POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS

Similar documents
Model 4880 Status Output Display Module Manual

Heatrix Electric Duct Heater HXOB Installation Instructions

ADC150 Automatic Draft Control

SERVICE BY QUALIFIED PERSONNEL ONLY

ULTRA-SAFE Explosion-proof Duct Heaters

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

EEMAX ProAdvantage Series 1

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Ammonia Detection System Codes and Design Specifications

Figure 30: Sample Case 8

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

ULTRA-SAFE Explosion-proof Duct Heaters

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Power Supply Display Module PSDM. Installation and Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Troubleshooting Guide

FLAKER/DCM SEQUENCE OF OPERATION

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

CM R-410A High Efficiency Water Source Heat Pump

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

BGH Series Hot Surface Ignition Control

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

CommStat 4 Controller

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Troubleshooting Guide

ENERVEX ADC100 DRAFT CONTROL

CR Series Command Relays

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Instructions for the fan motor control system with integrated wiring terminals SILVER C

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

REV: 000. Radiant Flash Service Manual

Installation Guide for models:

DIGITAL METERS Large Display Temperature Meters Instruction Manual

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Installation Guide for models:

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

ESP TECHNOLOGIES LIMITED

CONTROL PANEL INSTRUCTIONS RSQ-4

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

ACL TC 200 TEMPERATURE CONTROLLER

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

CN7232 Advanced Garage Ventilation Controller

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

SPECIFICATIONS. Contents List

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Instruction Manual Model L2 RF Switch

THERMAL MANAGEMENT SOLUTIONS

ADDITIONAL INFORMATION

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIONAL TEMPERATURE SWITCH. Manual Number: FXTX2116-1

Operator: Save these instructions for future use!

SP-1000X. Panic Device Power Controller Installation Guide. Rev

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Powerohm Resistors Digital HRG System

ECO N DATE DESCRIPTION OF CHANGE CHG

MBCE-110/230UV Flame Sensor Module

50A Integrated Furnace Control

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

FEC400 Series. Installation Manual

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Honeywell ENERGY SAVINGS KIT

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

THERMAL MANAGEMENT SOLUTIONS

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Tri-Stack Smart System

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

MANUAL RESET ALARM RELEASE

PRYCO, INC. FUEL CONTROL

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

120 VAC SYSTEM CONTROL KIT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

YP7899C SERIES Burner Management Panel

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

INTRODUCTION / TABLE OF CONTENTS

Operator: Save these instructions for future use!

MANUAL RESET ALARM RELEASE BOX

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Transcription:

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS WARNING: Disconnect power to the installation locations before installing the fan and controller! WARNING: Wait three minutes after disconnecting the VFD before servicing! WARNING: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Incorrect assembly can cause electric shock or damage the motor and the controller. Supply power guidelines Before beginning fan installation, route power wiring to the VFD installation site. Refer to the minimum supply circuit requirements for your fan size below. foil X3.0 Fan Diameter Minimum Circuit Size 1 PFX3-08 8 ft (2.4 m) PFX3-10 10 ft (3.0 m) PFX3-12 12 ft (3.6 m) PFX3-14 14 ft (4.3 m) PFX3-16 16 ft (4.9 m) PFX3-18 18 ft (5.5 m) PFX3-20 20 ft (6.1 m) PFX3-24 24 ft (7.3 m) 20 A @ 200 240 V, 1 Φ 10 A @ 200 240 V, 3 Φ 10 A @ 400 480 V, 3 Φ 30 A @ 200 240 V, 1 Φ 20 A @ 200 240 V, 3 Φ 10 A @ 400 480 V, 3 Φ 30 A @ 200 240 V, 1 Φ 20 A @ 200 240 V, 3 Φ 10 A @ 400 480 V, 3 Φ 10 A @ 575 600 V, 3 Φ foil X3.0 Plus Fan Diameter 2 Minimum Circuit Size 1 PPX3-10 12 ft (3.6 m) PPX3-12 14 ft (4.3 m) PPX3-14 16 ft (4.9 m) 30 A @ 200 240 V, 1 Φ 20 A @ 200 240 V, 3 Φ PPX3-16 18 ft (5.5 m) 10 A @ 400 480 V, 3 Φ PPX3-18 20 ft (6.1 m) 10 A @ 575 600 V, 3 Φ PPX3-20 22 ft (6.7 m) PPX3-24 24 ft (7.3 m) 1. All VFDs produce three-phase output power regardless of input phase. 2. With foil Plus winglets wiring guidelines Dedicated Branch Circuit Protection. Each fan requires dedicated branch circuit protection. Conduit. VFD output/motor input leads cannot share a conduit with any other controller s supply feed. Local Disconnect. If required, a local disconnect should be installed per all national and local codes. Manual Disconnect. To satisfy some local code requirements, it may be necessary to install a manual disconnect at the fan motor location when the fan is not within line-of-sight of the controller.

: 200 240 V, 1 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD (200 240 V, 1 Φ) using single-phase input from power supply. Actual component layout may differ from illustration. / NEMA L6-20P (1.0 hp) or NEMA L6-30P (1.5 2.0 hp) /

: 200 240 V, 1 Φ with EMI filter Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a typical EMI filter installation on a standard VFD (200 240 V, 1 Φ) using single-phase input from power supply. Actual component layout may differ from illustration. / NEMA L6-20P (1.0 hp) or NEMA L6-30P (1.5 2.0 hp) / /

: 200 240 V, 3 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD (200 240 V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L15-20P /

: 200 240 V, 3 Φ with EMI filter Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a typical EMI filter installation on a standard VFD (200 240 V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L15-20P / /

: 400 480 V, 3 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD (400 480 V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L16-20P /

: 400 480 V, 3 Φ with EMI filter Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a typical EMI filter installation on a standard VFD (400 480 V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L16-20P / /

RUN STOP FWD REV : 575 600 V, 3 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD (575 600 V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / MODE RUN ENTER STOP RESET VFD-M 1.5KW WARNING: /

Fire relay wiring (E Series) ON From main FP or N box (if applicable) A contact closure across digital input terminals MI3 and DCM will result in fan shutdown. The relay uses a Normally Open (N.O.) contact. The relay coil must be energized by the FP for fan shutdown. Two additional relay coil leads are provided to facilitate supervision pass-through where required. An alarm condition will stop the fan and issue a fault at the controller. (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: 20 32 VDC @ 20 ma ON From main FP or N box (if applicable) Optionally, the relay can be used with a Normally Closed (N.C.) contact. The relay coil must remain energized by the FP for fan operation. This would be considered a fail safe or fail open wiring arrangement. F H U Two additional relay coil leads are provided to facilitate RUN STOP FWD REV REM LOC supervision pass-through where required. An alarm condition will stop the fan and issue a fault at the controller. (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: 20 32 VDC @ 20 ma

Fire relay wiring (M Series) From main FP or N box (if applicable) A contact closure across digital input terminals M3 and GND will result in fan shutdown. The relay uses a Normally Open (N.O.) contact. The relay coil must be energized by the FP for fan shutdown. RUN STOP FWD REV MODE RUN ENTER STOP RESET Two additional relay coil leads are provided to facilitate supervision pass-through where required. VFD-M 1.5KW An alarm condition will stop the fan and issue a fault at the controller. U T1 V T2 W T3 Brake B1 B2 (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: 20 32 VDC @ 20 ma From main FP or N box (if applicable) Optionally, the relay can be used with a Normally Closed F (N.C.) H contact. The relay coil must remain energized by the U FP for fan operation. This would be considered a fail safe RUN STOP FWD REV REM LOC or fail open wiring arrangement. RUN STOP FWD REV MODE RUN ENTER STOP RESET Two additional relay coil leads are provided to facilitate supervision pass-through where required. VFD-M 1.5KW An alarm condition will stop the fan and issue a fault at the controller. U T1 V T2 W T3 Brake B1 B2 (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: 20 32 VDC @ 20 ma