ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

Similar documents
UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

AirPurification System

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

AIR PURIFICATION SYSTEM

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

Ultraviolet Disinfection Unit Installation and Owners Manual

Refresh. Whole House Germicidal UV Air Treatment. Treats airborne germs, allergens and mold for a healthier, fresher indoor environment

Owner s Manual LIMITED WARRANTY INFORMATION OBTAINING WARRANTY SERVICE FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS REGISTRATION

Model CWA200 Owner s Manual

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

Owners Manual Model: XXL

PCO/UV N-Duct Model. Owner s Guide

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

Owner s Manual. Airgle Personal Air Purifier ( Model: AG25 )

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

2 Installation Notes

IMPORTANT SAFETY INFORMATION:

HEALTHY HOME AIR PURIFICATION SYSTEM

UV100E Ultraviolet Air Treatment System

HEALTHY CLIMATE PureAir Air Purification System

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

BioZone Scientific International contact information

RS4 Whole House IAQ System

Healthy, clean air for your home

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

Design Manual Installation Operation Maintenance

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Document No B1 February Atlantic Ultraviolet Corporation

CA3500, BA3500, CH3500 New Comfort

Installation, Start -Up, and Operating Instructions

Ultraviolet Air Disinfection Equipment

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

WHYNTER Eco Pure Air Purifier

IMPORTANT SAFETY INFORMATION:

BIOZONE ICEZONE OWNER'S MANUAL Single Horizontal Evaporator Style Ice Machines BioZone Scientific International

SERVICE REQUIREMENTS

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

1020 Industrial Drive, Orlinda, TN fax

Owner s Manual.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Document No A3 Revised February Atlantic Ultraviolet Corporation

INDOOR AIR QUALITY PRODUCT LINE CARD 10.18

Integrated Ventilation System

PureAir Air Purification System PCO-12C/20C

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

by Owner s Manual For use with model: AA250 For safety and to ensure proper use carefully read the contents of this manual before operating the unit.

Dayton Electric Infrared Fireplace User Manual

healthy comfort Indoor Air Quality Solutions

BIOZONE ICEZONE OWNER'S MANUAL Closely Spaced Evaporator Style Ice Machines BioZone Scientific International

Introduction (Thanks / Warnings / Records) Features / Benefits Controls / Diagrams Initial Setup (Placement / Settings) Operations Maintenance

GENANO AIR PURIFICATION TECHNOLOGY

Pressurized Filter Up to 1250 gallons

IMPORTANT SAFETY INFORMATION:

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Model TL104 MANTL104. Test Lamp for Flame Detection

ELECTRIC FIREPLACE OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

Instruction Manual E4 ChamberIR Heater

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

healthy comfort Indoor Air Quality Solutions

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

e Bath Fan with Light User s Guide

USE & CARE INSTRUCTIONS

600 Series Spin-on Fuel Filter/Water Separators

Quest Power Electric Heat EHS 31 Pro

UV-C Sanitizing System USER MANUAL Purifying Wand (EPLPW)

IMPORTANT SAFETY INFORMATION:

M Series Fan Filter Units

Chargebuster Ion Gun Installation, Operation and Maintenance

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Wiring Instructions. High-Capacity Steam Humidifiers

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

Surgically Clean Air Inc.

ELECTRONIC AIR PURIFIER

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE

Service Manual Model 3163

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Owner s Manual TDS8515. Model Numbers:

Installation Operation Maintenance

The PureAir system improves air quality throughout your home.

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Chargebuster Ion Gun Installation, Operation and Maintenance

Installation and Operating Instructions. Rev. 3/24/17. Continuous Antimicrobial Air Cleaner

Transcription:

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE Models: UMX-1200T/ UMX-1900T / UMX-1202T/ UMX-1902T 120-240VAC Power Input with Remote Mount Lamps Page 2 Shipping and Packing list, Safety Precautions Table of Contents: Page 3-4 General Application Guidelines and Recommended Installation Page 5 Installation Steps for External Remote Lamp Mounting with External Mounting of Power Supply, and Internal Remote Lamp Mounting with External Mounting of Power Supply Page 6 Installation Steps for Re-Fresh PCO Module Page 7 Maintenance, Troubleshooting, Lamp Replacement and Reset Procedure Page 8 UV Lamp Monitor, Power Consumption and Replacement Part Number, Warranty LEAVE FOR HOMEOWNER DC-IH-0216

Shipping and Packaging List: UMX Electrical Housing Ultra-Ion Re-fresh PCO module w/ gasket 6- ¾ inch 5/16 self tapping sheet metal screws 6 Electrical Housing power cord Warning Label Residential Warranty Card UMX- 1200T, 1202T, 1900T, 1902T **1200T and 1900T Series- 1 12 or 17 T3 Lamp **1202T and 1902T Series- 2 12 or 17 T3 Lamp *8 or 12 PCO module and T3 Lamp mounting plate mounting screws *2 or 4 T3 Lamp mounting screws *1 or 2 T3 Lamp mounting plate * Number depends on 1 or 2 T3 Lamps ** T3 Lamp gasket included Safety Precautions: It is recommended that this unit be installed and maintained by a trained technician: WARNING: UV Hazard. Always protect eyes from ultraviolet light. NEVER look at UV lamps in operation. Unplug or disconnect power before relamping or servicing. WARNING: Severe eye damage or temporary blinding may occur. WARNING: DO NOT operate outside of Air Handler. Mount lamp base to duct first. WARNING: No openings in duct are allowed which would give direct line-of-sight to the UV light. In the event of accidental breakage or replacement of the ultraviolet lamp, please ensure that the lamp is disposed of in accordance with local and state environmental laws regarding fluorescent lamps containing mercury. Notice: All wiring inside of the duct or air handling system in direct line of site of the UV lamp must be shielded with aluminum foil tape or equivalent non-combustible material. When installing this unit, select a mounting location that prevents ultraviolet light exposure to plastic flexible duct liner or other plastic components with unknown resistance to ultraviolet light. Ultraviolet light may cause color shift or structural degradation of plastic HVAC components 2

General application guidelines for Ultramax Ultraviolet air purification systems Ultravation manufactures several configurations of Ultraviolet disinfection products to meet any installation criteria. Ultravation two lamp ultraviolet systems are designed to adequately treat up to a 5 ton system or 3,500 sq ft. Whenever possible use a two lamp configuration with the longest lamp length possible for the installation. Up Flow **Up Flow Ultravation suggests mounting on the exit side of the HVAC system before the ductwork branches off. This will ensure that the airborne contaminants reaching the ultraviolet purification system and the Re-Fresh Odor reduction module have been reduced to an acceptable Micron size by the HVAC systems filter. Ultravation Ultramax products have been designed for peak performance in the cooler temperatures commonly found in the supply plenum of a typical HVAC system. Installing an Ultraviolet system in the return may degrade the media filter and/ or collect dirt particles on the UV lamp glass gradually decreasing performance. If this is the obvious source of microbial growth then placing the Ultraviolet system in the return is the best solution. **Caution must be taken to ensure Ultraviolet light is not coming in contact with the media filter or being exposed outside the enclosed system. Ultravation s exclusive Re-Fresh odor reduction module performs continuous photo catalytic processing, constantly reducing or eliminating unwanted odor and bacteria resulting in clean fresh breathable air. Ultravation Ultraviolet systems produce no ozone. There is no harmful by-products or off gasing taking place in the sterilization process or the photo catalytic process. Up Flow **Up Flow Horizontal The surrounding illustrations show the flexibility offered with the Ultravation Ultramax product line actual installation may vary depending upon installation criteria, if you need help or have questions call our toll free help line: 1-866-GO-UV-AIR 468-8247 ext 16 9:00 am 5:00 pm Est. Horizontal 3

Recommended Installation Exclusive Re-Fresh PCO odor reduction Module - reduces odor, VOC s and bacteria. Simply add more for greater odor reduction. Produces no ozone or other hazardous gases! Patented T3 lamp technology provides 40% more UV than the competition Heavy Duty extruded aluminum commercial grade power housing. Available in single and dual lamp configurations in a variety of incoming voltages including 24VAC and 120v (UMX) Full 10 year warranty Mounting Plate with gasket material provides a safe air tight fit Patented lamp safety connection, prevents accidental exposure to harmful UV rays. 6 Ft. remote lamp leads (select models) allow for the flexibility required for most installs. 4

Installation steps for remote lamp mounting, remote lamp replacement, and external mounting of power supply: 1. Determine a suitable location to install unit housing. Mounting location should be of sufficient strength as to support the unit; otherwise reinforcement of the ductwork may be necessary. Lift into place against ductwork. Fasten unit in place with four self- tapping screws (supplied). 2. Select location for UV lamp module, drill a 1 hole for each lamp. Mount mounting plate over drilled hole with screws provided. Insert UV lamp module into hole. Attach to HVAC system with 2 self-drilling screws (provided). 3. Plug the rubber lamp connector fully onto the installed UV lamp assembly. Be sure the 4 pinholes are orientated properly to the 4 mating pins of the lamp. 4. Plug in unit. Note: for 240 volt applications, splice off the 120 volt plug and replace with a 240 volt plug. Plug into a 240 volt receptacle. Installation steps for remote lamp mounting and internal mounting of power supply: 1. Determine a suitable location to install unit housing. Mounting location should be of sufficient strength as to support the unit; otherwise reinforcement of the ductwork may be necessary. Lift into place against ductwork. Fasten unit in place with four self- tapping screws (supplied). 2. To utilize the internal mounting bracket - first install the bracket inside the air handler in a location that will position the UV lamp such that it bathes the entire surface to be treated. Next plug the lamp connector onto the lamp. 3. Plug in unit. Note: for 240 volt applications, splice off the 120 volt plug and replace with a 240 volt plug. Plug into a 240 volt receptacle. Push the lamp connector and lamp into the bracket as shown. This will hold the lamp in place. Note: The T3 UV lamp assembly can be removed independently, simply by removing the 2 screws in the lamp base. Note: the pins are in a rectangular patent and can only be mated in 2 positions. See the illustration of the T3 lamp 4-pin connector. 5

Installation steps for Exclusive Re-Fresh PCO odor reduction Module: 1. Find a location adjacent to the UV lamps to mount the PCO module. To activate the PCO module it requires UV light shinning on its surface. PCO module can be mounted within inches of the UV light, or if necessary the module can be within 2 ft. of direct UV light and still be activated. 2. To mount the PCO module you will need to drill one 2 1/2 diameter hole. The base plate of the module will need to be screwed to the duct or air handler with the 4 screws supplied. 3. The PCO module measures 14 ¾ inches long by 2 ½ diameter The surface area of the module relates directly to the amount of VOC s it can eliminate. If necessary the Module can be trimmed to a shorter length to accommodate installation in the air handler. It is beneficial to install additional PCO modules in the area of the UV lights, thereby increasing the airborne bacteria disinfection rate and the removal of VOC s. Also the PCO modules may be installed completely internally. 6

Maintenance: Typical maintenance consists of replacement of the ultraviolet lamps. UV lamps undergo a photochemical process during operation. This slowly reduces the amount of UV light generated to disinfect against airborne pathogens. For optimum air stream disinfection against airborne pathogens it is recommended the UV lamps be changed on an annual basis. When installing new lamps, ensure that the lamp glass is free from any fingerprints or debris, as this may alter the path of the UV energy. Use rubbing alcohol and a dry cloth to remove any surface contaminants. The PCO/VOC Module when used with a MERV 11 (minimum) rated filtration, no maintenance will be required for 10 years. Troubleshooting: Important information: It is a normal characteristic of all UV lamps to blacken around the filaments of the lamp. This does not signify the lamp is defective or not emitting Ultraviolet light. The only time a UV lamp is defective is if it will not light. UV Lamps that illuminate will not qualify for Warranty. Verify the unit has power (120-240 volt) When resetting the unit, depress reset button. (if the unit does not reset, wait 5 minutes to depress again) Power switch is in the ON position Lamps are securely plugged into their sockets The electronic circuit of a 2-lamp system only operates when both lamps are operating. Verify fuses are not blown. Remove both replaceable 5.0 amp MDL fuse from fuse holder and visually inspect or perform a continuity test of the fuse. Verify what signal if any the UV Lamp Monitor LED is emitting. (See below). Verify if in fact the UV lamps are on or off. Do not look at the UV light without proper eye protection. NOTE: UMX series- If just a single UVC lamp of a 2 lamp UVC system is light, than the lamp that is not light is out of orientation. Lamp Replacement and Reset Procedure: *See Lamp Installation for Replacement Procedure. NOTE: When replacing lamps after 1 year or 2 years of operation disconnect power to the unit first. After the lamps are in place, complete steps 1-5 to set the service indicator to 0. For optimum 24/7 air stream disinfection it is recommend the UV-C lamp is replaced on an annual basis. Service Indicator Light: To set the service indicator Light: It is recommended that a certified technician perform this operation. 1. To set or reset the annual service indicator the unit must have power to it. 2. Remove the cover from the unit, by removing the screw on the face of the unit. 3. Press down and hold the square yellow RESET button (hold down for 10 sec.) on circuit board (located adjacent to the LED on the circuit board), the LED should turn GREEN while the button is depressed. 4. Release the square yellow RESET button. 5. Replace the cover, and inspect operation. LED should be Green. Please contact your local dealer or Ultravation directly for replacement lamps and batteries There are NO user serviceable parts inside. Refer servicing to qualified service personnel. Note: A flashing red every 1 seconds and a beep every 1 seconds does not necessarily mean the lamps are defective or no longer emitting UV, it is sensing the lamp(s) in the unit are not on. This could be caused by other factors. In this case a service technician should be contacted. Please contact your local dealer or HVAC contractor for replacement lamps. There are NO user serviceable replacement parts other than the lamp and fuses. Refer servicing to qualified service personnel. 7

UV Lamp Monitor: LED Color Green Audible Visual Alarm No audible Unit Status OK Solid Red No Audible Reset lamp service indicator or replace lamp within 30 days Plusing Red (Every 5 seconds) Flashing Red (Every 1 second) Power Consumption: Beep every 60 Minutes Beep every 1 second Lamp has exceeded 1 year of operation reset or replace lamps UV lamp(s) are not lit Model Number of Lamps Power Consumption UMX -1200T 1-12 inch straight 19 Watts (.16 A @ 120VAC) UMX -1900T 1-17 inch straight 29 Watts (.25 A @ 120VAC) UMX -1202T 2-12 inch straight 38 Watts (.32 A @ 120VAC) UMX -1902T 2-17 inch straight 58 Watts (.49 A @ 120VAC) Replacement Parts: Description Replacement Part Number Model UMX 12 T3 Lamp ASIH1001 UMX 17 T3 Lamp ASIH1003 UMX 5 Amp Fuse EL-PP-0044 UMX Ultra-ion Re-fresh PCO Module 94-004 Warranty: Ultravation warrants this product against any defects in material or workmanship for a period of 10 years after date of consumer purchase, with the exception of the Ultraviolet Lamp, which is warranted for a period of one year after date of consumer purchase. This warranty does not include damage to the unit from accident, misuse or improper installation. If this product should become defective during the warranty period, Ultravation will elect to repair or replace the product free of charge. Ultravation will return repaired or replaced warranted products pre-paid, provided that the product was delivered pre-paid. Ultravation shall have no responsibilities for charges incurred by the customer for installation or removal of warranted items. Liability is limited only to the replacement or repair of this product This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. All returns must be accompanied by a return authorization number, which may be obtained by contacting Ultravation, Inc. Ultravation, Inc. ~ P.O. Box 234 ~ 218 Jones Drive ~ Brandon, Vermont 05733 Phone: 802-247-0034 ~ Fax: 802-247-0033 ~ 8