Moisture and Hydrocarbon Dew Point Measurement

Similar documents
Moisture and Hydrocarbon Dew-Point Measurement

Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II Hydrocarbon Dew-Point Analyzer

Promet I.S. Promet I.S. Process Moisture Analyser

Dew-Point Transmitters and Instruments

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Condumax II. Condumax II. Hydrocarbon Dew-Point Analyser. Automatic, on-line measurement of hydrocarbon and water dew point in natural gas

Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II Hydrocarbon Dew-Point Analyzer

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Using the Model 1500 Portable Chilled Mirror Hygrometer

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Datalogging as standard

Model D12-IR. Digital Gas Transmitter...

Products and performance

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Sieger Apex. Flexibility that meets your requirements

continuous emissions monitoring Combustion & Environmental Monitoring

Dependable Solutions for Gas Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

intrinsically safe detector for hydrocarbon gases

Unrivalled Detection.

Dräger X-am 7000 Multi-Gas Detection

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Zareba Sensepoint Pro

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Dräger PIR 3000 Detection of flammable gases and vapours

CRYOGENIC TEMPERATURE SENSOR SOLUTIONS FOR LIQUEFIED NATURAL GAS (LNG) TANK STORAGE

MICROpeL 75 Combustible Gas Sensor Part Number: PM

U L T R A S O N I C G A S L E A K D E T E C T O R

Using the DewTrak II Dew Point/ Humidity Transmitter

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Dräger PIR 7200 Toxic Gas Detection Transmitter

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SIMRAD GD10PE IR GAS DETECTOR

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Dräger Polytron 7000 Fixed gas detector

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Industrial Grade Gas Detection

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Dräger Flame 2350 (UV&IR) Flame Detection

Industrial Grade Gas Detection Detecting The Difference

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Industrial Grade Gas Detection

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Dräger Flame 2700 (Multi-IR) Flame Detection

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

Dräger REGARD -1 Control System

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

NO NO 2 NO x SO 2 CO CO 2 O 2

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Searchpoint Optima Plus

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

GAS PLUS ALARM SYSTEM

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

SIMRAD GD10 IR GAS DETECTOR

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

IT S WHAT S INSIDE THAT COUNTS

OLC(T) 100 FIXED GAS DETECTOR

ALTAIR 2X Gas Detectors It s what s inside that really counts

IT S WHAT S INSIDE THAT COUNTS

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

altair 2X Gas Detectors

Hazardous Area Zirconia Oxygen Systems

GS01 (wireless) Detection of flammable gases and vapours

Dräger X-zone 5500 Area Monitoring

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Flame Detection Jon Sarfas

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 (UV) Flame Detection

S5000 Gas Monitor. GMS5000.com

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Dräger REGARD -1 Control System

Heatless Desiccant Compressed Air Dryers

IT S WHAT S INSIDE THAT

Transcription:

Process Analyzers Moisture and Hydrocarbon Dew Point Measurement www.michell.com

Process Analyzers Moisture and Hydrocarbon Dew-Point Michell Instruments offers a comprehensive range of process analyzers for measuring water dew point, trace moisture and hydrocarbon dew point for the petro-chemical and natural gas industries. The range includes intrinsically safe and flameproof/explosion proof systems which are supplied as complete packages consisting of an analyzer or combination of analyzers and a fully integrated sampling system and control unit. A wide choice of standard process sampling systems is available, as well as the option of customized systems designed by our dedicated Systems Engineering department to suit especially demanding or complex applications. Michell s Condumax II is the hydrocarbon and water dewpoint analyzer of choice for the majority of gas transmission companies across the whole European gas distribution network. On-Line Process Analyzers: Universal Features In the petrochemical industry the measurement of moisture content in a multitude of process gases and liquids is one of the most difficult and demanding tasks for the process engineer. To maintain certain moisture content or avoid defined moisture levels is crucial for most chemical processes. Michell s state-of-the-art, on-line analyzers help increase plant efficiency and safety in many petrochemical sites across the globe. Comprehensive analyzer packages with selection of standardized sampling systems or customized solutions to suit exact application and installation requirements Choice of certified explosion-proof (EExd) or intrinsically safe (I.S.) measurement systems CSA (US) approved for Class 1, Division 1 ATEX approved for Zone 1 and 2 installation Unique Michell Calibration Exchange Service provides cost effective field maintenance of moisture measurement certified traceable to NIST Systems compatible with aggressive samples such as sour natural gas Engineering and applications specialists available through global network of Michell offices and factory trained representatives Professional commissioning services and site maintenance personnel training available worldwide. Background to Michell Instruments Michell Instruments is the international leader in the field of moisture and humidity measurement solutions. With over 30 years experience, Michell designs and manufactures a wide range of transmitters, instruments and system solutions capable of measuring trace moisture, humidity, dew point and oxygen in a vast range of applications and industries ranging from compressed air, power generation, process, oil and gas, pharmaceutical and many more. With a fast-growing international subsidiary and distribution network, the Michell Group provides solutions in dew point, moisture and humidity to the most demanding applications worldwide. Michell uses four key dew point measurement technologies in its products: Impedance method using a ceramic tile which delivers unrivalled speed of response and robustness. Chilled mirror method which has been incorporated into advanced, precision instruments for industrial and laboratory use. Dark spot technology, which was developed in partnership with Shell, to offer a world-class solution for the measurement of hydrocarbon dew point. Quartz crystal technology for a high precision, fast responding moisture measurement with self-calibration. Applications Natural Gas Applications Gas quality measurements to ensure compliance to transmission pipeline tariff specifications Avoiding hydrate formation and corrosion by monitoring the glycol dehydration plant output Gas heater Superheat control of fuel gas to protect turbine power plants and save energy Protect turbo expanders and pipeline compressors from liquid impact damage Petrochemical Applications Monitoring recycle gases during catalytic processes to maximize catalyst life and productivity HDPE and LDPE process gases and liquids ethylene, hexane, butane and many more LNG/LPG production and quality control Liquid benzene for styrene manufacture Fuels refining and custody transfer to avoid liquid water phase separation 2010 Michell Instruments

Moisture Sensing Technology for Process Gases and Liquids Michell s Advanced Ceramic Sensor technology provides rugged and reliable measurement of the water dew point and moisture content in both gases and liquids throughout natural gas and petrochemical industries. Our sensors are resilient to chemical attack and will not fail even when subjected to the most severe pressure shock. The Ceramic Sensor works by adsorbing water vapour in equilibrium with the fluid being measured into its porous active layer, sandwiched between two conductive plates. High sensitivity even at ultra low trace moisture levels is achieved by use of semiconductor techniques to achieve an extremely thin active layer, protected by a micro-porous metallic surface coating. Therefore the sensor responds rapidly to changes in applied moisture, both when being dried (on process start-up) and when called into action if there is moisture ingress into a process. All Michell Ceramic Moisture Sensors provide up to 1 C accuracy and excellent long-term stability in process applications. The unique Michell Calibration Exchange Service enables all our customers worldwide to maintain traceable certified calibration of our process moisture analyzers at modest cost with minimal spares stock and down time. conical shaped depression. A collimated beam of visible red light is focussed onto the central region of the optical surface to form an annulus ring of light. Optical detection is made of light dispersed. As the sensor is cooled during measurement cycle, hydrocarbon condensates form on the optical surface and its optical properties are modified the reflected light intensity of the annulus ring increases and there is a dramatic reduction in the scattered light intensity within the dark spot region. This highly sensitive secondary effect is used to determine the hydrocarbon dew point. Multi-Channel Solutions MCU Multi-Channel Process Moisture Analyzer Liquidew I.S. and Promet I.S. are offered in the multichannel MCU for up to four channels of liquid or gas phase measurement. Addition of further MCU units extends the capability to 8, 12 or more measurement channels, offering ultimate flexibility and cost efficiency. Michell s Ceramic Sensor Hydrocarbon Dew Point for Natural Gas Michell s hydrocarbon dew point technology uses the patented Dark Spot optical principle, a technique radically different from that of any other chilled mirror system. Sensitivity of the order of 5 mgm -3 of condensate enables the analyzer to detect the almost invisible films of condensate which are characteristic of hydrocarbon gases at dew point, due to their low surface tension and colourless appearance. Remote Interface For users of our EExd analyzers wishing to have a dedicated host system within a convenient safe area location, the optional RI provides advanced graphical display, status information, comprehensive logging functions and all programme configuration functions for up to 31 analyzers. Global access to full functionality is available through any web browser. The optical surface is the key element of the sensor cell and comprises an acid etched, semi-matt surface with a central Dark Spot Principle 2010 Michell Instruments

Hydrocarbon Dew Point in Natural Gas Process Analyzers The accurate and reliable measurement of the moisture content and hydrocarbon dew point in natural gas is critical for gas quality measurements in pipelines and gas turbine applications. Condumax II Continuous on-line measurement of the hydrocarbon dew-point temperature of natural gas, with optional water dew point. Hydrocarbon Dew Point Range Water Dew Point Range Operating Temperature Up to Δ 55 C measurement depression from Main Unit operating temperature Calibrated from -100 to +20 C dp ±0.5 C hydrocarbon dew point (single and multiple condensible component analysis) ±1 C from -59 to +20 C water dew point; ±2 C from -100 to -60 C water dew point Indoors/Outdoors -20 to +50 C. Max 95 % rh Max 100 barg Moisture in Process Gases Promet I.S A complete, turnkey hygrometer system for moisture measurement in critical process gas applications. Promet EExd Wholly hazardous area installed analyzer system for critical process gas applications. Operating Temperature Operating Temperature ATEX: II 2 G EExd IIB + H2 T4 Tamb =60 C CSA: certified to Class 1, Div 1, Groups B, C & D, T4 Two 4-20 ma outputs. RS485 Modbus RTU Process and analyser status via software register and display annotation. Integrated low flow alarms for each sample flow. Analyser status fault flag 23mA on ma output 1. -100 to +20 C dp Dew point: ±1 C between -60 & +20 C dp Dew point: ±2 C between 60.1 & -100 C dp Sensor outdoor: -40 to +60 C Control unit: 0 to +50 C Max 400 barg ATEX certified by EECS for use in hazardous areas to Ex II 1G EEx ia IIC T4. CSA certified IS Class I, Division 1, Groups A, B, C & D, T4 IECEx: Ex ia IIC T4 FM: IS/I/1/ABCD/T4 Two 4-20mA per channel. RS485 Modbus RTU. 4 alarm relays per channel -120 to +30ºC dp. Dew point: ±1 C between 59.9 & +20 C dp Dew point: ±2 C between 60 & -100 C dp Indoor/Outdoor -20 to +60 C Max 95 % rh. Max. 206 Barg ATEX : II 2 G Code: EEx d IIB + H2 T4 (135 C) ccsaus approved: Div 1, Class 1, Group B,C,D Two 4-20 ma per channel. RS485 Modbus RTU Two alarm relays per channel; optional flow alarm. www.michell.com

Process Analyzers Moisture in Process Liquids Liquidew I.S. Precise real-time measurement and control of process moisture conditions without the need for collection and analysis of liquid samples in a laboratory. Liquidew EExd The Moisture in Liquid Analyzer that offers the complete moisture measurement package for critical petrochemical liquid applications. Operating Temperature Operating Temperature -100 to +20 C dp (0.01 ppm W to saturation) Dew point: ±1 C between 60 & +20 C dp Dew point: ±2 C between 60.1 & -100 C dp Sensor: outdoor -20 to +60 C Control Unit: indoor 0 to +50 C Max 300 barg ATEX certified by EECS for use in hazardous areas to Ex II 1G EEx ia IIC T4. CSA certified IS Class I, Division 1, Groups A, B, C & D, T4 IECEx: Ex ia IIC T4 FM: IS/I/1/ABCD/T4 Two 4-20 ma per channel. RS485 Modbus RTU Four alarm relays per channel. -120 to +30 C dp (0.001 ppm W to saturation) Dew point: ±1 C between 59.9 & +20 C dp Dew point: ±2 C between 60 & -100 C dp Indoor/outdoor max -20 to +60 C, max 95% rh Max. 50 barg ATEX : II 2 G Code: EEx d IIB + H2 T4 (135 C) ccsaus approved: Div 1, Class 1, Group B,C,D Two 4-20 ma per channel. RS485 Modbus RTU Two alarm relays per channel Michell s Liquidew I.S sensors and sample conditioning system, housed in a temperature-controlled enclosure. Tamoil refinery, Switzerland. www.michell.com

Michell Instruments operates in the following markets: Compressed Air Dryers Pharmaceutical Standards Laboratories and Metrology Semiconductors Natural Gas and Petrochemicals Industrial and Pure Gas Production Power Generation Other Product Ranges Dew-Point Transmitters Michell offers the widest range of dew-point sensors and transmitters on the market. From the industry standard Easidew 2-wire transmitter to the new, rugged Easidew PRO IS for hazardous areas, all are supplied with sensors traceable to national standards. Portable Instruments Michell s range of easy-to-operate portable instruments provides fast, accurate and stable measurement of dew point, relative humidity and moisture concentration. They are designed to satisfy the most demanding industrial conditions, and are unique in the market for giving repeatedly fast response to low dew points. Chilled Mirror Instruments Chilled Mirror is a fundamental measuring technology offering the user exceptionally accurate, reliable and repeatable measurements from trace moisture to high humidity. Michell offers a range of instruments based on a rugged sensor design that is equally suitable for installation in demanding process environments or for use as an accurate reference instrument in a National Standards Laboratory. Calibration Instruments Michell has a wide offering of calibration equipment for the verification of trace moisture, dew-point and relative humidity sensors. A modular concept means that Michell s engineers can build for you a customised calibration solution that meets your exact needs. Components may include air compressor and dryer; low range or high range humidity generator; simple sensor housing or environmentally controlled test chamber and finally, verification using a traceable Michell Chilled Mirror Hygrometer. Oxygen Analyzers Michell brings you the very latest technologies in oxygen measurement, designed to give years of reliable and accurate service in laboratory, process and flue gas applications. From instruments featuring a unique sealed reference zirconia sensor to a transmitter with the latest generation thermo-paramagnetic oxygen and thermal conductivity technology, all Michell oxygen analyzers are available in a range of different configurations. Relative Humidity Instruments Michell s own RH sensing technology provides excellent resolution, long term stability and speed of response. We offer a wide range of humidity and temperature measuring sensors and instruments, including relative humidity transmitters, humidity and temperature transmitters as well as handheld indicators. The humidity generator range includes the most stable humidity generator on the market. Michell Instruments 48 Lancaster Way Business Park, Ely, Cambridgeshire, CB6 3NW Tel: +44 1353 658000, Fax: +44 1353 658199, Email: info@michell.com, Web: www.michell.com Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice. Issue no: Process Analyzers_97142_V3.1_UK_0310 2010 Michell Instruments