FACT SHEET 6 Transport Refrigeration

Similar documents
FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Guidance for Stationary Refrigeration & Air-Conditioning

Large AC units using a variety of low-gwp options

Refrigerants & Cooling in renovation buildings

Overview of refrigerant alternatives in the air conditioning sector *

Overview of New Refrigerants and Expected Market Trends

New Refrigerants & Selecting Capital Equipment

ON SUBSTANCES THAT DEPLETE

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

The Current Path of Refrigerants

Flammability and the Low GWP Refrigerant Challenge

Reducing Refrigerant Leakage

Possibilities of the RAC sector transformation a technical perspective

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

AIRAH Victoria Refrigerants Update

The cold chain in the fishery sector. Refrigeration Technology Review

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes

Meeting the Challenges of the EU HFC Phase-Down

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Chapter 2. Alternatives to HCFCs and their Characteristics

System Design, Commissioning, Operation

The impact of legislation and trends for the industry

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

The natural solution for domestic refrigeration

Update on Refrigerant Blends

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

Effectively Managing the Transition to Lower GWP Refrigerants

Understanding Applications for Alternative Refrigerants

Transitioning to Alternatives and Challenges in Japan

Updates to Section 608 ODS Management Program

From the Field to the Supermarket

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Natural refrigerant trends in EU, Japan & North America

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Natural Refrigerant Market Trends

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Alternative Refrigerants Part 1 Future and Current Options. Overview

R-404A Alternative with Low Compressor Discharge Temperature

Refrigerant and Energy Regulations Update

Making equipment decisions

Standards to facilitate the HCFC phase-out

Exhibition Hall 1. Fachprogramm. Technical Programme

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Transitioning to Alternatives and Challenges in Japan

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

Refrigerant & Energy Regulations Update

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

Natural Refrigerants.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Legislation & Standards

A refrigeration system for supermarkets using natural refrigerant CO 2

Honeywell Refrigerant Update

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Chillers for High Ambient Conditions: What Technologies and Fluids?

International New Technology and Refrigerant Symposium

Evaluation of HCFC Alternative Refrigerants

EC Regulation No 842/2006 on certain fluorinated greenhouse gases

Flammability and New Refrigerant Options

Actions to Control Emission of HFCs in Japan

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Understanding Applications for Alternative Refrigerants

Brazed Plate Heat Exchanger for CO Applications

natural refrigerants - global trends & developments

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

Low GWP Refrigerants for Air Conditioning Applications

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

REFRIGERANT PROCEDURE

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

Trends and Perspectives in Supermarket Refrigeration

Energy Efficiency Considerations in Refrigeration Systems

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Refrigerant Rule Update

CHAPTER 1 INTRODUCTION

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

Update on Opteon Refrigerants

DuPont ISCEON 9 Series Refrigerants

CO 2 transcritical FTE System Full Transcritical Efficiency

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Retrofitting Existing Systems

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

EXHIBIT G REFRIGERANT MANAGEMENT POLICY

Transcription:

UNEP Ozone Secretariat Fact Sheets on HFCs and Low GWP Alternatives UNEP Ozone Secretariat Background Material on HFC Management October 205 FACT SHEET 6 Transport Refrigeration. Description of market sector This market sector includes refrigeration systems used in various modes of transport. Most transport refrigeration systems are used for the carriage of frozen or chilled food and beverage products. Market sub-sectors Transport refrigeration can be split into the following three sub-sectors: a) Road vehicles (vans, trucks, trailers) b) Intermodal containers (reefer containers) c) Ships (included refrigerated cargo vessels, fishing vessels and passenger liners) Operating temperatures Food and beverage products are transported at two temperature levels : Medium temperature (MT) for chilled products held at between 0 o C and +8 o C Low temperature (LT) for frozen products held at between -8 o C and -25 o C An important feature of most transport refrigeration systems is the ability to operate at either of these temperature levels. Stationary systems are usually dedicated to just one temperature level, whereas transport systems regularly switch between MT and LT. It is also a common requirement for road transport to provide simultaneous cooling at both temperature levels to separate compartments. Transport systems encounter large variation of ambient temperature conditions, depending on routes undertaken. Intermodal containers could have to operate in ambient varying from -0 C to +50 C. Typical system design The majority of transport refrigeration systems use direct expansion (DX) vapour compression refrigeration cycles. There is a wide range of designs: Small vehicles (e.g. vans for shopping deliveries) have a compressor powered by the vehicle engine, via a belt drive; cooling can only be provided when the vehicle engine is running. Larger road vehicles have a dedicated diesel engine powering the refrigeration system, typically via a mechanical connection, allowing operation when the vehicle main engine is off. Some road vehicles use electrically driven compressors with electricity generated either by the main vehicle engine or a dedicated diesel engine. Intermodal containers have electrically driven compressors. When a container is on board a ship it is connected to the ship s electricity supply. When a container is on a road trailer it is connected to the main diesel engine generator or uses a dedicated diesel generator. Ship refrigeration systems are much larger than those for road vehicles or containers and can use a wide variety of different designs. Some of the discussion in Fact Sheet 5 on Industrial Refrigeration is applicable to ship based systems. Non-food products may be transported at much lower temperatures (e.g. liquefied natural gas). Some food products are transported at higher temperatures e.g. bananas at up to +5 o C Fact Sheet 6: Transport Refrigeration Version 2, October 205

Alternative technologies There is limited use of cooling using eutectic plates. The plates contain a phase change material that is usually frozen in a stationary refrigeration facility. Cooling is provided to the contents of a vehicle as the material melts during a journey (a similar principle to an ice pack used for domestic cold boxes). It is also possible to provide cooling via an on board supply of liquid nitrogen or CO2, although this is usually an expensive option in terms of energy costs. Changes driven by ODS phase out: Prior to 990 the majority of road transport systems and containers used R-502 or CFC-2. From around 997, R-404A 2 or HFC-4a have been used in non- Article 5 countries and more recently in Article 5 countries. HCFC-22 is still widely used in ships, especially those owned by Article 5 countries. Table : Transport refrigeration: summary of characteristics for HFC systems Market sub-sector: Road vehicles Containers Ships Typical refrigerant charge to 8 kg 4 to 8 kg 20 to 000 kg Typical cooling duty to 0 kw 5 to 5 kw 40 to 2000 kw HFC refrigerants widely used R-404A (GWP 922) HFC-4a (GWP 40) Refrigeration circuit design Diesel or electrically driven compressor, DX Electrically driven compressor, DX Various Manufacture / installation Small: site installed Larger: factory built Factory built Site installed Typical location of equipment Varied operation locations affect safety issues Typical annual leakage rate 8% to 20% % to 2% 5% to 0% Main source of HFC emissions Operating leakage Operating leakage Operating leakage Approx. split of annual refrigerant demand New systems 40% 50% 20% Maintenance 60% 50% 80% Small refrigerated truck, compressor located by main vehicle engine 2 R-507A can also used for transport systems although much less widely than R-404A. Comments made about R-404A in this Fact Sheet also apply to R-507A. All GWP values are based on the IPCC 4 th Assessment Report Fact Sheet 6: Transport Refrigeration 2 Version 2, October 205

Refrigerated trailer with dedicated diesel engine and cooling system Intermodal container with dedicated cooling system Flake ice making system for a fishing trawler Small road vehicles usually have a refrigeration compressor located in the main engine compartment refrigerant pipework is installed by the vehicle body builder to connect the compressor to the evaporator mounted inside the cooled space and the condenser mounted at roof level. Larger road vehicles usually have a factory built pre-charged refrigeration unit mounted at the front of a refrigerated trailer. These units have a small diesel engine and a factory built refrigeration circuit installation work does not involve any refrigerant pipework. Intermodal containers also have dedicated refrigeration units that are factory built and pre-charged. Ships require a range of different cooling systems, depending on function e.g. there are specialised vessels for bulk products (e.g. liquefied natural gas) and for preserving fish in fishing vessels. Passenger liners require large cooling systems both for food preservation and for air-conditioning. Fact Sheet 6: Transport Refrigeration Version 2, October 205

2. Alternatives to current HFC refrigerants Table 2: Lower GWP alternatives for road transport and containers Refrigerant 4 GWP Flammability 5 Comments R-744 (CO2) R-452A 24 Transcritical R-744 is being developed for large road vehicles and for intermodal containers. Use of R-744 requires major changes to the design of transport refrigeration systems and the development of many new components. Some systems were trialled in 204 and it can be expected that R-744 may be widely available for transport applications by 2020. A new blend targeted at the transport sector; an R-404A alternative with low discharge temperature at high ambient. R-407A R-407F 207 825 There has been some limited use of these blends in road vehicles as R-404A alternatives. High compressor discharge temperature must be addressed in high ambient e.g. using liquid injection. R-407H* R-442A R-448A R-449A R-449B 495 888 87 97 42 Newly developed blends with properties similar to R-404A, but lower GWP. Currently there is very little commercial experience or availability in transport sector, but they may be suitable as R-404A alternatives in new systems. High compressor discharge temperature must be addressed in high ambient e.g. using liquid injection. R-450A R-5A R-5B* 60 6 596 Newly developed blends with properties similar to HFC-4a. May be suitable for new road vehicles and containers that are currently designed to use HFC-4a. HFC-2 675 2L Recent developments are showing high efficiencies and acceptable risks for operation with certain flammable HC-290 HC-270 2 refrigerants including HCs and HFC-2. Use of flammable refrigerants require special safety measures and new designs. Blends awaiting ASHRAE number 50 to 600 2L Blends under development with properties similar to R-404A and R-40A. Use of flammable refrigerants require special safety measures and new designs Table 2 shows alternatives that are applicable to road transport and containers. There are trials with HFC-2 and hydrocarbons; flammable refrigerants require correct safety measures, engineering design efforts, quality controls, proper maintenance, education and training. Other lower flammability refrigerants with GWPs in the 50 to 600 range are also being considered. Ships can use a wider variety of alternatives, which are not shown in Table 2. Many of the options discussed in Fact Sheet 5 (industrial refrigeration) are applicable. R-77 and R-744 are both used e.g. in fishing vessels. The HFOs suited to large industrial chillers (e.g. HFO-24ze) may be applicable in passenger ships. 4 Refrigerants and text shown in italics have been added in this latest version of the Fact Sheet * R-numbers marked with an asterisk are awaiting final approval from ASHRAE 5 Flammability categories based on ISO 87 and ISO 549 = higher flammability; 2 = flammable; 2L = lower flammability; = no flame propagation Fact Sheet 6: Transport Refrigeration 4 Version 2, October 205

. Discussion of key issues Safety and practicality Road transport and containers: Flammability is a very important consideration. Most vehicles travel through various countries and need to comply with international UN or IMO-CSC codes for transport of dangerous goods requirements with regard to refrigerants. These give no restrictions for use of less than 2 kg of flammable refrigerants. However, it may be also necessary to comply with a range of national safety legislation which may be more restrictive. Use of a non-flammable refrigerant simplifies this issue. As shown in Table 2, many of the options being considered are non-flammable. If R-744 can be used this provides the lowest possible GWP. R-744 was listed by U.S. EPA in 204, as acceptable for refrigerated transport applications. Nonflammable fluorocarbon alternatives to R-404A have a GWP in the range 400 to 200. The availability of spare parts and maintenance skills is an important consideration as road vehicles could require servicing in a remote location. This could have a strong influence on the selection of alternatives and enhances the argument for a globally consistent approach. Transport systems may require certification to ensure effective preservation of foodstuffs. The ATP is a UN treaty that affects temperature controlled vehicles. It applies in more than 50 countries and sets performance standards for vehicle bodywork and refrigeration units. Compliance with ATP is essential for new refrigerants being introduced. Ships: Use of R-77 (ammonia) is a possibility on non-passenger ships, as the crew can be trained to address safety issues. It is already used in a range of vessels, including fishing trawlers. R-77 may not be appropriate for passenger ships. Commercial availability Road transport: It is likely that R-404A alternatives will become widely used in new equipment in some regions within the next 5 years. The rate of development for R-744 depends on the results of current trials. Intermodal Containers: R-744 systems have been tested and are available on the market. Various lower GWP fluorocarbon alternatives to R-404A are also becoming available. One intermodal container manufacturer has announced the possible introduction of a refrigeration system with HCs in 208-9 subject to the constraints of future legislation. Ships: Availability of alternatives for ships may follow developments for industrial refrigeration applications. R-77 systems are already widely available. R-744 requires significant development of systems and components. HFO chillers may become widely available within 5 years. Cost Road transport and containers: Fluorocarbon alternatives such as R-452A will have a similar cost to R-404A systems. The refrigerant may be more expensive, but this should not increase the total system price by more than a few percent. Costs for R-744 in transport systems are not yet known. Costs are not yet known for intermodal containers using HFC-2 or HCs. Ships: R-77 could be 0% to 0% more expensive to install than HCFC-22, but life cycle costs could be lower through improved efficiency. HFO-24ze chillers will only be slightly more expensive than HFC-4a systems, because of a higher refrigerant price. Fact Sheet 6: Transport Refrigeration 5 Version 2, October 205

Energy efficiency Road transport and containers: The energy efficiency of fluorocarbon alternatives is expected to be higher than exisiting R-404A systems. The efficiency of R-744 systems will depend on ambient temperature. In a mild climate (e.g. less than around 20 o C) the efficiency has the potential to be higher than R-404A systems. In hotter conditions the efficiency will fall. For many highly populated regions the average ambient for typical road transport operation is low enough for R-744 to have an efficiency advantage. HCs and HFC-2 are expected to have similar efficiencies to HFC-4a. Ships: R-77 and cascade R-744 systems have the potential for higher efficiency than R-404A. Efficiency of HFO-24ze chillers expected to be equal to HFC-4a systems. Applicability in high ambient Road transport and containers: In high ambient some fluorocarbons may not be ideal because of the impact of high discharge temperatures. R-452A is an option for high ambient conditions. R-744 is likely to have lower efficiency in high ambient. Ships: There are no extra challenges for new equipment being designed for high ambient. Most ships already require systems that can operate at high ambient and the use of water cooled condensers reduces the condensing temperatures to acceptable levels. Opportunities to retrofit existing equipment Road transport and containers: Retrofit of R-404A transport systems is not likely to be widespread. It is technically possible to convert to lower GWP refrigerants but the ATP Regulations could add significantly to conversion cost as vehicles may need recertification. In most cases the move to a lower GWP refrigerant will occur when old equipment is being replaced. Ships: There is potential to retrofit R-404A systems on ships with a lower GWP fluorocarbon, although there is currently little experience of this being done. Technician training R-744: Systems using R-744 operate at a higher pressure than HFC systems and may be based on unfamiliar system design. Technicians need extra training to work on R-744 systems. If R-744 technology is adopted the transport sector will need to ensure the availability of trained technicians across the regions supplied by R-744 equipment. R-77: There is already use of R-77 in parts of the shipping industry (e.g. fishing vessels) and there is some availability of trained technicians. If use of R-77 increases then extra training based on established courses will be required. Other flammable refrigerants: If flammable refrigerants (e.g. HCs or HFC-2) are to be used for road transport or containers, new training initiatives will be required. Minimising HFC emissions from existing equipment Most emissions occur through leakage during the operating life of transport equipment. Applying best practice in design and maintenance practices can lead to significant leakage reduction. During system maintenance it is important to ensure refrigerant is not vented to atmosphere. At end-of-life over 95% of refrigerant from old systems can be recovered if adequate procedures are used. Fact Sheet 6: Transport Refrigeration 6 Version 2, October 205