Natural Gas & Propane Burners

Similar documents
Instructions for High Altitude Installations Above 4500 FT.


LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Page 1 of 6. Machine Serial No. Model Pump Size PRELIMINARY INSPECTION. Service and Connections

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

99 Washington Street Melrose, MA Phone Toll Free Visit us at

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

Columbia Boiler Company

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

Evergreen Liquid Propane Conversion

Revitalize Building Mechanical Systems (4619)

Overview of Gas Range Types

P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Indiana WX Oil Furnace Inspection Guide

DIRECTIVE NO: D-B

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

USER S INFORMATION MANUAL

Good Ideas For Propane Safety

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

User s Information Manual

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

FLEXCORE SERIES MASTERSPEC

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Diocese of Cleveland Facilities Services Corporation

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

USER'S INFORMATION MANUAL

M2 Series Startup Form

TO DO IF YOU SMELL GAS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

systems); a burner by-

PROPOSED October 15, 2013

VSL II QUICK START GUIDE

Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources

Cambridge Engineering, Inc. 24 S-Series Technical Manual

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Low pressure boiler* inspection and maintenance

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

QHT Manual for: SU-2A Gas Burner

Crown Boiler Company

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

Complete burner management in a compact, affordable system

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

d. Portable water heaters used exclusively for underwater diving operations.

THERMAX Efficiency Monitor

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

WHAT TO DO IF YOU SMELL GAS

SECTION WATER-TUBE BOILERS

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

State of the Art. Exceptional Reliability

WARNING FIRE OR EXPLOSION HAZARD.

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

USER'S INFORMATION MANUAL

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Glossary. Carbon Dioxide (CO 2

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

COMBUSTION SAFETY BASICS

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

ML180UH SERIES GAS FURNACE WARNING WARNING

Numerical Standards Listing

Complete Boiler Management in a Compact, Affordable System

Oven Control System Operation - Ver 2.8

Certification Information. Qualifications. Test Specifications. Gas Hydronics Industry References

Numerical Standards Listing

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

VSL II QUICK START GUIDE

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Heating Maintenance and Repair

EL195UH SERIES GAS FURNACE WARNING

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

USER S INFORMATION MANUAL

Guidelines for the Design Engineer

USER'S INFORMATION MANUAL

KN2/4 SERIES MASTER SPECIFICATION

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

BASIC BOILERS NAME :- DATE :-

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Rhode Island PIT FIRES

Transcription:

Natural Gas & Propane Burners WARNING! IF YOUR PARTS WASHER USES A GAS BURNER: If you do not follow installation and operating instructions exactly, a fire or explosion may result, causing loss of life, personal injury, or damage to property. WARNING! Proper setup and adjustment of gascombustion equipment requires combustion-analysis tools (gas manometers, gas combustion analyzer) and knowledge of gas combustion. If you do not have the proper expertise or equipment, seek professional help. Improper adjustment of gas-combustion equipment can cause carbon monoxide discharge, fire, or explosion, resulting in loss of life, personal injury, or property damage. 1. Measure and record the incoming gas pressure to the burner. (NOTE: In the power-up procedure, the burner will not fire until correct water level is reached, and the clock-override switch is turned ON.) 2. Verify that the incoming pressure is within the range specified in the table below. Lower gas pressures can reduce the burner firing rate and increase the time it takes for the machine to heat. Gas differential pressures other than those in the table below will cause firing rates other than those obtained at the factory. Use the gas pressures in as an initial starting point for burner adjustments. 3. If your washer has a burner with one of the firing rates listed in make initial flue damper and burner air-inlet shutter settings as shown. NOTE: Gas pressures below are expressed in WCI.

Refer to the startup procedure in the burner vendor's manual. NOTE: At this point, all manual gas valves should be closed. 4. Verify that the washer reservoir is filled to the factory pre-set level with water. The burner cannot fire until correct water level is reached. 5. Set the temperature controller, according to the following table. After you set the controller, the burner will come on and attempt to fire. (The controller is labeled inside the electrical control panel.) NOTE: The set-point on the controller can differ from the actual temperature. At this point you should follow the startup procedure in the burner vendor's manual. Note: Due to various installation variables, it may be necessary to adjust operating parameters to obtain consistent burner performance. Maximum Actual Operating Temperature Altitude in Feet Temperature F 0-2000 190 F (88 C) 2000-4000 185 F (85 C) 4000-5000 180 F (82 C) 5000 and above call MART Tech Services WARNING! Do NOT exceed recommended settings, or serious damage can occur in the wash pump (cavitation). 6. Take a sample of flue gases where the flue pipe attaches to the roof of the washer cabinet. There is a port at the flue damper for this measurement.

WARNING! A certified burner technician, using flue-gasanalyzing equipment must make any adjustments to the burner. 7. Verify that the fuel/air mixture is correct, by comparing your readings with the following table. Refer also to your vendor-supplied burner manual. WARNING! Proper air/fuel mixture is imperative for efficient operation and safety. Correct Air/Fuel Mixture Unburned combustibles 0% Carbon dioxide (natural gas) 9% -10% Carbon dioxide (propane gas) 10% -12% Oxygen 3% to 5% Combustion efficiency 70% or more Stack temperature 350 F to 1000 F (177 C to 371 C) Carbon monoxide 200 PPM or less 8. Record the water temperature and time of day for reference. Refer to the following figure for gauge location. NOTE: Generally, it takes about two hours for water to heat from 70 F (21 C) up to 190 F (88 C). While the water is heating, you may continue with the power-up procedure.

Thermocouple Temperature Gauge Hi-Limit Controller Adjustment: STINGRAY Parts Washers are equipped with a safety control system to prevent over temperature of the gas heating system. A temperature sensor is located in the flue gas stack and connected to a hi-limit controller in the electrical control enclosure. If the flue temperature exceeds the set point on the hi-limit controller, the heating system will shut down. NOTE: STINGRAY Parts Washers are shipped with the Hi- Limit control set to a predetermined value for your machine size. YOU ARE RESPONSIBLE for accurate adjustment of the Hi-Limit controller. All set-up adjustments are to be done only by people who are qualified and trained for the task.

NOTE: The Hi-Limit control adjustment should be preformed as an integral part of the burner start-up procedure. To set-up the Hi-Limit controller, proceed as follows: 1. Adjust the temperature control unit to 220 degrees F. 2. Allow the burner to operate until the water temperature reaches 200 degrees F. 3. Measure and record the exhaust stack temperature. 4. Adjust the Hi-Limit controller 100 degrees F. over the measured exhaust temperature. 5. Reset the temperature control unit to the proper temperature. The Hi-Limit control is now properly adjusted. NOTE: The set-up and proper adjustment of the HI-LIMIT controller is the responsibility of the end user. Failure to perform the proper set-up will render the hi limit control system inoperative and may violate local codes. Heat - Electric: (if applicable) 2. Check to be sure that the washer is heating. Heat - Steam: (if applicable) 2. Check to be sure that the washer is heating. Heat - Oil: (if applicable) 2. Follow the instructions in your vendor-supplied oil-burner manual. Temperature: 1. Verify that the washer continues to heat up properly. NOTE: Generally, it takes about two hours for water to heat from 70 F (21 C) up to 190 F (88 C). While the water is heating, you may continue with the power-up procedure.