AVPTC. Air Handler 1½ to 5 Tons

Similar documents
AVPTC Multi-Position, Internal Txv

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBR. Multi-Position. Modular Blower

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

TECHNICAL SPECIFICATIONS

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Bosch BVA Series Air Handler

HIGH EFFICIENCY AIR HANDLER

13 GEP A L P - 1 A

VERTICAL MOUNT AIR HANDLERS

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

TECHNICAL SPECIFICATIONS B6VMMX

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

FEM4X. Product Specifications FAN COILS /14/15

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

TECHNICAL SPECIFICATIONS

ComfortNet -Compatible

MBVC INTRODUCTION CHECKING PRODUCT RECEIVED BLOWER CABINET INSTALLATION INSTRUCTIONS NOTICE IF A 1 FLASH ERROR CODE OR AN EC HTR TOO LARGE ERROR IS

RGE 13 A T - 1 A

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

WAHL A Product Specifications

PRODUCT SPECIFICATIONS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

AVPTC**14** AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

AIR HANDLERS AIR HANDLERS

MERIT SERIES Up Flow / Horizontal

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Ruud Standard Efficiency Air Handler

Ruud High Efficiency Air Handler

TECHNICAL SPECIFICATIONS

Bosch BVA Series Air Handler

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

REM4P, REM4X. Product Specifications

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

residential PRODUCTS CATALOG

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Fan Coils & Air Handlers Product Catalog

TECHNICAL SPECIFICATIONS

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

CB X 32 mv

TECHNICAL SPECIFICATIONS

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Installation and Start-Up Instructions

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Ruud Standard Efficiency Air Handler

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Transcription:

Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in communicating mode Auto configuration of the airflow and tonnage in communicating mode In non-communicating mode, up to field-selectable airflow settings can be adjusted to optimize the system s CFM for each individual mode of operation R-0A refrigerant-compatible Factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor All-aluminum evaporator coil Provides constant CFM over a wide range of static pressure conditions independent of duct system Provides adjustable low CFM for efficient fan-only operation CFM indicator with front-panel sight glass Improved humidity control and comfort Compatible with variable-capacity heat pumps and cooling applications Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections AHRI Certified; ETL Listed Cabinet Features New rigid SmartFrame cabinet depth for easy attic access Galvanized, leather grain-embossed finish Foil-faced insulation covers the entire blower case to reduce operating sound and cabinet condensation Glue-less cabinet insulation retention Screw-less sides & back prevents condensation Multi-position capability: upflow, downflow, horizontal or vertical Coil-mounting track for quick repositioning Tool-less filter access (washable filters available) Easily convertible -way design Multiple electrical knockouts * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-A www.amana-hac.com 6/ Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes /

Nomenclature A V P T C 8 B AA 5 6,7 8 9 0, Brand Engineering* A Single- Piece Major/Minor Revisions Airhandler *Not used for inventory management Unit Applicaon Refrigerant Charge C Ceiling Mount PSC Motor = R- 0A R MulN PosiNon PSC Motor S MulN PosiNon EEM Motor Electrical W Wall Mount PSC/EEM Motor 08/0V, Phase, 60 Hz V MulN PosiNon Variable- Speed Motor- CommuminacaNng Cabinet Width B = 7½" Cabinet Finish C = " U Unpainted D = ½" P Painted Nominal Capacity @ SEER Expansion Device 8 = ½ Tons = ½ Tons F Flowrator = Tons 8 = Tons T Expansion Device 0 = ½ Tons 60 = 5 Tons Communicaons 6 = Tons C = ComfortNet TM CompaNble www.amana-hac.com SS-A

Specifications BA* 0CA* 6CA* DA* 8DA* 60DA* Nominal Ratings Cooling (BTU/h),000 0,000 6,000,000 8,000 60,000 CFM (High) 00/600 00/600 600/800 700/800 800/50 000/600 Blower Diameter 0⅝" 0⅝" 0⅝" 0⅝" 0⅝" ⅝" Width 6" 8" 0⅝" 0⅝" 0⅝" 0⅝" Coil Drain Connection FPT ¾" ¾" ¾" ¾" ¾" ¾" Service Valve Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ⅞" ⅞" ⅞" ⅞" ⅞" Electrical Data Voltage 08/0 08/0 08/0 08/0 08/0 08/0 Electric Heat Capacity (kw), 5, 6, 8, 0, 5, 5, 6, 8, 0, 5, 5, 6, 8, 0, 5, 9 5, 6, 8, 0, 5, 0 5, 6, 8, 0, 5, 0 5, 6, 8, 0, 5, 0, 5 Min Circuit Ampacity.9/.9.9/.9 6.5/6.5 6.5/6.5 6.5/6.5 8.6/8.6 Max. Overcurrent Device (amps) 5/5 5/5 5/5 5/5 5/5 5/5 Minimum VAC 97 97 97 97 97 97 Maximum VAC 5 5 5 5 5 5 Blower Motor A.9.9 5. 5. 5. 6.9 HP ½ ½ ¾ ¾ ¾ Ship Weight (lbs) 00 8 8 67 67 67 SS-A www.amana-hac.com

Dimensions.6" (. cm).5" (.68 cm).08" (7.8 cm) ".50" (. cm).9" (7.9 cm).9" (7. cm) 7.5" (9. cm) 5." (. cm) 9." DRAIN PORT DETAIL.55" (.0 cm) C B.55" (.0 cm)." (7.9 cm)." (.6 cm)." (8.70 cm).55" (.0 cm) PLASTIC BREAKER COVER.8" (.6 cm) LOGO LOCATION.7" (5.5cm) SUCTION TUBE LIQUID LINE A G INLET TUBE SEE DRAIN PORT DETAIL H E D.7" (.9 cm) F INLET (FRONT VIEW).7" (.9 cm) " (.5 cm) 9.5" (9.5 cm) INLET (RIGHT SIDE VIEW).55" (.0 cm) Model A B C D E F G H B 5 6⅜ 7½ 8 5 ³ ₁₆ 8¹³ ₁₆ ¹⁵ ₁₆ 0C 9 9¹⁵ ₁₆ 0 7 7¹¹ ₁₆ 0½ ⅜ 6C 9 9¹⁵ ₁₆ 0 7 7¹¹ ₁₆ 0½ ⅜ D 58 ⁵ ₁₆ ½ 8³ ₁₆ 5³ ₁₆ ³ ₁₆ ⁵ ₁₆ ⅜ 8D 58 ⁵ ₁₆ ½ 8³ ₁₆ 5³ ₁₆ ³ ₁₆ ⁵ ₁₆ ⅜ 60D 58 ⁵ ₁₆ ½ 8³ ₁₆ 5³ ₁₆ ³ ₁₆ ⁵ ₁₆ ⅜ www.amana-hac.com SS-A

Airflow Data Cooling / Heat Pump Airflow B 0. 0. 0. 0. 0.5 0.6 0.7 0.8 0.9 A Low 5 0 0 0 5 0 0 5 5 B Low 580 575 575 570 565 560 555 555 550 C Low 70 705 695 690 675 655 650 60 65 D Low 85 805 795 785 765 75 75 75 70 A High 60 65 65 60 60 605 600 595 590 B High 895 885 875 865 85 85 85 800 790 C High 00 00 005 995 970 95 95 90 90 D High 85 75 60 5 0 090 080 065 050 0C 0. 0. 0. 0. 0.5 0.6 0.7 0.8 0.9 A Low 55 505 95 90 70 55 5 5 5 B Low 675 670 665 660 655 65 60 60 65 C Low 780 775 770 765 755 75 70 75 70 D Low 95 90 905 900 895 885 880 875 870 A High 680 675 675 670 665 660 660 655 655 B High 870 865 860 855 85 85 80 85 80 C High 00 00 05 00 00 05 00 005 000 D High 55 5 0 5 0 0 00 95 90 6C 0. 0. 0. 0. 0.5 0.6 0.7 0.8 0.9 A Low 565 555 55 50 50 85 75 65 55 B Low 70 70 700 690 675 655 65 60 60 C Low 95 95 90 90 885 860 850 80 85 D Low 0 0 00 090 070 050 00 00 00 A High 75 75 75 705 685 665 655 65 65 B High 00 005 995 985 960 90 90 95 905 C High 5 5 05 00 80 60 50 0 0 D High 590 580 570 560 50 50 50 500 90 D 0. 0. 0. 0. 0.5 0.6 0.7 0.8 0.9 A Low 675 660 65 65 605 580 565 550 50 B Low 80 80 795 785 765 70 70 70 70 C Low 05 05 05 05 990 970 955 95 95 D Low 75 65 60 50 5 0 0 00 95 A High 85 85 85 85 790 770 760 750 75 B High 5 0 0 0 090 075 065 055 05 C High 75 70 60 50 5 0 5 05 95 D High 85 85 80 80 795 780 770 765 755 Note: When applying a humidistat (normally closed), refer to the installation and operating instructions. The humidistat can adjust the cooling airflow to 85%. SS-A www.amana-hac.com 5

Airflow Data (cont.) Cooling / Heat Pump Airflow (cont.) 8D 0. 0. 0. 0. 0.5 0.6 0.7 0.8 0.9 A Low 95 90 95 90 905 890 885 880 875 B Low 075 065 060 055 00 00 00 05 00 C Low 75 70 60 55 0 5 0 5 05 D Low 5 5 0 5 00 90 85 75 70 A High 70 65 60 50 0 5 5 0 05 B High 565 560 560 555 55 55 50 50 55 C High 70 75 70 705 690 680 675 670 665 D High 85 80 805 800 785 775 770 760 755 60D 0. 0. 0. 0. 0.5 0.6 0.7 0.8 0.9 A Low 00 95 90 90 80 75 70 70 65 B Low 65 65 60 60 50 5 5 0 5 C Low 5 0 0 5 0 05 05 00 95 D Low 55 55 50 505 500 95 90 85 85 A High 600 595 595 590 585 580 580 580 575 B High 85 80 80 85 80 805 800 800 795 C High 95 90 90 905 900 890 885 885 880 D High 05 00 05 00 00 000 995 990 985 Note: When applying a humidistat (normally closed), refer to the installation and operating instructions. The humidistat can adjust the cooling airflow to 85%. Electric Heat Airflow HTR kw 9 0 BA* 0CA* 6CA* DA* 8DA* 60DA* ON ON ON 70 70 NR NR NR NR 5 ON ON OFF 780 780 00 600 600 60 6 ON OFF ON 850 850 60 60 60 670 8 ON OFF OFF 950 950 0 60 60 70 0 OFF ON ON 05 05 80 670 670 750 5 OFF ON OFF NR NR 0 70 70 780 9* NR NR 500 800 NR NR OFF OFF ON 0 NR NR NR NR 85 850 or 5* OFF OFF OFF NR NR NR NR 850 850 Note: Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation * Within thermostat user menu, CTK0* communicating thermostat will display 0kW for OFF- OFF- ON dipswitch selection, kw for OFF-OFF-OFF dipswitch selection. NR - Not Rated 6 www.amana-hac.com SS-A

Wiring Diagram HTR TL PLM PU M R 5 M WH 6 7 8 9 L L ONE () ELEMENT ROWS HTR TL HTR TL PLM PU M M R M M 5 WH 6 7 8 9 L L TWO () ELEMENT ROWS HTR TL HTR TL PLM HTR TL YL YL PU M M M M M M R R BR 5 WH 6 7 YL 8 9 L L L L THREE () ELEMENT ROWS HTR TL HTR TL HTR TL YL PLM HTR TL PU M M M5 M7 YL M M M6 M8 R R BR 5 WH 6 7 YL 8 9 FOUR () ELEMENT ROWS L L L L COLOR CODES: PK ---- PINK BR ---- BROWN WH ---- WHITE ---- UE GY ---- GRAY ---- RED YL ---- YELLOW OR ---- ORANGE PU ---- PURPLE GN ---- GREEN ---- ACK NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. PL PL 6 6 5 5 7 7 8 8 9 9 SEE NOTE 7 MARK ACCOING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 0 VAC 08 VAC COM WH BR 0 VA TRANSFORMER, SEE NOTE CIRCUIT MOTOR CONNECTOR GY ECM MOTOR HARNESS CIRCUIT HEATER CONNECTOR SEE NOTE 5 FAULT RECALL SEE NOTE 6 STATUS LED LEARN SEE NOTE 6 COM V A FUSE CONT FAN CAS SEE NOTE 8 7 SEGMENT DIAGNOSTIC DEHUM DISPLAY DIP SWITCHES TWO-STAGE INTEGRATED CONTROL MODULE CFM LED AF SELECT TRIM % COOL AF PROFILE DEHUM ENAE TRIM ENAE VAC TH SEE NOTE 6 RX LED HTR KIT(KW) S S S S S5 S6 S7 S8 S9 S0 S S S GN O Y Y W W G C CIRCULATOR OWER GN 5 R TR V THERMOSTAT CONNECTIONS V THERMOSTAT CONNECTIONS R W W Y Y G O DISCONNECT DEHUM C L FUSE A TO MICRO L TH W () W () CAS () CAS () +VDC () RX () TX () () TR COM INDOOR AIR CIRCULATOR WR 08/0 VAC 0 VA TRANSFORMER VAC HEAT SEQUENCER R INTEGRATED CONTROL MODULE L HEAT SEQUENCER R CONDENSATE SWITCH L INDOOR AIR CIRCULATOR WR LOW VOLTAGE (V) LOW VOLTAGE FIELD HI VOLTAGE (0V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL EQUIPMENT FIELD FIELD SPLICE RESISTOR OVERCURRENT PROT. DEVICE PLUG CONNECTION NOTES:. PLACE RED WIRES ON TRANSFORMER TERMINAL FOR 08 VAC OPERATION.. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 05 C. USE COPPER CONDUCTORS ONLY.. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 6. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK. 7. DISCA CONNECTOR PL WHEN INSTALLING OPTIONAL HEAT KIT. 8. THE CONDENSATE ALARM SWITCH (CAS) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING MODE SETUPS AND MUST BE ENAED WITH A COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT OPERATIONAL WITH LEGACY SYSTEMS. 00A0007-A Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-A www.amana-hac.com 7

Accessories Heat Kit Selection Model 0XC 05XC 06XC 08XC 0XC 05XC 08XC B X X X X X X X X 0C X X X X X X X X 0XC 6C X X X X X X X X D X X X X X X X X 8D X X X X X X X X 60D X X X X X X X X 5XA Model 5XB 5XF 9CA 9CB 0DA 0DB 0XF B 0C 6C X X X X X D X X X X X 8D X X X X X 60D X X X X X X C Circuit breaker option 5DC Downflow Kits DFK-B DFK-C DFK-D B** 0C** D** 6C** 8D** 60D** Single Point Kit ** Model HKR-5C HKR-0C HKR-C SPW-0 X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any air handler as long as a compatible heat kit is installed in the unit. Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. 0 Goodman Company, L.P. Houston, Texas Printed in the USA. 8 www.amana-hac.com SS-A