SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

Similar documents
SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Gas Discharge Tubes GTCX28-XXXM-R05 Series

PolySwitch TS600 Overcurrent Protection Devices

Gas Discharge Tubes. Features: Benefits: Applications:

Telecom Fuses. Benefits. Features. Applications


Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Specification Status: Released

Specification Status: Released

DATASHEET PolySwitch RKEF Devices

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

RUE Selection Guide and Product Data. RUE Selection Guide

Specification Status: Released

Specification Status: Released

Multi Layer Varistor Overvoltage Protection Device

PolySwitch Telecommunications and Networking Resettable Devices

and Product Data VTP Selection Guide

PolySwitch Telecommunications and Networking Resettable Devices

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

M7100 Pressure Transducer

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Technical Data Sheet 1.6mm Side Looking Phototransistor

1N4001 THRU 1N4007 1N4001 THRU 1N SILICON RECTIFIER. Features:

PolySwitch Surface-mount Resettable Devices

D5100 Industrial Differential Pressure Transducer

FEATURES ORDERING CODE EMCP C 100 N T (1) (2) (3) (4) (5) (6) (7) SMT Multilayer EMI Filter (Power Line) TRIGON COMPONENTS

EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

D5100 Industrial Differential Pressure Transducer

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

ULTRA FAST RECITIFIERS

CII FCAC-150 Series Relay

Technical Data Sheet 1.5mm Side Face Infrared LED

Technical Data Sheet 3mm Phototransistor T-1

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

INTERNATIONAL STANDARD

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Technical Data Sheet 5mm Phototransistor T-1

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

AO Annunciator Module

PCB Relays Single Relays

M5200 Industrial Pressure Transducer

Technical Data Sheet 5mm Infrared LED, T-1

SMD 2121 Black Frame MC-S2121BHA

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Inverted Through Board Surface

VAMP 120 & 121. Arc flash detection units. Product picture

Installation Instructions for the

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

M5800 Pressure Transducer with Rotatable Display

DP86 Constant Voltage with Fitting

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

Austin Series Non-Isolated SMT DC - DC Power Modules: 3.3 Vdc and 5.0 Vdc Input, 1.5 Vdc Vdc Output, 6A

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

Jun08 Rev C

Installation Instructions CS3 Three Phase Solid State Relay

U5300 Industrial Pressure Transducer

HM1500LF Relative Humidity Module

Chapter 7. Troubleshooting

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Introducing Hermaphroditic Blade and Receptacle Connector

DS1486/DS1486P RAMified Watchdog Timekeeper

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

U5700 Submersible Liquid Level Pressure Transducer

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

PolySwitch Surface-Mount Resettable Fuses

Features. Figure 1. Recommended Application

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

SENSOR SWITCH. OncQue Corporation 大日科技股份有限公司. Item No. RBS07 Series Description TILT SWITCH Version 13 Page 1 of 16 Date Nov. 04, 2013 FUNCTIONS

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

USB 3.0 Plug & Receptacle

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

PRODUCT SPECIFICATION

7800 SERIES EC7823/RM7823 Relay Module

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

Technical Data Sheet Opto Interrupter ITR

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

HM1520LF Relative Humidity Module

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

KILOVAC K1K High-Voltage Contactor

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

M5800 Pressure Transducer with Rotatable Display

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Transcription:

Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction. These devices have a high electrical surge capability to help protect against transient faults and a high off-state impedance, rendering them virtually transparent during normal system operation. SiBar thyristor surge protectors are designed to assist telecommunication and computer telephony equipment in meeting the applicable requirements and industry specifications. Benefits: Helps provide protection for sensitive telecom electronic equipment Low capacitance Low leakage current Low power dissipation Fast, reliable operation No wear-out mechanisms Helps designers meet worldwide telecom standards Helps reduce warranty and service costs Easy installation Helps improve power efficiency of equipment Features: RoHS compliant available on all parts Bidirectional crowbar transient voltage protection Broad voltage range 6V 400V Low capactiance 20pF-45pF @ 50V High off-state impedance Low on-state voltage High surge capability Short-circuit failure mode Surface-mount technology DO-214AA SMB package 10 x 1000 μs 100A surge rating Helps equipment comply with TIA-968, Telcordia GR-1089, IEC61000-4-5, ITU K.20/21/45 Applications: Central Office Equipment Analog and digital linecards (xdsl, T1/E1...) Phones, answering machines Set top boxes POS systems Fax Machines PBX systems 2007 Tyco Electronics Corporation. All rights Reserved. 1 Rev: B Date: December 12, 2007

Table SB1 - Electrical Characteristics Part Number V DM Max. V BO Max. I H Min. (ma) V T Max. C1 (Typ) @ 50V DC Bias (pf) C2 (Typ) @ 2V DC Bias (pf) TVB006RSC-L 6 25 50 (typ) 4 --- 75 5 TVB025RSC-L 25 40 150 4 --- 65 5 TVB035RSC-L 35 55 150 4 --- 55 5 TVB065RSC-L 65 88 150 4 45 90 5 TVB090RSC-L 90 125 150 4 40 80 5 TVB120RSC-L 120 160 150 4 35 75 5 TVB140RSC-L 140 180 150 4 30 65 5 TVB170RSC-L 170 220 150 4 30 60 5 TVB190RSC-L 190 260 150 4 30 60 5 TVB220RSC-L 220 295 150 4 30 60 5 TVB270RSC-L 275 350 150 4 30 60 5 TVB300RSC-L 320 400 150 4 25 50 5 TVB360RSC-L 360 460 150 4 25 50 5 TVB400RSC-L 400 540 150 4 20 45 5 Notes: All electrical characteristics are measured at 25 C. VDM measured per UL497B pulse requirements: at max. off-state leakage current (IDM) = 5 µa. VBO measured at 100V/µs. Off-State Current @VDM (μa) Table SB2 Surge Current Rating Part Number TIA-968 Telcordia GR-1089* IEC61000-4-5 ITU K.20/21/45* Type A 5 x 320 µs Type B pp (A) 10 x 560 µs 10 x 160 µs 10 x 1000 µs 2 x 10 µs 8 x 20 µs I PP (A) 5 x 310 μs (VOC: 10 x 700μs) I TSM Min. (A) di/dt dv/dt (A/µs) (V/µs) TVBxxxRSC-L 150 140 200 100 500 400 150 41 500 2000 Notes: *Lightning current wave forms for applicable industry specification. ITSM, peak on-state surge current is measured at 60 Hz, one cycle. di/dt: critical rate-of-rise of on-state current (pulsed power amplifier Vmax = 600V; C = 30µF). dv/dt: critical rate-of-rise of off-stage voltage (linear wave form, VD = rated VBO, Tj = 25 C) 2007 Tyco Electronics Corporation. All rights Reserved. 2 Rev: B Date: December 12, 2007

Table SB3 Dimensions in Millimeters A B C D Dimension Min. Max. Min. Max. Min. Max. Min. Max. 4.06 4.57 3.30 3.94 1.90 2.41 1.95 2.20 TVBxxxRSC-L (0.160) (0.180) (0.130) (0.155) (0.075) (0.095) (0.077) (0.086) H J K P S Dimension Min. Max. Min. Max. Min. Max. Ref Min Max. 0.051 0.200 0.150 0.31 0.76 1.27 0.51 5.21 5.59 TVBxxxRSC-L (0.002) (0.008) (0.006) (0.012) (0.030) (0.050) (0.202) (0.205) (0.220) Notes: *D dimension is measured within dimension P. TVB series devices use industry standard SMB package type. All devices are bidirectional and may be oriented in either direction for installation Table SB4 Physical Characteristics and Environmental Specifications Lead material Matte tin finish (-L devices) Encapsulating material Epoxy, meets UL94V-0 requirements Solderability per MIL-STD-750, Method 2026 Solder heat withstand per MIL-STD-750, Method 2031 Solvent resistance per MIL-STD-750, Method 1022 Mechanical shock per MIL-STD-750, Method 2016 Vibration per MIL-STD-750, Method 2056 Storage temperature ( C) -55 to 150 Operating temperature ( C) -40 to 125 Junction temperature ( C) 150 Maximum Lead Temperature for Soldering Purpose; for 10s ( C) 260 Table SB5 Reliability Tests Test Conditions Duration High temperature, reverse bias +100 C, 50VDC bias 1000 hours High humidity, high temperature, reverse bias 85% RH, +85 C, 50VDC bias 1000 hours High temperature storage life +150 C 1000 hours Temperature cycling -65 C to +150 C, 15 minute dwell 1000 cycles Autoclave 100% RH, +121 C, 15 PSI 96 hours 2007 Tyco Electronics Corporation. All rights Reserved. 3 Rev: B Date: December 12, 2007

2007 Tyco Electronics Corporation. All rights Reserved. 4 Rev: B Date: December 12, 2007

Table SB6 Packaging and Marking Information Recommended Pad Layout (millimeters/inchs) Part Tape and Reel Standard Part Dimension Dimension Dimension Agency Description Quantity Package Marking A (Nom.) B (Nom.) C (Nom.) Recognition* TVB006RSC-L 2,500 10,000 06RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB025RSC-L 2,500 10,000 25RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB035RSC-L 2,500 10,000 35RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB065RSC-L 2,500 10,000 65RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB090RSC-L 2,500 10,000 90RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB120RSC-L 2,500 10,000 12RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB140RSC-L 2,500 10,000 14RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB170RSC-L 2,500 10,000 17RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB190RSC-L 2,500 10,000 19RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB220RSC-L 2,500 10,000 22RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB270RSC-L 2,500 10,000 27RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB300RSC-L 2,500 10,000 30RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB360RSC-L 2,500 10,000 36RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB400RSC-L 2,500 10,000 40RC 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL *UL497B, File # E179610 308 Constitution Drive, MS R21/2A Tel (800) 227-7040 www.circuitproection.com Menlo Park, CA USA 94025-1164 (650) 361-6900 www.circuitprotection.com.hk (Chinese) Fax (650) 361-2508 www.circuitprotection.jp (Japanese) Raychem, PolySwitch, SiBar, TE Logo and Tyco Electronics are trademarks. All other trademarks and copyrights are property of their respective owners. 2007 Tyco Electronics Corporation. All rights Reserved. 5 Rev: B Date: December 12, 2007