 size 200 without driving device 10002-12 size 200 with driving device 10002-15 size 250 without driving device 10002-16 size 250 with driving device Size A B C D E 200 200 300 330 200 260 250 250 370 380 230 280 300 300 440 465 280 370 ROTOLOK is available in size up to 900x900 mm.

15 DUST VALVE JM-20 Dust valve JM-20 is a robust construction, machined to required tolerances. The sides of the rotor are rotating why only the wings are exposed to wear. The wings are provided with 5mm thick adjusting blades. The driving device is directconnected with low speed (9 rpm)* Stuffing boxes of heat resistant VITON. * Also available for higher speed Art.no. 10000-1 JM-20 with driving device 0,25 kw 10000-2 JM-20 without driving device Capacity at 9 rpm 1,2 m³/h design capacity 1,1 m³/h operating capacity

16 DUST VALVE JM-25 G + JM-50 G Dust valve JM-25 G and JM-50G are Manufactured of 3 mm plate. The dust valve has six blades and is provided with 8 mm Neopren rubber blades. The rubber blades are bolted to the plate profiles of the rotor shaft. The rotor has bearing in both ends. The driving device is directconnected with low speed. (9 rpm)* Range of application is mainly within the wood, paper and fodder industry * Also available for higher rpm. Designation Motor power (kw) Speed (rpm) Capacity Design m³/h Capacity Operating m³/h JM-25 G JM-50 G 0,25 0,25 9 9 7,7 15,4 7,0 14,0 JM-25 G Art.no. 30179-25 (With rotor of stainless steel Art.no. 30255-25 RF) JM-50 G Art.no. 30179-50 (With rotor of stainless steel Art.no. 30255-50 RF) JM-25G JM-50G

17 SCREW CONVEYOR - 140 Art.no 30090 Cover Ø139,7 x 4,0mm Screw Ø120mm pl.j 35x6 Motor 0,25 kw, 9 rpm Also available as U-screw

18 SCREW CONVEYOR-260 Art.no 20039 Cover Ø262,0 x 4,0mm Screw Ø232 mm pl.j 70 x 15 Motor: Parallel Shaft Helical Gearmotor 0,55kW, 9,6r/m

19 CYCLONES Cyclones are available as follows: Primary cyclone Standard cyclone High efficiency cyclone As standard manufactured of 3 mm plate and 6 mm heavy plate in parts exposed to wear. EXPANSION BELLOW Expansion bellows With expander manufactured of stainless steel Art.no 30007 Available as : Round Rectangular Square

20 INSPECTION COVERS Inspection door, round With a diameter of : 530mm. Insulated door with quick acting lock and a frame of 150 mm Art.no 10006 Inspection door, square/ rectangular Insulated door with quick acting lock and a frame of 60,100 or 150 mm (size 40x40 is provided with twin lock). cm Art. No 60 mm frame Art. No 100 mm frame Art. No 150 mm frame 12x15 30023-51 30023-511 30023-512 15x25 30023-52 30023-521 30023-522 25x25 30023-53 30023-531 30023-532 25x40 30023-54 30023-541 30023-542 40x40 30023-55 30023-551 30023-552

21 DUST VALVE JM-15/45 DUST BIN JM-45 Dust valve, cover. JM-15/45 Art.no 10003 Dust bin JM-45 Art.no 20004 Volyme: ~ 84 liter

22 DUST VALVE JM-25/60 DUST BIN JM-60 Dust valve, cover. JM-25/60 Art.no 10026 Dust bin JM-60 Art.no 20014 Volume: ~125 liter

23 VALVES Single blade valve with simple bearing. With rest for better gastight. Simple bearing with bush. Manufactured as round and square. Maximum size 500 mm. Art.no 40078 Single blade valve with ball bearing units. With rest for better gastight. Bearing units and adjustable shaft sealing (bronze bushing). Manufactured as round and square. Art.no 20019

24 FLUE GAS CLEANING Design critera

25 FLUE GAS DUST Flue gas dust can be divided into two basically different types with regard to the way in which it is formed. Coarse particle fractions These consist of fuel particles, ash and soot agglomerates being released during decarbonizing work. The particle dimensions usually exceed 1/1000 mm and the dust can be separated in dynamic dust collectors. Coarse particles are a major pollutant with regard to weight or volume but they discolor the flue gas only slightly. Coarse particles cause problems by settling and polluting the area round the flue. Fine particle fractions Gaseous hydrocarbon which have escaped secondary combustion, condense when the flue gases are cooled down in the convection section of the boiler and become fine soot. The particle dimensions are extremely small, less than 1/1000 mm. Owing to the small mass of the particles they cannot be made to deviate sufficiently from the flow lines of the gas to enable separation in dynamic separators. The finest particle fractions can be a major pollutant, as regards the number of particles. They discolour the flue gases considerably. Therefore, a dark flue gas exhaust indicates that the combustion needs to be improved. Plants with pre-boiler Some solid fuels, especially bio fuels contains a lot of water and the combustion therefore often is made in a ceramical insulated pre-boiler allowing high combustion temperature. Conventionally designed pre-boilers that are heavy loaded, emit high contents of dust which is a consequence of high gas transformation. When redoubling the load per m2 rust surface the dust captivity may increase ten times or more. To achieve a complete combustion it is important that the pre boiler is equipped with well designed arrangements for supply of primary and secondary air. Experiences show that the air should be supplied by fans and that the fuel injection, the burning air and the flue gas flow must be coordinated. When the working conditions of the flue gas cleaning sysem are affected by the efficiency of the combustion plant it is vital that the view-points above are taken into consideration. High contents of unburned fuel particles results both in losses and unnecessary wear of the cleaning equipment. Unburned gaseous hydrycarbons also result in losses as well as they may condensate and cause pluggings.

26 DIMENSIONING SOLID FUEL FIRING 1 2 3 4 5 10 20 30 40 50 100 (x 1000 m³/h) Preliminary dimensioning for wood fuel firing 1. Find the boiler efficiency 2. Go diagonally upwards to the line for fuel humidity content 3. Go vertically to the line for gas flow in Nm³/s. 4. Go diagonally upwards to the relevant gas temperature 5. Go vertically upwards and read the actual gas flow OIL FIRED BOILER Preliminary dimensioning for oil fired boiler 1. Find the boiler efficiency 2. Go diagonally upwards to the relevant CO²-content. 3. Go vertically to the line for gas flow Nm³/s. 4. Go diagonally upwards to the relevant gas temperature 5. Go vertically upwards and read the actual gas flow The three broken-dashed lines show examples of preliminary estimations of actual gas flow Solid fual boiler 1: 1,3Mw Actual gas flow 4250m³/h Solid fuel boiler 2: 14Mw Actual gas flow 63000m³/h Oil fired boiler 1: 6,5 Mw Actual gas flow 16000m³/h