MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Similar documents
Moisture and Hydrocarbon Dew Point Measurement

Moisture and Hydrocarbon Dew-Point Measurement

Dew-Point Transmitters and Instruments

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Promet I.S. Promet I.S. Process Moisture Analyser

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Series 9000 Total Hydrocarbon Analyzer

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

PCMini52 Digital RH & Temperature Mini Probe User s Manual

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Condumax II Hydrocarbon Dew-Point Analyzer

Dräger PIR 7200 Toxic Gas Detection Transmitter

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

gas monitoring system

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Document Number March 23, 2016 Yokogawa Electric Corporation. Data Acquisition/Recorder. Data Acquisition and Monitoring. Paperless Recorder

Meteorology 432. Hygrometry Spring 2013

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Certificate: _01 / 2 February 2015

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Using the DewTrak II Dew Point/ Humidity Transmitter

A New Standard of Excellence

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Condumax II Hydrocarbon Dew-Point Analyzer

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Restek s Electronic Leak Detector

Cryogenic cooling with CUMULUS LF.

Condumax II. Condumax II. Hydrocarbon Dew-Point Analyser. Automatic, on-line measurement of hydrocarbon and water dew point in natural gas

Humidity Measurement Technology

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Benefits & Technology for Decentralizing a -40 F Dew Point

Dräger QuadGard Control System

SIL 2. Ultima X Series Gas Monitors CERTIFIED

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Improving Productivity, Quality and Security

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Hygrometry. The art or science of humidity observation

Adsorption Compressed Air Dryer Heatless or heater regeneration

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

DP 300 mobile dew point instrument

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Dräger Bump Test Station Calibration and Bump Testing

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Optidew & Optidew Vision High Performance Optical Dew-Point Transmitter User s Manual

Humidity sensor. Electronic Materials II (2004) Principle of ceramic humidity sensor

Condumax II Hydrocarbon Dew-Point Analyzer

Complete Gas Analysis

Sieger Apex. Flexibility that meets your requirements

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Datalogging as standard

HPLC Column Ovens and Temperature Controllers

3 3SP_O3_5 C Package

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.

GE General Eastern Instruments

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.

3SP_H2S_50 Package

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

SEC Signature Process Gas Analyzer

P R O D U C T D ATA S H E E T

Contamination Control for Electronic and Semiconductor Applications

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Dräger Configuration and Evaluation Software

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

Advanced Radiation Measurement Solutions

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

HM1520LF Relative Humidity Module

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

NEW Restek Electronic Leak Detector


JUPITER SERIES. High Throughput Closed Microwave Digestion/Extraction Workstation

Laser Gas Detection OEM Gas Sensing Solutions

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

SIMRAD GD10PE IR GAS DETECTOR

Dräger PIR 7000 Flammable Gas Detection

Dräger PIR 3000 Detection of flammable gases and vapours

PREMIER PLATINUM INFRARED GAS SENSOR

Transcription:

MICHELL GROUP Advanced Industrial Hygrometry and Process Instrumentation Company Profile, 2011

Who is the Michell Group? Leading in the world of solutions for humidity and gas analysers More than 30 years of experience in humidity measurement equipment Multiple product range Fast growing organization Global sales and service network

Ely

Corporate Structure Parametrics Investments (Michell Group) Manufacturing Sites Michell Instruments Ltd Ely UK Michell Instruments BV Oosterhout NL Michell Instruments SARL Lyon FR Sales/Service Michell UK Ely Michell DE Friedrichsdorf Michell FR Paris Michell NL Made Michell IT Milan Michell US Rowley, MA Michell JP Tokyo Michell CN Shanghai Michell Asia Perth

Extensive Sales and Service Network 3 manufacturing sites 9 Subsidiaries 50+ Distributors 140 Employees

Michell Group History 1974 Michell Instruments established 1980 Awarded contract to build EC Humidity Transfer Standard 1984 S4000 becomes part of the British National Humidity Standard 1986 Humidity calibration laboratory becomes first in UKAS accredited the world to be 1989 BS5750 part 2 awarded (ISO9002)

Michell Group History 1990 Sales and Service Centre opened in Germany 1994 World first 2-wire dew-point transmitter launched 1997 S4000TRS launched, giving -100 C dew point capability 2000 Subsidiary opened in Holland 2003 Subsidiary opened in France 2004 Subsidiary opened in China 2005 Subsidiaries opened in Italy and Japan 2006 Acquisition of Rense Instruments BV in Made, NL 2007 Subsidiary opened in USA 2008 First Far East Agent Training

Technologies

Moisture technologies and their ranges No single technology can cover the entire range All have limitations Impedance TDL Quartz Sensors Chilled Mirror Hygrometer Dew-Point Sensors RH Sensors -120-100 -80-60 -40-20 0 +20 +40 +60 +80 +100 Dew Point o C 10ppb V 10ppm V 1000pp 23000ppm V 20 % V/V >50 % V/V m V

Capacitive RH Sensor Most are based on the principle of adsorption of humidity into a porous polymer film that has a direct electrical response to changes in relative humidity. Ambient temperature MUST be measured and recorded to give readings and validity. Can give good repeatability but need regular calibration for integrity. Fast responding in the relative humidity range

Advanced Ceramic Moisture Sensor Our highly successful ceramic moisture sensor offers a measurement range from -100 to +20 C dew point with superb accuracy and stability Porous Conductive Layer Hygroscopic Active Layer Conductive Layer Ceramic Substrate

Cooled Mirror Dew-point Sensor The cooled mirror sensor principle relies upon the cooling of a metal mirror by a thermoelectric cooler. At dew point, the mirror temperature is measured by a precision platinum resistance thermometer. Light Source Sample In Viewing Port Reflected Light Detector Sample Out Scattered Light Detector Fundamental, high accuracy and long-term stability. Peltier Mirror and 4 Wire PT100

Hydrocarbon Dew Point: The DARK SPOT Technique Light Source Detector Light Source Detector Dry Wetted with Condensate

The DARK SPOT Technique - - - - - - - The dark spot forming

Quartz Disk Diameter: 15,5mm Quartz Disk Thickness: 0,1665mm Quartz Crystal Moisture adsorbs or desorbs on polymer layer Causes a change in mass of the vibrating crystal Increase in mass reduces frequency, a decrease has opposite effect Sorption process fully reversible No long term drift Reliable and repeatable performance

Michell s New Quartz Crystal PMA 2020 Series Eexd Zone 1 0.5 500 ppmv, trend to 1000ppmV On line verification ± 10% reading accuracy -20 to +60 C ambient conditions Selectable 0-1v, 4-20mA (2of), RS485 serial communications

Oxygen Analyzers An wide range of oxygen analyzers for all applications from clean gas to stack. Thermo-paramagnetic sensor. Advaced zirconium oxyde Termo-paramagnetic Sensor MSRS Zirconia Sensor

Product Groups

Sensors and Transmitters Relative Humidity WR293 DT722 WM Series PC Series Price PF211 I7000 Features & Performance

Sensors and Transmitters without RH Pura Cermet II Price Easidew Easidew IS Easidew On-line Easidew Pro Features & Performance

Portable Instruments MDM300 IS MDM300 Price Easidew Portable MDM25 Performance/Features

Calibration Systems DCS HG 10 DG 1/2/3/4 Optical Price PSD HG 1 S 503 Performance/Features/Value

Calibration Systems: general overview Reference Dew-point Hygrometer Traceability to National Standards Air Source Dryer Generator Test Chamber Unit Under Test

Process Analysers Condumax II QMA2030 Liquidew EExd Promet EExd Price Promet I.S. Liquidew I.S. Performance/Features/Value

Product Groups Oxygen analyzers

XTP600 Thermo-paramagnetic Oxygen analyzer A robust, linear and stable oxygen analyzer for measurements in gases such as hydrogen, nitrogen or air. The sensor is housed in an explosion-proof casing, making it suitable for a wide range of applications in hazardous areas.

XZR-400 Zirconia Oxygen analyzer The XZR-400 oxygen analyzer detects trace oxygen in gas and is used to control the purity of gases such as Nitrogen, Argon, Helium and Carbon Dioxide. It is available in wall-mountable, rack-mountable and portable versions, each suited to a range of applications. MSRS Sensor

XZR-500 Zirconia Oxygen analyzer The XZR-500 oxygen sensor from Michell Instruments is designed to determine the excess of air required for optimum combustion. It uses advanced Zirconium Oxide technology to measure levels of oxygen in harsh conditions such as boilers, incinerators and furnaces. Together with the XCU-500 analyser, it provides fast, accurate readings taken in the harshest conditions. MSRS Sensor

Traceability to National Standards

Calibration Traceability Chart for Michell Dew-point Hygrometers Humidity Standard @ NIST NIST Calibrated Hygrometer S4000 No3 NPL Calibrated Hygrometer S4000 No2 Intermediate Transfer Standard Hygrometer S4000 No4 Dew-point Generators Impedance Hygrometer Under Test Humidity Standard @ NPL UKAS Calibration Cooled Mirror Hygrometer Under Test Impedance/Cooled Mirror Hygrometer Under Test NPL Calibrated Hygrometer S4000 No1 Calibration System - Dew-point Generator with S4000

UKAS Calibration Michell Humidity Calibration Laboratory offers: UKAS traceable calibration capability from -90 to +20 C dew point with a measuring capability of +/- 0,15 C dew point @ 20 C dp rising to +/-0,45 C at -90 C dp (at a coverage factor of k=2) Traceable dew point calibration over the dew point range of -100 to +82 C dp with the traceability to national standards over the range -90 to +82 C dew point. NIST traceable calibration available